Professional Documents
Culture Documents
Item No Description
Table of content
i Grand Summary
ii Specific Provisional Sum
iii Summary Bill
1 Civil Work
1.1 Main Gate & sub gate
1.2 Guard House
1.3 Weight bridge and oprator cabin
1.4 Truck Parking and Internal road
1.5 Public Toilet
1.6 Bagging and Loading House
1.7 Empty Gunny Bag Godown
1.8 Control Room
1.9 Cleaning Tower
1.10 Steel structures support for conveyors
1.10.1_ Steel structures support for conveyors on top steel silo
1.10.2_ Steel structures support for conveyors from bucket elevator tower
to truck & wagon bagging & loading house
1.10.3_Steel structures support for conveyors from cleaning tower to jetty
1.11 Sampling & Laboratory house on jetty
1.12 Silo foundation
1.13 Wagon Bagging and Loading House
1.14 Workshop cum Store
1.15 Silo Office
1.16 Car Parking
1.17 Ansar Barrack 24 persons
Table of Content-BoQ
Page-1/405
Site: Chattogram
Item No Description
Table of Content-BoQ
Page-2/405
Site: Chattogram
Item No Description
1.19 Substation
1.20 Scrap Godown
1.21 Dormitory for Officer
1.22 Dormitory for Support Staff
1.23 Fire-Fighting Pump House & water tank
1.24 Canteen & Club
1.25 Mosque
1.26 Unloader substation
1.27 Purification & desalination plant
1.28 Running Water Deep Drill Well
1.29 Link tower
1.30 Water supply system
1.31 Rain water drainage system
1.32 Waste water sewerage system
2 Electrical work
2.1 Electrical and Automation System
4 Utilities
4.1 Compressed Air Work
4.2 Fire-Fighting Work
4.3 Lightning Work
4.4 Communication System
Table of Content-BoQ
Page-3/405
Site: Chattogram
at at Chattogram
Page
1
3
4
5
9
13
25
39
42
54
65
75
85
94
101
107
115
130
136
147
158
177
182
Table of Content-BoQ
Page-4/405
Site: Chattogram
Page
197
Table of Content-BoQ
Page-5/405
Site: Chattogram
Page
216
225
236
256
275
287
305
322
330
341
350
356
358
363
366
381
393
395
397
398
399
405
Table of Content-BoQ
Page-6/405
Site: Chattogram
GRAND SUMMARY of Bill of Quantity
W-24 Construction Steel Silo for Wheat at Chattogram
Project: Modern Food Storage Facilities_ MFSP
Location: Chattogram
Owner: Directorate General of Food, Bangladesh
Consultant: Gerico France
Important: Unit Price shall include cost of material, machine, men, transportation, shipment, taxes, over heads, profit, insurance, installation,
commission, completion of each item in all respect as per BoQ, drawing, specification etc.
Amount with Currency
Item No Description of Work Currency
In Figure In Words
Grand Summary
Page-3/405
Site Chattogram
BoQ of W-24 Construction Steel Silo for Wheat at Chattogram
Project: Modern Food Storage Facilities_ MFSP
Location: Chattogram
Owner: Directorate General of Food, Bangladesh
Consultant:
1 Connection fee, deposit etc. for electric connection from Government electricity co 10,000,000.00
Connection fee
Page-4/405
Site: Chattogram
SUMMARY BOQ
Project: Modern Food Storage Facilities_ MFSP
Location: Chattogram
Owner: Directorate General of Food, Bangladesh
Consultant: Gerico France
Important: Unit Price shall include cost of material, machine, men, transportation, shipment, taxes, over heads, profit, insurance, installation, commission, completion of each
item in all respect as per BoQ, drawing, specification etc.
Unit Rates Amounts
Item No Description of Work Unit Quantity Currency
In Figure In Word In Figure In Word
1 Civil Work
1.1 Main Gate & sub gate set 1
A350-7-CW-0101
1.2 Guard House set 1
A350-7-CW-0201
1.3 Weight bridge and oprator cabin set 1
A350-7-CW-0301
1.4 Truck Parking and Internal road set 1
A350-7-CW-0001
1.5 Public Toilet set 2
A350-7-CW-5a01
1.6 Bagging and Loading House set 1
A350-7-CW-0601
1.7 Empty Gunny Bag Godown set 1
A350-7-CW-0701
1.8 Control Room set 1
A350-7-CW-0801
1.9 Cleaning Tower set 1
A350-7-CW-0901
Clearing and disposing of excavated earth from the construction site by truck
or any other means to a place within 30 km radius of the city or town area
1.5 including loading, unloading at both ends, leveling and dressing the carried earth A350-7-CW-0101, 0104 cum 1.97
etc. complete accepted by the Engineer.
Sub - Total 1
2 Concrete Work
Mass concrete
Grade 9 Mpa, 20mm down well graded crushed stone chips; produced by mixer,
2.1 casting in forms in/c supplying & laying of single layer polythene sheet weighing
6.5 kg/Sqm with allowances for lapping complete in all respect and accepted by
the Engineer.
Supplying, fitting and fixing glazed homogeneous floor tiles (Mipur ceramic /
equevalent) with cement sand (F.M. 1.2) mortar (1:4) base and raking out the
7.1
joints with white cement including cutting and laying the tiles in proper way and
finishing with care etc. all complete and accepted by the Engineer.
7.1.1_ Ceramic Tile 600mmx600mm, light colour for column A350-7-CW-0101 sqm 13.68
7.1.2_ Ceramic Tile 600mmx600mm, light colour for roof A350-7-CW-0101 sqm 96.66
Sub - Total 7
8 Structural Steel
Electrical Motor Operated sliding Stainless Steel gate (6700mm x 3000mm)
8.1 Providing and erecting Steel gate with all accessaaries. complete in all respect as A350-7-CW-0102, 0103 each 1.00
per drawing and direction of the Engineer in Charge
8.2 Single leaf stainless steel door for sub gate (1180mm x 3100mm) A350-7-CW-0102, 0103 sqm 3.54
Sub - Total 8
9 Drainage system
9.1 Pipe PVC
9.1.1_ PVC pipe D100 A350-7-CW-0102, 0103 m 11.40
9.1.2_ PVC pipe D60 A350-7-CW-0102, 0103 m 1.50
9.2 Strainer ball A350-7-CW-0102, 0103 each 2.00
Sub - Total 9
TOTAL
Sub - Total 1
6.1.3_ Plaster to below surface of roof slab A350-7-CW-0201, 0202 sqm 8.24
Mirpur ceramic 75x225 mm, dark colour for outer surface of ground
7.4 floor beam A350-7-CW-0201, 0202 sqm 9.83
Granite stone thick. 20mm
Suppling, fitting and fixing granit stone, with on 20 mm thick cement
7.5 sand (F.M. 1.2) mortar (1:4) base and ranking out the joints with
respective joint filler & binder including cutting, laying and finishing
with care etc
5mm thick glass with Thai Aluminium frame curtain window as per
8.4
design, drawing, accepted by the Engineer
8.4.1_ Single shutter curtain window CW-01 (610x1500mm)
including grill with 12mm square bar, angle, Flat bar etc. as per
drawing, design, specification etc. all complete & accepted by the A350-7-CW-0202, 0203 sqm 0.92
Engineer
Sub - Total 8
9 Finishing Work
Aluminium ceiling sheet
Supplying, fitting and fixing aluminium board ceiling of 9 mm thick
board laminated by mechanical hot press with a milk white PVC
9.1 membrane with Aluminum T- bar frame in natural anodized finish at
600*600 mm in grid suspended from ceiling by 12 SWG double ply
wire fixed to the ceiling by rowel plug, screws, hooks, nails etc.
10.10.1_ Clear 450x450 mm and depth 450 to 600 mm, average 525
mm for single 150 mm dia R.C.C.pipes and 400 mm uPVC pipe each 3.00
Sub - Total 10
a) 600 mm dia
b) Depth up to 22 m A350-7-CW-0306 m 440.00
3.1.4_ For ground floor slab and ramp A350-7-CW-0310 cum 10.88
7.2.2_ Three layer waterproofing by sika grout for roof slab A350-4-CW-0301,0302 sqm 14.08
Sub - Total 7
Sub - Total 9
4- Sub distribution board, IP54, include the terminal block each 1.00
5- Distribution board, IP54 Enclosures each 1.00
6- Socket (3-pin6A ) each 1.00
7- Socket (3-pin15A)
Providing & fixing 250 volts, single phase, 3-pin, 13/15/16amps.
Combined switch socket outlet (concealed type) manufactured
and tested in accordance with relevant IEC standards and
manufactured and tested in accordance with relevant IEC
standards and approved by BSTI mounted on required size 18 each 4.00
SWG galvanized plain sheet board of 76.2mm. (3”) depth all
electrical contacts shall be of brass/copper (Dynamic/MEP/
SK/Metro/Super Star or equivalent, local made).)
Expansion Joints
Providing expansion joints across the RCC road and pavement with
2.5 20mm gap between the adjacent panels including dowel bars, filling m 19,144.16
the joints by coarse sand & bitumen 1:1 as approved etc. accepted by
the Engineer.
TOTAL
Sub - Total 1
6.2.1_ 3 layer waterproofing by sika grout for gutter slab A350-7-CW-5a02-5a04 sqm 14.88
Sub - Total 6
7 Tiles & Stone Work
Homogenious tile 300 x 300mm
Suppling, fitting and fixing tiles with cement sand (F.M. 1.2) mortar
7.1 (1:4) base and raking out the joints with white cement including
cutting and laying the tiles in proper way and finishing with care
Sub - Total 8
9 Finishing Work
Aluminium ceiling sheet
Supplying, fitting and fixing aluminium board ceiling of 9 mm thick
board laminated by mechanical hot press with a milk white PVC
9.1 membrane with Aluminum T- bar frame in natural anodized finish at
600*600 mm in grid suspended from ceiling by 12 SWG double ply
wire fixed to the ceiling by rowel plug, screws, hooks, nails etc.
Emulsion Paint
Plastic emulsion of approved best quality and colour delivered from
authorized local agent of the manufacturere in a sealed container,
applying to wall and ceiling in two coats over lime putty of specified
9.2 brand applied on primer or sealer elapsing specified time for
drying/recoating including cleaning drying, making free from dirt,
grease, wax, removing all chalked and scaled materials, fungus,
mending good the surface defects, sand papering the surface and
necessary scaffolding, spreading by brush/ roller/ spray etc.
a) 600 mm dia
b) Depth up to 38 m A350-7-CW-0619 Rm 2,394.00
Cast in situ pile with RCC works of required slump by adding
water reducing admixture with 25 Mpa relates to mix ratio
(1:1.5:3) on standard cylinders as per standard practice of Code
ACI/BNBC/ASTM & cement conforming to BDS EN-197-1-
CEM -1,52.5 N / ASTM-C 150 Type – I, best quality coarse sand
[Sylhet sand or coarse sand of equivalent F.M.2.2], 20 mm down
well graded crushed stone chips conforming to ASTM C-33,
including breaking crushed stone chips, screening through proper
sieves, making, placing re-bar cage & binding ms pipes in
position, placing and removing tri-pod as per requirement, pouring
the concrete in bore-hole with the help of a tremie pipe,
maintaining the tremie pipe immersed in concrete by at least 1
2.2 meter throughout the period of concreting, maintaining required A350-7-CW-0619 cum 676.89
slump, etc. mixing the aggregates in diginal batching plant, casting
in bore holes, acertaining the strength by trial mix design all
complete including all cost of water, electricity, plant &
machinery, bentonite, admixture testing of materials and concrete
etc and other charges as per design, drawing etc all complete
approved and accepted by the Engineer. Concrete should prepared
by Digital batching plant, strength may be acertained by trail mix
design.
a) For 250 tonne load for 1 No. test per test 2.00
Sub - Total 2
3 Concrete Work
Mass concrete
Grade 9 Mpa, 20mm down well graded crushed stone chips;
produced by mixer, casting in forms in/c supplying & laying of
3.1 single layer polythene sheet weighing 6.5 kg/Sqm with allowances
for lapping complete in all respect and accepted by the Engineer.
