Series TY-B – 2.8, 5.6, and 8.0 K-factor


Upright, Pendent, and Recessed Pendent Sprinklers
Standard Response, Standard Coverage
General it is recommended that the end-user be
consulted about the suitability of these
Description coatings for any given corrosive envi-
ronment. The effects of ambient tem-
The TYCO Series TY-B 2.8, 5.6, perature, concentration of chemicals,
and 8.0 K-factor, Upright, Pendent, and gas/chemical velocity, should be
and Recessed Pendent Sprin- considered as a minimum, along with
klers described herein are standard the corrosive nature of the chemical to
response, standard coverage, decora- which the sprinklers will be exposed.
tive 5 mm glass bulb-type spray sprin- An intermediate level version of the
klers. They are designed for use in light, Series TY-B Pendent Sprinkler can be
ordinary, or extra-hazard commercial obtained by utilizing the Series TY-B
occupancies such as banks, hotels, Pendent Sprinkler in combination with
shopping malls, factories, refineries, the Model S2 Shield.
and chemical plants.
The TY-B Recessed Pendent Sprinkler, NOTICE
where applicable, is intended for use in The Series TY-B 2.8, 5.6, and 8.0 K-fac-
areas with a finished ceiling. It uses a tor, Upright, Pendent, and Recessed
two-piece Style 10 (1/2 in. NPT) or Style Pendent Sprinklers described herein
40 (3/4 in. NPT) Recessed Escutcheon. must be installed and maintained in
The Recessed Escutcheon provides compliance with this document, as well
1/2 in. (12,7 mm) of recessed adjust- as with the applicable standards of the
ment or up to 3/4 in. (19,1 mm) of total National Fire Protection Association
adjustment from the flush pendent (NFPA), in addition to the standards of
position. The adjustment provided by
the Recessed Escutcheon reduces the
any other authorities having jurisdiction.
Failure to do so may impair the perfor-
Technical
accuracy to which the fixed pipe drops
to the sprinklers must be cut.
mance of these devices. Data
The owner is responsible for maintain-
Corrosion-resistant coatings, where Approvals
ing their fire protection system and UL and C-UL Listed
applicable, are utilized to extend devices in proper operating condi- FM, LPCB, VdS, and NYC Approved
the life of copper alloy sprinklers tion. Contract the installing contrac-
beyond what would be obtained tor or product manufacturer with any See Tables A, B and C for complete approval
when exposed to corrosive atmo- information, including corrosion-resistant
questions. status.
spheres. Although corrosion-resistant
coated sprinklers have passed the NFPA 13 prohibits installation of 1/2 in. Maximum Working Pressure
standard corrosion tests of the appli- NPT sprinklers with K-factors greater See Table D
cable approval agencies, the testing than 5.6 in new construction. They are
intended for retrofit in existing sprinkler Discharge Coefficient
is not representative of all possible K=2.8 gpm/psi½ (40,3 Lpm/bar½)
corrosive atmospheres. Consequently, systems only.
K=5.6 gpm/psi½ (80,6 Lpm/bar½)

IMPORTANT
Sprinkler K=8.0 gpm/psi½ (115,2 Lpm/bar½)
Temperature Ratings
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
Identification See Tables A, B and C

