VALVES VENTS, EXHAUSTS AND DRAINS SPECIALITY ITEMS LINE DESIGNATIONS INSULATION AND TRACING TYPE SERVICE CODES

LINE DESIGNATIONS INSULATION AND TRACING TYPE SERVICE CODES NOTES:


THIS DRAWING IS FOR ITEMS AND SYMBOLS SHOWN ON P&IDS ONLY.
GATE VALVE INSULATION TYPE CODE SERVICE 1. WHERE A RING SPACER IS INDICATED IT SHALL COME WITH AN
V NORMALLY CLOSED VENT VALVE, PLUGGED PROCESS PRIMARY LINES A AIR EQUIVALENT BLIND. AND LIKEWISE SPACER TO BE PROVIDED IN
EXHAUST HEAD
XXX °F HC
ACCORDANCE WITH THE PIPING SPECIFICATION.
GATE VALVE NORMALLY CLOSED AD AMINE DRAIN
PROCESS SECONDARY / 2. 'X' CORRESPONDS TO SAMPLE CONNECTION TYPE AND TO BE
REMOVABLE SPOOL ET AH ACID HYDROCARBON SHOWN AS PER LEGEND SHEET T80-A-CA-033800-007 & 008.
RS UTILITY LINES TRACING TYPE EQUIPMENT
GATE VALVE, DOUBLE DISC D NORMALLY CLOSED DRAIN VALVE, PLUGGED INSULATION THICKNESS AS ACID SEWER C
FLEXIBLE COUPLING HEAT TRACING (BY DETAILED DESIGN) AG ACID GAS
GATE VALVE, 3 -WAY NORMALLY CLOSED VENT VALVE, FLANGED 3" BBD BOILER BLOWDOWN

PP
V

3"
JACKETED PIPING PP BD BLOWDOWN
GATE VALVE, 3-WAY, CLOSED PULSATION DAMPER BFW BOILER FEED WATER
INSULATION TYPE
D NORMALLY CLOSED DRAIN VALVE, FLANGED UNDERGROUND PIPING BS BIO-SLUDGE
GATE VALVE, ANGLE CBD COLD BLOWDOWN
SC-X SAMPLE CONNECTION
SC STEAM CONTROL TRACED C CHEMICAL
NOTE 2
GLOBE VALVE CATCH BASIN DRAIN PACKAGE LINE ET ELECTRIC TRACED CA CAUSTIC
SG SIGHT GLASS ST STEAM TRACED CAS CAUSTIC SEWER
GLOBE VALVE, NORMALLY CLOSED DRAIN TO PRESSURE SEWER SJ STEAM JACKETED CAT CATALYST C

SP
LINE IDENTIFICATION HT HOT FLUID TRACED CCC
C
COOLED CLEAN CONDENSATE
CHECK VALVE SPECIALITY ITEM TAG HJ HOT FLUID JACKETED CDH CLOSED DRAIN HYDROCARBON C
FITTINGS PIPE SIZE CT CHILLED FLUID TRACED CHR CHILLED WATER RETURN
CHECK VALVE, NON-SLAM FLUID CODE CJ CHILLED FLUID JACKETED CHS CHILLED WATER SUPPLY
TEMPORARY STRAINER SEQUENCE NUMBER AC ACOUSTIC CONTROL INSULATION CI CORROSION INHIBITOR
PLUG VALVE CONCENTRIC REDUCER PIPING MATERIAL CLASS FP FIRE PROTECTION INSULATION CS CHEMICAL SEWER
DRAWING PREVIOUSLY ISSUED AS
3"-P-XXXX-XXXXX
CC COLD SERVICE INSULATION CW CHILLED WATER
T76-A-PP-250600-001
PLUG VALVE, NORMALLY CLOSED ECCENTRIC REDUCER SUMP STRAINER CP CONDENSATION CONTROL INSULATION CWR COOLING WATER RETURN
ADDITIONAL INFORMATION FOR JACKETED PIPING HC HEAT CONSERVATION INSULATION CWS COOLING WATER SUPPLY LEGEND
BALL VALVE CAP Y-STRAINER PS PROCESS STABILITY INSULATION DFW DEAERATOR FEED WATER PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE
PROCESS PIPE SIZE PP PERSONNEL PROTECTION INSULATION DMW DEMINERALIZED WATER AIR FAILURE OPEN VS
-VIBRATION ELEMENT
-VIBRATION SWITCH
AC/AFS -AIR TO CLOSE/AIR
BALL VALVE, NORMALLY CLOSED HOSE CONNECTION T-STRAINER OUTER PIPE SIZE PF PREVENTION FROM FREEZING INSULATION DSW DISTILLED WATER PROCESS LINE
FAILURE STEADY
VT -VIBRATION TRANSMITTER
XL -PILOT LIGHT

