11 21/09/20 Page 1/4

Grid-Connected System: Simulation parameters


Project : New Project
Geographical Site Goianul Nou Country Republic Of Moldova
Situation Latitude 47.11° N Longitude 28.90° E
Time defined as Legal Time Time zone UT+2 Altitude 155 m
Albedo 0.20
Meteo data: Goianul Nou Meteonorm 7.3 (1991-2010), Sat=100% - Synthetic

PVsyst TRIAL
Simulation variant :

Simulation parameters
Collector Plane Orientation
New simulation variant
Simulation date

System type
Tilt
21/09/20 09h56

No 3D scene defined, no shadings


40° Azimuth 0°
Models used Transposition Perez Diffuse Perez, Meteonorm
Circumsolar separate
Horizon Free Horizon
Near Shadings No Shadings
User's needs : monthly values

PVsyst TRIAL
Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. Year
496 496 496 496 496 496 496 496 496 496 496 496 5952 kWh/mth

PV Array Characteristics
PV module Si-mono Model JAM60-S09-320-PR
Original PVsyst database Manufacturer JA Solar
Number of PV modules In series 20 modules In parallel 1 strings
Total number of PV modules nb. modules 20 Unit Nom. Power 320 Wp
Array global power Nominal (STC) 6.40 kWp At operating cond. 5.81 kWp (50°C)
Array operating characteristics (50°C) U mpp 601 V I mpp 9.7 A
Total area Module area 33.0 m²

PVsyst TRIAL
Inverter
Custom parameters definition
Characteristics

Inverter pack
Model
Manufacturer
Unit Nom. Power
Max. power (=>60°C)
Total power
Nb. of inverters
SUN2000-5KTL-M1
Huawei Technologies
5.00 kWac
5.50 kWac
5.0 kWac
1 units
Oper. Voltage

Pnom ratio
140-980 V

1.28

Total Total power 5 kWac Pnom ratio 1.28

PV Array loss factors


Thermal Loss factor Uc (const) 20.0 W/m²K Uv (wind) 0.0 W/m²K / m/s
Wiring Ohmic Loss Global array res. 1042 mΩ Loss Fraction 1.5 % at STC

PVsyst TRIAL
Module Quality Loss Loss Fraction -0.8 %
Module mismatch losses Loss Fraction 2.0 % at MPP
Strings Mismatch loss Loss Fraction 0.10 %
Incidence effect (IAM): Fresnel smooth glass, n = 1.526
0° 30° 50° 60° 70° 75° 80° 85° 90°
1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst Evaluation mode


PVSYST 7.0.11 21/09/20 Page 2/4

Grid-Connected System: Main results


Project : New Project
Simulation variant : New simulation variant
Main system parameters System type No 3D scene defined, no shadings
PV Field Orientation tilt 40° azimuth 0°
PV modules Model JAM60-S09-320-PR Pnom 320 Wp
PV Array Nb. of modules 20 Pnom total 6.40 kWp
Inverter Model SUN2000-5KTL-M1 Pnom 5.00 kW ac

PVsyst TRIAL
User's needs monthly values Global 5952 kWh/year

Main simulation results


System Production Produced Energy 8.21 MWh/year Specific prod. 1282 kWh/kWp/year
Performance Ratio PR 87.08 % Solar Fraction SF 38.03 %

Normalized productions (per installed kWp): Nominal power 6.40 kWp Performance Ratio PR

7 1.0
PR: Performance Ratio (Yf / Yr) : 0.871
0.9
Lc: Collection Loss (PV-array losses) 0.43 kWh/kWp/day
6
Ls: System Loss (inverter, ...) 0.09 kWh/kWp/day
0.8
[kWh/kWp/day]

Yf: Produced useful energy (inverter output) 3.51 kWh/kWp/day


5 0.7
Performance Ratio PR

0.6
4
Energy

0.5

PVsyst TRIAL
3
0.4
Normalized

2 0.3

0.2
1
0.1

0 0.0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

New simulation variant


Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_User E_Solar E_Grid EFrGrid
kWh/m² kWh/m² °C kWh/m² kWh/m² MWh MWh MWh MWh MWh

