You are on page 1of 9

Geotechnical Design using SPT Values

Location: BH-5
Pile Capacity (kN)
Round Pile φ = 150 mm Skin Area, As= 0.471 Base Area, Ab = 0.018 m2
Skin Friction (FoS) = 2.0 0 200 400 600
End Bearing (FoS) = 3.0 0

Unit Skin Skin End Bear at


Cumulative End Bear at Pile Ultimate 2
Depth Interval Avg SPT Fric, fs = 2N Fric, depth, End Bear, Qb/FoS
Skin Fric, Fs depth, Qb Capacity, Qult =
(m) Value, N @ 100 Fs/FoS qb=min(400N, (kN)
(kN) (kN) Fs+Qb (kN)
(kN/m2) (kN) 1000) (kN/m2) 4
0 0 0 0.0 0.0 0.0 0.0 0.0 0.0
3 33 66 46.7 46.7 0.0 0.0 0.0 46.7 6
6.5 38 76 62.7 109.3 0.0 0.0 0.0 109.3
8 22 44 15.6 124.9 0.0 0.0 0.0 124.9 8
18 20 40 94.2 219.1 0.0 0.0 0.0 219.1

Depth (m)
10

12

14

16

18

20

Allowable Pile Capacity = 200.0 kN Depth required = 18 m


Geotechnical Design using SPT Values

Location: BH-5
Pile Capacity (kN)
Round Pile φ = 250 mm Skin Area, As= 0.785 Base Area, Ab = 0.049 m2
Skin Friction (FoS) = 2.0 0 200 400 600
End Bearing (FoS) = 3.0 0

Unit Skin Skin End Bear at


Cumulative End Bear at Pile Ultimate 2
Depth Interval Avg SPT Fric, fs = 2N Fric, depth, End Bear, Qb/FoS
Skin Fric, Fs depth, Qb Capacity, Qult =
(m) Value, N @ 100 Fs/FoS qb=min(400N, (kN)
(kN) (kN) Fs+Qb (kN)
(kN/m2) (kN) 1000) (kN/m2) 4
0 0 0 0.0 0.0 0.0 0.0 0.0 0.0
3 33 66 129.6 129.6 0.0 0.0 0.0 129.6 6
6.5 38 76 104.5 234.0 0.0 0.0 0.0 234.0
8 22 44 25.9 260.0 0.0 0.0 0.0 260.0 8
18 20 40 157.1 417.0 0.0 0.0 0.0 417.0

Depth (m)
10

12

14

16

18

20

Allowable Pile Capacity = 400.0 kN Depth required = 18 m


Geotechnical Design using SPT Values

Location: BH-6
Pile Capacity (kN)
Round Pile φ = 150 mm Skin Area, As= 0.471 Base Area, Ab = 0.018 m2
Skin Friction (FoS) = 2.0 0 200 400 600
End Bearing (FoS) = 3.0 0

Unit Skin Skin End Bear at


Cumulative End Bear at Pile Ultimate 2
Depth Interval Avg SPT Fric, fs = 2N Fric, depth, End Bear, Qb/FoS
Skin Fric, Fs depth, Qb Capacity, Qult =
(m) Value, N @ 100 Fs/FoS qb=min(400N, (kN)
(kN) (kN) Fs+Qb (kN)
(kN/m2) (kN) 1000) (kN/m2) 4
0 0 0 0.0 0.0 0.0 0.0 0.0 0.0
5 28 56 66.0 66.0 0.0 0.0 0.0 66.0 6
8 40 80 56.5 122.5 0.0 0.0 0.0 122.5
18 24 48 113.1 235.6 0.0 0.0 0.0 235.6 8

Depth (m)
10

12

14

16

18

20

Allowable Pile Capacity = 200.0 kN Depth required = 18 m


Geotechnical Design using SPT Values

Location: BH-6
Pile Capacity (kN)
Round Pile φ = 250 mm Skin Area, As= 0.785 Base Area, Ab = 0.049 m2
Skin Friction (FoS) = 2.0 0 200 400 600
End Bearing (FoS) = 3.0 0

Unit Skin Skin End Bear at


Cumulative End Bear at Pile Ultimate 2
Depth Interval Avg SPT Fric, fs = 2N Fric, depth, End Bear, Qb/FoS
Skin Fric, Fs depth, Qb Capacity, Qult =
(m) Value, N @ 100 Fs/FoS qb=min(400N, (kN)
(kN) (kN) Fs+Qb (kN)
(kN/m2) (kN) 1000) (kN/m2) 4
0 0 0 0.0 0.0 0.0 0.0 0.0 0.0
5 28 56 110.0 110.0 0.0 0.0 0.0 110.0 6
8 40 80 94.2 204.2 0.0 0.0 0.0 204.2
18 24 48 188.5 392.7 0.0 0.0 0.0 392.7 8

Depth (m)
10

12

14

16

18

20

Allowable Pile Capacity = 400.0 kN Depth required = 18 m


Geotechnical Design using SPT Values

Location: BH-7
Pile Capacity (kN)
Round Pile φ = 150 mm Skin Area, As= 0.471 Base Area, Ab = 0.018 m2
Skin Friction (FoS) = 2.0 0 200 400 600
End Bearing (FoS) = 3.0 0

