You are on page 1of 2
CHALLENGE SUB DIVISION PROJECT ‘TRANSFORMER 2 - (SOOKVA) TOTAL MAXIMUM DEMAND No. P.. LOT DESIGNATION VOLTAGE LoaD{ prot. tyee PROTECTION RATING w er 2 RESIDENTAL—«28O—7.8 SERV FISE «A 2 9 22 RESIDENTIAL «= 280788 SERV. FUSE 3A, 3 19 RESIDENTIAL «280788 seRv.FUSE 3A ata 20 RESIDENTIAL 788 Semv FUSE 3A s 9 37 RESIDENTIAL «240.788 SERV.FUSE 3A 6 3 18 RESIDENTIAL «= 2407.8 SERV FUSE 3A 7 8 15 RESIDENTIAL «24078 SERV. FUSE 3A 8 2 16 RESIDENT. «(240788 SERV.FUSE 3A 9 7 13 RESIDENT. «= 2407.8 SERV.FUSE 3A 0» 7 14 RESIDENTIAL = 200788 SER. FUSE GA m2 2 RESJDENTIAL «2407.68 SERV.FUSE 3A ua 4 RESIDENT, = 240768 SERV.FUSE 3A feces $ RESIDENT. = 2407.68 SERV.FUSE GBA ua 6 RESIDENTIAL «2407.88 SERV.FUSE GRA 3% 4 7 RESIDENTIAL = 2407.68 SERV.FUSE 3A ed 8 RESIDENTIAL «2407.8 SERV.FUSE GBA ys 9 RESIDENTIAL = 2407.8 SERV.FUSE 3A ws 10 RESIDENTIAL «40.788 SERV.FUSE © G3A isseeetac) 1 RESIDENTIAL = 24078 SEWV.FUSE GBA » 6 32 RESIDENTAL «2407.68 SEWV.FUSE GBA n 6 6 RESIDENTIAL «240788 SERV. FUSE 3A mae 6 RESIDENTIAL «24078 SERV.FUSE G3 2 0 66 RESIDENTIAL «40.788 SERV FUSE 3A uo 67 RESIDENTIAL «2407.68 SERV.FUSE 3A 3B oe RESIDENTIAL «= 240788 SERV.FUSE BA aoe 69 RESIDENTIAL «= 2407.8 SERV.FUSE 2A ae) 70 RESIDENTIAL «= 240768 seRv.FUSE A 28 7 RESIDENTIAL = 24078 SERV.FUSE 3A 2» 20 RESIDENTIAL 240 768 SERV.FUSE GBA 0 == 73 RESIDENTIAL «20078 SERV.FUSE GBA uo 83° RESIDENTIAL «= 2407.68 SERV.FUSE GBA n 8 62 “RESIDENTIAL «2407868 SERV.FUSE GBA som si REDENT. «240,788 SERV.FUSE —G3A uo $0 RESIDENTIAL «240.78 SERV.FUSE —G3A 3B 79 RESIDENTIAL «= 2407.68 SERV.FUSE 2A 6 OB 78 RESIDENTIAL «2407.68 SERV.FUSE —63A es 7 RESIDENT. «240788 SERV. FUSE 3A 3B OR 76 -RESDENTIL «2407.8 SERV.FUSE —G3A 2 of 75 RESIDENTIAL «240788 SERV.FUSE GBA 0 74 RESIDENTIAL «= 2407.68 SERV.FUSE «GBA a 8 4 RESDENTIAL «240768 SERV.FUSE BA a 8 #5 RESDENTAL «240768 SERV.FUSE GBA a HEE 1 RESIDENTIAL «2407.68, SERV.FUSE GBA ace 2 RESIDENTIAL «= 2407.68, SERV.FUSE «3A 4S PARK a6 SERVICES. «24024 SERV.FUSE 3A 45 WOMMSTIDRS 87 = services a5 18a HRC FUSE 5A 47 _ STREET GATS SERVICES 447378 Rc Fuse 164 FULL LOAD CURRENT FOR TX 2 CIRCUITS (A) 480 «6496 * PROPOSEE FORMER CURRENT RATING - SOOK / (415*1.732) * .97 = 667A + suWioni D FOR TA2RETICULATION = 496A FULL LOAD RATING OF PROPOSED SOOKVA TX = 657A PERCENTAGE TRANSFORMER LOADING = 496A / 667A* 100 = 74.4% CHALLENGE SUB DIVISION PROJECT ‘TRANSFORMER 1 - (500KVA) TOTAL MAXIMUM