regulatory and health information. Numbers (SIN) Finishes


Sprinkler: See Table E
Always refer to Technical Data TY1151 . . . . Upright 2.8K, 1/2 in. NPT Recessed Escutcheon: Signal or Pure White,
Sheet TFP700 for the “INSTALLER Grey Aluminum, Jet Black, Chrome Plated,
TY1251 . . Pendent 2.8K, 1/2 in. NPT or Natural Brass
WARNING” that provides cautions
with respect to handling and instal- TY3151 . . . Upright 5.6K, 1/2 in. NPT
TY3251 . . Pendent 5.6K, 1/2 in. NPT Physical Characteristics
lation of sprinkler systems and com- Frame �������������������������������������������������������Bronze
ponents. Improper handling and TY4151 . . . . Upright 8.0K, 3/4 in. NPT Button ������������������������������������������� Brass/Copper
installation can permanently damage TY4251 . . Pendent 8.0K, 3/4 in. NPT Sealing Assembly. . Beryllium Nickel w/TEFLON
a sprinkler system or its compo- Bulb ������������������������������������������������������������� Glass
TY4851 . . . Upright 8.0K, 1/2 in. NPT Compression Screw ���������������������������������Bronze
nents and cause the sprinkler to fail TY4951 . . Pendent 8.0K, 1/2 in. NPT Deflector �������������������������������������������������� Copper
to operate in a fire situation or cause Bushing (K=2.8) ���������������������������������������Bronze
it to operate prematurely.

Page 1 of 10 MAY 2020 TFP151


TFP151
Page 2 of 10

CEILING PLATE 1 - Frame 5 - Compression


SEATING SURFACE 2 - Button Screw
7 3 - Sealing 6 - Deflector *
Assembly 7 - Bushing
1 4 - Bulb
7/16" 2-1/4"
(11,1 mm) 3
(57,2 mm)
NOMINAL
MAKE-IN 2 * Temperature rating is
indicated on Deflector.
2-3/16" 1-9/16" 4
(55,6 mm) (39,7 mm)
5 ** Pipe thread connections
per ISO 7-1 can be
6* provided on special
1/2" NPT** WRENCH request.
FLATS
UPRIGHT PENDENT CROSS SECTION
FIGURE 1
SERIES TY-B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS
2.8 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE

* Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression


is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw
Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector *
SURFACE
1

7/16" 3
(11,1 mm)
NOMINAL 2-3/16" 2
MAKE-IN (55,6 mm)
4
2-3/16" 1-1/2"
(55,6 mm) (38,1 mm) 5

6*
1/2" NPT** WRENCH STYLE 10 2-7/8" (73,0 mm) DIA.
FLATS RECESSED
UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION
ALL FINISHES EXCEPT POLY-STAINLESS
WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression * Temperature
FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated
SURFACE 4 - Bulb 6 - Deflector * on Deflector.
1

7/16" 3
(11,1 mm)
NOMINAL 2-3/16" 2
MAKE-IN (55,6 mm)
4
2-3/16" 1-1/2"
(55,6 mm) (38,1 mm) 5

6*
STYLE 10 2-7/8" (73,0 mm) DIA.
RECESSED
UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION
POLY-STAINLESS FINISH ONLY
FIGURE 2
SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS
5.6 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE
TFP151
Page 3 of 10

* Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression


is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw
Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector *
SURFACE
1

1/2" 3
(12,7 mm)
NOMINAL 2-5/16" 2
MAKE-IN (58,7 mm)
2-1/4" 1-9/16" 4
(57,2 mm) (39,7 mm)
5

6*
3/4" NPT** WRENCH STYLE 40 2-7/8" (73,0 mm) DIA.
FLATS RECESSED
UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION
ALL FINISHES EXCEPT POLY-STAINLESS
WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression * Temperature
FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated
SURFACE 4 - Bulb 6 - Deflector * on Deflector.
1

1/2" 3
(12,7 mm)
NOMINAL 2
MAKE-IN 2-5/16"
(58,7 mm)
4
2-1/4" 1-9/16"
(57,2 mm) (39,7 mm) 5

6*
STYLE 40 2-7/8" (73,0 mm) DIA.
RECESSED
UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION
POLY-STAINLESS FINISH ONLY
FIGURE 3
SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS
8.0 K-FACTOR, 3/4 IN. NPT, STANDARD RESPONSE