3.2.3_ Concrete for ground floor beam elv +0.300m A350-7-CW-0623/0625 cum 46.46
4.1.3_ Formwork for ground floor beam elv +0.300m A350-7-CW-0623/0625 sqm 265.50
9.2 Stainless steel collapsible gate DO2 (1800x2200 mm), thk 0.5mm A350-7-CW-0606/0612/0644 sqm 3.96
Stainless steel frame door and glass 5mm thick DO1 (1000x2200
9.3 A350-7-CW-0606/0612/0644 sqm 13.20
mm)
Window 2000x800mm Louver type Galvanized steel (frame steel
9.4 A350-7-CW-0606/0612/0644 sqm 84.80
30x630x2 mm) Galvanized steel leaf 2mm
Sub - Total 9
10 Structural Steel
All steel structure, Beams, Columns, Purlins, fittings & fixtures
shall be hot rolled pre-fabricated and hot deep galvanized (EN
10.1 ISO 14713:1999 C5, Galvanized coating conforms to ASTM
A653/A653 M/EN 1461 for zinc coated steel minimum 600
gm/m2)
A350-7-CW-
10.1.1_Galvanized Steel column kg 33,935.41
0614/0628/0635/0636
10.1.2_Galvanized Steel beams A350-7-CW-(0632-0638) kg 36,607.58
10.1.3_ Galvanized steel purlin for roof and wall C200x65x20x2
A350-7-CW-(0637-0638) kg 3,768.97
mm
10.1.4_ Galvanized steel purlin for roof Z250x65x20x2 mm A350-7-CW-(0633-0638) kg 27,067.30
10.4 Galvaized steel Bracing D12mm with 2 nuts for purlin A350-7-CW-(0632-0638) m 580.80
10.5 Galvaized steel Bracing C chanel 200mm for column A350-7-CW-(0632-0638) m 24.49
10.10 Roof Insulation (fiber glass with galvanized mesh) A350-7-CW-(0610-0613) sqm 1,564.09
10.11 Pre_ painted galvanized Steel wall, 0.61mm thick A350-7-CW-(0610-0613) sqm 369.84
10.12 Pre_ painted galvanized Steel Flashing, 0.61mm thick A350-7-CW-(0610-0613) m 291.30
10.15 Square galvanized steel tube 100x50x2 and 50x50x2 A350-7-CW-(0610-0613) kg 931.51
2- Sub distribution board, IP54, include the terminal block each 3.00
3- Distribution board, IP54 Enclosures each 1.00
4- High pressure lamp 250W (SODIUM VAPOUR
LAMP(230V,50Hz) (Osram/Philips/GE/Harmonics or equivalent
each 26.00
brand accepted/approved by the Engineer)250 watt high pressure
sodium vapour lamp.)
11.2 Protection (MCB & MCCB)
2- MCB 2px6, 6KA each 7.00
3- MCB 2px10, 6KA each 8.00
4- MCB 2px16,6KA each 1.00
5- MCB 2px20, 6KA each 1.00
6- MCB 3px6, 6KA each 1.00
7- MCB 4px20, 6KA each 8.00
8- MCB 4px32, 6KA each 2.00
9- MCB 4px80, 6KA each 1.00
Electrical wire and cable (include conduit pipes, junction box with
11.3
terminal block and concealed)
1- (NYY) / XLPE insulated & PVC sheathed, 0.6/1KV, Cu, Single
m 1,910.00
- core 1c x0.75 mm²
2- (NYY) / XLPE insulated & PVC sheathed, 0.6/1KV, Cu, Single
m 1,730.00
- core 1c x 1.5 mm²
3- (NYY) / XLPE insulated & PVC sheathed, 0.6/1KV, Cu, Single
m 320.00
- core 1c x 2.5 mm²
4- (NYY) / XLPE insulated & PVC sheathed, 0.6/1KV, Cu, Multi
m 30.00
- core 5c x 6 mm²
5- (NYY) / XLPE insulated & PVC sheathed, 0.6/1KV, Cu, Multi
m 15.00
- core 5c x 10 mm²
Sub - Total 11
TOTAL
1.5 Sand filling to elv +1.00 with compaction k=0.95 A350-7-CW-0713, 0710 cum 465.00
Sub - Total 1
a) 450 mm dia
b) Depth up to 38 m A350-7-CW-0712 m 608.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code ACI/BNBC/ASTM
& cement conforming to BDS EN-197-1- CEM -1,52.5 N / ASTM-C
150 Type – I, best quality coarse sand [Sylhet sand or coarse sand of
equivalent F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking crushed stone chips,
screening through proper sieves, making, placing re-bar cage & binding
ms pipes in position, placing and removing tri-pod as per requirement,
pouring the concrete in bore-hole with the help of a tremie pipe,
maintaining the tremie pipe immersed in concrete by at least 1 meter
2.2 throughout the period of concreting, maintaining required slump, etc. A350-7-CW-0712 cum 95.93
mixing the aggregates in diginal batching plant, casting in bore holes,
acertaining the strength by trial mix design all complete including all
cost of water, electricity, plant & machinery, bentonite, admixture
testing of materials and concrete etc and other charges as per design,
drawing etc all complete approved and accepted by the Engineer.
Concrete should prepared by Digital batching plant, strength may be
acertained by trail mix design.
3.2.2_ Concrete for pedestal column and column A350-7-CW- 0713 cum 1.12
3.2.4_ Concrete for beam elv +4.300m A350-7-CW- 0717 cum 9.20
3.2.5_ Concrete for beam elv +6.050m A350-7-CW- 0717 cum 9.20
3.2.7_ Concrete for ramp slope A350-7-CW- 0706, 0715 cum 4.23
4.1.2_ Formwork for pedestal column and column A350-7-CW- 0713, 0714, 0716 sqm 9.44
5.1.2_ Rebar for for Padestal column and column A350-7-CW- 0713 kg 4,185.67
5.1.3_ Rebar for beam elv +1.000m A350-7-CW- 0713, 0714 kg 3,110.91
5.1.4_ Rebar for beam elv +4.300m A350-7-CW- 0716, 0717 kg 2,269.53
5.1.5_ Rebar for beam elv +6.050m A350-7-CW- 0716, 0717 kg 2,269.53
7.1.3_ Plaster to beam at +1.000m, +4.300m, +6.050m A350-7-CW- 0714, 0716 sqm 244.40
7.2.1_ For ground floor slab at +1.000 A350-7-CW- 0715 sqm 3.06
10.8 Roof Insulation (fiber glass with galvanized mesh) A350-7-CW-0707 sqm 513.70
10.9 Pre_painted galvanized Steel wall, 0.61 thick A350-7-CW-0707 sqm 124.00
10.11 Galvanized handrail D48.1mm, 3.5mm thk for staircase and ramp A350-7-CW-0706 kg 85.78
Sub - Total 11
TOTAL
Sub - Total 1
6.2 Waterproofing
6.2.1_ Three layers waterproofing by sika grout for gutter slab A350-7-CW-0803 sqm 18.54
Sub - Total 6
7 Tiles & Stone Work
Ceramic tile 600x600 light colour for floor
Suppling, fitting and fixing tiles with cement sand (F.M. 1.2) mortar
7.1 (1:4) base and raking out the joints with white cement including
cutting and laying the tiles in proper way and finishing with care
7.3 Ceramic 75x225, dark colour for outer surface of ground floor beam A350-7-CW-0802-0804 sqm 24.84
Roof tile
7.4 Supplying, fitting and fixing country made (Mirpur A350-7-CW-0802-0804 sqm 97.28
Ceramic/equivalent) roof tile, with adhesive motar
Sub - Total 7
8 Door & Window
Wooden (matured & seasoned Mehaghani) entry door and frame
Supplying and making solid wooden door for all floors with matured
natural seasoned wood of required size including painting two coats of
8.1 coal tar to the surface in contact with all, fitting and fixing in position.
Frame (size 250x62mm) & shutter as per design, drawing, accepted by
the Engineer
8.3.2_ Single shutter curtain window CW-01 (610x1500mm) A350-7-CW-0805 sqm 3.66
Sub - Total 8
9 Finishing Work
Aluminium ceiling sheet
Supplying, fitting and fixing aluminium ceiling of 9 mm thick board
laminated by mechanical hot press with a milk white PVC membrane
9.1 with Aluminum T- bar frame in natural anodized finish at 600*600
mm in grid suspended from ceiling by 12 SWG double ply wire fixed
to the ceiling by rowel plug, screws, hooks, nails etc.
Sub - Total 1
a) 600 mm dia
b) Depth up to 38 m A350-7-CW-0931 m 3,230.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code
ACI/BNBC/ASTM & cement conforming to BDS EN-197-1- CEM
-1,52.5 N / ASTM-C 150 Type – I, best quality coarse sand [Sylhet
sand or coarse sand of equivalent F.M.2.2], 20 mm down well graded
crushed stone chips conforming to ASTM C-33, including breaking
crushed stone chips, screening through proper sieves, making, placing
re-bar cage & binding ms pipes in position, placing and removing tri-
pod as per requirement, pouring the concrete in bore-hole with the
help of a tremie pipe, maintaining the tremie pipe immersed in
concrete by at least 1 meter throughout the period of concreting,
2.2 A350-7-CW-0931 cum 912.80
maintaining required slump, etc. mixing the aggregates in diginal
batching plant, casting in bore holes, acertaining the strength by trial
mix design all complete including all cost of water, electricity, plant
& machinery, bentonite, admixture testing of materials and concrete
etc and other charges as per design, drawing etc all complete
approved and accepted by the Engineer. Concrete should prepared by
Digital batching plant, strength may be acertained by trail mix design.
3.2.3_ Concrete for pedestal column A350-7-CW-0932, 0933, 0938 cum 92.26
3.2.4_ Concrete for beam at elv +0.300 A350-7-CW-0934, 0938 cum 18.20
3.2.5_ Concrete for beam at elv +5.000 A350-7-CW-0934, 0938 cum 18.20
3.2.6_ Concrete for slab at elv +0.300 A350-7-CW-0934, 0941 cum 54.22
3.2.7_ Concrete for slab at elv +5.000 A350-7-CW-0934, 0941 cum 49.40
4.1.3_ Formwork for pedestal column A350-7-CW-0932, 0933, 0938 sqm 386.28
4.1.4_ Formwork for beam at elv +0.300 A350-7-CW-0934, 0938 sqm 113.26
4.1.5_ Formwork for beam at elv +5.000 A350-7-CW-0934, 0938 sqm 113.26
4.1.6_ Formwork for slab at elv +5.000 A350-7-CW-0934, 0941 sqm 197.60
7.2 Non- shrink grout for column A350-7-CW-0934, 0941 cum 0.33
Sub - Total 7
8 Door & Window
Electrical rolling door DO3 (3000x3000 mm)
8.1 Supplying and fixing electric rolling door, include motor, key switch, A350-7-CW-0906, 0912, 0918, each 2.00
break release and solid shutter. 0920
8.2 Stainless steel frame door, 1.5mm thick and glass 5mm thick
8.2.1_Stainless steel frame door DO1 single leaf (1000x2200 mm) A350-7-CW-0912, 0921, sqm 24.20
8.2.2_Stainless steel frame door DO2 double leaf (1800x2200 mm) A350-7-CW-0912, 0921 sqm 3.96
Window WD1 (1500x800mm) Louver type Galvanized steel (steel
8.3 A350-7-CW- 0918, 0921 sqm 158.40
frame 30x630x2 mm) Galvanized steel leaf 2mm thick
Sub - Total 8
9 Structural Steel
All steel structure, Beams, Columns, Angles, C- Channels, fittings &
fixtures shall be hot rolled pre-fabricated and hot deep galvanized
9.1 (EN ISO 14713:1999 C5, Galvanized coating conforms to ASTM
A653/A653 M/EN 1461 for zinc coated steel minimum 600 gm/m2)
9.2 Galvaized steel Bracing D12mm with 2 nuts for purlin A350-7-CW-0922-0925 m 574.20
9.3 Galvaized steel Bracing C channel 200mm for column A350-7-CW-0922-0925 kg 12,265.44
9.4.3_ Galvanized grating for stairtread (PL50x5mm and PL50x3mm) A350-7-CW-0922-0930 sqm 58.66
9.8 Roof Insulation (fiber glass with galvanized mesh) A350-7-CW-0922-0925 sqm 216.37
9.9 Pre_ painted galvanized Steel wall, 0.61 thick A350-7-CW-0911-0925 sqm 2,258.25
9.10 Pre_ painted galvanized Steel Flashing, 0.61 thick A350-7-CW-0911-0925 m 268.81
Sub - Total 9
TOTAL
Sub - Total 1
a) 500 mm dia
b) Depth up to 38 m A350-7-CW-10.116-10.118 m 1,368.00
Reinforcement Work
Supplying, fabrication and fixing to details as per design: Grade
400 (RB 400 /RB 400W: complying BDS ISO 6935-2:2006)
ribbed or deformed bar produced and marked according to
Bangladesh standard, with minimum yield strength, fy (ReH)=
400 MPa but fy not exceeding 450 MPa and whatever is the
yield strength within allowable limit as per BNBC/ ACI 318,
the ratio of ultimate tensile strength fu to yield strength fy,
shall be at least 1.25 and minimum elongation after fracture
and minimum total elongation at maximum force is 16% and
2.3 A350-7-CW-10.116-10.118 kg 39,942.17
8% respectively including welding of lapping and spirals as
per design, drawing, straightening and cleaning rust, if any,
bending and binding in position with supply of G.I. wires,
splices or laps what so ever etc. all complete accepted by the
Engineer (Measurement shall be recorded only on Standard
Mass per Unit length of Bars, while, dia of bars exceeds its
standard)
6.3.4_Galvanized grating F40x3mm for rest platforms A350-7-CW-10.120, 10.121, 10.128 sqm 30.00
6.3.6_ Vertical galvanized steel PL 40x5mm thk for protection A350-7-CW-10.120, 10.121, 10.128 kg 743.36
Sub - Total 6
TOTAL
a) 600 mm dia
b) Depth up to 38 m A350-7-CW-10.210 m 608.00
Cast in situ pile with RCC works of required slump by adding
water reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3)
on standard cylinders as per standard practice of Code
ACI/BNBC/ASTM & cement conforming to BDS EN-197-1- CEM
-1,52.5 N / ASTM-C 150 Type – I, best quality coarse sand [Sylhet
sand or coarse sand of equivalent F.M.2.2], 20 mm down well
graded crushed stone chips conforming to ASTM C-33, including
breaking crushed stone chips, screening through proper sieves,
making, placing re-bar cage & binding ms pipes in position,
placing and removing tri-pod as per requirement, pouring the
concrete in bore-hole with the help of a tremie pipe, maintaining
the tremie pipe immersed in concrete by at least 1 meter throughout
2.2 the period of concreting, maintaining required slump, etc. mixing A350-7-CW-10.210 cum 171.91
the aggregates in diginal batching plant, casting in bore holes,
acertaining the strength by trial mix design all complete including
all cost of water, electricity, plant & machinery, bentonite,
admixture testing of materials and concrete etc and other charges as
per design, drawing etc all complete approved and accepted by the
Engineer. Concrete should prepared by Digital batching plant,
strength may be acertained by trail mix design.
