You are on page 1of 2

F BM(D)X52-g Series Explosion-proof Illumination (Power) Distribution Box (IIC,tD)

Stainless steel part

Model Implication
B □ X 52 - g □ □/□ □ □ □ □ □ T Z W F2

Strong corrosion prevention


Outdoor (Optional)
Indicator/quantity (Optional)
Special requirement (Produced according to drawings provided by users)
Outlet Nos./ Thread specification(See P F/13)
Outlet direction
D-Top outlet X-Bottom outlet
Inlet Nos./ Thread specification(See P F/13)
Inlet direction
D-Top inlet X-Bottom inlet
K-With main switch/Rated current (Optional)
Branch current
Branch No.
L -Leakage protection (Optional)
D- Power maintenance (Optional)
Stainless steel enclosure
Design No.
Hanging type
M-Illumination
D-Power Patented products, counterfeit is forbidden
Explosion-proof

Applications Features
1. Can be used in Zone 1 and Zone 2, class IIA,IIB, IIC 1. The enclosure is welded by stainless steel plate, with corrosion resistance,
explosive atmosphere and Zone 21 and Zone 22 impact resistance and beautiful appearance, exposed stainless steel
fasteners;
flammable dust atmosphere; 2. The switch is operated out of the box and can be equipped with metal
2. Strong corrosion gas environment; handle and padlock as required;
3. Increased safety type enclosure, built-in explosion-proof anti-corrosion
3. Temperature class: T1~T6;
circuit breaker, Ex anti-corrosion motor protection switch, Ex surge
4. Indoor or outdoor (IP66); protector, Ex isolation switch, Ex signal lamp, etc. The parameters of
5. Can be used in the chemical, petroleum refining, various components are described in P G/26 ~35,P G/01 ~18;
4. Leakage protection can be installed as required;
petroleum exploitation, offshore platform, tankers, 5. The joint of body and cover adopts high temperature resistant and aging
military industry and other dangerous place. resistant silicone rubber sealing strip, which has good waterproof and
dust-proof performance.

Main technical parameters


Branch current Main switch Rated Corrosion- Inlet and Cable outer
current voltage Branch Pole Ex-mark Protection proof outlet dia.
1)
(A) No. grade 1)
(A) (V) No. grade thread (mm)

220
1, 2, 4, 6, ≤63 230 1P, 1P+N, Ex d eⅡC T4 Gb(80~250A) G1/2~2
2, 3, 6,
10, 16, 20, 25, ≤100 240 2P, 3P, Ex d eⅡC T6 Gb(1~63A) IP66 WF2* M16~M63 See P F/13
9, 12, …
32, 40, 50, 63 ≤250 380 4P, 3P+N Ex tD A21 IP66 T80℃ See P F/13)
415

1):The inlet and outlet are normally configured with G thread,BDM-7 cable gland.For other types of introduction devices, please see P C/17;
*: Specify when ordering.

F/01 www.helonex.com
BM(D)X52-g Series Explosion-proof Illumination (Power) Distribution Box (IIC、tD)
F

Stainless steel part


Main technical parameters of internal components
Explosion-proof anti-corrosion Explosion-proof and anti-corrosion Explosion-proof and anti-corrosive Explosion-proof and
Name motor protection switch anti-corrosive
circuit breaker (leakage) surge protector isolating switch

Type 8051-(L) 8054 8057 8065

220~250V 220~250V 220~250V 220~250V


Rated working voltage
380~415V 380~415V 380~415V 380~415V

0.1~0.16, 0.16~0.25, 0.25~0.4,


1, 2, 4, 6, 0.4~0.63, 0.63~1, 1-1.6, Maximum discharge current
Rated current(A) 10, 16, 20, 25, 1.6~2.5, 2.5~4, 4~6.3, 25, 40, 80, 125(180)
10, 20, 40, 65, 80, 120kA
32, 40, 50, 63 6.3~10, 10~16, 16~20,
20~25

Other parameters See P G/26(P G/28) See P G/32 See P G/35

Number of components built-in


Mounting components
Outline diagram
Type and
Size Type and Specification Qty Size Qty
Specification

Size 1 8051-1P 2 Pcs Size 6 8054 1 Pcs

Size 2 8051-2P 2 Pcs


1 1 8065-40 1 Pcs
0 0

Size 3 8051-3P 1 Pcs

8065-80 1 Pcs
Size 4 8051-4P 1 Pcs

Size 4 8051-L2P 2 Pcs

Size 1 8051-1P 6 Pcs Size 6 8054 3 Pcs

Size 2 8051-2P 4 Pcs


8065-40 2 Pcs
0
1

0
1

0
1

Size 3 8051-3P 3 Pcs

Size 4 8051-4P 3 Pcs 8065-80 1Pcs

Size 4 8051-L2P 3 Pcs


8065-125/180 1 Pcs
Size 5 8051-L3P(4P) 2 Pcs

Size 1 8051-1P 6Pcs X 2~3 Rows Size 6 8054 3 Pcs X 2~3 Rows
1 1 1

0 0 0

Size 2 8051-2P 4Pcs X 2~3 Rows


8065-40 2 Pcs X 2 Rows
0
1

0
1

0
1
Size 3 8051-3P 3Pcs X 2~3 Rows
8065-80 1 PcsX 2 Rows
Size 4 8051-4P 3Pcs X 2~3 Rows
1 1 1

0 0 0

Size 4 8051-L2P 3Pcs X 2~3 Rows 8065-125/180 1 Pcs X 2 Rows

Size 5 8051-L3P(4P) 2Pcs X 2~3 Rows

Note:Specific scheme can be based on user drawings requirements, when wearing padlock handle, the number of internal components can be reduced by one each.

www.helonex.com F/02

You might also like