CEILING PLATE 1 - Frame 5 - Compression


SEATING SURFACE 2 - Button Screw
1 3 - Sealing 6 - Deflector *
Assembly
3 4 - Bulb
7/16" 2-1/4"
(11,1 mm) (57,2 mm)
NOMINAL 2
MAKE-IN * Temperature rating is
4 indicated on Deflector.
2-3/16" 1-9/16"
(55,6 mm) (39,7 mm)
5 ** Pipe thread connections
per ISO 7-1 can be
6* provided on special
1/2" NPT** WRENCH request.
FLATS
UPRIGHT PENDENT CROSS SECTION
FIGURE 4
SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS
8.0 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE
TFP151
Page 4 of 10

2-7/8" DIA. 2-7/8" DIA.


(73,0 mm) 3/4" (19,1 mm) (73,0 mm) 3/4" (19,1 mm)
5/8±1/4" 5/8±1/4"
(15,9±6,4 mm) 1/4" (6,4 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm)
2-1/4" DIA.
(57,2 mm) (57,2 mm)
FACE OF MOUNTING FACE OF MOUNTING
SPRINKLER PLATE SPRINKLER PLATE
FITTING FITTING
1/8" 1/8"
(3,2 mm) (3,2 mm)

MOUNTING MOUNTING
SURFACE SURFACE

SERIES 1-1/4" (31,8 mm) CLOSURE SERIES 1-5/16" (33,3 mm)


CLOSURE
TY-B 3/4" (19,1 mm) TY-B 13/16" (20,6 mm)
FIGURE 5 FIGURE 6
SERIES TY-B RECESSED PENDENT SPRINKLER SERIES TY-B RECESSED PENDENT SPRINKLER
ASSEMBLY WITH TWO-PIECE 3/4 IN. TOTAL ASSEMBLY WITH TWO-PIECE 3/4 IN. TOTAL
ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 IN. NPT 8.0 K-FACTOR, 3/4 IN. NPT

WRENCH
RECESS

WRENCH RECESS
(END "A" USED FOR
1/2" NPT MODELS)

WRENCH RECESS PUSH WRENCH


(END "B" USED FOR IN TO ENSURE
3/4" NPT MODELS) ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 7 FIGURE 8
W-TYPE 6 W-TYPE 7 RECESSED
SPRINKLER WRENCH SPRINKLER WRENCH

Poly-Stainless
Physical Characteristics Design Installation
Criteria
Frame �������������������������������������������������������Bronze
Button. . . . . . . . . . . . . . . . . L316 Stainless Steel* The TYCO Series TY-B 2.8, 5.6, and
Bulb ������������������������������������������������������������� Glass 8.0 K-factor, Upright, Pendent, and
Compression Screw ����������L316 Stainless Steel* The TYCO Series TY-B 2.8, 5.6, and Recessed Pendent Sprinklers must
Deflector ������������������������������������� Copper/Bronze 8.0 K-factor, Upright, Pendent, and be installed in accordance with this
Sealing Assembly. . Gold Plated Beryllium Nickel
w/TEFLON
Recessed Pendent Sprinklers are section.
*Type L316 stainless steel (UNS 31603) per ASTM intended for fire protection systems
General Instructions
A479/479M or BS EN 1008 WN1.4404. designed in accordance with the stan-
Do not install any bulb type sprinkler
Operation dard installation rules recognized by
the applicable Listing or Approval
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
agency, such as UL Listing based on
The glass bulb contains a fluid which kler held horizontally, a small air bubble
the requirements of NFPA 13 and FM
expands when exposed to heat. When should be present. The diameter of the
Approval based on the requirements
the rated temperature is reached, the air bubble is approximately 1/16 in.
of the FM Global Loss Prevention Data
fluid expands sufficiently to shatter the (1,6 mm) for the 135°F (57°C) to
Sheets. Use only the Style 10 or 40
glass bulb, allowing the sprinkler to 3/32 in. (2,4 mm) for the 360°F (182°C)
Recessed Escutcheon, as applicable,
activate and water to flow. temperature ratings.
for recessed pendent installations.
A leak-tight 1/2 in. NPT sprinkler
joint should be obtained by apply-
ing a minimum-to-maximum torque of
7 to 14 lb-ft (9,5 to 19,0 N·m). Obtain
a leak-tight 3/4 in. NPT sprinkler joint
by applying a minimum to maximum
TFP151
Page 5 of 10

