A320 FAMILY DIFFERENCES BETWEEN APU TYPES

DIFFERENCES Honeywell 131-9 Honeywell GTCP36-300 APS 3200


TURBINE STAGES 2 Stage Axial Flow Turbine Single Stage Radial Flow Turbine 2 Stage Axial Flow Turbine
IGV VANE NUMBER IGV Vanes: 16 14 IGV Vanes 24 IGV Vanes
STARTER DISCONNECTION N RMP RPM: 50% RPM: 50% RPM: 55%
IGNITION DURING START Between 0%-60% Between 7% - 95% Between 0%-55%
IGNITOR NUMBER 1 IGN BOX 1 IGN PLUG 1 BOX 1 PLUG 1 BOX 2 LEADS 2 IGN PLUG
FUEL OPERATED VALVES IGV Act. & Surge Control Valve IGV Act. Only IGV Act & Bleed/Surge Ctl Valve
PMG N/A N/A PMG for ECB Backup Supply
FUEL NOZZLES & MANIFOLDS 10 Fuel Nozzels, 2 Manifolds 6 Dual Fuel Nozzels, 2 Manifolds 3 Pilot + 6 Main Fuel Injectors
FUEL SEQUENCE Primary Manifold First, then at 125 At %7 N Primary 7.5Psi, then at 150 at 20 Psi Pilot Nozzels, then Both in
Psi Secondary Manifold Psi Secondary Manifold Normal Operation
OIL TANK QUANTITY 6.26 L 5.71 L 5.21 L
OIL HEATER OPERATION Below 16 C & Off Over 49 C Below 21 C - Off Over 43 C N\A
OIL COOLER TERMAL BYPASS VALVE Open Below 60 C Open below 60, Fully Closed 77 C N\A
COOLING DOWN PERIOD 60 Sec. 60 Sec. 120 Sec.
PROTECTION SHUTDOWN Gearbox HOT : 162 C, LOP : 33 Psi Gearbox HOT : 152 C, LOP : 35 Psi, Gearbox HOT : 135 C, LOP : 35 Psi,
AC Generator HOT 185 C AC Generator HOT 180 C
BLEED VALVE TYPES Bleed valve pneumatically Operated Bleed valve pneumatically Bleed\Surge Control Valve Fuel
Solenid controlled, Surge Valve Fuel Operated Solenid controlled, Surge Operated Actuator TM Controlled
Operated TM Controlled. Valve Pneumatically Operated TM
Controlled