PVsyst TRIAL
January 32.8 20.08 -1.29 58.9 57.8 0.369 0.496 0.120 0.236 0.376
February 46.3 28.55 -0.32 68.8 67.3 0.424 0.496 0.143 0.268 0.353
March 94.8 48.62 4.56 125.9 122.8 0.752 0.496 0.196 0.538 0.300
April 133.7 66.21 10.55 150.4 146.1 0.867 0.496 0.225 0.622 0.271
May 174.8 83.26 17.02 173.2 167.9 0.973 0.496 0.247 0.704 0.249
June 187.7 81.63 20.06 176.6 170.9 0.976 0.496 0.251 0.704 0.245
July 193.3 80.90 23.13 187.2 181.4 1.021 0.496 0.252 0.746 0.244
August 165.5 73.04 22.53 176.9 171.5 0.968 0.496 0.237 0.709 0.259
September 112.2 52.02 16.00 139.8 135.9 0.790 0.496 0.209 0.562 0.287
October 72.7 35.69 10.90 107.3 105.0 0.625 0.496 0.170 0.439 0.326
November 37.4 21.45 5.22 63.9 62.7 0.384 0.496 0.123 0.248 0.373
December 23.8 15.00 -0.09 43.7 42.8 0.270 0.496 0.090 0.168 0.406
Year 1275.0 606.45 10.75 1472.7 1432.0 8.418 5.952 2.264 5.944 3.688

PVsyst TRIAL
Legends: GlobHor Global horizontal irradiation GlobEff Effective Global, corr. for IAM and shadings
DiffHor Horizontal diffuse irradiation EArray Effective energy at the output of the array
T_Amb T amb. E_User Energy supplied to the user
GlobInc Global incident in coll. plane E_Solar Energy from the sun
E_Grid Energy injected into grid
EFrGrid Energy from the grid

PVsyst Evaluation mode


PVSYST 7.0.11 21/09/20 Page 3/4

Grid-Connected System: Special graphs


Project : New Project
Simulation variant : New simulation variant
Main system parameters System type No 3D scene defined, no shadings
PV Field Orientation tilt 40° azimuth 0°
PV modules Model JAM60-S09-320-PR Pnom 320 Wp
PV Array Nb. of modules 20 Pnom total 6.40 kWp
Inverter Model SUN2000-5KTL-M1 Pnom 5.00 kW ac

PVsyst TRIAL
User's needs monthly values Global 5952 kWh/year

Daily Input/Output diagram

50
Values from 01/01 to 31/12

40
[kWh/day]

30
Energy

PVsyst TRIAL
Solar

20
Available

10

0
0 2 4 6 8 10
Global incident in coll. plane [kWh/m²/day]

System Output Power Distribution

PVsyst TRIAL 200

180

160
Values from 01/01 to 31/12
Bin]
/

140
[kWh

120
Energy

100
Solar

80

PVsyst TRIAL
Available

60

40

20

0
0 1 2 3 4 5 6
Available Solar Energy [kW]

PVsyst Evaluation mode


PVSYST 7.0.11 21/09/20 Page 4/4

Grid-Connected System: Loss diagram


Project : New Project
Simulation variant : New simulation variant
Main system parameters System type No 3D scene defined, no shadings
PV Field Orientation tilt 40° azimuth 0°
PV modules Model JAM60-S09-320-PR Pnom 320 Wp
PV Array Nb. of modules 20 Pnom total 6.40 kWp
Inverter Model SUN2000-5KTL-M1 Pnom 5.00 kW ac

PVsyst TRIAL
User's needs monthly values Global 5952 kWh/year

Loss diagram over the whole year

1275 kWh/m² Global horizontal irradiation


+15.5% Global incident in coll. plane

-2.77% IAM factor on global

1432 kWh/m² * 33 m² coll. Effective irradiation on collectors


efficiency at STC = 19.40% PV conversion

9.17 MWh Array nominal energy (at STC effic.)


-0.90% PV loss due to irradiance level
-5.15% PV loss due to temperature

PVsyst TRIAL
+0.75% Module quality loss

-2.10% Mismatch loss, modules and strings


-0.94% Ohmic wiring loss
8.42 MWh Array virtual energy at MPP
-2.19% Inverter Loss during operation (efficiency)
-0.06% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
grid
-0.31% Night consumption
consumption
8.21 MWh Available Energy at Inverter Output

PVsyst TRIAL
3.69 MWh 2.26 MWh

to user to user
from grid from solar
5.94 MWh

to grid
Energy injected into grid

PVsyst TRIAL
PVsyst Evaluation mode