2"X3"-SF-XXXX-XXXX
DT DUCT TRIM INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
BUTTERFLY VALVE FLANGES FLAME ARRESTER DW DRINKING WATER INSTRUMENT
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
FAILURE STEADY
ELECTRICAL LINE
E EXHAUST STEAM AOV -AIR OPERATED VALVE DATA LOGGER POINT
F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
ANGLE VALVE NIPPLE SWAGE IN-LINE SILENCER EIA EMERGENCY INSTRUMENT AIR DT -DENSITY TRANSMITTER
L-LEVEL T-TEMP.
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
FGH HIGH PRESSURE FUEL GAS FC - FLOW CONTROLLER
LOCAL PANEL
SPECTACLE MOUNTED INSTR.
ANGLE VALVE, NORMALLY CLOSED INSULATING FLANGES VENT SILENCER SEGMENT BREAKS FGL LOW PRESSURE FUEL GAS PLATE-OPEN
FV
FCV
-FLOW CONTROL VALVE
-FLOW CONTROL VALVE
BOARD MOUNTED
FLO FLUSHING OIL SPECTACLE
(SELF-ACTUATED) INSTRUMENT
FE -FLOW ELEMENT
Y-PATTERN GLOBE VALVE ORIFICE UNION FILTER DRAWING CONNECTIONS FO FUEL OIL PLATE-CLOSED FG -FLOW SIGHT GLASS
R/G
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
Y-PATTERN GLOBE VALVE, FW FIRE WATER FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
NORMALLY CLOSED BIRD SCREEN GG GART GAS FM -FLOW METER
CHECK VALVE
MOTOR STATUS
RING SPACER NOTE 1 PIPING MATERIAL CLASS BREAK OFF DRAWING CONNECTORS (PROCESS CONNECTION) H HYDROGEN FO -RESTRICTION ORIFICE
PILOT LIGHT
PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
HAND CONTROL VALVE
ST STEAM TRAP HCL HYDROCHLORIC ACID BALL VALVE
FR -FLOW RECORDER
ML LOCAL MOUNTED
FT -FLOW TRANSMITTER
C INSTRUMENT
TIGHT SHUT OFF VALVE (ORBIT) HO HYDRAULIC OIL DOUBLE DISC FY -FLOW RELAY
FLAME FRONT SERVICE DESCRIPTION GATE VALVE HIC -HAND INDICATOR CONTROLLER
PS BLIND (CLOSED) NOTE 1 IT IMPULSE STEAM TRAP HPF HIGH PRESSURE FLARE ANGLE VALVE
MOUNTED BEHIND
HS -HAND SWITCH
XXXX CA-XXXXXX-XXX CONNECTION DRAWING NUMBER LOCAL PANEL
TIGHT SHUT OFF STOP HPCF HIGH PRESSURE COLD FLARE LA -LEVEL ALARM

CHECK VALVE (T-PATTERN) TO XXX-X-XXX TO/FROM LOCATION OR EQUIPMENT TAG LV -LEVEL CONTROL VALVE RACK MOUNTED
PRESS.RELIEF VALVE -LEVEL CONTROL VALVE
AT AIR TRAP TRACING BREAK HTF HEAT TRANSFER FLUID LCV
(SELF-ACTUATED)
(OR BACK OF PANEL)

