You are on page 1of 19

RESIDENTIAL HOUSE

· Site Plan, Location Map & Notes


Construction of a 3 bedroom 1,680 sq ft
Residential Home with one full Master’s · Ground Floor Plan (Furniture)
Suite complete with walk-in closets, and · Ground Floor Plan (Dimension)
two bedroom with closets, separate · Front & Rear Elevations
Kitchen, Dinning & Living Room and Car
· Left & Right Elevations
Port
· Cross-section AA & BB
· Foundation Plan & Details
· Roof Plan & Details
Belize C.A. · Window & Door Schedules + Sill
2019
· Ground Floor Plumbing Plan
· Ground Floor Electrical Plan
· Septic Tank & Soak-away
· General Construction Notes
GEOVAHN MAGANA
GEVAHN MAGANA
100' EMAIL:
PROPERTY LINE maganageovahn@gmail.com
Architect Technician

13'-11" ..\Downloads\north.png
PROPERTY LINE

16'
30'-5"
SOAK AWAY SEPTIC PROJECT

9'-6" PROPOSE RESIDENTIAL


PROJECT.

ROAD
1. ALL STRUCTURAL CONCRETE TO BE
MINIMUM 3,500 PSI @ 28 DAYS (CYLINDER
75' STRENGTH) NOTES
20' 2. ALL STEEL REINFORCEMENT TO BE GRADE
60 PREPARED TO ASTM 615.
3. ALL WINDOW DIMENSIONS SHOWN ARE
ACTUAL SIZES BUT DOOR MEASURMENT Scale 1:150
SHOWN ARE ROUGH MASONRY OPENINGS.
4. FOUNDATION EXCAVATION MUST BE 26" MIN.
OR UNTIL FIRM SOIL IS ENCOUNTERED.
5. ALL PLUMBING TO BE OF SCH. 40 PVC LINES SHEET CONTENT
AND FITTINGS w/ WASTE CLEAN OUTS
PROVIDED AT EXIT FROM BUILDING. NO SITE PLAN
EXPOSED PLUMBING WILL BE PERMITTED.
6. LEVEL AND RAM BOTTOM OF ALL
EXCAVATION UNDER FOUNDATION DRAWN BY:
FOOTINGS BEFORE REINFORCEMENT
GEOVAHN MAGANA
PLACING.
7. APPROVED BACK-FILL TO BE COMPACTED IN
4'-5" 6" LAYERS. SHEET NO.
1
DATE
SERVICE ENTRANCE ROAD
2019

SITE PLAN COMPANY


GEVAHN MAGANA
B
EMAIL:
maganageovahn@gmail.com
Architect Technician

A B C D E F H
G
63'-5"

15'-8" 11'-1" 5'-9" 12'-8" 4'-7" 2'-5" 11'-3"


PROJECT
PROPOSE RESIDENTIAL
PROJECT.
1
A A'
Veranda FFL 1'

2 NOTES
2'

sto
Bathroom

FFL 1'
9'-2"

FFL 1'

Walk in Closet Bedroom 2


FFL 1'
Scale 1:100
FFL 1' Bathroom
Kitchen
REF
FFL 1'

4 Dining Area
FFL 1'

SHEET CONTENT
27'

FFL 1'

Master Bedroom
8'-4"

FLOOR PLAN
FFL 1'

Bedroom 1
DRAWN BY:
5 FFL 1'

FFL 1'

GEOVAHN MAGANA
5'-5"

Garage Porch
Living room
FFL 1'

SHEET NO.
6
FFL 1'

Working Area
2'

7 2
DATE

FLOOR PLAN B'


2019
COMPANY
GEVAHN MAGANA
11'-7" 11'-2" EMAIL:
maganageovahn@gmail.com
Architect Technician

7'

7'
2'-9" 2' 13'-6" 4' 4'-10" 3'-3" 2' 4'-6" 2' 2'-4"
1'-11"
2' 2'-6" 4' 4'-4" 4'-7"

4'-1"
2'-9"

7'-4"
PROJECT

sto
Bathroom
10'-9"

2'
FFL 1'
PROPOSE RESIDENTIAL
FFL 1' PROJECT.

