Professional Documents
Culture Documents
PVsyst TRIAL
Simulation variant :
Simulation parameters
Collector Plane Orientation
New simulation variant
Simulation date
System type
Tilt
21/09/20 09h51
PVsyst TRIAL
PV Array Characteristics
PV module
Original PVsyst database
Number of PV modules
Total number of PV modules
Array global power
Si-mono Model
Manufacturer
In series
nb. modules
Nominal (STC)
JAM60-S09-320-PR
JA Solar
18 modules
18
5.76 kWp
In parallel
Unit Nom. Power
At operating cond.
1 strings
320 Wp
5.23 kWp (50°C)
Array operating characteristics (50°C) U mpp 541 V I mpp 9.7 A
Total area Module area 29.7 m²
PVsyst TRIAL
Inverter pack Total power 5.0 kWac Pnom ratio 1.15
Nb. of inverters 1 units
Total Total power 5 kWac Pnom ratio 1.15
PVsyst TRIAL
0° 30° 50° 60° 70° 75° 80° 85° 90°
1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000
PVsyst TRIAL
User's needs Unlimited load (grid)
Normalized productions (per installed kWp): Nominal power 5.76 kWp Performance Ratio PR
7 1.0
PR: Performance Ratio (Yf / Yr) : 0.870
0.9
Lc: Collection Loss (PV-array losses) 0.43 kWh/kWp/day
6
Ls: System Loss (inverter, ...) 0.09 kWh/kWp/day
0.8
[kWh/kWp/day]
0.6
4
Energy
0.5
PVsyst TRIAL
3
0.4
Normalized
2 0.3
0.2
1
0.1
0 0.0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
PVsyst TRIAL
January 32.8 20.08 -1.29 58.9 57.8 0.332 0.320 0.943
February 46.3 28.55 -0.32 68.8 67.3 0.382 0.370 0.933
March 94.8 48.62 4.56 125.9 122.8 0.677 0.661 0.911
April 133.7 66.21 10.55 150.4 146.1 0.782 0.763 0.881
May 174.8 83.26 17.02 173.2 167.9 0.876 0.856 0.857
June 187.7 81.63 20.06 176.6 170.9 0.878 0.858 0.843
July 193.3 80.90 23.13 187.2 181.4 0.919 0.897 0.832
August 165.5 73.04 22.53 176.9 171.5 0.871 0.850 0.835
September 112.2 52.02 16.00 139.8 135.9 0.712 0.695 0.863
October 72.7 35.69 10.90 107.3 105.0 0.562 0.547 0.885
November 37.4 21.45 5.22 63.9 62.7 0.346 0.334 0.907
December 23.8 15.00 -0.09 43.7 42.8 0.243 0.232 0.921
Year 1275.0 606.45 10.75 1472.7 1432.0 7.580 7.383 0.870
PVsyst TRIAL
Legends: GlobHor Global horizontal irradiation GlobEff Effective Global, corr. for IAM and shadings
DiffHor Horizontal diffuse irradiation EArray Effective energy at the output of the array
T_Amb T amb. E_Grid Energy injected into grid
GlobInc Global incident in coll. plane PR Performance Ratio
PVsyst TRIAL
User's needs Unlimited load (grid)
50
Values from 01/01 to 31/12
40
[kWh/day]
grid
30
PVsyst TRIAL
into
injected
20
Energy
10
0
0 2 4 6 8 10
Global incident in coll. plane [kWh/m²/day]
180
160
Values from 01/01 to 31/12
Bin]
/
140
[kWh
120
grid
100
into
injected
80
PVsyst TRIAL 60
Energy
40
20
0
0 1 2 3 4 5
Power injected into grid [kW]
PVsyst TRIAL
User's needs Unlimited load (grid)
PVsyst TRIAL
+0.75% Module quality loss
PVsyst TRIAL
PVsyst TRIAL
PVsyst Evaluation mode