STOP CHECK VALVE OPEN (SPECTACLE BLIND) HWR HOT WATER RETURN LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
C.O. CLEAN OUT HWS HOT WATER SUPPLY VACUUM RELIEF VALVE LI -LEVEL INDICATOR
C LR -LEVEL RECORDER INSTRUMENT
PENSTOCK VALVE IA INSTRUMENT AIR LS -LEVEL SWITCH AIR SUPPLY REQUIRED
XXXX CA-XXXXXX-XXX OPC BETWEEN DIFFERENT PLANT AREAS M MOTOR OPERATED
LT -LEVEL TRANSMITTER
CLOSED (SPECTACLE BLIND) CATCH BASINS INSULATION BREAK LA AGRU LEAN AMINE VALVE
LTD -LEVEL TRANSDUCER
H
HIGH LOW
SPRING LOADED BLOWDOWN VALVE LIN C NITROGEN (LIQUID) C
ML -MOTOR STATUS LIGHT L
P MOV -MOTOR OPERATED VALVE
AG UG PISTON OPERATED
EXCESS FLOW CHECK VALVE END CAP (THREADED) LMEG LEAN MEG VALVE
NA -ANNUNCIATOR TWO PEN RECORDER
PB -PUSHBUTTON
STATIC MIXER
LO LUBE OIL PC -PRESSURE CONTROLLER FF
NEEDLE VALVE (AS SPECIALITY ITEM) CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION

FIRE AND SAFETY SYMBOLS SOUR VAPOUR SERVICE DESCRIPTION


LOX C OXYGEN (LIQUID) C PCV -PRESS. CONTROL VALVE
(SELF ACTUATED)
FIELDBUS INSTRUMENT

SEGMENT BALL VALVE C LPF LOW PRESSURE FLARE BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
AIR RELIEF VALVE - XXXX CA-XXXXXX-XXX CONNECTION DRAWING NUMBER P

CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS


AR
TO/FROM C TO/FROM LOCATION OR EQUIPMENT TAG MD MEG CLOSED DRAIN WITH POSITIONER
SEWAGE TYPE PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
INDICATOR CONTROLLER
MDEA METHYLDETHANOL AMINE
MISCELLANEOUS ABBREVIATIONS SYSTEM, OPERATOR ACCESSIBLE
S
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
VACUUM RELIEF VALVE -
HYDRANT VR MAXIMUM DESIGN PRESSURE & ME METHANOL INDICATOR SWITCH
WATER TYPE OFF DRAWING CONNECTORS (UTILITY CONNECTION) PDT -PRESS. DIFF. TRANSMITTER
(DCS) DISTRIBUTED CONTROL
TEMPERATURE CHANGE VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
CC CORROSION COUPON MEG MONO ETHYLENE GLYCOL CLOSED
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
AIR / VACUUM RELIEF VALVE - PG -PRESSURE GAUGE
AVR MO MIST OIL PI -PRESSURE INDICATOR (DCS) DISTRIBUTED CONTROL
SEWAGE TYPE SYSTEM, OPERATOR INACCESSIBLE
CE CORROSION PROBE MONITOR N NITROGEN (GASEOUS)
PIC -PRESS. INDICATOR CONTROLLER
IN FIELD
C PR -PRESSURE RECORDER
HP FLARE HEADER PS -PRESSURE SWITCH
CM CORROSION MONITORING UTILITY HEADER DESCRIPTION NG NATURAL GAS PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
DOUBLE BLOCK AND BLEED INTERCONNECTING LOGIC
DBB ALTERNATE DESIGN PRESSURE & 20694 CONNECTION DRAWING NUMBER OX OXYGEN (GASEOUS) C PX -PRESSURE POINT
ISOLATION PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
CSC CAR SEAL CLOSED MONITOR WITH 2 CONNECTIONS TEMPERATURE CHANGE OW OILY WATER PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
CSO CAR SEAL OPEN OWS OILY WATER SEWER SI -SPEED INDICATOR
(PLC) PROGRAMMABLE LOGIC
CONTROLLER, NORMALLY
S
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
VENT P OIL & OIL PRODUCTS (INC. SOUR / SWEET GAS) TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
FP/FB FULL PORT/BORE UTILITY (SERVICE CODE XXX) PA PROCESS AIR TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
XXX IBT -INVERTED BUCKET
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
CAN BE NORMALLY
FV FULL VACUUM FM FOAM MONITOR COMMISSIONING SYSTEM CHANGE PE POND EFFLUENT STEAM TRAP
(SELF-ACTUATED)
DISPLAYED ON CRT
TE -TEMP. ELEMENT
TSO -TIGHT SHUT OFF
RAIN HOOD PG PURGE GAS TG -THERMOMETER LOCAL DCS OR AUXILIARY
HH HAND HOLE S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
PO PUMP OUT S -DRAIN TO TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
TR -TEMP. RECORDER
PRESSURE SEWER
MOBILE MONITOR PS PRESSURISED SEWER TS -TEMP. SWITCH
(PLC) PROGRAMMABLE LOGIC
HV HALF VACUUM OWS -OILY WATER SEWER TT
CONTROLLER I/O POINT
-TEMP. TRANSMITTER
FLEXIBLE HOSE PT PUMP TRIMS D -DRAIN TTD -TEMP. TRANSDUCER
NORMALLY INACCESSIBLE
BY OPERATOR