3'-11"
Walk in Closet Bedroom 2
FFL 1'

FFL 1' Bathroom


5'-1" Kitchen
2'-4"
REF
FFL 1'

2'-9"

2'
2'-9" 2'-9"
FFL 1'

Dining Area

3'-8"
2'-9"

3'-10"
NOTES
6'

FFL 1'

Master Bedroom 2'-9" 5'-6"

5'-11"

2'-2" 2'
FFL 1' Scale 1:75
3'-3"

1'-10"
4"
Bedroom 1 8"
FFL 1'

3'-11" 4' 2' 4'


FFL 1'

2' 8'-9" 1'


Porch SHEET CONTENT
4'

Living room
FFL 1'
DIMENSION PLAN

4'
FFL 1'
11"

Working Area
DRAWN BY:

1'
GEOVAHN MAGANA
3'-5" 4' 5'-7" 8' 2'-7"
SHEET NO.
3
DATE
DIMENSION PLAN 2019
COMPANY
GEVAHN MAGANA
EMAIL:
maganageovahn@gmail.com
Architect Technician

PROJECT
PROPOSE RESIDENTIAL
PROJECT.

NOTES

Scale 1:75

SHEET CONTENT
FRONT VIEW

FRONT VIEW DRAWN BY:


GEOVAHN MAGANA

SHEET NO.
4
DATE
2019
COMPANY
GEVAHN MAGANA
EMAIL:
maganageovahn@gmail.com
Architect Technician

PROJECT
PROPOSE RESIDENTIAL
PROJECT.

30 ^ 27 ^
NOTES

Scale 1:75

SHEET CONTENT
REAR VIEW

DRAWN BY:

REAR VIEW GEOVAHN MAGANA

SHEET NO.
5
DATE
2019
COMPANY
GEVAHN MAGANA
EMAIL:
maganageovahn@gmail.com
Architect Technician

PROJECT
PROPOSE RESIDENTIAL
PROJECT.

NOTES

Scale 1:50

SHEET CONTENT
LEFT SIDE VIEW

DRAWN BY:
GEOVAHN MAGANA

LEFT SIDE VIEW


SHEET NO.
6
DATE
2019
COMPANY
GEVAHN MAGANA
EMAIL:
maganageovahn@gmail.com
Architect Technician

PROJECT
PROPOSE RESIDENTIAL
PROJECT.

NOTES

Scale 1:50

SHEET CONTENT
RIGHT SIDE VIEW

DRAWN BY:
GEOVAHN MAGANA

SHEET NO.
7

RIGHT SIDE VIEW DATE


2019
COMPANY
GEVAHN MAGANA
EMAIL:
maganageovahn@gmail.com
Architect Technician

21'- 5"

PROJECT
PROPOSE RESIDENTIAL
PROJECT.

11'

NOTES

Scale 1:75

FFL 1' Ground SHEET CONTENT

CROSS SECTION A/A'

DRAWN BY:
GEOVAHN MAGANA

SHEET NO.

CROSS SECTION A-A' 8


DATE
2019
COMPANY
GEVAHN MAGANA
EMAIL:
maganageovahn@gmail.com
Architect Technician

18'- 4"
15'- 11"

PROJECT
PROPOSE RESIDENTIAL
PROJECT.
11'

NOTES

Scale 1:50

FFL 1' Ground SHEET CONTENT


CROSS SECTION B/B'

DRAWN BY:
GEOVAHN MAGANA

SHEET NO.
9
DATE

CROSS SECTION B-B' 2019


COMPANY
GEVAHN MAGANA
EMAIL:
maganageovahn@gmail.com
Architect Technician

A B C F H
G
63'-5"

PROJECT
F1 F1

1 C1 C1 PROPOSE RESIDENTIAL
PROJECT.
6'-10"

F1 F1 F1 F1 F1
2 C1 C1 C1 C1 C1

NOTES
F1

F2

5" RC SLAB w/ #3
C1 C1 Scale 1:100
@10" B/W ON
DPM
27'

SHEET CONTENT
F1 F1 F1 F1
FOUNDATION PLAN
5 C1 C1 5" RC SLAB w/ #3 C1 C1
@10" B/W ON DRAWN BY:
DPM
F1 C1 F2 GEOVAHN MAGANA
6 C1 F1 F1 F1

7 C1 C1 C1 C1
SHEET NO.
10
DATE
2019
FOUNDATION PLAN COMPANY
F1 = FOOTING 1 COLUMN 1
Ground
C1 GEVAHN MAGANA
EMAIL:
1' 2'-6" 9" X 12" GROUND BEAM
maganageovahn@gmail.com
Architect Technician

6"
9" 6"
PROJECT
3" HOOK
PROPOSE RESIDENTIAL
PROJECT.

