ESTIMATE FOR CONSTRUCTION FOR SHED ON ROOF

AREA 24'X26' (7.32X7.93)

S.NO. SOR DISCRIPTION NOS L B D QTY UNIT RATE AMOUNT


ITEM NO.
Structural steel work riveted, bolted or welded in built
1 10.2 up sections, trusses and framed work, including
cutting,hoisting, fixing in position and applying a
priming coat of approved steel primer all complete.
For Vertical posts 116.104 116.104
For Horizontal post
Main direction 704.4219 704.4219
Distribution direction 361.242 361.242
Total 1181.7679 KG 68.7 81187.45

Providing corrugated G.S. sheet roofing including


vertical/ curved surface fixed with polymer coated J or
L hooks, bolts and nuts 8 mm diameter with bitumen
and G.I. limpet washers or with G.I. limpet washers
2 12.1 filled with white lead and including a coat of approved
steel primer and two coats of approved paint on
overlapping of sheets complete upto any pitch in
horizontal/ vertical or curved surfaces) excluding the
cost of purlins, rafters and trusses and including cutting
to size and shape wherever required.
12.1.1 1 7.32 7.93 58.0476 SQM 1025 59498.79
1.00mm thick with zinc coating not less than 275gm/m²
Providing and fixing chicken mesh as per ISI
specification and in the required width with 50mm long
3 13.27 Bombay nails on vertical and horizontal junctions of 2 7.32 2.3 33.672
RCC and brick wall including scaffolding and all lead
and lift etc. complete before plastering upt 10 meter
height.
2 7.93 2.3 36.478
Total 70.15 SQM 62 4349.3

Point wiring (excluding metallic switch box & sheet but

elctrical SOR 3
including switches, sockets,lamp holders/ceiling roses
etc) with 1.5 Sq. mm. PVC insulated cable FR with
4
copper multi strand conductor ISI marked in Surface
rigid P.V.C. conduit (MMS) ISI Marked of suitable size
and 1.5 Sq. mm. PVC insulated copper earth continuity
conductor of green colour inside conduit including
painting etc. as required as per specification for :-
3.4 Twin Control light points
c) Long point 2 Each 559 1118
elctrical

Supplying and fixing in position incandescent lamp of


SOR
26.7

5
approved make as per IS specification
26.7.7 500 Watt 250 Volt 6 Each 65 390
SOR elctrical SOR 26.32

Supplying, erection and testing of approved make


electric Ceiling fan of double ball bearing complete
with standard down rod, canopy, hanging shackle,
6 Aluminium blades, without regulator, A.C. 230-250 2 Each 1440 2880
volts including connections with all necessary material
complete as required confirming to IS :374/1979 with
upto date ammendments.
elctrical

Suppling and fixing of approved make step type


26.31

7 Modular electronic, Fan regulator including connection


etc. as required on existing board
26.31.3 1000 Watt 2 Each 545 1090
TOTAL CIVIL WORK AMOUNT 145035.54
TOTAL ELECTRIC WORK AMOUNT 5478.00

TOTAL AMOUNT 150513.54


1.505 LACS