You are on page 1of 1

WINDOWSCONDUCTION WALLS CONDUCTION COMPONENT  

A B C D E F G H I J K L  
Shading
Window Wall Glass Glass Device Wall OTTV (ie
OTTV

Solar Orientatio Coefficient


Wall Area Constan to Wall (1- Constr U- Shading Shadin multiply all % of
Wall Location Absorption n Factor SC1 x SC2
(m² ) t Ratio WWR) U-Value Value Coeff g Coeff shaded cells in OTTV
Factor (α) (OF) (ie columns
(WWR) (Uv) (Uf) (SC1) (SC2) the same row)
I x J)
North Wall 532.80 15 0.15 0.35 0.65 2.63 N/A N/A N/A N/A N/A 2049.35  
South Wall 532.80 15 0.15 0.35 0.65 2.63 N/A N/A N/A N/A N/A 2049.35  
HEAT

East Wall 768.00 15 0.15 0.45 0.55 2.63 N/A N/A N/A N/A N/A 2499.55  
West Wall 768.00 15 0.15 0.45 0.55 2.63 N/A N/A N/A N/A N/A 2499.55  
THROUGH

∑ Wall Area 2601.60 Equation for Heat Conduction Through Walls = 15 x α x (1 - WWR) Uv ∑ 9097.80 8.09%

North Wall 532.80 6 N/A 0.35 N/A N/A 3.60 N/A N/A N/A N/A 4027.97  
HEAT

South Wall 532.80 6 N/A 0.35 N/A N/A 3.60 N/A N/A N/A N/A 4027.97  
East Wall 768.00 6 N/A 0.45 N/A N/A 3.60 N/A N/A N/A N/A 7464.96  
West Wall 768.00 6 N/A 0.45 N/A N/A 3.60 N/A N/A N/A N/A 7464.96  
THROUGHSOLAR HEAT THROUGH

    Equation for Heat Conduction Through Windows = 6 x WWR x Uf ∑ 22985.86 20.44%

North Wall 532.80 194 N/A 0.35 N/A N/A N/A 0.90 0.49 0.77 0.38 12284.66  
South Wall 532.80 194 N/A 0.35 N/A N/A N/A 0.92 0.49 0.77 0.38 12557.66  
GAIN

East Wall 768.00 194 N/A 0.45 N/A N/A N/A 1.23 0.49 0.77 0.38 31114.83  
West Wall 768.00 194 N/A 0.45 N/A N/A N/A 0.94 0.49 0.79 0.39 24396.44  
WINDOWS

    Equation for Solar Heat Gain Through Windows = 194 x WWR x Of x SC ∑ 80353.59 71.47%

∑ WALL OTTV
112437.25 100%
∑ Wall OTTV =
∑ WALL AREA
2601.6  
∑ Wall Area =
OTTV 43.22  