Sub - Total 1
a) 600 mm dia
b) Depth up to 38 m A350-7-CW-10.313 m 2,280.00
A350-7-CW-
3.1.1_ For footing cum 33.39
10.314/10.315/10.316
Reinforced cement concrete works with minimum cement concrete
relates to mix ratio 1:1.5:3 having minimum f’ cr = 30 Mpa, and
satisfying a specified compressive strength f’c= 25 Mpa at 28 days on
standard cylinders as per standard practice of code
ACI/BNBC/ASTM & Cement conforming to BDS EN-197-1 CEM1,
52.5N (52.5 Mpa) / ASTM-C 150 Type – I, best quality Sylhet sand
or coarse sand of equivalent F.M 2.2 and 20 mm down well graded
crushed stone chips conforming to ASTM C-33; preparing the
concrete mix in the Digital Batching plant, ascertaing the strength by
3.2 trail mix design, casting in forms, compacting by vibrator machine
and curing at least for 28 days, removing centering-shuttering after
specified time approved; including all cost of water, electricity,
admixture, additional testing charges of materials and cylinders
required by Engineer, other charges etc. all complete approved and
accepted by the Engineer.
A350-7-CW-
3.2.1_ Concrete for footing cum 276.42
10.314/10.315/10.316
3.2.2_ Concrete for pedestal column and column A350-7-CW-1414/1417 cum 12.53
Sub - Total 3
4 Form Work
Steel formwork include making, placing shutter in position and
maintaining true to plumb, making shutter in position and
4.1 maintaining true to plumb, making shutter water-tight properly,
placing reinforcement in position. all complete approved and
accepted by the Engineer.
A350-7-CW-
5.1.1_ Rebar for footing, Padestal column and column kg 24,966.64
10.314/10.315/10.316
Sub - Total 5
6 Plastering & Waterproofing Work
6.1 Non- shrink grout for column A350-7-CW- 10.317-1025 cum 3.04
Sub - Total 6
7 Structural Steel
All steel structure, Beams, Columns, Angles, C- Channels, fittings &
fixtures shall be hot rolled pre-fabricated and hot deep galvanized
7.1 (EN ISO 14713:1999 C5, Galvanized coating conforms to ASTM
A753/A753 M/EN 1471 for zinc coated steel minimum 600 gm/m2)
A350-7-CW-
2.2.1_ Concrete for footing cum 3.07
1108/1109/1101
A350-7-CW-
2.2.2_ Concrete for pedestal column cum 2.82
1108/1109/1101
A350-7-CW-
2.2.3_ Concrete for ground floor beam cum 7.09
1108/1109/1101
A350-7-CW-
2.2.4_ Concrete for beam at level +4.450 cum 7.83
1108/1109/1101
A350-7-CW-
2.2.5_ Concrete for roof beam cum 3.18
1108/1109/1111
6.1.3_Plaster to ceiling and lower surface of roof slab A350-7-CW-1101, 1103 sqm 93.03
Emulsion Paint
Plastic emulsion of approved best quality and colour delivered from
authorized local agent of the manufacturere in a sealed container,
applying to wall and ceiling in two coats over lime putty of
specified brand applied on primer or sealer elapsing specified time
9.2
for drying/recoating including cleaning drying, making free from
dirt, grease, wax, removing all chalked and scaled materials,
fungus, mending good the surface defects, sand papering the
surface and necessary scaffolding, spreading by brush/ roller/ spray
etc.
10.5 Tee
10.6 Reducer
10.7 Elbow
Sub - Total 10
11 Sanitary Accessories (Cotto or equivalent)
A350-7-CW-1105,1104, A350-7-DW-2-1102
Toilet bowl
Supplying, fitting, and fixing European type of toilet bowl. in/c
11.1 plastic seat cover, cistern system, preparing the base with cement each 1.00
concrete and with wire mesh or roads if necessary, including
making holes and fitting, fixing, finishing etc.
Supply, fitting and fixing best quality CP pillar cock ect. (Cotto or
11.10
equivalent). Complete approved and accepted by the Engineer
5- Sub distribution board, IP54, include the terminal block each 2.00
6- Distribution board, IP54 Enclosures each 1.00
7- Socket (3-pin6A ) each 5.00
8- Socket (3-pin15A)
Providing & fixing 250 volts, single phase, 3-pin, 13/15/16amps.
Combined switch socket outlet (concealed type) manufactured and
tested in accordance with relevant IEC standards and manufactured
and tested in accordance with relevant IEC standards and approved
by BSTI mounted on required size 18 SWG galvanized plain sheet each 6.00
board of 76.2mm. (3”) depth all electrical contacts shall be of
brass/copper (Dynamic/MEP/ SK/Metro/Super Star or equivalent,
local made).)
Sub - Total 1
a) 600 mm dia
b) Depth up to 42 m A350-7-CW-1203/1204 m 42,336.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code ACI/BNBC/ASTM
& cement conforming to BDS EN-197-1- CEM -1,52.5 N / ASTM-C
150 Type – I, best quality coarse sand [Sylhet sand or coarse sand of
equivalent F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking crushed stone chips,
screening through proper sieves, making, placing re-bar cage &
binding ms pipes in position, placing and removing tri-pod as per
requirement, pouring the concrete in bore-hole with the help of a
tremie pipe, maintaining the tremie pipe immersed in concrete by at
2.2 least 1 meter throughout the period of concreting, maintaining required A350-7-CW-1203/1204 cum 11,964.15
slump, etc. mixing the aggregates in diginal batching plant, casting in
bore holes, acertaining the strength by trial mix design all complete
including all cost of water, electricity, plant & machinery, bentonite,
admixture, testing of materials and concrete etc and other charges as
per design, drawing etc all complete approved and accepted by the
Engineer. Concrete should prepared by Digital batching plant, strength
may be acertained by trail mix design.
5.1.4_ Rebar for slab (upper and lower slab) A350-7-CW-1211/1212/1213 kg 485,742.89
Sub - Total 5
6 Structural Steel
Hot deep galvanized (EN ISO 14713:1999 C5, Galvanized coating
6.1 conforms to ASTM A653/A653 M/EN 1461 for zinc coated steel
minimum 600 gm/m2)
6.1.1_ Galvanized Steel L-50x50x5mm A350-7-CW-1210/1211 kg 18,804.68
1.5 Sand filling with compaction k=0.95 A350-7-CW-1313, 1320-1325 cum 426.60
Sub - Total 1
a) 600 mm dia
b) Depth up to 38 m A350-7-CW-1318, 1321 m 1,900.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code ACI/BNBC/ASTM
& cement conforming to BDS EN-197-1- CEM -1,52.5 N / ASTM-C
150 Type – I, best quality coarse sand [Sylhet sand or coarse sand of
equivalent F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking crushed stone chips,
screening through proper sieves, making, placing re-bar cage & binding
ms pipes in position, placing and removing tri-pod as per requirement,
pouring the concrete in bore-hole with the help of a tremie pipe,
maintaining the tremie pipe immersed in concrete by at least 1 meter
2.2 throughout the period of concreting, maintaining required slump, etc. A350-7-CW-1318, 1321 cum 537.21
mixing the aggregates in diginal batching plant, casting in bore holes,
acertaining the strength by trial mix design all complete including all
cost of water, electricity, plant & machinery, bentonite, admixture,
testing of materials and concrete etc and other charges as per design,
drawing etc all complete approved and accepted by the Engineer.
Concrete should prepared by Digital batching plant, strength may be
acertained by trail mix design.
3.2.3_ Concrete for beam elv +0.000 m A350-7-CW- 1322- 1325 cum 44.50
3.2.7_ Concrete for slab elv +1.350m and +1.400m A350-7-CW-1323 cum 65.35
3.2.7_ Concrete for slab elv +5.200m and +6.000m A350-7-CW-1331 cum 34.97
4.1.3_ Formwork for beam elv +0.000m A350-7-CW- 1322-1325 sqm 254.28
6.1.1_ Exterior wall from +1.400 to +5.200 A350-7-CW- 1315-1317 cum 116.34
Normal brick work 250mm to 375mm thick
Brick work of width one brick or one and a half brick length with first
class bricks in cement sand (F.M. 1.2) mortar (1:6), in superstructure
including raking out joints, filling the interstices with mortar, cleaning
6.2 and soaking bricks at least 24 hours before use and washing of sand,
necessary scaffolding, curing at least 7 days etc. all complete
(measurement to given as 250mm width for one brick length and
375mm for one brick and a half brick length)
7.3 Non- shrink grout for column A350-7-CW-1306 ÷ 1314 cum 1.20
Sub - Total 7
8 Tiles & Stone Work
8.1 Ceramic 75x225 mm, dark colour for lintel A350-7-CW-1306 ÷ 1314 sqm 12.27
Sub - Total 8
9.2.2_Stainless steel frame door DO1 single leaf (1000x2200 mm) A350-7-CW-1306, 1311-1314 sqm 2.20
Window WD-01 (2000x800mm) Louver type Galvanized steel (steel
9.3 frame 30x630x2 mm) Galvanized steel leaf 2mm thk A350-7-CW-1306, 1311-1314 sqm 57.60
Sub - Total 9
10 Structural Steel
All steel structure, Beams, Columns, Purlins, fittings & fixtures shall be
hot rolled pre-fabricated and hot deep galvanized (EN ISO 14713:1999
10.1 C5, Galvanized coating conforms to ASTM A653/A653 M/EN 1461
for zinc coated steel minimum 600 gm/m2)
10.4 Galvaized steel Bracing D12mm with 2 nuts for purlin A350-7-CW-1343-1346 m 411.40
10.5 Galvaized steel Bracing C channel 200mm for column A350-7-CW-1343/1344 kg 187.20
10.6 Galvanized Steel stair
10.6.2_Galvanized Grating for stairtread (PL50x5mm and PL50x3mm) A350-7-CW-1337/1338 sqm 34.57
10.6.3_Galvanized Grating for walkways and platforms (F40x3mm) A350-7-CW-1337/1338 sqm 15.13
10.10 Roof Insulation (fiber glass with galvanized mesh) A350-7-CW-1310 sqm 712.15
10.11 Pre_ painted galvanized Steel wall, 0.61 thick A350-7-CW-1311-1315 sqm 1,015.45
10.12 Pre_ painted galvanized Steel Flashing, 0.61 thick A350-7-CW-1311-1315 m 229.80
10.15 Galvanized square steel tube 100x50x2 and 50x50x2 A350-7-CW-1311-1315 kg 27.00
1.5 Sand filling to elv +1.00 with compaction k=0.95 A350-7-CW-1409/1413/1414 cum 325.00
Clearing and disposing of excavated earth from the
construction site by truck or any other means to a place within 30
1.6 km radius of the city or town area including loading, unloading at A350-7-CW-1409/1413/1414 cum 48.58
both ends, leveling and dressing the carried earth etc. complete
accepted by the Engineer.