Sprinkler Finish 8
Bulb
K-Factor Sprinkler Temperature Liquid Wax-Over-
Type Rating Natural Chrome Polyesterc Poly-Stainlessc Lead Wax
Color Lead
Brass Plated Coated Coated Coated
135°F (57°C) Orange
Upright 155°F (68°C) Red
(TY1151)
2.8 175°F (79°C) Yellow 1, 2, 3
and
1/2 in. N/A N/Ad
Pendent 200°F (93°C) Green
NPT (TY1251)
Figure 1 286°F (141°C) Blue
360°F (182°C) Mauve 1, 2
NOTES
1. Listed by Underwriters Laboratories, Inc. (UL).
2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL).
3. Approved by FM Global (FM Approvals).
4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03).
5. Approved by the City of New York under MEA 354-01-E.
6. VdS Approved. (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377)
7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05)
8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as
Corrosion-Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as
Corrosion-Resistant Sprinklers.
a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable
b. 150°F (66°C) maximum ceiling temperature
c. Frame and deflector only
d. Not Applicable (N/A)

TABLE A
SERIES TY-B 2.8 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS
LABORATORY LISTINGS AND APPROVALS
TFP151
Page 6 of 10

Sprinkler Finish 8
Bulb
K-Factor Sprinkler Temperature Liquid Wax-Over-
Type Rating Natural Chrome Polyesterc Poly-Stainlessc Lead Wax
Color Lead
Brass Plated Coated Coated Coated
135°F (57°C) Orange
155°F (68°C) Red
Upright 1, 2, 3, 5 1, 2, 3, 5
(TY3151) 175°F (79°C) Yellow
1, 2, 3, 5, 6 1, 2 1, 2, 3, 5
Figure 2 200°F (93°C) Green
286°F (141°C) Blue 1b, 2b,3b, 5b 1b, 2b, 3b, 5b
360°F (182°C) Mauve N/A
135°F (57°C) Orange
155°F (68°C) Red
5.6 Pendent 1, 2, 3, 5 1, 2, 3, 5
175°F (79°C) Yellow
1/2 in. (TY3251) 1, 2, 3, 4, 5, 6, 7 1, 2 1, 2, 3, 5
NPT 200°F (93°C) Green
Figure 2
286°F (141°C) Blue 1b, 2b, 3b, 5b 1b, 2b, 3b, 5b
360°F (182°C) Mauve N/A
135°F (57°C) Orange
Recessed 155°F (68°C) Red
Pendent 1, 2, 3, 4, 5
(TY3251)a 175°F (79°C) Yellow 1, 2 N/A
Figure 5 200°F (93°C) Green
286°F (141°C) Blue 1, 2
NOTES
1. Listed by Underwriters Laboratories, Inc. (UL).
2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL).
3. Approved by FM Global (FM Approvals).
4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03).
5. Approved by the City of New York under MEA 354-01-E.
6. VdS Approved. (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377)
7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05)
8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as
Corrosion-Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as
Corrosion-Resistant Sprinklers.
a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable
b. 150°F (66°C) maximum ceiling temperature
c. Frame and deflector only
d. Not Applicable (N/A)

TABLE B
SERIES TY-B 5.6 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS
LABORATORY LISTINGS AND APPROVALS
TFP151
Page 7 of 10

