Heat Shrink MV Terminations Heat Shrinkable Termination System for Cables Cy Ret) alg Universal Selection Procedure Simplified selection table allows quick selection based fon conductor cross. section and voltage class for either polymeric or MIND paper Insulated cables (For MI draining cll cables, contact your local representative) Simple modification codes permit easy specification of ‘optional accessory kits Enhanced range-taking ability means that one kit fits more conductor sizes, reducing stocking requirements + Unlimited shelf life allows stocking of economic quantities without product spoilage ‘Simplified Cable Preparation Improved treatment of screen ccut back is compatible with all state of the art screen removal techniques No tap required No. polishing of polymeric insulation surface + No special preparation of sectored, or eccentric conductors, or of cable that is curved after unreeling from the cable drum + Cable preparation steps are simiiar to those for Raychem Joints ing of insulation ‘Simplified Installation Components are lightweight, ‘and non-shattering CClear instruction sheets Common installation procedure for polymeric and MIND paper cables Factory engineered kit permits rapid on-site installation te.com/energy + No mechanical stress at insulation screen cutback + Termination accommodates same bending radius as cable + Visual confirmation of correct assembly sequence possible after installation + Rain skirts can be installed to allow either top or bottom feed + No. soldering of earthing accessories required Outstanding Long-Term Reliability + Fully sealed against water ingress from the environment for from within the conductor strands + Polymeric materials load eycle with the cable without mechanically stressing termination components and sealants + Unsurpassed performance in polluted environments, proven over three decades EPKT/HVT =TE Page 73 Heat Shrink MV Terminations Terminations System Designer ‘This worksheet enables you to arrive at a part number for an EPKT termination, Choose one figure from the left-hand colurnn of each table, ‘Typical part number: EPKT- 17C3MOH3 Voltage (Umax) ———___ Cable size Number of cores Dielectric Location Length (S-core-cables) [jy fora kv A175 kV Dielectric of insulation type: [eo | erovrcor Length (only 3 Core) | of the terminated portion (all) [pe —___|______teresonm in noose and vinesoy | Ha for 1200 lone te.com/energy Page 74 Heat Shrink MV Terminations TIkV MIND Paper Seroened/Bolted Cables Single Core without Armour Catalogue Reference (ross Section ‘una come) STANDARD TAIL LENGTHS: Sold at sat of three co TIkV MIND Paper Screened/Belted Cables 3/Core with or without armour Catalogue Reference ‘cross Section outdoor one STANDARO TAIL LENGTHS: Con s/oore 22kV MIND Paper Screened/Belted Cables Single Core without Armour Catalogue Reference ‘cross Section outdoor one STANDARD TAIL LENGTHS: i/o Sold at sat of three 22kV MIND Paper Screened/Belted Cables 3/Core with C018 indo or without armour Catalogue Reference ‘cross Section outdoor one STANDARD TAIL LENGTHS: i/Core indoor = 140mm, Outs te.com/energy C018 not Page 75 Heat Shrink MV Terminations les Single Core without Armour Catalogue Reference: ‘cross Section Outdoor tom) STANDARD TAIL LENGTHS: Core indoor» 700mm Outsoor» 850m 2/Core indoor = 750mm Outdoor tof hee ‘33KV MIND Paper Screened Cables 3/Core with or without armour Catalogue Reference Catalogue Reference, Cross Section Indoor Outdoor comm) Ener ease aad 3570 PRT 6644-77 PRT 6520-07 95.50 EPKT 6650-97 [Epa 6926.97 185-300 ERT 66560 EPKT 6532-PT 400 STANDARD TAIL LENGTHS: Core indoor» 700mm Outsoor» 850m 5 [Care indoor = 750mm Outdoor = 800mm tecom/eneray pace «TE Heat Shrink MV Terminations Terminations System Designer ‘This worksheet enables you to arrive at a part number for an HVT termination. Choose one figure from the left-hand colurnn of each table, ‘Typical part number: HVTi- 7C3MH3 Location Veltage (Umax) cable size Number of cores oo Dielectric Lenath (3-core-cables) Location ‘of the termination Voltage in kV orld kV 4175 kV LLenath (only 3 Core) | of the terminated portion (aD) [a {or 650mm ong (rin for VAY outdoor and 6K ndoo ry for 1200 ln te.com/energy Page 77

You might also like