3'
EST. No. 2 @ 6 INCHES.
Scale 1:16 EST. No. 2 @ 6 INCHES.
F'c = 150 KG/CM2

NOTES
F2= FOOTING 2
Scale 1:10
Ground

BEAM 1
1' 2'-6"

9" X 12" GROUND BEAM


B1
SHEET CONTENT
FOOTING AND
GROUND BEAM DETAILS

8"
7.97

9" 4.49
DRAWN BY:
GEOVAHN MAGANA

6" SHEET NO.


11
3" HOOK
EST. No. 2 @ 3 INCHES. DATE

5'-8"
EST. No. 2 @ 6 INCHES.
Scale 1:16
F'c = 200 KG/CM2
2019
COMPANY
1X4 2 X 8 VALLEY
2 X 8 HIP PURLINS RAFTER
RAFTER GEVAHN MAGANA
EMAIL:
maganageovahn@gmail.com
Architect Technician

2X8
RAFTER

2 X 10 RIDGE
PROJECT
BOARD PROPOSE RESIDENTIAL
PROJECT.

NOTES

Scale 1:75
1 X 10 PLYCEM
FASCIA BOARD

SHEET CONTENT
ROOF FRAMING
PLAN
DRAWN BY:

BIRDS
MOUTH
ROOF FRAMING GEOVAHN MAGANA

SHEET NO.
12
1
3OF
ROOF DATE
RAFTER
BEAM 2019
COMPANY
CORE FILLED #3 BAR 6" BLOCK
6" BLOCK WINDOW BOTH SIDES OF WALL w/ #3
WALL FRAME WINDOW & DOOR @32"
GEVAHN MAGANA
1/2" SLOPE EMAIL:
RC SILL w/ 2 maganageovahn@gmail.com
#3 w/ #2 @8" Architect Technician
WINDOW

PROJECT

Veranda PROPOSE RESIDENTIAL


PROJECT.

W2 W3 W1 W1
D2
W2 W3 W3

W1 NOTES

Bathroom

D3
Scale 1:75

W1
D2 D2
D2

W4 D2 SHEET CONTENT
D2
DOOR AND
W1
WINDOW LAYOUT

W3 W3
DRAWN BY:
D1
GEOVAHN MAGANA
Porch
W3 SHEET NO.
W3 13
W3 W5 DATE
2019

DOOR & WINDOW LAYOUT COMPANY


GEVAHN MAGANA
EMAIL:
6' 4' maganageovahn@gmail.com
Architect Technician
2'

1'-6"
3'-6"
3'-6"

W4
W2

W3
PROJECT
8' 5'-6"
PROPOSE RESIDENTIAL
2' PROJECT.

1'-6"
3'-6"

6'-8"
NOTES
W1
W5

2'-4" 2'-9"

SHEET CONTENT
DOOR DOOR WINDOW
DETAIL
6'-8"

6'-8"

D2
& DRAWN BY:
GEOVAHN MAGANA
D3
WINDOW SHEET NO.
14
D1
SCHEDULE DATE
2019
COMPANY
GEVAHN MAGANA
EMAIL:
maganageovahn@gmail.com
to Septic to Soak Away Architect Technician

4" 2"

Veranda FFL 1'

PROJECT

sto
Bathroom
PROPOSE RESIDENTIAL
PROJECT.
Walk in Closet Bedroom 2 Bathroom
Kitchen
REF

Dining Area NOTES


Master Bedroom

Scale 1:75

Bedroom 1

SHEET CONTENT
Garage Porch
Living room
PLUMBING LAYOUT
Water line 34" pvc
Waste line 2" pvc
Working Area DRAWN BY:
Sewage waste line 4" pvc
GEOVAHN MAGANA
Hose mouth
SHEET NO.
shut off valve 15

PLUMBING LAYOUT DATE


2019
COMPANY
GEVAHN MAGANA
EMAIL:
maganageovahn@gmail.com
Architect Technician

220 W
WP WP

WP WP

sto
Bathroom

20 w OVERHANGED
FFL 1'

FFL 1'

Walk in Closet WP FFL 1'


PROJECT
Bedroom 2
FFL 1' Bathroom WP
LED
Kitchen PROPOSE RESIDENTIAL
REF LIGHTS PROJECT.
FFL 1'

Dining Area
FFL 1'
WP 180 w WATERPROOF
Master Bedroom
DUPLEX
NOTES
FFL 1'
WP OUTLET
220 W

Bedroom 1
WP

220 W
FFL 1'
180 w DUPLEX Scale 1:75
FFL 1'

Porch OUTLET
Living room
FFL 1'
15'-8"
FFL 1'