Sprinkler Finish 8
Bulb
K-Factor Sprinkler Temperature Liquid Wax-Over-
Type Rating Natural Chrome Polyesterc Poly-Stainlessc Lead Wax
Color Lead
Brass Plated Coated Coated Coated
135°F (57°C) Orange
Upright 155°F (68°C) Red
(TY4151) 1, 2, 3, 5 1, 2, 5
and 175°F (79°C) Yellow
1, 2, 3, 4, 5, 6, 7 1, 2 1, 2, 5
Pendent 200°F (93°C) Green
(TY4251)
Figure 3 286°F (141°C) Blue 1b, 2b, 3b, 5b 1b, 2b, 5b
8.0
3/4 in. 360°F (182°C) Mauve N/A
NPT
135°F (57°C) Orange
Recessed 155°F (68°C) Red
Pendent 1, 2, 3, 4, 5
(TY4251)a 175°F (79°C) Yellow 1, 2 N/A
Figure 6 200°F (93°C) Green
286°F (141°C) Blue 1, 2
135°F (57°C) Orange
Upright 155°F (68°C) Red
(TY4851)
8.0 and 175°F (79°C) Yellow
1/2 in. 1, 2, 3, 4, 5, 6 N/A N/A
Pendent 200°F (93°C) Green
NPT (TY4951)
Figure 4 286°F (141°C) Blue
360°F (182°C) Mauve
NOTES
1. Listed by Underwriters Laboratories, Inc. (UL).
2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL).
3. Approved by FM Global (FM Approvals).
4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03).
5. Approved by the City of New York under MEA 354-01-E.
6. VdS Approved. (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377)
7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05)
8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as
Corrosion-Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as
Corrosion-Resistant Sprinklers.
a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable
b. 150°F (66°C) maximum ceiling temperature
c. Frame and deflector only
d. Not Applicable (N/A)

TABLE C
SERIES TY-B 8.0 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS
LABORATORY LISTINGS AND APPROVALS
TFP151
Page 8 of 10

Sprinkler Finish
K-Factor Type
Natural Chrome Lead Wax Wax-Over-Lead
Polyester1
Brass Plated Coated Coated Coated

2.8 Upright (TY1151)


1/2 in. and 175 psi (12,1 bar) N/A3
NPT Pendent (TY1251)

Upright (TY3151)
and
5.6 Pendent (TY3251) 250 psi (17,2 bar)2
1/2 in. or
NPT 175 psi (12,1 bar)
Recessed Pendent
(TY3251)

Upright (TY4151)
and 175 psi (12,1 bar)
8.0 Pendent (TY4251)
3/4 in.
NPT
Recessed Pendent 175 psi (12,1 bar) N/A
(TY4251)

8.0 Upright (TY4851)


1/2 in. and 175 psi (12,1 bar)
NPT Pendent (TY4951)

NOTES
1. Frame and deflector only
2. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL), the Listing by Underwriters Laboratories, Inc. for use in
Canada (C-UL), and the Approval by the City of New York.
3. Not Applicable (N/A)
TABLE D
SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS
MAXIMUM WORKING PRESSURE