Sub - Total 1
a) 450 mm dia
b) Depth up to 38 m A350-7-CW-1412 m 684.00
Reinforcement Work
Supplying, fabrication and fixing to details as per design: Grade
400 (RB 400 /RB 400W: complying BDS ISO 6935-2:2006)
ribbed or deformed bar produced and marked according to
Bangladesh standard, with minimum yield strength, fy (ReH)=
400 MPa but fy not exceeding 450 MPa and whatever is the yield
strength within allowable limit as per BNBC/ ACI 318, the ratio
of ultimate tensile strength fu to yield strength fy, shall be at least
1.25 and minimum elongation after fracture and minimum total
2.3 elongation at maximum force is 16% and 8% respectively A350-7-CW-1412 kg 8,403.67
including welding of lapping and spirals as per design,
drawing, straightening and cleaning rust, if any, bending and
binding in position with supply of G.I. wires, splices or laps what
so ever etc. all complete accepted by the Engineer (Measurement
shall be recorded only on Standard Mass per Unit length of Bars,
while, dia of bars exceeds its standard)
3.2.2_ Concrete for pedestal column and column A350-7-CW-1414/1417 cum 0.86
3.2.3_ Concrete for beam elv +1.000m A350-7-CW-1415 cum 9.42
4.1.2_ Formwork for pedestal column and column A350-7-CW-1414/1417 sqm 11.52
6.1.1_ For wall from +1.000 to +6.450 m and to roof A350-7-CW-1406-1410 cum 160.78
Normal brick work 250mm to 375mm thick
Brick work of width one brick or one and a half brick length with
first class bricks in cement sand (F.M. 1.2) mortar (1:6), in
superstructure including raking out joints, filling the interstices
with mortar, cleaning and soaking bricks at least 24 hours before
6.2 use and washing of sand, necessary scaffolding, curing at least 7
days etc. all complete (measurement to given as 250mm width for
one brick length and 375mm for one brick and a half brick
length). (Cement: CEM-I)
11.8 Roof Insulation (fiber glass with galvanized mesh) A350-7-CW-1407/ 1408/ 1409 sqm 486.45
11.9 Pre_painted galvanized Steel wall, 0.61 thick A350-7-CW-1407/ 1408/ 1409 sqm 588.90
11.10 Pre_painted galvanized Steel Flashing, 0.61 thick A350-7-CW-1407/ 1408/ 1410 m 59.20
11.11 Stainless steel gutter thk 1.2mm A350-7-CW-1407/ 1408/ 1409 m 60.00
11.13 Square galvanized steel tube 50x50x2 A350-7-CW-1407/ 1408/ 1409 kg 188.40
11.14 Downspout uPVC D100 mm, 2.8mm thk A350-7-CW-1407/ 1408/ 1409 m 86.40
Sub - Total 11
12 Electrical Work
Ref: A350-7-LA-1401
Electrical equipment
12.1
Providing and fixing electric equipment to position
a) 600 mm dia
b) Depth up to 22 m A350-7-CW-1516 m 1,210.00
Cast in situ pile with RCC works of required slump by adding
water reducing admixture with 25 Mpa relates to mix ratio
(1:1.5:3) on standard cylinders as per standard practice of Code
ACI/BNBC/ASTM & cement conforming to BDS EN-197-1-
CEM -1,52.5 N / ASTM-C 150 Type – I, best quality coarse sand
[Sylhet sand or coarse sand of equivalent F.M.2.2], 20 mm down
well graded crushed stone chips conforming to ASTM C-33,
including breaking crushed stone chips, screening through proper
sieves, making, placing re-bar cage & binding ms pipes in
position, placing and removing tri-pod as per requirement, pouring
the concrete in bore-hole with the help of a tremie pipe,
2.2 maintaining the tremie pipe immersed in concrete by at least 1 A350-7-CW-1516 cum 341.95
meter throughout the period of concreting, maintaining required
slump, etc. mixing the aggregates in batching plant, casting inbore
holes, all complete including water, electricity, testing of materials
and concrete etc and other charges as per design, drawing etc all
complete approved and accepted by the Engineer. Concrete should
prepared by Digital batching plant, strength may be acertained by
trail mix design.
6.1.1_ Ground floor wall include balcony wall A350-7-CW-1503-1505 cum 44.96
6.1.2_ 1st floor wall include balcony wall A350-7-CW-1503-1505 cum 43.10
7.1.3_ Plaster to ceiling and lower surface of roof slab A350-7-CW-1520, 1522, 1523 sqm 285.67
Emulsion Paint
Plastic emulsion of approved best quality and colour delivered
from authorized local agent of the manufacturere in a sealed
container, applying to wall and ceiling in two coats over lime putty
of specified brand applied on primer or sealer elapsing specified
10.2
time for drying/recoating including cleaning drying, making free
from dirt, grease, wax, removing all chalked and scaled materials,
fungus, mending good the surface defects, sand papering the
surface and necessary scaffolding, spreading by brush/ roller/
spray etc.
11.2 Stainless steel handrail with wooden top rail for staircase A350-7-CW-1510 m 12.22
7- Sub distribution board, IP42, include the terminal block each 2.00
8- Distribution board, IP42 Enclosures each 1.00
9- Socket (3-pin 6A) each 29.00
10- Socket (3-pin 15A)
Providing & fixing 250 volts, single phase, 3-pin, 13/15/16amps.
Combined switch socket outlet (concealed type) manufactured and
tested in accordance with relevant IEC standards and
manufactured and tested in accordance with relevant IEC
standards and approved by BSTI mounted on required size 18 each 10.00
SWG galvanized plain sheet board of 76.2mm. (3”) depth all
electrical contacts shall be of brass/copper (Dynamic/MEP/
SK/Metro/Super Star or equivalent, local made).)
6.1.3_ Plaster to ceiling and below surface of roof slab A350-7-CW-1719 sqm 400.38
6.1.4_ Plaster to column A350-7-CW-1714, 1715 sqm 318.57
Mirpur ceramic 75x225 mm, dark colour for outer surface of ground
7.4 floor beam A350-7-CW-1717-1718 sqm 64.23
Granite stone 20mm thick
Suppling, fitting and fixing granit stone, with on 20 mm thick cement
7.5 sand (F.M. 1.2) mortar (1:4) base and ranking out the joints with
respective joint filler & binder including cutting, laying and finishing
with care etc
11.5 Tee
11.6 Reducer
11.6.1_27-20 Reducer each 5.00
11.7 Elbow
Sub - Total 1
a) 600 mm dia
b) Depth up to 22 m A350 - 7 -CW- 1814 Rm 1,276.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code ACI/BNBC/ASTM
& cement conforming to BDS EN-197-1- CEM -1,52.5 N / ASTM-C
150 Type – I, best quality coarse sand [Sylhet sand or coarse sand of
equivalent F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking crushed stone chips,
screening through proper sieves, making, placing re-bar cage &
binding ms pipes in position, placing and removing tri-pod as per
requirement, pouring the concrete in bore-hole with the help of a
2.2 tremie pipe, maintaining the tremie pipe immersed in concrete by at A350 - 7 -CW- 1814 cum 360.60
least 1 meter throughout the period of concreting, maintaining required
slump, etc. mixing the aggregates in batching plant, casting inbore
holes, all complete including water, electricity, testing of materials and
concrete etc and other charges as per design, drawing etc all complete
approved and accepted by the Engineer. Concrete should prepared by
Digital batching plant, strength may be acertained by trail mix design.
3.2.2_ Concrete for pedestal column A350 - 7 -CW-1816, 1817 cum 1.50
3.2.3_ Concrete for ground floor beam A350 - 7 -CW-1815,1816,1817 cum 0.18
3.2.4_ Concrete for 1st floor beam A350 - 7 -CW-1820,1819 cum 16.96
3.2.5_ Concrete for 2nd floor beam A350 - 7 -CW-1820,1821 cum 16.96
3.2.6_ Concrete for beam elv + 10.700m and +10.980m A350 - 7 -CW-1822,1823 cum 11.62
3.2.8_ Concrete for ground floor slab A350 - 7 -CW-1801,1817 cum 18.73
3.2.9_ Concrete for 1st floor slab A350 - 7 -CW-1820 cum 16.76
3.2.10_ Concrete for 2nd floor slab A350 - 7 -CW-1820 cum 16.76
4.1.2_ Formwork for pedestal column A350 - 7 -CW-1816, 1817 sqm 12.00
4.1.3_ Formwork for ground floor beam A350 - 7 -CW-1815,1816,1817 sqm 8.20
4.1.4_ Formwork for 1st floor beam A350 - 7 -CW-1820,1819 sqm 152.40
4.1.5_ Formwork for 2nd floor beam A350 - 7 -CW-1820,1821 sqm 152.40
4.1.6_ Formwork for beam elv + 10.700m and +10.980m A350 - 7 -CW-1822,1823 sqm 121.96
4.1.8_ Formwork for 1st floor slab A350 - 7 -CW-1820 sqm 147.00
4.1.9_ Formwork for 2nd floor slab A350 - 7 -CW-1820 sqm 147.00
6.1.1_ Ground floor wall include balcony wall A350 - 7 -CW-1803,1804 cum 28.83
6.1.2_ 1st floor wall include balcony wall A350 - 7 -CW-1803,1804 cum 38.25
6.1.3_ 2nd floor wall include balcony wall A350 - 7 -CW-1803,1804 cum 38.25
Exposed brick work for interior wall
Exposed 125mm thick pointing extra ordinary ornamental brick work
with automatic machine made 10 holes first class bricks (Mirpur
Ceramics or equivalent) in cement sand (F.M.1.2) mortar (1:4) and
making bond with connected walls including necessary scaffolding,
6.2 raking out joints, cleaning and soaking the bricks for at least 24 hours
before use and washing of sand curing at least for 7 days in all floors
including cost of water, electricity and other charges ect. all complete
and acceplete and accepted by the Engineer. (Cement: CEM-I) in
ground floor.
6.2.1_ Ground floor A350 - 7 -CW-1803,1804 sqm 119.39
7.1.3_ Plaster to ceiling and below surface of roof slab A350 - 7 -CW-1820, 1820 sqm 442.38
7.2.1_ Three layers waterproofing by sika for gutter slab A350 - 7 -CW-1803,1804 sqm 25.92
Sub - Total 7
8 Tiles & Stone Work
Homogenious mirror polish tile 600x600 mm for floor
Suppling, fitting and fixing tiles with cement sand (F.M. 1.2) mortar
8.1 (1:4) base and raking out the joints with white cement including
cutting and laying the tiles in proper way and finishing with care
10.1.1_ Aluminium ceiling of ground floor A350 - 7 -CW-1820, 1820 sqm 147.00
10.1.2_ Aluminium ceiling of 1st floor A350 - 7 -CW-1820, 1820 sqm 147.00
10.1.3_ Aluminium ceiling of 2nd floor A350 - 7 -CW-1820, 1820 sqm 147.00
Emulsion Paint
Plastic emulsion of approved best quality and colour delivered from
authorized local agent of the manufacturere in a sealed container,
applying to wall and ceiling in two coats over lime putty of specified
brand applied on primer or sealer elapsing specified time for
10.2 drying/recoating including cleaning drying, making free from dirt,
grease, wax, removing all chalked and scaled materials, fungus,
mending good the surface defects, sand papering the surface and
necessary scaffolding, spreading by brush/ roller/ spray etc.
11.2 Stainless steel handrail with wooden top rail for staircase A350 - 7 -CW-1807 m 12.22
11.3 Stainless steel handrail for balcony wall A350 - 7 -CW-1802 m 52.20
Sub - Total 11
12.5 Tee
12.6 Reducer
13.7 Flush faucet for toilet bowl (Cotto or equivalent) each 11.00
13.8 Wash basin faucet (Cotto or equivalent) each 13.00
Paper holder
Supplying, fitting, and fixing standard toilet paper holder of
13.9 150*150*126 mm size including making holes in walls and mending each 11.00
good the damages with cement mortar (1:4) etc.