Unit Skin Skin End Bear at


Cumulative End Bear at Pile Ultimate 2
Depth Interval Avg SPT Fric, fs = 2N Fric, depth, End Bear, Qb/FoS
Skin Fric, Fs depth, Qb Capacity, Qult =
(m) Value, N @ 100 Fs/FoS qb=min(400N, (kN)
(kN) (kN) Fs+Qb (kN)
(kN/m2) (kN) 1000) (kN/m2) 4
0 0 0 0.0 0.0 0.0 0.0 0.0 0.0
6.5 23 46 93.9 93.9 0.0 0.0 0.0 93.9 6
9.5 19 38 26.9 120.8 0.0 0.0 0.0 120.8
12.5 22 44 31.1 151.9 0.0 0.0 0.0 151.9 8
14 18 36 12.7 164.6 0.0 0.0 0.0 164.6

Depth (m)
18 25 50 47.1 211.7 0.0 0.0 0.0 211.7
10

12

14

16

18

20

Allowable Pile Capacity = 200.0 kN Depth required = 18 m


Geotechnical Design using SPT Values

Location: BH-7
Pile Capacity (kN)
Round Pile φ = 250 mm Skin Area, As= 0.785 Base Area, Ab = 0.049 m2
Skin Friction (FoS) = 2.0 0 200 400 600
End Bearing (FoS) = 3.0 0

Unit Skin Skin End Bear at


Cumulative End Bear at Pile Ultimate 2
Depth Interval Avg SPT Fric, fs = 2N Fric, depth, End Bear, Qb/FoS
Skin Fric, Fs depth, Qb Capacity, Qult =
(m) Value, N @ 100 Fs/FoS qb=min(400N, (kN)
(kN) (kN) Fs+Qb (kN)
(kN/m2) (kN) 1000) (kN/m2) 4
0 0 0 0.0 0.0 0.0 0.0 0.0 0.0
6.5 23 46 195.7 195.7 0.0 0.0 0.0 195.7 6
9.5 19 38 44.8 240.5 0.0 0.0 0.0 240.5
12.5 22 44 51.8 292.3 0.0 0.0 0.0 292.3 8
14 18 36 21.2 313.5 0.0 0.0 0.0 313.5

Depth (m)
18 25 50 78.5 392.0 0.0 0.0 0.0 392.0
10

12

14

16

18

20

Allowable Pile Capacity = 400.0 kN Depth required = 18 m


Geotechnical Design using SPT Values

Location: BH-5
Pile Capacity (kN)
Square Pile = 150 mm Skin Area, As= 0.600 Base Area, Ab = 0.023 m2
Skin Friction (FoS) = 2.0 0 200 400 600
End Bearing (FoS) = 3.0 0

Unit Skin Skin End Bear at


Cumulative End Bear at Pile Ultimate
Depth Interval Avg SPT Fric, fs = 2N Fric, depth, End Bear, Qb/FoS
Skin Fric, Fs depth, Qb Capacity, Qult = 1
(m) Value, N @ 100 Fs/FoS qb=min(400N, (kN)
(kN) (kN) Fs+Qb (kN)
(kN/m2) (kN) 1000) (kN/m2)
0 0 0 0.0 0.0 0.0 0.0 0.0 0.0
3 33 66 59.4 59.4 0.0 0.0 0.0 59.4 2
6 38 76 68.4 127.8 0.0 0.0 0.0 127.8

Depth (m)
4

Allowable Pile Capacity = 80.0 kN Depth required = 6 m


Geotechnical Design using SPT Values

Location: BH-6
Pile Capacity (kN)
Square Pile = 150 mm Skin Area, As= 0.600 Base Area, Ab = 0.023 m2
Skin Friction (FoS) = 2.0 0 200 400 600
End Bearing (FoS) = 3.0 0

Unit Skin Skin End Bear at


Cumulative End Bear at Pile Ultimate
Depth Interval Avg SPT Fric, fs = 2N Fric, depth, End Bear, Qb/FoS
Skin Fric, Fs depth, Qb Capacity, Qult = 1
(m) Value, N @ 100 Fs/FoS qb=min(400N, (kN)
(kN) (kN) Fs+Qb (kN)
(kN/m2) (kN) 1000) (kN/m2)
0 0 0 0.0 0.0 0.0 0.0 0.0 0.0
6 28 56 100.8 100.8 0.0 0.0 0.0 100.8 2

Depth (m)
4

Allowable Pile Capacity = 80.0 kN Depth required = 6 m


Geotechnical Design using SPT Values

Location: BH-7
Pile Capacity (kN)
Square Pile = 150 mm Skin Area, As= 0.600 Base Area, Ab = 0.023 m2
Skin Friction (FoS) = 2.0 0 200 400 600
End Bearing (FoS) = 3.0 0

Unit Skin Skin End Bear at


Cumulative End Bear at Pile Ultimate
Depth Interval Avg SPT Fric, fs = 2N Fric, depth, End Bear, Qb/FoS
Skin Fric, Fs depth, Qb Capacity, Qult = 1
(m) Value, N @ 100 Fs/FoS qb=min(400N, (kN)
(kN) (kN) Fs+Qb (kN)
(kN/m2) (kN) 1000) (kN/m2)
0 0 0 0.0 0.0 0.0 0.0 0.0 0.0
6 20 40 96.0 96.0 0.0 0.0 0.0 96.0 2

Depth (m)
4

Allowable Pile Capacity = 80.0 kN Depth required = 6 m

You might also like