You are on page 1of 4

PVSYST 7.0.

11 21/09/20 Page 1/4

Grid-Connected System: Simulation parameters


Project : New Project
Geographical Site Goianul Nou Country Republic Of Moldova
Situation Latitude 47.11° N Longitude 28.90° E
Time defined as Legal Time Time zone UT+2 Altitude 155 m
Albedo 0.20
Meteo data: Goianul Nou Meteonorm 7.3 (1991-2010), Sat=100% - Synthetic

PVsyst TRIAL
Simulation variant :

Simulation parameters
Collector Plane Orientation
New simulation variant
Simulation date

System type
Tilt
21/09/20 09h51

No 3D scene defined, no shadings


40° Azimuth 0°
Models used Transposition Perez Diffuse Perez, Meteonorm
Circumsolar separate
Horizon Free Horizon
Near Shadings No Shadings
User's needs : Unlimited load (grid)

PVsyst TRIAL
PV Array Characteristics
PV module
Original PVsyst database
Number of PV modules
Total number of PV modules
Array global power
Si-mono Model
Manufacturer
In series
nb. modules
Nominal (STC)
JAM60-S09-320-PR
JA Solar
18 modules
18
5.76 kWp
In parallel
Unit Nom. Power
At operating cond.
1 strings
320 Wp
5.23 kWp (50°C)
Array operating characteristics (50°C) U mpp 541 V I mpp 9.7 A
Total area Module area 29.7 m²

Inverter Model SUN2000-5KTL-M1


Custom parameters definition Manufacturer Huawei Technologies
Characteristics Unit Nom. Power 5.00 kWac Oper. Voltage 140-980 V
Max. power (=>60°C) 5.50 kWac

PVsyst TRIAL
Inverter pack Total power 5.0 kWac Pnom ratio 1.15
Nb. of inverters 1 units
Total Total power 5 kWac Pnom ratio 1.15

PV Array loss factors


Thermal Loss factor Uc (const) 20.0 W/m²K Uv (wind) 0.0 W/m²K / m/s
Wiring Ohmic Loss Global array res. 938 mΩ Loss Fraction 1.5 % at STC
Module Quality Loss Loss Fraction -0.8 %
Module mismatch losses Loss Fraction 2.0 % at MPP
Strings Mismatch loss Loss Fraction 0.10 %
Incidence effect (IAM): Fresnel smooth glass, n = 1.526

PVsyst TRIAL
0° 30° 50° 60° 70° 75° 80° 85° 90°
1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst Evaluation mode


PVSYST 7.0.11 21/09/20 Page 2/4

Grid-Connected System: Main results


Project : New Project
Simulation variant : New simulation variant
Main system parameters System type No 3D scene defined, no shadings
PV Field Orientation tilt 40° azimuth 0°
PV modules Model JAM60-S09-320-PR Pnom 320 Wp
PV Array Nb. of modules 18 Pnom total 5.76 kWp
Inverter Model SUN2000-5KTL-M1 Pnom 5.00 kW ac

PVsyst TRIAL
User's needs Unlimited load (grid)

Main simulation results


System Production Produced Energy 7.38 MWh/year Specific prod. 1282 kWh/kWp/year
Performance Ratio PR 87.04 %

Normalized productions (per installed kWp): Nominal power 5.76 kWp Performance Ratio PR

7 1.0
PR: Performance Ratio (Yf / Yr) : 0.870
0.9
Lc: Collection Loss (PV-array losses) 0.43 kWh/kWp/day
6
Ls: System Loss (inverter, ...) 0.09 kWh/kWp/day
0.8
[kWh/kWp/day]

