Installation Instruction

Sonnenschein@home Lithium

»The innovative high energy density,


fast charging battery«
Sonnenschein@home Lithium
Installation Instructions

Thank you! Explosion can cause serious


injury.
This product is applicable to EC
Thank you for purchasing the Sonnenschein@home directives (Europe Only). The
Lithium. product must not be disposed of
woth household waste,
countries must be disposed of
Before using the device, in an appropriate facility.
familiarize yourself with the Do not expose the energy
contents of this manual! storage unit to rain or moisture
or direct sunlight.

Keep these instructions readily


available for current and future users of
the Sonnenschein@home Lithium.

WARNINGS Battery System Manual


FIRE HAZARD!
Use the product only if connected with
To prevent fire, do not use the appropriate inverter as installed by a
the energy storage unit qualified technican.
near ignition sources or
flammable substances. Do
not cover. > Regularly check the module connection
If smoke appears, cables to ensure that they are free of
immediately turn off the cracks.
system! If possible > Make sure that the unit is not laying
seperate the energy on the cable
storage unit from the
inverter. > Ensure that cable does not come in
contact with water or sharp edges and
that the cables are not pinched.
SHOCK AND SHORT > Do not clean the energy storage unit with
CIRCUIT HAZARD! water. Use a dry cloth instead.
Use only supplied > Use the energy storage only when the
connection terminals. Check ambient temperature is between 32°F to
the cable for defects. If 113°F (0°C to +45°C) and in a well-
damaged, they must be ventilated, damp-free and dust-free
replaced. environment.
Never insert anything into the
energy storage unit!
Do not open the housing of Avoid Using...
the energy storage unit!
Never connect the positive > Outdoors
pole and the negative pole > in direct sunlight
directly with each other or by
another object! > in damp locations

Short Circuit!
Danger!

SYMBOLS
WARNING!
Possible electric shock, fire or
explosion
Sonnenschein@home Lithium
Installation Instructions

Initial Installation
Connecting the Energy Storage Unit
1. STEP ONE: 3. STEP THREE:
Connect the two cable of the Sonnen- Place the termination connector to the
schein@home Lithium. Connect ac- socket labeled "Internal" patch (intern).
cording to the Inverter manufacturer's If installing multiple units, place this
instructions (eg: SMA Sunny Island). connector in the last unit.
2. Red = Positive Terminal
3. BLACK = Negative

4. STEP FOUR:
2. STEP TWO: Use NH1 fuses, according to the
permissible loading currents of the
Connect the patch cable (RJ45) inverter (eg. SMA Sunny Island)
supplied by the inverter mfg. to the and close fuse isolators.
CAN connector position on the
storage unit (eg. SMA Sunny Island
Inverter)

Recommended Fuses;
SI3.0M-11: 80A
SI4.4M-11: 100A
SI6.0H-11: 160A
SI8.0H-11: 200A
Sonnenschein@home Lithium
Installation Instructions

5. STEP FIVE:

Technical Data
Energy Storage Sonnenschein Lithium

Nominalspannung 55.5 V
Capacity 121.5 Ah
Nominal Energy Content 6.8 kWh
Usuable Energy Content 5.44 kWh
Max. Discharge Current 300A (3sec.)
Protection IP 21
Turn On Possible Loading 0°C to +45°C
Operational Range 32°F to 113°F
Push button for 1 second, 2 cables
then release. Power Connection
50mm2 M8
Attention: Dimensions (25"x17.8"x16.5")
(WxLxH) 638x452x420mm
The inverter (eg. SMA Sunny Island) is
activated by the battery. Weight 209 lbs / 95 kg
This process takes about 30 seconds.
Upon succesful implementation both
LEDs blink at a steady flash.
You can now use the inverter (eg. SMA
Nameplate
Sunny Island) according to the
manufacturer's specifications.
Tel. +49 (0) 6042 81 0 www.gnb.com