torque of 10 to 20 lb-ft (13,4 to Step 3. Tighten the sprinkler into the After Installation
26,8 N·m). Higher levels of torque may sprinkler fitting using only the W-Type After installation, complete the
distort the sprinkler inlet and cause 6 Sprinkler Wrench, see Figure 7. following:
leakage or impairment of the sprinkler. For wax-coated sprinklers, use an • Inspect the sprinkler wrench flats
8 or 10 in. adjustable wrench. With and frame arms and retouch (repair)
Do not attempt to compensate for
reference to Figure 1 to 4, apply the the wax coating whenever the coat-
insufficient adjustment in the escutch-
W-Type 6 Recessed Sprinkler Wrench ing has been damaged and bare
eon plate by under- or over-tightening
or an adjustable wrench, as applicable, metal is exposed.
the sprinkler. Readjust the position of
to the sprinkler wrench flats.
the sprinkler fitting to suit. • Retouch the wax coating on the
Wax Coated Sprinklers wrench flats by gently applying a
Series TY-B Upright and Pendent
When installing wax-coated sprinklers heated 1/8 in. diameter steel rod
Sprinklers Installation with an adjustable wrench, take care to to the damaged areas of wax, to
The Series TY-B Upright and Pendent prevent damage to the wax coating on smooth it back over areas where
Sprinklers must be installed in accor- the sprinkler wrench flats or frame arms bare metal is exposed.
dance with the following instructions: and, consequently, exposure of bare
Step 1. Install pendent sprinklers in the metal to the corrosive environment: NOTICE
pendent position. Install upright sprin- Only retouching of the wax coating
• Open the jaws of the wrench suffi-
klers in the upright position. applied to the wrench flats and frame
ciently wide to pass over the wrench
Step 2. With pipe thread sealant flats without damaging the wax arms is permitted, and the retouching
applied to the pipe threads, hand- coating. is to be performed only at the time of
tighten the sprinkler into the sprinkler • Before wrench tightening the sprin- the initial sprinkler installation.
fitting. kler, adjust the jaws of the wrench The steel rod should be heated only to
to contact only the sprinkler wrench the point it can begin to melt the wax,
flats. and appropriate precautions need to be
• After wrench tightening the sprin- taken when handling the heated rod in
kler, loosen the wrench jaws before order to prevent the installer from being
removing the wrench. burned.
TFP151
Page 9 of 10

Series TY-B Recessed Pendent


Sprinklers Care and Automatic sprinklers must never be
painted, plated, coated, or other-
The Series TY-B Recessed Pendent
Sprinklers must be installed in accor- Maintenance wise altered after leaving the factory.
Modified sprinklers must be replaced.
dance with the following instructions: The TYCO Series TY-B 2.8, 5.6, and Sprinklers that have been exposed to
8.0 K-factor, Upright, Pendent, and corrosive products of combustion, but
Step 1. After installing the Style 10
Recessed Pendent Sprinklers must be have not operated, should be replaced
or 40 Mounting Plate, as applicable,
maintained and serviced in accordance if they cannot be completely cleaned
over the sprinkler threads and with
with this section. by wiping the sprinkler with a cloth or
pipe thread sealant applied to the pipe
by brushing it with a soft bristle brush.
threads, hand-tighten the sprinkler into Before closing a fire protection system
the sprinkler fitting. main control valve for maintenance Care must be exercised to avoid
work on the fire protection system damage to the sprinklers before,
Step 2. Tighten the sprinkler into the
that it controls, obtain permission to during, and after installation. Sprin-
sprinkler fitting using only the W-Type 7
shut down the affected fire protection klers damaged by dropping, strik-
Recessed Sprinkler Wrench, see Figure
system from the proper authorities ing, wrench twist/slippage, or the like,
8. With reference to Figure 3 or 4, apply
and notify all personnel who may be must be replaced. Replace any sprin-
the W-Type 7 Recessed Sprinkler
affected by this action. kler that has a cracked bulb or that has
wrench to the sprinkler wrench flats.
lost liquid from its bulb. See the Instal-
Step 3. After the ceiling is installed or The owner must assure that the sprin- lation Section.
the finish coat is applied, slide on the klers are not used for hanging any
Style 10 or 40 Closure over the Series objects and that the sprinklers are only The owner is responsible for the
TY-B Recessed Pendent Sprinkler cleaned by means of gently dusting inspection, testing, and maintenance of
and push the Closure over the Mount- with a feather duster; otherwise, non- their fire protection system and devices
ing Plate until its flange contacts the operation in the event of a fire or inad- in compliance with this document, as
ceiling. vertent operation may result. well as with the applicable standards
of the National Fire Protection Associa-
Absence of an escutcheon, which is tion, such as, NFPA 25, in addition to
used to cover a clearance, may delay the standards of any other authorities
the time to sprinkler operation in a fire having jurisdiction. Contact the install-
situation. ing contractor or product manufacturer
Sprinklers which are found to be with any questions.
leaking or exhibiting visible signs of Automatic sprinkler are recommended
corrosion must be replaced. to be inspected, tested, and maintained
by a qualified Inspection Service in
accordance with local requirements
and/or national codes.
TFP151
Page 10 of 10