DEMAND SINGLE FULL po NO. PB, == LOT# DESIGNATION. VOLTAGE goAD( LOAD PROT. TYPE RATING kw) a) 7 9 RESIDENTIAL 32 SERV. FUSE 2 29 39 RESIDENTIAL © 240, 7.6832 SERV. FUSE 63a 3 28 42° RESIDENTIAL © 24076832 SERV. FUSE 3A 4 28 41 RESIDENTIAL «24076832 SERV. FUSE 3A 5 2 43° RESIDENTIAL © 2407.68 32 SERV. FUSE 3A 6 38 54 RESIDENTIAL. ©2407-6832 SERV. FUSE 683A 7 38 55 RESIDENTIAL 240. 7.6832. SERV. FUSE 63a 8 39 52 RESIDENTIAL © 2407.68 «32 SERV. FUSE 63a 9 39 53 RESIDENTIAL © 240, 7.6832 SERV. FUSE 3A 10 40 50 RESIDENTIAL. © 240. 7.6832 SERV, FUSE 63a 11 40 SL RESIDENTIAL. © 240 7.6832 SERV. FUSE 63a 2 a 48 RESIDENTIAL © 2407.68 32 SERV. FUSE 63a 1B 4a 49 RESIDENTIAL © 24076832 SERV. FUSE 63a 14 42 46 RESIDENTIAL © 24076832 SERV. FUSE 63a 15 a2 47 RESIDENTIAL © 2407.68 «32 SERV. FUSE 683A 16 43 44° RESIDENTIAL 24076832 SERV. FUSE 63a v7 43 45 RESIDENTIAL 2407.68 «32 SERV. FUSE 3A 18 30 37 RESIDENTIAL © 240 7.6832. SERV. FUSE 63a 19 30 38 RESIDENTIAL. © 240 7.6832. SERV. FUSE 63A 20 31 35 RESIDENTIAL © 240 7.6832, SERV. FUSE 63A 2 31 36 RESIDENTIAL. © 240 7.6832 SERV. FUSE 63A 2 32 33° RESIDENTIAL. © 240 7.6832 SERV. FUSE 63a 23 32 34 RESIDENTIAL. © 240 7.6832 SERV. FUSE 63a, 24 33 31 RESIDENTIAL © 240 7.6832 SERV. FUSE 63a 25 33 32. RESIDENTIAL © 240 7.6832 SERV. FUSE 3A, 26 34 29 RESIDENTIAL © 240, 7.6832 0 SERV. FUSE 63a 27 34 30 RESIDENTIAL © 2407.68.32 0 SERV. FUSE 63a 28 35 27 RESIDENTIAL © 240 7.6832 0 SERV. FUSE 63a 29 35 RESIDENTIAL 2407.68 «32 0 SERV. FUSE 63a 29 36 ESIDENTIAL 2407.68 «32 0 0 SERV. FUSE 63A 29 36 RESIDENTIAL 2407.68 «32 0 0 SERV. FUSE 63A 29 37 RESIDENTIAL 240« 7.6832. 0 0 SERV. FUSE 63A 29 37 RESIDENTIAL 240« 7.68 «32. 0 —0_ SERV. FUSE 63a, 29 4 RESIDENTIAL 2407.68 «32s 0 SERV. FUSE 3A 29 4 61 RESIDENTIAL «2407.68 32. SERV. FUSE 63a 28 15 62 RESIDENTIAL © 2407.68 32. SERV. FUSE 63A 29 1s 63 RESIDENTIAL. «= 24076832. SERV. FUSE 634 29 13 25 RESIDENTIAL «© 2407.68 32. 0 SERV. FUSE 63a 23 B 26 RESIDENTIAL «2407.68 «32s SERV. FUSE 63A 29 2 23° ©—ORESIDENTIAL «240, 7.6832 SERV. FUSE 63A 29 2 24 RESIDENTIAL © 2407.68 32 SERV. FUSE 3A, 30___ST.UGHTS _M/P_ SERVICES 2402.88 12 HRC FUSE 6A FULLLOAD CURRENT FORTX1CIRCUITS (A) 448 448 428 * pRoposet INSFORMER CURRENT RATING - 500K / (415*1.732) * 97 = 667A * FULLLOAE {ED FOR TK1 RETICULATION = 448A * FULLLOAD RATING OF PROPOSED S0OKVA TX = 667A PERCENTAGE TRANSFORMER @ FULLLOAD = 448A / 667A * 100 = 68.0%

You might also like