Sonnenschein@home Lithium
Lithium-Ion Battery LIB48121B1XX11A
Nominale- / Lade-Spannung: 55.5 VDC / 61.5 V
Energie / Kapazität: 6.743 kWh / 121.5 Ah
max. Ladestrom: 90 A
max. Entladestrom: 300 A Batterie nur mit den von der GNB Industrial Power freigegebenen Wechselrichtern benutzen!
Gewicht: 95 kg / FW: V01.16 / PCB:12345678

To Turn Battery Off: Sicherheits-Ratschläge für Lithium-Ionen-Batterien


Nicht fallen lassen, nicht erhitzen oder anzünden. Nicht kurzschließen.
Nicht demontieren. Nicht in Flüssigkeiten tauchen, Gase können entweichen
oder es kann zerbrechen/reissen.

To turn the battery off, press the button Bitte die Ladeanweisungen einhalten.
Laden zwischen 0°C bis 45°C

for 10 seconds. The LED's will blink


Made in Germany
GEB 15-W29 / Art.: 24930-01 / F123456 / SN:0

quickly this lasts for two seconds actual image may vary
prior to turning off.

LED Indicator
LED Green LED Red
Parameter
ON FAST SLOW ON FAST SLOW

F01461 Service Mode X X

F01462 Fuse Error X

F01463 Error X X

F01464 Softstart Active X

F01465 No CAN Communication X X

F01466 OK / Operation X
Sonnenschein@home Lithium
Installation Instructions

Transport, storage and placement EC Declaration of conformity


> Choose a location that is not accessible
(Only for Europe)
by children or unauthorized. GNB Industrial Power - A division of Exide
Technologies • Im Thiergarten • 63654 Büdingen
> Place the energy storage unit in a dry
place with a temperature between 32°F to
113°F (0°C to +45°C). Do not expose to
direct sunlight. hereby declares that the energy storage unit
for model Sonnenschein@home Lithium,
> Always place the energy stoage unit on a follow the applicable regulations, and stan-
flat and dry place. dards. Conformity has been confirmed by an
independent test lab.
> Keep the distance between the energy Karlstein, Germany June 9, 2015.
storage unit and walls to 0.50" (15cm).
> If transporting, be aware of requirements
for class 9, dangerous goods for lithium
battery transportation.
> If damaged or dropped, do not use.
Isolate the unit immediately in case of
potential fire. Call GNB customer service.

Maintenance
Ensure that the energy storage unit is clean
and the contact points are secure and dry
before the energy storage unit is connected
to the system. Clean housing parts with a
clean, dry cloth.
> Excessively high temperatures within the
energy storage unit are cooled by a built-in
fan that is automatically activated.
> A constant red LED on the energy sto-
rage unit indicates the device needs to be
serviced.

Disposal
Battery (energy storage unit) may not be
disposed of with household waste. The
energy storage unit must be disposed at a
certified recycling facility or return to your
dealer.

For proper disposal and more information,


please contact your local waste dispo-
sal company or retailer from whom you
purchased the device.
Exide Technologies, with operations in more than 80 countries, is one of the world’s largest producers and recyclers of

Version 1.0 September 2016 Subjects to alterations


lead-acid batteries. Exide Technologies provides a comprehensive and customized range of stored electrical energy solutions.
Based on over 120 years of experience in the development of innovative technologies, Exide Technologies is an esteemed
partner of OEMs and serves the spare parts market for industrial and automotive applications.

GNB Industrial Power – A division of Exide Technologies – offers an extensive range of storage products and services, including
solutions for telecommunication systems, railway applications, mining, photovoltaic (solar energy), uninterrupted power
supply (UPS), electrical power generation and distribution, fork lifts and electric vehicles.

Exide Technologies takes pride in its commitment to a better environment. An integrated approach to manufacturing,
distributing and recycling of lead-acid batteries has been developed to ensure a safe and responsible life cycle for all of
its products.

GNB® INDUSTRIAL POWER devises enduring


energy concepts that convince with efficiency,
www.gnb.com flexibility and profitability.