Porcelain soap tray
Supplying, fitting, and fixing standard size soap tray including making
13.10 holes in walls and mending good the damages with cement mortar each 11.00
(1:4) etc.
Supplying, fitting and fixing best quality faucets etc. (Cotto or
13.11 equivalent). Complete approved and accepted by the Engineer
13.11.1_12mm CP bib cock each 11.00
Supply, fitting and fixing best quality CP pillar cock ect. (Cotto or
13.12 equivalent). Complete approved and accepted by the Engineer
6- Sub distribution board, IP42, include the terminal block each 3.00
Sub - Total 1
2.2.4_ Concrete for ground floor beam A350 - 7 - CW - 1908 cum 14.87
2.2.5_ Concrete for beam +5.35m A350 - 7 - CW - 1908, 1909 cum 9.50
2.2.10_ Concrete for ramp slope A350 - 7 - CW - 1902, 1903 cum 2.46
2.2.11_ Concrete for gutter slab A350 - 7 - CW - 1904 cum 3.26
4.1.7_ Reinforcement for ground floor slab A350 - 7 - CW - 1910, 1911 kg 1,060.63
6.1.3_ Plaster to below surface of roof slab A350 - 7 - CW - 1907, 1908 sqm 138.69
6.2 Waterproofing
6.2.1_ Three layer waterproofing by sika grout for gutter slab A350 - 7 - CW - 1902-1904 sqm 23.28
Sub - Total 6
7 Tiles & Stone Work
Homogenious mirror polish tile 600x600 mm for floor
Suppling, fitting and fixing tiles with cement sand (F.M. 1.2) mortar
(1:4) base and raking out the joints with white cement including
7.1 cutting and laying the tiles in proper way and finishing with care
Sub - Total 7
8 Door & Window
8.1 Door
8.1.1_ Single leaf stainless steel door DO-01 (1000x2100mm) A350-7-CW-1905, 1906 sqm 8.40
8.1.2_ Stainless steel collapsible gate DO-02 (4000x3000mm) A350-7-CW-1905, 1906 sqm 24.00
8.1.3_ Stainless steel collapsible gate DO-03 (3000x3000mm) A350-7-CW-1905, 1906 sqm 18.00
Sub - Total 1
a) 450 mm dia
b) Depth up to 38 m A350-7-CW-2112 Rm 684.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code ACI/BNBC/ASTM
& cement conforming to BDS EN-197-1- CEM -1,52.5 N / ASTM-C
150 Type – I, best quality coarse sand [Sylhet sand or coarse sand of
equivalent F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking crushed stone chips,
screening through proper sieves, making, placing re-bar cage & binding
ms pipes in position, placing and removing tri-pod as per requirement,
pouring the concrete in bore-hole with the help of a tremie pipe,
maintaining the tremie pipe immersed in concrete by at least 1 meter
2.2 throughout the period of concreting, maintaining required slump, etc. A350-7-CW-2112 cum 108.73
mixing the aggregates in diginal batching plant, casting in bore holes,
acertaining the strength by trial mix design all complete including all
cost of water, electricity, plant & machinery, bentonite, admixture
testing of materials and concrete etc and other charges as per design,
drawing etc all complete approved and accepted by the Engineer.
Concrete should prepared by Digital batching plant, strength may be
acertained by trail mix design.
a) For 140 tonne load for 1 No. test per test 1.00
Sub - Total 2
3 Concrete Work
Mass concrete
Grade 9 Mpa, 20mm down well graded crushed stone chips; produced
by mixer, casting in forms in/c supplying & laying of single layer
3.1
polythene sheet weighing 6.5 kg/Sqm with allowances for lapping
complete in all respect and accepted by the Engineer.
3.3.2_ Concrete for pedestal column and column A350-7-CW-2113-2115 cum 1.98
3.3.6_ Concrete for ground floor slab elv +1.000m A350-7-CW-2113-2115 cum 84.00
4.1.2_ Formwork for pedestal column and column A350-7-CW-2113-2115 sqm 24.00
6.1.1_ For wall from +1.000 to +6.450 and roof A350-7-CW-2108/2109 cum 67.99
Normal brick work 250mm to 375mm thick
Brick work of width one brick or one and a half brick length with first
class bricks in cement sand (F.M. 1.2) mortar (1:6), in superstructure
including raking out joints, filling the interstices with mortar, cleaning
and soaking bricks at least 24 hours before use and washing of sand,
6.2 necessary scaffolding, curing at least 7 days etc. all complete
(measurement to given as 250mm width for one brick length and
375mm for one brick and a half brick length). (Cement: CEM-I)
11.3 Galvanized Steel wire rope D14mm for roof A350-7-CW-2118-2129 m 110.64
11.8 Roof Insulation (fiber glass with galvanized mesh) A350-7-CW-2118-2129 sqm 60.00
Electrical equipment
12.1
Providing and fixing electrical equipment to position
Electrical wire and cable (include conduit pipes, junction box with
12.3
terminal block and concealed)
1- (NYY) / XLPE insulated & PVC sheathed, 0.6/1KV, Cu, Single -
m 300.00
core 1c x 2.5 mm²
Sub - Total 11
TOTAL
Sub - Total 1
a) 600 mm dia
b) Depth up to 22 m A350-7-CW-2215 m 1,056.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code
ACI/BNBC/ASTM & cement conforming to BDS EN-197-1- CEM
-1,52.5 N / ASTM-C 150 Type – I, best quality coarse sand [Sylhet
sand or coarse sand of equivalent F.M.2.2], 20 mm down well graded
crushed stone chips conforming to ASTM C-33, including breaking
crushed stone chips, screening through proper sieves, making, placing
re-bar cage & binding ms pipes in position, placing and removing tri-
pod as per requirement, pouring the concrete in bore-hole with the
2.2 help of a tremie pipe, maintaining the tremie pipe immersed in A350-7-CW-2215 cum 298.43
concrete by at least 1 meter throughout the period of concreting,
maintaining required slump, etc. mixing the aggregates in batching
plant, casting inbore holes, all complete including water, electricity,
testing of materials and concrete etc and other charges as per design,
drawing etc all complete approved and accepted by the Engineer.
Concrete should prepared by Digital batching plant, strength may be
acertained by trail mix design.
3.2.4_ Concrete for 1st floor beam A350-7-CW-2220, 2221 cum 10.90
3.2.5_ Concrete for 2nd floor beam A350-7-CW-2222, 2223 cum 10.90
3.2.9_ Concrete for 1st floor slab A350-7-CW-2220, 2221 cum 15.51
3.2.10_ Concrete for 2nd floor slab A350-7-CW-2222, 2223 cum 15.51
4.1.5_ Formwork for 2nd floor beam A350-7-CW-2222, 2223 sqm 88.11
4.1.8_ Formwork for 1st floor slab A350-7-CW-2220, 2221 sqm 126.40
4.1.9_ Formwork for 2nd floor slab A350-7-CW-2222, 2223 sqm 126.40
6.1.1_ Ground floor wall include balcony wall A350-7-CW-2209/2203 cum 47.77
6.1.2_ 1st floor wall include balcony wall A350-7-CW-2209/2203 cum 37.67
6.1.3_ 2nd floor wall include balcony wall A350-7-CW-2209/2203 cum 38.99
Exposed brick work for interior wall
Exposed 125mm thick pointing extra ordinary ornamental brick work
with automatic machine made 10 holes first class bricks (Mirpur
Ceramics or equivalent) in cement sand (F.M.1.2) mortar (1:4) and
making bond with connected walls including necessary scaffolding,
6.2 raking out joints, cleaning and soaking the bricks for at least 24 hours
before use and washing of sand curing at least for 7 days in all floors
including cost of water, electricity and other charges ect. all complete
and acceplete and accepted by the Engineer. (Cement: CEM-I) in
ground floor.
6.2.1_Ground floor A350-7-CW-2203-2205 sqm 76.07
7.1.4_ Plaster to ceiling and below surface of roof slab A350-7-CW-2203-2205 sqm 36.08
7.2 Waterproofing
7.2.1_ Three layers waterproofing by sika for roof slab A350-7-CW-2203-2205 sqm 36.08
Sub - Total 7
8 Tiles & Stone Work
Homogenious mirror polish tile 600x600 mm for floor
Suppling, fitting and fixing tiles with cement sand (F.M. 1.2) mortar
8.1 (1:4) base and raking out the joints with white cement including
cutting and laying the tiles in proper way and finishing with care
5mm thick glass Thai Aluminium frame curtain windowas per design,
9.4 drawing, accepted by the Engineer
9.4.1_ Single shutter curtain window CWD-01 (600x600mm)
including grill with 12mm square bar as per drawing, design, A350-7-CW-2209-2211 sqm 3.60
specification etc. all complete & accepted by the Engineer.
12.6 Reducer
13.8 Flush faucet for toilet bowl (Cotto or equivalent) each 24.00
7- Sub distribution board, IP42, include the terminal block each 3.00
8- Distribution board, IP42Enclosures each 1.00
9- Socket (3-pin 6A ) each 34.00
10- Socket (3-pin 15A)
Providing & fixing 250 volts, single phase, 3-pin, 13/15/16amps.
Combined switch socket outlet (concealed type) manufactured and
tested in accordance with relevant IEC standards and manufactured
and tested in accordance with relevant IEC standards and approved by
BSTI mounted on required size 18 SWG galvanized plain sheet board each 12.00
of 76.2mm. (3”) depth all electrical contacts shall be of brass/copper
(Dynamic/MEP/ SK/Metro/Super Star or equivalent, local made).)
Sub - Total 1
a) 600 mm dia
b) Depth up to 22 m A350-7-CW-2322, 2323 m 2,816.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code ACI/BNBC/ASTM
& cement conforming to BDS EN-197-1- CEM -1,52.5 N / ASTM-C
150 Type – I, best quality coarse sand [Sylhet sand or coarse sand of
equivalent F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking crushed stone chips,
screening through proper sieves, making, placing re-bar cage & binding
ms pipes in position, placing and removing tri-pod as per requirement,
pouring the concrete in bore-hole with the help of a tremie pipe,
maintaining the tremie pipe immersed in concrete by at least 1 meter
throughout the period of concreting, maintaining required slump, etc.
2.2 A350-7-CW-2322, 2323 cum 795.80
mixing the aggregates in diginal batching plant, casting in bore holes,
acertaining the strength by trial mix design all complete including all
cost of water, electricity, plant & machinery, bentonite, admixture
testing of materials and concrete etc and other charges as per design,
drawing etc all complete approved and accepted by the Engineer.
Concrete should prepared by Digital batching plant, strength may be
acertained by trail mix design.
3.2.11_ Concrete for slab at elv +10.780m A350-7-CW-2336, 2337 cum 2.71
3.2.12_ Concrete for roof slope slab A350-7-CW-2336, 2337 cum 51.01
3.2.15_ Concrete for 2nd floor and roof column A350-7-CW-2328 cum 24.24
4.1.10_ Formwork for slab elv +10.780 A350-7-CW-2336, 2337 sqm 22.61
4.1.11_ Formwork for roof slope slab A350-7-CW-2336, 2337 sqm 425.08
4.3.14_ Formwork for 2nd floor and roof column A350-7-CW-2328 sqm 245.92
6.1.1_ Ground floor wall include balcony wall A350-7-CW-2305-2308 cum 111.47
6.1.2_ 1st floor wall include balcony wall A350-7-CW-2305-2308 cum 92.38
6.1.3_ 2nd floor wall include balcony wall A350-7-CW-2305-2308 cum 96.60
Exposed brick work for interior wall
Exposed 125mm thick pointing extra ordinary ornamental brick work
with automatic machine made 10 holes first class bricks (Mirpur
Ceramics or equivalent) in cement sand (F.M.1.2) mortar (1:4) and
making bond with connected walls including necessary scaffolding,
6.2 raking out joints, cleaning and soaking the bricks for at least 24 hours
before use and washing of sand curing at least for 7 days in all floors
including cost of water, electricity and other charges ect. all complete
and acceplete and accepted by the Engineer. (Cement: CEM-I) in
ground floor.