P/N 57 – XXX – X – XXX

SPRINKLER TEMPERATURE
SIN RATING
FINISH

530 2.8K UPRIGHT (1/2 in. NPT) TY1151 1 NATURAL BRASS 135 135°F (57°C)

531 2.8K PENDENT (1/2 in. NPT) TY1251 POLY-STAINLESS GREY 155 155°F (68°C)
2 ALUMINUM (RAL9007)1
POLYESTER
570 5.6K UPRIGHT (1/2 in. NPT) TY3151 175 175°F (79°C)
PURE WHITE (RAL9010)2
3
POLYESTER
571 5.6K PENDENT (1/2 in. NPT) TY3251 200 200°F (93°C)
SIGNAL WHITE (RAL9003)
4
POLYESTER 286 286°F (141°C)
590 8.0K UPRIGHT (3/4 in. NPT) TY4151
JET BLACK (RAL9005)3
5
POLYESTER 360 360°F (182°C)
591 8.0K PENDENT (3/4 in. NPT) TY4251
WAX COATED
6
286°F (141°C) MAX 000 OPEN4
560 8.0K UPRIGHT (1/2 in. NPT) TY4851
7 LEAD COATED
561 8.0K PENDENT (1/2 in. NPT) TY4951
WAX-OVER-LEAD
8
286°F (141°C) MAX

9 CHROME PLATED

NOTES
1. Only available on TY3151, TY3251, TY4151, and TY4251.
2. Eastern Hemisphere sales only.
3. Available in only 8.0K, 155°F (68°C) or 200°F (93°C); requires lead time to manufacture.
4. Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems (“OPEN” indicates sprinkler assembly without glass bulb, button, and sealing assembly).

TABLE E
SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS
PART NUMBER SELECTION

Limited Sprinkler Wrenches


Specify: W-Type 6 Sprinkler Wrench,
Warranty P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
For warranty terms and conditions, visit P/N 56-850-4-001
www.tyco-fire.com.
Wax Sticks (for retouching wrench-

Ordering
damaged wax coating)
Specify: (specify color, below) Color-

Procedure
coded Wax Sticks for retouching
(specify temperature rating) tempera-
ture-rated Series TY-B Sprinklers, P/N
Contact your local distributor for avail- (specify)
ability. When placing an order, indicate
the full product name and Part Number Black for 135°F (57°C) . . . . . . P/N 56-065-1-135
Red for 155°F (68°C) . . . . . . . . P/N 56-065-1-155
(P/N). Yellow for 175°F (79°C) . . . . . . P/N 56-065-1-175
Sprinkler Assemblies with Blue for 200°F (93°C)
and 286°F (141°C) . . . . . . . . . . P/N 56-065-1-
NPT Thread Connections 286
Specify: Series TY-B (specify SIN),
(specify K-factor), (specify Upright Note: Each wax stick is suitable for
or Pendent) Sprinkler with (specify) retouching up to 25 sprinklers.
temperature rating, (specify) finish or The wax used for 286°F (141°C) sprinklers
coating, P/N (See Table E) is the same as for 200°F (93°C) sprinklers.
Recessed Escutcheon Therefore, the 286°F (141°C) sprinkler
Specify: Style (10 or 40) Recessed is limited to the same maximum ceiling
Escutcheon with (specify*) finish, P/N temperature as the 200°F (93°C) sprinkler
(specify*) which is 150°F (66°C).
* Refer to Technical Data Sheet TFP770

1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700


© 2020 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.

NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association;
TEFLON is a registered trademark of DuPont