MAXIMUM OPERATING PRESSURE & OPEN DRAINAGE (SERVICE CODE XXX) PW PROCESS WATER V -VENT TW -THERMOWELL
LC LOCKED CLOSED XXX
FOAM MANIFOLD TEMPERATURE CHANGE R REFRIGERANTS
REFERENCE DRAWINGS
LO LOCKED OPEN RA AGRU RICH AMINE
LETTER IDENTIFICATION OF LINES AD-036204
INJECTION QUILL RL RELIEF LINE
PIPING SYMBOLS AB-036227
MW MANWAY HOSE CABINET RLC COLD RELIEF LINE EQUIPMENT SYMBOLS AB-036305

SUPPLY RESPONSIBILITY CHANGE CLOSED DRAINAGE (SERVICE CODE XXX) RLW WARM RELIEF LINE INSTRUMENT SYMBOLS AC-036950
XXX PIPING LAYOUT INDEX
SO STEAM OUT RMEG RICH MEG
PLOT PLAN
LIVE HOSE REEL RP REFRIGERANT PROPANE
PROCESS FLOW DIAGRAM

NNF NORMALLY NO FLOW RW RAW WATER HYDROSTATIC TEST DIAGRAM

S STEAM (ATMOSPHERIC) DRAWING CONTROL FOR J.O.


INSTRUMENT INSTALLATION SCHEDULES
UC UTILITY CONNECTION CONSTRUCTION AREA BREAK SA SULFURIC ACID
SPRINKLER HEAD SC STEAM CONDENSATE (ATMOSPHERIC)
NC NORMALLY CLOSED SCA SPENT CAUSTIC
C 05 29 20
SD SULFUR DRAIN
B 02 14 20
SLOPES SPRAY NOZZLE END OF LINE SF SULFUR
A 09 24 19
SO SEAL OIL
REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
ELEVATIONS DOWNSTREAM SIREN
INTERFACE POINTS SYSTEM SOW SOUR WATER
REVISION VALIDATION
GRAVITY FLOW NEVER EXCEED INLET ELEVATIONS. SPO SLOP OIL (INCLUDING OILY SLUDGE)
LINE MAY CONTAIN POCKETS. LEAD CONTRACTOR THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
SR SEWER (STORM)
DISCIPLINE INDEX LETTER REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
FLOODING CONNECTIONS SW SALT WATER
SEQUENCE NUMBER
AREA CONTRACTOR CODE SWS SANITARY WATER
ELEVATION CHANGES ARE DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
50
1 CONSTANTLY DOWNWARD ONLY, WATER WELL TAD TGTU AMINE DRAIN (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
SLOP
E ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
NO POCKETS ARE PERMITTED. TLA TGTU LEAN AMINE UCH HJL
SPECIFIC SLOPES REQUIRED TPW TEMPERED WATER
05/29/20 05/29/20
POST INDICATOR VALVE IP-PPPP-L-NNNN
ARE SHOWN BY THIS SYMBOL. REV.NO. DATE REVISION DESCRIPTION DSN
TRA TGTU RICH AMINE
FXXX FXXX C 05/29/20 ISSUED FOR REVIEW 9429
DV DELUGE VALVE TW TREATED WATER
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
UA UTILITY AIR 10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED
FREE DRAINING UW UTILITY WATER
ELEVATION CHANGES ARE
DOWNWARD ONLY. PLANT NUMBER LIMIT VG VENT GAS SAUDI ARABIAN OIL COMPANY
DRAWING TYPE
NO POCKETS ARE PERMITTED. VT VESSEL TRIM PIPING & INSTRUMENTATION DIAGRAM
T80 T80 PID
SAFETY SHOWER &
WBD WET BLOWDOWN
EYEWASH STATION PIPING SYMBOLS AND LEGEND
WW WASTE WATER
NO LIQUID POCKETS IN THE LINE. UNIT NUMBER LIMIT 600C 600 PSIG H.P. CONDENSATE
COMMON AREA
NO POCKETS
WHEN NECESSARY TO PREVENT TANAJIB SAUDI ARABIA
90C 90 PSIG L.P. CONDENSATE
VAPOR POCKETS, THE NOTE WILL UNIT XX UNIT XX
600S 600 PSIG H.P. STEAM PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
READ "NO VAPOR POCKETS"
90S 90 PSIG L.P. STEAM T80 A CA-033800 001 C
Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
VESSELS/TANKS/DRUMS BLOWERS/PUMPS EXCHANGERS
1. THIS SYMBOLOGY SHEET DISPLAYS THE MOST COMMONLY
USED EQUIPMENT SYMBOLS.
HORIZONTAL VESSEL DEFLECTOR
PLATE