6.2.1_ Ground floor A350-7-CW-2305-2308 sqm 92.36
6.2.2_ 1st floor A350-7-CW-2305-2308 sqm 86.73
6.2.3_ 2nd floor A350-7-CW-2305-2308 sqm 90.55
7.1.3_ Plaster to ceiling and below surface of roof slab A350-7-CW-2307 sqm 425.08
7.2.1_ Three layers waterproofing by sika for gutter slab A350-7-CW-2305-2308 sqm 107.97
Sub - Total 7
8 Tiles & Stone Work
Homogenious mirror polish tile 600x600 mm for floor
Suppling, fitting and fixing tiles with cement sand (F.M. 1.2) mortar
8.1 (1:4) base and raking out the joints with white cement including cutting
and laying the tiles in proper way and finishing with care
5mm thick glass Thai Aluminium frame curtain window as per design,
9.4 drawing, accepted by the Engineer
12.5 Tee
12.7 Elbow
13.7 Flush faucet for toilet bowl (Cotto or equivalent) each 24.00
6- Sub distribution board, IP42 include the terminal block each 3.00
7- Distribution board, IP42 Enclosures each 1.00
8- Socket (3-pin6A ) each 49.00
9- Socket (3-pin15A)
Providing & fixing 250 volts, single phase, 3-pin, 13/15/16amps.
Combined switch socket outlet (concealed type) manufactured and
tested in accordance with relevant IEC standards and manufactured and
tested in accordance with relevant IEC standards and approved by BSTI
mounted on required size 18 SWG galvanized plain sheet board of each 22.00
76.2mm. (3”) depth all electrical contacts shall be of brass/copper
(Dynamic/MEP/ SK/Metro/Super Star or equivalent, local made).)
Sub - Total 1
a) 600 mm dia
b) Depth up to 22 m A350 - 7- CW - 2405, 2407 m 352.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code ACI/BNBC/ASTM
& cement conforming to BDS EN-197-1- CEM -1,52.5 N / ASTM-C
150 Type – I, best quality coarse sand [Sylhet sand or coarse sand of
equivalent F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking crushed stone chips,
screening through proper sieves, making, placing re-bar cage & binding
ms pipes in position, placing and removing tri-pod as per requirement,
pouring the concrete in bore-hole with the help of a tremie pipe,
2.2 maintaining the tremie pipe immersed in concrete by at least 1 meter A350 - 7- CW - 2405, 2407 cum 99.48
throughout the period of concreting, maintaining required slump, etc.
mixing the aggregates in diginal batching plant, casting in bore holes,
acertaining the strength by trial mix design all complete including all
cost of water, electricity, plant & machinery, bentonite, admixture
testing of materials and concrete etc and other charges as per design,
drawing etc all complete approved and accepted by the Engineer.
Concrete should prepared by Digital batching plant, strength may be
acertained by trail mix design.
2.6
ii) Double PIT (pile integrity test)
Conducting low strain dynamic testing of pile as per ASTM D5882- The
standard method of testing by a qulifified and approved PIT expert,
preparing pile heads and providing all relevant materials, equipment,
result in standard forms and compiling test report with recommendations A350 - 7- CW - 2405, 2407 7.00
on the test etc. complete in all respect approve and accepted by the
Engineer.
3.2.2_ Concrete for ground floor beam A350-7-CW-2108, 2109 cum 6.86
3.2.3_ Concrete for beam elv +4.380 A350-7-CW-2108, 2109 cum 3.35
4.1.2_ Formwork for ground floor beam A350-7-CW-2108, 2109 sqm 44.12
4.1.3_ Formwork for beam elv +4.380 A350-7-CW-2108, 2109 sqm 22.40
Sub - Total 4
7.2.2_ Cement mortar with sika latex grade 100 for tank A350-7-CW-2106,2107 sqm 187.40
7.2.3_ Three layers epoxy painting for tank A350-7-CW-2106,2107 sqm 187.40
Sub - Total 6
8 Tiles & Stone Work
Homogenious mirror polish tile 600x600 mm for floor
Suppling, fitting and fixing tiles with cement sand (F.M. 1.2) mortar
8.1 (1:4) base and raking out the joints with white cement including cutting A350-7-CW-2101-2103 sqm 38.36
and laying the tiles in proper way and finishing with care
8.2 Mirpur ceramic 75x225 mm, dark colour for outside ground floor beam A350-7-CW-2102, 2103 sqm 15.12
Roof tile
8.3 Supplying, fitting and fixing country made (Mirpur Ceramic / A350-7-CW-2102, 2103 sqm 60.27
equivalent) roof tile, with adhesive motar
Sub - Total 7
9 Door & Window
Wooden (matured and seasoned Mehaghani) entry door and frame
Supplying and making solid wooden door for all floors with matured
natural seasoned wood of required size including painting two coats of
9.1 coal tar to the surface in contact with all, fitting and fixing in position.
Frame (size 250x62mm) & shutter as per design, drawing, accepted by
the Engineer
11.1.1_ For tube-wells beyond 200 meter depth per set 1.00
Boring
Execution 350mm dia of boring through all sorts of strata by reverse
circulation or any other approved method. Boring for 350mm dia
11.2 vertical hole up to designed depth and collection of soil samples at every
3 meter interval or as required and at every change in soil stratum
including sinking and with drawing necessary casing pipe and all
necessary arrangements complete
1.5 Sand filling to elv +1.00 with compaction k=0.95 A350-7-CW-2501/2513 - 2517 cum 43.97
Sub - Total 1
a) 600 mm dia
b) Depth up to 22 m A350-7-CW-2512 Rm 792.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code ACI/BNBC/ASTM
& cement conforming to BDS EN-197-1- CEM -1,52.5 N / ASTM-C
150 Type – I, best quality coarse sand [Sylhet sand or coarse sand of
equivalent F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking crushed stone chips,
screening through proper sieves, making, placing re-bar cage & binding
ms pipes in position, placing and removing tri-pod as per requirement,
pouring the concrete in bore-hole with the help of a tremie pipe,
maintaining the tremie pipe immersed in concrete by at least 1 meter
2.2 throughout the period of concreting, maintaining required slump, etc. A350-7-CW-2512 cum 223.82
mixing the aggregates in diginal batching plant, casting in bore holes,
acertaining the strength by trial mix design all complete including all
cost of water, electricity, plant & machinery, bentonite, admixture
testing of materials and concrete etc and other charges as per design,
drawing etc all complete approved and accepted by the Engineer.
Concrete should prepared by Digital batching plant, strength may be
acertained by trail mix design.
3.2.4_ Concrete for 1st floor beam +4.150 A350-7-CW-2518/2519 cum 9.61
3.2.8_ Concrete for 1st floor slab +4.150 A350-7-CW-2501/2518 cum 1.10
4.1.4_ Formwork for 1st floor beam at +4.150 A350-7-CW-2518/2519 sqm 76.63
4.1.7_ Formwork for 1st floor slab at +4.150 A350-7-CW-2501/2518 sqm 152.29
7.2 Waterproofing
11.2 Stainless steel handrail with wooden top rail for staircase A350-7-CW-2505 m 6.11
Sub - Total 11
Wooden table with stainless steel leg and frame (1000x1000 mm) with
12.2 approved wood, frame etc. all complete accepted by the Engineer. A350-7-CW-2501 each 7.00
Wooden chair with stainless steel leg and frame with approved wood,
12.3 frame etc. all complete accepted by the Engineer. A350-7-CW-2501 each 46.00
Sub - Total 12
13 Water Supply/ Waste water System
A350-7-DW-3-2505, A350-7-DW-2-2505
Supply and installation of foreign made food grade stainless steel
(SS304) thickness 1.8mm water tank including supply of hardware,
13.1 consumables, fittings etc. all complete approved and accepted by the
Engineer
13.5 Tee
13.6 Elbow
13.6.1_90 degree elbow(uPVC ɸ110) each 2.00
13.9.1_ Clear 450x450 mm and depth 450 to 600 mm, average 525 mm
for single 150 mm dia R.C.C.pipes and 400 mm uPVC pipe each 3.00
Sub - Total 13
14 Sanitary Accessories (Cotto or Equipment)
A350-7-CW-2506,2507, A350-7-DW-2-2505
Toilet bowl
Supplying, fitting, and fixing European type of toilet bowl. in/c plastic
14.1 seat cover, cistern system, preparing the base with cement concrete and each 3.00
with wire mesh or roads if necessary, including making holes and
fitting, fixing, finishing etc.
14.2 Bowl uniral each 3.00
Hand wash Basin
Supplying glazed vitreous W/H Wash Basin in/c pedestal approx. size
656×510×845, 26kg by weight including fitting, fixing the same in
position with heavy type C.I. Brackets. 30 mm dia PVC waste water
14.3 pipe with brass coupling (not exceeding 750 mm in length). 12mm each 3.00
plastic lead (connection) pipe with brass coupling, basin waste with
chain plug including making holes in walls and floors and fitting with
wooden blocks, screws, finishing etc,
14.7 Flush faucet for toilet bowl (Cotto or equivalent) each 3.00
6- Sub distribution board, IP42, include the terminal block each 1.00
7- Distribution board, IP42 Enclosures each 1.00
8- Socket (3-pin 6A) each 13.00
9- LED Tube light set (3 x 10W)
Providing & fixing the 3 x 2’× 10 watt Louver type LED tube light
fitting (False ceiling mounted concealed type) with V- grid louver of
following manufacturers (as per picture No. 12.37) consisting of power
coated 22 SWG sheet steel frame of min. length 600mm & breath
600mm, symmetrical mirror reflector of anodized aluminum, superior each 21.00
quality electronic ballast with one year guarantee, holder, necessary
wiring with 2 x 0.4 sq.mm uPVC insulated (stranded) flexible FR wire,
earth terminal etc.
1.2 Demolishing and removing of one floor existing canteen 20.5m x 5.5m lot 1.00
Sub - Total 1
Earth work in excavation in all kinds of soil for foundation trenches layout,
providing center lines, local bench-mark pillars, levelling, ramming and preparing the
base, fixing bamboo spikes and marking layout with chalk powder, providing
2
necessary tools and plants, protecting and maintaining the trench dry etc., stacking,
clearing the excavated earth at a safe distance out of the area enclosed by the layout
etc.
Layout and marking for earth work in excavation in foundation accepted by the
2.1 A350-7-CW-2601 sqm 516.80
Engineer.
Earth work in excavation in foundation trenches up to 1.5 m depth and maximum
2.2 A350-7-CW-2601, 2617-2619 cum 468.70
10 m lead: in soft clayey soil/loose sand/silt
Mobilization and cleaning site before commencing actual physical work and
2.3 during contract period and demobilization after Completion of the Works under A350-7-CW-2601 sqm 516.80
contract accepted by Engineer.
Earth filling in foundation trenches/Back filling and plinth in 150mm layers with
earth available within 90 m of the building site minimum dry density of 95% with
2.4 optimum moisture content (Modified proctor test) including carrying, watering, A350-7-CW-2601, 2617-2619 cum 442.42
levelling, dressing and compacting to a specified percentage each layer upto finished
level etc. all complete and accepted by the Engineer.
Clearing and disposing of excavated earth from the construction site by truck or
any other means to a place within 30 km radius of the city or town area including
2.5 A350-7-CW-2601, 2617-2619 cum 150.93
loading, unloading at both ends, leveling and dressing the carried earth etc. complete
accepted by the Engineer.
Sub - Total 2
a) 600 mm dia
b) Depth up to 22 m A350-7-CW-2616 m 1,210.00
Cast in situ pile with RCC works of required slump by adding water reducing
admixture with 25 Mpa relates to mix ratio (1:1.5:3) on standard cylinders as per
standard practice of Code ACI/BNBC/ASTM & cement conforming to BDS EN-197-
1- CEM -1,52.5 N / ASTM-C 150 Type – I, best quality coarse sand [Sylhet sand or
coarse sand of equivalent F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking crushed stone chips, screening
through proper sieves, making, placing re-bar cage & binding ms pipes in position,
placing and removing tri-pod as per requirement, pouring the concrete in bore-hole
with the help of a tremie pipe, maintaining the tremie pipe immersed in concrete by
3.2 at least 1 meter throughout the period of concreting, maintaining required slump, etc. A350-7-CW-2616 cum 341.95
mixing the aggregates in diginal batching plant, casting in bore holes, acertaining the
strength by trial mix design all complete including all cost of water, electricity, plant
& machinery, bentonite, admixture testing of materials and concrete etc and other
charges as per design, drawing etc all complete approved and accepted by the
Engineer. Concrete should prepared by Digital batching plant, strength may be
acertained by trail mix design.
Conducting static load test as per ASTM D1143 or equivalent standard for the cast-
in-situ/pre-cast pile providing required scaffolding, bracing, jacks, pressure test
gauge, loading unloading, Kentledge and other plants and equipment including
staging, mobilization, demobilization, hire charge, gunny bags, sand and filling
sacs/gunny bags for loading, record readings and preparation of results in standard
3.7 forms and other incidental charges per standard practice and procedures including A350-7-CW-2616
submission of load test report, furnishing all graph and chart etc. complete in all
respects approved and accepted by the Engineer (Minimum two cyclic loading).