SHEET CONTENT
Working Area
20 w LED DOWN
LIGHT ELECTRICAL PLAN

DRAWN BY:
220 w DUPLEX GEOVAHN MAGANA
OUTLET
SHEET NO.
CONTROL PANEL 16

ELECTRICAL LAYOUT DATE


2019
COMPANY
10'-4" GEVAHN MAGANA
EMAIL:

0"
maganageovahn@gmail.com
Architect Technician

4 inch pipe 4 inch pipe

4'

5'
INLET OUTLET
MAN HOLE #3 BARS @ 10" 18" MANHOLE
18" X 18"
0"

4 inch pipe 4 inch pipe

PROJECT

4"
PROPOSE RESIDENTIAL
INLET
SEPTIC PLAN PROJECT.

4'-3"
NOTES

3' 2'-10" 2'-10" 6"


6"
4" 4"
6" GRADED STONES
SHEET CONTENT
10"

1'

SOAK AWAY X SECTION


4"
#3 BARS OUTLET SEPTIC AND
INLET 4 inch pipe
4 inch pipe
SOAK AWAY
DRAWN BY:
5'-5"

16" pipe
4'

plank GEOVAHN MAGANA

SHEET NO.
17
5"

#3 BARS @ 16"
DATE
2019

SOAK AWAY AND SEPTIC DETAIL COMPANY


1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL
1. MAIN POTABLE WATER PIPE TO BE 34 " PVC PIPE GEVAHN MAGANA
2. POTABLE WATER PIPE THAT LEADS TO ACCESSORIES TO APPLICABLE CODE EMAIL:
2. THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW maganageovahn@gmail.com
BE 34 " PVC PIPE ALL OFFSETS, BENDS AND BOXES REQUIRED TO MAKE A Architect Technician
3. DISCHARGE PIPES FROM WATER CLOSET KNOWN AS SOLID COMPLETE NEAT INSTALLATION IN ACCORDANCE WITH
WASTE PIPES TO BE 4" PVC APPLICABLE CODE
4. DISCHARGE PIPES FROM LAVATORIES KNOWN AS LIQUID 3. APPROVAL SHALL BE OBTAINED FROM STRUCTURAL
WASTE PIPES TO BE 2" PVC ENGINEER PRIOR TO CUTTING OR DRILLING ANY
5. CHANGES IN DIRECTION OF SOLID WASTE LINES TO BE AT STRUCTURAL SUPPORT MEMBER
45 DEGRESS 4. ALL CONDUCTORS TO BE COPPER UNLESS OTHER WISE
6. ALL FIXTURES SHALL HAVE A 21" ANGLE VALVE NOTED
7. CHANGE IN DIRECTIONS SHOULD BE FITTED WITH A CLEAN PROJECT
5. ALL CONDUCTORS SHALL BE RUN IN CONDUIT
OUT POINT THAT COULD BE EASILY ACCESSED (NON-METALLIC TYPE) NMC CABLE IS PERMITTED AS AN PROPOSE RESIDENTIAL
PROJECT.
OPTION, IF PVC SCH 40 IS USED FOR UNDERGROUND
FEEDERS ONLY, AN EQUIPMENT GROUND CONDUCTOR
MUST BE INSTALLED AND CONDUIT SIZE INCREASE AS
REQUIRED.
6. ALL NON POWER RELATED WIRING CAN BE DONE RUN IN NOTES
CEILING PLENUM WITHOUT CONDUIT
7. ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN
ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER
RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS
8. ALL CABLES SHALL BE RUN WITHOUT SPLICES EXCEPT
OTHERWISE INDICATED SHEET CONTENT
9. ALL WORK SHALL BE DONE IN A NEAT AND PROFESSIONAL
GENERAL NOTES
MANNER
10. ALL ROUGH IN DIMENSIONS ARE TO CENTER LINE OF DRAWN BY:
DEVICE UNLESS OTHER WISE NOTED
GEOVAHN MAGANA
11. ALL CONDUCTOR SPLICES IN EXTERIOR LOCATED PULL
BOXES EXPOSED TO THE WEATHER TO BE WEATHER SHEET NO.
SEALED 18
12. CONTRACTOR IS ALLOWED TO REARRANGE THE
DISTRIBUTION OF THE ELECTRICAL LOADS CONNECTED TO DATE
THE BRANCH CIRCUITS IN THE FIELD, AS LONG AS THE 2019
LOAD IS BALANCED AND INDEPENDENT CIRCUIT LOADING
COMPANY
IS IN COMPLIANCE WITH LOCAL COD