WEIR

CALMING BAFFLE CENTRIFUGAL PUMP SUMP PUMP RECIPROCATING


PUMP
SHELL AND TUBE WATER COOLED
HEAT EXCHANGER HEAT EXCHANGER
M

GEAR PUMP
PROGRESSIVE
VERTICAL VESSEL / COLUMN CAVITY PUMP

VERTICAL LINE KETTLE TYPE EXCHANGER DOUBLE PIPE EXCHANGER


SHAFT PUMP
DISTRIBUTOR
LPG VAPORISER
HORIZONTAL VESSEL WITH BOOT FAN OR BLOWER FAN CANNED PUMP
DEMISTER

PACKED SECTION/BED
DRIVERS
DRAWING PREVIOUSLY ISSUED AS
SHELL AND TUBE T76-A-PP-250600-002
AIR COOLER
EXCHANGER
(GENERIC) LEGEND
SURFACE CONDENSER
CATALYST BED M A PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN
C VS -VIBRATION SWITCH
AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
PROCESS LINE
FAILURE STEADY XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
TURBINE ENGINE ELECTRIC MOTOR AIR MOTOR AIR FAILURE CLOSE
AIR LINE XS -LIMIT SWITCH
NOZZLES INSTRUMENT
AO/AFS -AIR TO OPEN/AIR
FAILURE STEADY
ZV -SAFETY SHUTDOWN VALVE
ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
HEAT TRANSFER COIL F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
MANWAYS COMPRESSORS ATMOSPHERIC - HEATER/ ELECTRIC HEATING COIL ELECTRIC HEATER (2) DT -DENSITY TRANSMITTER
L-LEVEL
X-MISC.
T-TEMP.
A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
PLATE & FRAME SPIRAL PLATE VAPOURISER REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
DEAERATOR HEAT EXCHANGER HEAT EXCHANGER SPECTACLE
FC - FLOW CONTROLLER
MOUNTED INSTR.
FV -FLOW CONTROL VALVE
1 PASS TRAY PLATE-OPEN FCV -FLOW CONTROL VALVE
BOARD MOUNTED
(SELF-ACTUATED) INSTRUMENT
SPECTACLE FE -FLOW ELEMENT
PLATE-CLOSED FG -FLOW SIGHT GLASS
R/G
EL GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL
STATUS LIGHTS
R=RED, G=GREEN
2 PASS TRAYS SCREW COMPRESSOR HTR FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
2 DIAMETER COLUMN GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
LARGER DIA BOTTOM CHECK VALVE FM -FLOW METER

ELECTRIC HEATER HAIRPIN HEAT EXCHANGER FO -RESTRICTION ORIFICE MOTOR STATUS


CENTRIFUGAL COMPRESSOR RECIPROCATING COMPRESSOR PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
PILOT LIGHT

FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
4 PASS TRAYS MISCELLANEOUS DOUBLE DISC
GATE VALVE
FY
HIC
-FLOW RELAY
-HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE
E
HS -HAND SWITCH LOCAL PANEL
LA -LEVEL ALARM
M PRESS.RELIEF VALVE
LV -LEVEL CONTROL VALVE RACK MOUNTED
LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
SIEVE TRAY
LIQUID RING EQUIPMENT TRIM
(SELF-ACTUATED)
-LEVEL GAUGE GLASS
EXPANDER ROTARYCOMPRESSOR PUMP LG
-LEVEL INDICATOR CONTROLLER
ELECTRICAL
SUPPLY REQUIRED
TRIM: 1CS1P01 LIC
INLET VAPOUR DISTRIBUTOR VACUUM RELIEF VALVE LI -LEVEL INDICATOR
LR -LEVEL RECORDER INSTRUMENT