Before commencing load test, Contractor shall submit method statement for
conducting load test to the Engineer for approval. However, Engineer’s approval
shall not relieve the Contractor of his responsibilities and obligations under Contract.
4.2.10_ Concrete for 1st floor slab (+6.000) A350-7-CW-2628,2629 cum 29.29
4.2.15_ Concrete for column from +6.000 to +12.000 A350-7-CW-2622 cum 10.62
5.1.9_ Formwork for 1st floor slab concrete (+6.000) A350-7-CW-2628,2629 sqm 303.24
5.1.15_ Formwork for column from +6.000 to +12.000 A350-7-CW-2622 sqm 92.40
5.1.15_ Formwork for column from +12.000 to +20.000 A350-7-CW-2622 sqm 30.40
5mm thick glass with Thai Aluminium frame curtain window as per design, drawing,
10.3 accepted by the Engineer
10.3.1_ Double leaf window WD-01 (2100x1400mm) including grill with 12mm
square bar as per drawing, design, specification etc. all complete & accepted by the A350-7-CW-2611, 2612 sqm 5.32
Engineer.
5mm thick glass with Thai Aluminium frame curtain window as per design, drawing,
10.4
accepted by the Engineer
10.4.1_ Curtain window CW-01 (1800x2700mm) including grill with 12mm square
bar as per drawing, design, specification etc. all complete & accepted by the A350-7-CW-2611, 2612 sqm 30.83
Engineer.
10.4.2_ Curtain window CW-02 (1800x3300mm) including grill with 12mm square
bar as per drawing, design, specification etc. all complete & accepted by the A350-7-CW-2611, 2612 sqm 5.48
Engineer.
10.4.3_ Curtain window CW-03 (600x600mm) including grill with 12mm square bar
A350-7-CW-2611, 2612 sqm 0.36
as per drawing, design, specification etc. all complete & accepted by the Engineer.
Sub - Total 10
11 Finishing Work
Emulsion Paint
Plastic emulsion of approved best quality and colour delivered from authorized local
agent of the manufacturere in a sealed container, applying to wall and ceiling in two
coats over lime putty of specified brand applied on primer or sealer elapsing specified
11.1 time for drying/recoating including cleaning drying, making free from dirt, grease,
wax, removing all chalked and scaled materials, fungus, mending good the surface
defects, sand papering the surface and necessary scaffolding, spreading by brush/
roller/ spray etc.
12.5 Tee
12.6 Reducer
12.7 Elbow
Toilet bowl
Supplying, fitting, and fixing European type of toilet bowl. in/c plastic seat cover,
13.1 each 3.00
cistern system, preparing the base with cement concrete and with wire mesh or roads
if necessary, including making holes and fitting, fixing, finishing etc.
13.8 Flush faucet for toilet bowl (Cotto or equivalent) each 3.00
2.2.4_ Concrete for ground floor beam A350 - 7 - CW - 2706 cum 6.30
3.1.4_ Formwork for ground floor beam A350 - 7 - CW - 2706 sqm 42.00
6.1.4_ Plaster to below surface of roof slab A350 - 7 - CW - 2701, 2703, 2709 sqm 64.39
6.1.5_ Plaster to entry steps A350 - 7 - CW - 2701, 2703, 2709 sqm 2.67
6.2 Waterproofing
6.2.1_ Three layer waterproofing by sika grout for gutter slab A350 - 7 - CW - 2701, 2703, 2709 sqm 56.40
Sub - Total 6
7 Tiles & Stone Work
Homogenious mirror polish tile 600x600 mm for floor
Suppling, fitting and fixing tiles with cement sand (F.M. 1.2) mortar
7.1 (1:4) base and raking out the joints with white cement including
cutting and laying the tiles in proper way and finishing with care
8.1.2_ Stainless steel collapsible gate DO-02 (3000x3000mm) A350-7-CW-2704 sqm 9.00
5mm thick glass Thai Aluminium frame sliding window as per
8.2
design, drawing, accepted by the Engineer
8.2.1_ Double shutter window WD-01 (1200x1400mm) including
grill with 12mm square bar as per drawing, design, specification A350-7-CW-2704 sqm 3.36
etc. all complete & accepted by the Engineer.
8.3 Ventilation A350-7-CW-2705 sqm 5.28
Sub - Total 8
Structural Steel
9
9.1 Galvanized grating F40x3 mm for trench cover A350 - 7 - CW - 2703 sqm 27.77
Sub - Total 9
10 Electrical Work
Ref: A350-7-LA-2701
Electrical equipment
10.1
Providing and fixing electric equipment to position
1- Wall mounted LED tube light
Providing & fixing the 1×4’×20- LED tube light consisting of
powder coated 22 SWG sheet steel frame of min. length 1226mm &
breadth 60mm, superior quality electronic ballast with one year each 4.00
guarantee, holder, necessary wiring with 2× 0.4 sq mm PVC
insulated (stranded) flexible FR wire, earth terminal etc.
1.5 Sand filling to elv +1.00 with compaction k=0.95 A350-7-CW-2805-2809 cum 73.20
Clearing and disposing of excavated earth from the construction
site by truck or any other means to a place within 30 km radius of the
1.6 city or town area including loading, unloading at both ends, leveling A350-7-CW-2805-2809 cum 210.52
and dressing the carried earth etc. complete accepted by the
Engineer.
Sub - Total 1
a) 600 mm dia
b) Depth up to 22 m A350-7-CW-2805 Rm 176.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code
ACI/BNBC/ASTM & cement conforming to BDS EN-197-1- CEM
-1,52.5 N / ASTM-C 150 Type – I, best quality coarse sand [Sylhet
sand or coarse sand of equivalent F.M.2.2], 20 mm down well graded
crushed stone chips conforming to ASTM C-33, including breaking
crushed stone chips, screening through proper sieves, making,
placing re-bar cage & binding ms pipes in position, placing and
removing tri-pod as per requirement, pouring the concrete in bore-
hole with the help of a tremie pipe, maintaining the tremie pipe
immersed in concrete by at least 1 meter throughout the period of
2.2 A350-7-CW-2805 cum 49.76
concreting, maintaining required slump, etc. mixing the aggregates in
diginal batching plant, casting in bore holes, acertaining the strength
by trial mix design all complete including all cost of water,
electricity, plant & machinery, bentonite, admixture testing of
materials and concrete etc and other charges as per design, drawing
etc all complete approved and accepted by the Engineer. Concrete
should prepared by Digital batching plant, strength may be
acertained by trail mix design.
3.2.7_ Concrete for ground floor beam at +0.550 A350-7-CW-2807-2809 cum 14.02
4.1.7_ Formwork for ground floor beam at +0.550 A350-7-CW-2807-2809 sqm 69.60
5.1.10_ Reinforcement for ground floor slab and ramp A350-7-CW-2807 kg 890.25
7.2 Waterproofing
7.2.1_ Three layers waterproofing by sika for gutter slab A350-7-CW-2801-2803 sqm 48.65
Sub - Total 7
8 Tiles & Stone Work
Homogenious mirror polish tile 600x600 mm for floor
Suppling, fitting and fixing tiles with cement sand (F.M. 1.2) mortar
8.1 (1:4) base and raking out the joints with white cement including A350-7-CW-2801-2803 sqm 87.75
cutting and laying the tiles in proper way and finishing with care
Mirpur ceramic 75x225 mm, dark colour for outside ground floor
8.2 beam A350-7-CW-2801-2803 sqm 56.21
Roof tile
8.3 Supplying, fitting and fixing country made (Mirpur Ceramic / A350-7-CW-2801-2803 sqm 60.17
equivalent) roof tile, with adhesive motar
Sub - Total 8
Sub - Total 1
2.2.2_ Concrete for ground floor beam A350-7-CW-29a04, 29a05 cum 1.92
2.2.3_ Concrete for beam elv +4.380 A350-7-CW-29a04, 29a05 cum 1.60
3.1.2_ Formwork for ground floor beam A350-7-CW-29a04, 29a05 sqm 15.36
3.1.3_ Formwork for beam elv +4.380 A350-7-CW-29a04, 29a05 sqm 16.80
6.2.1_ Th layers Waterproofing by sika for gutter slab A350-7-CW-29a01, 29a02 sqm 2.40
6.2.3_ Motal cement with sika latex grade 100 for tank A350-7-CW-29a01, 29a02 sqm 187.70
6.2.4_ Three layers epoxy painting for tank A350-7-CW-29a01, 29a02 sqm 187.70
Sub - Total 6
7 Tiles & Stone Work
Homogenious mirror polish tile 600x600 mm for floor
Suppling, fitting and fixing tiles with cement sand (F.M. 1.2) mortar
7.1 (1:4) base and raking out the joints with white cement including cutting A350-7-CW-29a01- 29a03 sqm 25.00
and laying the tiles in proper way and finishing with care
7.2 Mirpur ceramic 75x225 mm, dark colour for outside ground floor beam A350-7-CW-29a01- 29a03 sqm 8.40
Roof tile
7.3 Supplying, fitting and fixing country made (Mirpur Ceramic / A350-7-CW-29a01- 29a03 sqm 60.27
equivalent) roof tile, with adhesive motar
Sub - Total 7
8 Door & Window
Wooden (matured & seasoned Mehaghani) entry door and frame
Supplying and making solid wooden door for all floors with matured
natural seasoned wood of required size including painting two coats of
8.1
coal tar to the surface in contact with all, fitting and fixing in position.
Frame (size 250x62mm) & shutter as per design, drawing, accepted by
the Engineer.
8.1.1_ Single leaf door DO-01 (2100x1000X38mm) including
A350-7-CW-29a03 cum 0.16
varnishing and frence polishing
5mm thick glass Thai Aluminium frame sliding window as per design,
8.2
drawing, accepted by the Engineer
8.2.1_ Double shutter window WD-01 (1200x1200mm)including grill
with 12mm square bar as per drawing, design, specification etc. all A350-7-CW-29a03 sqm 2.88
complete & accepted by the Engineer.
Sub - Total 8
11.1.1_ For tube-wells beyond 200 meter depth A350-7-CW-29a01-29a03 per set 1.00
Filling of the bore hole around the tube well from top the shrouding up
to the bottom of sanitary seal by withdrawn of selected soil or clay or
11.6 A350-7-CW-29a01-29a03 rm 300.00
other harmful substances and filled by coarse sand
Sub - Total 11
12 Electrical Work
Electrical equipment
12.1
Providing and fixing electric equipment to position
1- Wall mounted LED tube light
Providing & fixing the 1×4’×20-watt LED tube light consisting of
powder coated 22 SWG sheet steel frame of min. length 1226mm &
breadth 60mm, superior quality electronic ballast with one year each 2.00
guarantee, holder, necessary wiring with 2× 0.4 sq mm PVC insulated
(stranded) flexible FR wire, earth terminal etc.
Sub - Total 1
a) 600 mm dia
b) Depth up to 38 m A350-7-CW-3006 m 456.00
Cast in situ pile with RCC works of required slump by adding water
reducing admixture with 25 Mpa relates to mix ratio (1:1.5:3) on
standard cylinders as per standard practice of Code ACI/BNBC/ASTM
& cement conforming to BDS EN-197-1- CEM -1,52.5 N / ASTM-C
150 Type – I, best quality coarse sand [Sylhet sand or coarse sand of
equivalent F.M.2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking crushed stone chips,
screening through proper sieves, making, placing re-bar cage & binding
ms pipes in position, placing and removing tri-pod as per requirement,
pouring the concrete in bore-hole with the help of a tremie pipe,
maintaining the tremie pipe immersed in concrete by at least 1 meter
2.2 throughout the period of concreting, maintaining required slump, etc. A350-7-CW-3006 cum 128.87
mixing the aggregates in diginal batching plant, casting in bore holes,
acertaining the strength by trial mix design all complete including all
cost of water, electricity, plant & machinery, bentonite, admixture
testing of materials and concrete etc and other charges as per design,
drawing etc all complete approved and accepted by the Engineer.
Concrete should prepared by Digital batching plant, strength may be
acertained by trail mix design.
Back filling in 150mm layers with black sand having minimum dry density
of 95% with optimum moisture content (Modified proctor test) including
1.2 carrying, watering, levelling, dressing and compacting to a specified cum 89.18
percentage each layer upto finished level etc. all complete and accepted by
the Engineer.