Yf: Produced useful energy (inverter output) 3.51 kWh/kWp/day


5 0.7
Performance Ratio PR

0.6
4
Energy

0.5

PVsyst TRIAL
3
0.4
Normalized

2 0.3

0.2
1
0.1

0 0.0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

New simulation variant


Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² MWh MWh ratio

PVsyst TRIAL
January 32.8 20.08 -1.29 58.9 57.8 0.332 0.320 0.943
February 46.3 28.55 -0.32 68.8 67.3 0.382 0.370 0.933
March 94.8 48.62 4.56 125.9 122.8 0.677 0.661 0.911
April 133.7 66.21 10.55 150.4 146.1 0.782 0.763 0.881
May 174.8 83.26 17.02 173.2 167.9 0.876 0.856 0.857
June 187.7 81.63 20.06 176.6 170.9 0.878 0.858 0.843
July 193.3 80.90 23.13 187.2 181.4 0.919 0.897 0.832
August 165.5 73.04 22.53 176.9 171.5 0.871 0.850 0.835
September 112.2 52.02 16.00 139.8 135.9 0.712 0.695 0.863
October 72.7 35.69 10.90 107.3 105.0 0.562 0.547 0.885
November 37.4 21.45 5.22 63.9 62.7 0.346 0.334 0.907
December 23.8 15.00 -0.09 43.7 42.8 0.243 0.232 0.921
Year 1275.0 606.45 10.75 1472.7 1432.0 7.580 7.383 0.870

PVsyst TRIAL
Legends: GlobHor Global horizontal irradiation GlobEff Effective Global, corr. for IAM and shadings
DiffHor Horizontal diffuse irradiation EArray Effective energy at the output of the array
T_Amb T amb. E_Grid Energy injected into grid
GlobInc Global incident in coll. plane PR Performance Ratio

PVsyst Evaluation mode


PVSYST 7.0.11 21/09/20 Page 3/4

Grid-Connected System: Special graphs


Project : New Project
Simulation variant : New simulation variant
Main system parameters System type No 3D scene defined, no shadings
PV Field Orientation tilt 40° azimuth 0°
PV modules Model JAM60-S09-320-PR Pnom 320 Wp
PV Array Nb. of modules 18 Pnom total 5.76 kWp
Inverter Model SUN2000-5KTL-M1 Pnom 5.00 kW ac

PVsyst TRIAL
User's needs Unlimited load (grid)

Daily Input/Output diagram

50
Values from 01/01 to 31/12

40
[kWh/day]
grid

30

PVsyst TRIAL
into
injected

20
Energy

10

0
0 2 4 6 8 10
Global incident in coll. plane [kWh/m²/day]

System Output Power Distribution

PVsyst TRIAL 200

180

160
Values from 01/01 to 31/12
Bin]
/

140
[kWh

120
grid

100
into
injected

80

PVsyst TRIAL 60
Energy

40

20

0
0 1 2 3 4 5
Power injected into grid [kW]

PVsyst Evaluation mode


PVSYST 7.0.11 21/09/20 Page 4/4

Grid-Connected System: Loss diagram


Project : New Project
Simulation variant : New simulation variant
Main system parameters System type No 3D scene defined, no shadings
PV Field Orientation tilt 40° azimuth 0°
PV modules Model JAM60-S09-320-PR Pnom 320 Wp
PV Array Nb. of modules 18 Pnom total 5.76 kWp
Inverter Model SUN2000-5KTL-M1 Pnom 5.00 kW ac

PVsyst TRIAL
User's needs Unlimited load (grid)

Loss diagram over the whole year

1275 kWh/m² Global horizontal irradiation


+15.5% Global incident in coll. plane

-2.77% IAM factor on global

1432 kWh/m² * 30 m² coll. Effective irradiation on collectors


efficiency at STC = 19.40% PV conversion

8.25 MWh Array nominal energy (at STC effic.)


-0.90% PV loss due to irradiance level
-5.15% PV loss due to temperature

PVsyst TRIAL
+0.75% Module quality loss

-2.10% Mismatch loss, modules and strings


-0.94% Ohmic wiring loss
7.58 MWh Array virtual energy at MPP
-2.26% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
-0.34% Night consumption
7.38 MWh Available Energy at Inverter Output
7.38 MWh Energy injected into grid

PVsyst TRIAL

PVsyst TRIAL
PVsyst Evaluation mode

You might also like