Back filling in 150mm layers with undisturbed soil having minimum dry
density of 95% with optimum moisture content (Modified proctor test)
1.3 including carrying, watering, levelling, dressing and compacting to a cum 240.51
specified percentage each layer upto finished level etc. all complete and
accepted by the Engineer.
1.3 Compaction k= 0.98 etc. all complete accepted by the Engineer cum 3,129.50
6 Drainage equipment
1.5 Compaction to achieve k = 0.95 & accepted by the Engineer. cum 819.02
Steel formwork
Include making, placing shutter in position and maintaining true to
4.2 plumb, making shutter in position and maintaining true to plumb, sqm 29.04
making shutter water-tight properly, placing reinforcement in position.
all complete approved and accepted by the Engineer.
Brick work
Brick work of width one brick or one and a half brick length with first
class bricks in cement sand (F.M. 1.2) mortar (1:6), in superstructure
including raking out joints, filling the interstices with mortar, cleaning
and soaking bricks at least 24 hours before use and washing of sand,
4.3 necessary scaffolding, curing at least 7 days etc. all complete cum 24.74
(measurement to given as 250mm width for one brick length and
375mm for one brick and a half brick length). (Cement: CEM-I)
Master control panel MCC70, Enclosure IP54, 415/230 V, 85KA,50HZ (Include: MCCB, Magnetic
2.3 contactor, Relay, Overload, timer, selector switch, signal lamp, wiring, Cable gland,etc) set 1.00
Sheet steel clad powder coated (16 SWG-1.6mm), IEC Standard with type tested certificate.
Master control panel MCC71A, Enclosure IP54, 415/230 V, 85 KA, 50HZ ( Include: MCCB,
2.4 Magnetic contactor, Relay, Overload, timer, selector switch, signal lamp, wiring, Cable gland, etc) set 1.00
Sheet steel clad powder coated (16 SWG- 1.6mm), IEC Sandard with type tested certificate.
Master control panel MCC71B, Enclosure IP54, 415/230 V, 85 KA, 50HZ ( Include: MCCB,
2.5 Magnetic contactor, Relay, Overload, timer, selector switch, signal lamp, wiring, Cable gland, etc) set 1.00
Sheet steel clad powder coated (16 SWG-1.6mm), IEC Standard with type tested certificate.
Master control panel MCC72, Enclosure IP54, 415/230 V, 85 KA, 50HZ ( Include: MCCB, Magnetic
2.6 contactor, Relay, Overload, timer, selector switch, signal lamp, wiring, Cable gland, etc) set 1.00
Sheet steel clad powder coated (16 SWG-1.6mm), IEC Standard with type tested certificate.
Master control panel MCCSS, Enclosure IP54, 415/230 V, 85 KA, 50HZ (Include: MCCB, Magnetic
2.7 contactor, Relay, Overload, timer, selector switch, signal lamp,wiring, Cable gland, etc) set 1.00
Sheet steel clad powder coated (16 SWG-1.6MM), IEC Standard with type tested certificate
Electrical and control panel (HPP), Enclosure IP54, 415/230V, 50HZ for the hydraulic extractor (SE-
2.8 11KW), including operation start/stop switches, indication lamp as well as frequency inverter set 1.00
Sheet steel clad powder coated (16 SWG-1.6MM), IEC standard
2.9 CHILLER
CHILLER Cabinet (CH_S1, CH_S2, CH_S3)
Enclosure IP54, 415/230 V, 85KA, 50HZ,(Include: MCCB, Magnetic cotactor, Relay,Overload,
2.9.1 set 3.00
timer, wiring, Cable gland, etc) Sheet steel clad powder coated (16 SWG-1.6mm) ,IEC Standard with
type tested certificate.
Ref: A350-7-EA-2-0001, A350-7-EA-1-0003, A350-7-EA-2-0004, A350-7-EA-7-0001,A350-7-EA-5-
0006-0008.
Include:
1- MCCB 3P x 1250A, with adjustable thermal overload and adjustable magnetic short circuit
releases -1 each
2- MCCB 3P x 220A, with adjustable thermal overload and adjustable magnetic short circuit releases
-6 each
3- Busbar copper 400 V, 50 HZ, 3~PH , 1250A,85 KA, hard drawn copper busbars-1 each
4- Measuring devices cell (A&V) -1 each
2.9.2 Chiller accessories
Triphase plugs ( Sockets ) to be installed under silo
set 18.00
250A, 3P+PEN, 400V AC, IP55 Waterproof, Atex
Triphase Plugs ( Sockets ) to be installed outside Loading House
set 1.00
32A, 3P+PEN , 400V AC, IP66 Waterproof, Atex
Ref: A350-7-EA-6
- CCTV with required accessories, 20set camera, 1set desktop, Complete Package
4.2.2 Equipment outside control room
- Local Romote stations (remote I/O panels), IP66, 230/24 V, 50HZ - 9 set
Ref: A350-4-EA-3, A350-4-EA-6-0001,A350-4-EA-8-0001,A350-4-EA-6-0002,
Include:
1- No. of I/O signals for remote panel 1 Include 58 Signal +20% SPARE
2- No. of I/O signals for remote panel 2 Include 207 Signal +20% SPARE
3- No. of I/O signals for remote panel 3 Include 206 Signal +20% SPARE
4- No. of I/O signals for remote panel 4 Include 142 Signal +20% SPARE
5- No. of I/O signals for remote panel 5 Include 131 Signal +20% SPARE
6- No. of I/O signals for remote panel 6 Include 108 Signal +20% SPARE
7- No. of I/O signals for remote panel 7 Include 134 Signal +20% SPARE
8- No. of I/O signals for remote panel 8 Include 131 Signal +20% SPARE
9- No. of I/O signals for remote panel 9 Include 106 Signal +20% SPARE
Other Accessories
- High Level Switch, LSH, Sensor Specification Ref: LS001 - 4 Set
- High Level Switch, LSH, Sensor Specification Ref: LS002 - 18 Set
- High Level Switch, LSH, Sensor Specification Ref: LS003 - 30 Set
- Medium Level Switch, LSM, Sensor Specification Ref: LS001 - 2 set
- Low Level Switch, LSL, Sensor Specification Ref: LS001 - 22 Set
- Low Level Switch, LSL, Sensor Specification Ref: LS004 - 30 Set
- Sub-jucntion Box, IP66, Water Proof, include all the terminal, cable glamd and the support, size
220X17 mm - 220 set
- Sub-jucntion Box, IP66, Water Proof, include all the terminal, cable glamd and the support, size
150X110 mm - 400 set
- Local Control Box, IP66, Sheet steel clad powder coated (16 SWG), - 235 set
Each box Include:
Equipment System
+ Manual chain block with manual trolley Galvanized 3 ton, 10m lifting height set 5.00
+ Manual chain block with manual trolley Galvanized 5 ton, 10m lifting height set 2.00
- Monorail Hoist
Capacity: 4 tons
1.7.20 Lifting height: 65m Galvanized set 1.00
Monorail: 6m
Control: Radio remote 100m
Sub-Total material
Labor cost for installation lot 1.00
Fire-Fighting System
Unit Rates Amounts
Item No Description of Work Unit Quantity
In Figure In Word In Figure In Word
A350-7-UT-4-0002-0018
1 Auto-fire Alarm System
1.1 Fire bell each 40.00
1.2 Fire button each 40.00
1.3 Smoke sensor each 280.00
1.4 Temperature sensor each 150.00
1.5 Exit lamp each 73.00
1.6 Emergency lamp each 78.00
1.7 Cable 2c x1,5 mm m 6,217.00
1.8 Cable 4c x1,5 mm m 5,936.00
1.9 PVC pipe D20 m 1,850.00
Sub-Total 1
2 Water Fire-Fighting system
2.1 Diesel Fire - Pump set 1.00
Include:
- Diezen Fire - Pump (Q=65m3/h; H=110m) - 02 each
- Jockey Fire - Pump (Q=7m3/h; H=110m) - 01 set
- Gate Valve - Suction Line - 02 No
- Non Return Valve - 02 No
- Gate Valve - Discharge Header - 01 No
- Gate Valve - Jockey - 01 No
- Diesel Controller - 01 set
- Jockey Controller - 01 set
- Non Return Valve - Jockey Pump - 01 No
- Pressure Sensing Line - 03 Line
- Ball Valve - 03 No
- Drain Pipe - 02 Line
- Soft hose coupling ∅100_ 01 set
- Y-Strainer_ 02 sets
2.2 Fire control panel 18 zones set 1.00
2.3 Fire - Hydrant 2 head ∅65 each 1.00
Communication System
Masonry pucca platform (at least 100 sq. ft size ) providing brick soling and net
1.3 cement finishing for keeping fuel and lubricants for machineries for prevention of No 2
spillage and leakage of the polluting materials in the soil and open places
Worksite sanitation facilities: 6 nos. of the toilets including separate toilet for
2.2 women (at least 5ft x 8ft size, preferably CC floor with tin-shed roofing) at two Nos. 6
separate corners of the boundary wall as per direction of EC
Sub-Total 2
3 Environmental and Social Enhancement Measures
Cautionary signs-10 nos. (Plane sheet size 2 ft * 3 ft, Background color of the
plane sheet- White, Font-aerial & bold with black color text, Font size at least 50
3.1 Nos. 10
or bigger size to make it visible from at least 200m distance) as per direction of
EC
Traffic control measures and accident control (safety sign board, traffic
regulation equipment if any, placement of well dressed flagmans etc. as and
3.2 when required) for the project activities as per requirement during construction LS −
period as per direction of EC
Provision of the site and campsite cleanliness, fogging (during dengue season-
once in every week and rest months once in a month) by engaging City Corp.
3.3 people, use of bleaching powder and replacing the curing water at each three days LS −
interval to minimize dengue fever for the workers, staffs to be involved in the
construction activities
Maintenance and cleaning of the equipment, machinery and vehicles to be
3.4 used in the construction activities as per direction of EC LS −
Arrangement of stockpile sites through proper fencing around for storing
construction materials (sand, stone, re-bar/rod, bricks, shuttering materials etc.)
3.5 workforce camp in a suitable and separate place with proper entry restriction and LS −
time to time rehabilitation of the stockpile site as per direction of EC
Awareness building program for the contractor and the workers on overall
Environmental and Social Management including minimization of the labor
3.9 influx impacts and efficient workforce management and efficient use of PPE and Nos. 3
natural resources like water, electricity, gas, diesel etc. (100 person-day)
Awareness building program for the host community by engaging local NGO
for minimizing risks associated with labor influx in host community (conducting
3.10 workshops, distribution of leaflet, poster, campaign etc.) (100 Nos. 3
person-day)
Provision of the contraceptive barrier methods (condoms) for the workers and
3.11 site staffs to be involved in the project activities as per requirement LS −
Provision of the vaccination program (Hepatitis A and B, rabies, tetanus,
diphtheria, polio, typhoid, influenza, pneumonia etc.) for the workers and site
staffs to be involved in the project activities by engaging local NGO for
3.12 LS −
minimizing risks associated with vector borne, water borne and infectious
diseases as per requirement
Noise and vibration level measurement. It can be measured from the recognized
environmental survey company/ public institute/ university four times Per
4.2 4
considering two years work duration (twice in each year) during construction measurement
phase for overall construction activities.
Drinking water quality parameters -ground water/supply water to be used as
drinking water (pH, Color-true or apparent, turbidity, total hardness, Cl, TDS,
Mn, As, Fe, TC, FC) measurement. It can be measured from the recognized Per
4.3 environmental survey company/ public institute/ university four times measurement 4
considering two years work duration (twice in each year) during construction
phase.
Sub-Total 4
COVID-19 Occupational Health and Safety Response and Preventive
5
Measures
Personal protective equipment- Three layers washable cloth/fabric face masks
(1000 nos.), disposable medical face masks (1000 nos.), face shield (100 nos.),
5.1 LS −
disposable gloves (latex/nitrile) (500 pairs), washable appron (100 nos.) during
entire construction period
Hand washing and shoes disinfecting facilities- providing adequate hand
sanitizer, soap, paper towels, tissues and installation and operation of hand
5.2 washing station (3 nos.) and shoe disinfecting station (2 nos.), foot pedal LS −
dispenser (1 no.) during construction period
Sub-Total 5
6 Social Safeguard (Social Management Plan - SMP)
6.1 Awareness raising program on Grievance Redress Mechanism: Awareness
raising program on Grievance Redress Mechanism for stakeholders and workers
at the worksite (100 participants in a day) and instruction to GRC members for No 3
dealing with GRM
6.2 Implementation of GRM for workers: Implementation cost of GRC decisions
which is not covered by the Insurance (Maximum Tk 15,000/Case) No. 10