DRAW OFF PANS


FILTERS PIPE MATERIAL CLASS
M MOTOR OPERATED LS
LT
-LEVEL SWITCH
-LEVEL TRANSMITTER
AIR SUPPLY REQUIRED

VALVE H
LTD -LEVEL TRANSDUCER HIGH LOW
SEAL PANS CARBON CANISTER ML -MOTOR STATUS LIGHT L
P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
HALF PIPE DISTRIBUTOR VALVE PB -PUSHBUTTON
PC -PRESSURE CONTROLLER FF
CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
FIELDBUS INSTRUMENT
CHIMNEY TRAY PCV -PRESS. CONTROL VALVE
(SELF ACTUATED)
P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
VORTEX BREAKER VERTICAL DRUM INDICATOR CONTROLLER
(DCS) DISTRIBUTED CONTROL
AIR FILTER S
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL
SYSTEM, OPERATOR ACCESSIBLE
IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
VENDOR SCOPE BOUNDARY PIC -PRESS. INDICATOR CONTROLLER
IN FIELD
PR -PRESSURE RECORDER
PS -PRESSURE SWITCH
DISTRIBUTED CONTROL
GENERAL PT -PRESSURE TRANSMITTER
INTERCONNECTING LOGIC
FILTER MEDIA CARTRIDGE COALESCER xxxxxxxxx PX
PY
-PRESSURE POINT
-PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
FILTER FILTER FILTER xxxxxxxxx PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
SI -SPEED INDICATOR
SPRAY NOZZLES SS -SPEED SWITCH
CONTROLLER, NORMALLY
INACCESSIBLE OR BEHIND THE
BURN PIT TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
W/ CONCRETE BASIN TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
IBT -INVERTED BUCKET
SUMPS OIL SKIMMER STEAM TRAP
TE
(SELF-ACTUATED)
-TEMP. ELEMENT
CAN BE NORMALLY
DISPLAYED ON CRT
TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER (PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL

CONE ROOF TANK WITH SUMP CONE ROOF TANK WITH INTERNAL FLOATING ROOF REFERENCE DRAWINGS
STATIC MIXER
LETTER IDENTIFICATION OF LINES AD-036204
(AS EQUIPMENT ITEM)
PIPING SYMBOLS AB-036227
SPRAY SCRUBBER FLARE STACK
EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950

STORAGE SPHERE PIPING LAYOUT INDEX


PLOT PLAN
PROCESS FLOW DIAGRAM
HYDROSTATIC TEST DIAGRAM
SUMP DRAWING CONTROL FOR J.O.
ROTATING OIL SKIMMER INSTRUMENT INSTALLATION SCHEDULES
SCRAPER LAUNCHER/RECEIVER

C 05 29 20

B 02 14 20
M A 09 24 19

REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
TANK MIXER
AERATOR SPARGE BARS REVISION VALIDATION
IBC/HOPPER WITH MOTOR
THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
DOME ROOF TANK DOME ROOF TANK WITH INTERNAL FLOATING ROOF KERBED AREA
COOLING TOWER
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
05/29/20 05/29/20
WEIGH SCALES EJECTOR/EDUCTOR LOUVERS EDUCTOR TYPE REV.NO. DATE REVISION DESCRIPTION DSN
TANK MIXER C 05/29/20 ISSUED FOR REVIEW 9430
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY


DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
EQUIPMENT SYMBOLS & LEGEND
BUNDED AREA
COMMON AREA
TANAJIB SAUDI ARABIA
OPEN ROOF TANK FLOATING ROOF PRODUCT CLARIFIER INDUSTRIAL ONLY
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
TANK WITH DRAIN SUMP WATER BOOMS JET MIXER
CALIBRATION POT CONDENSATE POT TRUCK
GRADE T80 A CA-033800 002 C
Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
SIGNAL LINES GENERAL INSTRUMENT SYMBOLS FLOW THERMAL RELIEF VALVE DETAIL PRESSURE
1. DELETED.
2. PIPING TO SUPPLY NPT(F) CONNECTION FOR INSTRUMENT
CONNECTION TO PROCESS IMPULSE LINE.
XX FO PRESSURE REGULATOR WITH 3. DETAIL APPICABLE FOR PIPING. IF PI/PT CONNECTED TO
INSTRUMENT LOCATED IN FIELD +
PZV PZV
+
+ EXTERNAL TAP VESSEL. PIPING ISOLATION VALVE TO BE 2" WITH 3/4 NPT(F)
ELECTRIC SIGNAL RESTRICTION ORIFICE CONNECTION FOR INSTRUMENT IMPULSE LINE.
CSO 4. IF PRESSURE GAUGE / TRANSMITTER IS MOUNTED
XX LOCAL PANEL MOUNTED INSTRUMENT NOTE 8 DIFFERENTIAL PRESSURE REDUCING REMOTELY THEN CAPILLARY TUBE SHOULD BE SHOWN.
CAPILLIARY TUBING 5. NO THERMOWELL IS REQUIRED FOR SURFACE OR SKIN
NORMALLY OPERATOR ACCESSIBLE FE CSO SHOWN ON P&ID REGULATOR WITH EXTERNAL TAPS
+ MEASUREMENT.
6. REPLACE PLC WITH CRMS, CCS, MPS ETC. AS APPLICABLE.
PNEUMATIC SIGNAL CENTRAL OR MAIN ORIFICE PLATE AND FLANGES
XX 7. VALVE TYPE IS BASED ON THE T80-L-PP-963014 APPENDIX. A.
SELF CONTAINED
BOARD MOUNTED INSTRUMENT 8. ISOLATION VALVE OF PZV OUTLET IS NOT REQUIRED WHEN
BACKPRESSURE REGULATOR
SOFTWARE LINK NORMALLY OPERATOR ACCESSIBLE DISCHARGING TO ATM.
9. MINIMUM 3 INCH FOR THERMOWELL INSTALLATION. ENLARGER
TO BE PROVIDED, IF LINE SIZE IS SMALLER THAN 3".
WIRELESS SIGNAL
XX RACK MOUNTED OR BACK OF PANEL INSTRUMENT ORIFICE PLATE AND QUICK CHANGE FITTING UTILITY STATION SELF CONTAINED 10. THE SIZE OF FLANGED ISOLATION VALVE IS 3" FOR 3" OR LARGER
NOT NORMALLY OPERATOR ACCESSIBLE PRESSURE REDUCING REGULATOR PIPELINE AND 2" FOR 2" PIPELINE. FOR 1" PIPELINE, REFER TO
C
CA-033800-007 NOTE 21.
HYDRAULIC SIGNAL HH PRESSURE INDICATOR TO BE 11. FOR STEAM, CAUSTIC, ACID, CATEGORY M, OFFGAS LETHAL AND
XX H READABLE AT UTILITY STATION RELIEF VALVE SOUR SERVICES, FLANGED TYPE IS APPLIED TO ROOT VALVE
SOFTWARE ALARMS WITH SHARED DISPLAY DEVICE INSTEAD OF THREAD TYPE.
L
INSTRUMENT TAGGING LL FLOW STRAIGHTENING VANE PI 12. MANIFOLD VALVE OR FLUSHING RING CAN BE APPLIED.
RELIEF VALVE ORIFICE AND CONNECTION SIZES C
UNIT NUMBER AS PER NOTE ON P&ID TYPICAL UTILITY COUPLING TYPE AND 4"P6" PRESSURE SETTING
XX PILOT LIGHT LOCATED IN FRONT OF CENTRAL STATION 1-1/2" 1-1/2"x1" 1" 1"x3/4"
DETAILS AS PER PSET=23.0 PSIG PZV DRAWING PREVIOUSLY
OR MAIN PANEL CENNECTION SAES-L-310
FI ISSUED AS
+

MEASURED VARIABLE VARIABLE AREA FLOW INSTRUMENT (AIR, NITROGEN, WATER) ROOT PZV
+
1" SECTION 18 +

INSTRUMENT FUNCTION TYPE


VALVE
PRESSURE RELIEF VALVE
ANGLE BUCKLING PIN T76-A-PP-250600-003
(ISA CODE) MAX 5 CHARACTERS PI RELIEF VALVE
DISTRIBUTED CONTROL SYSTEM / SHARED DISPLAY SYMBOLS
PI PZV
XXXX A PVRV +

TYPICAL UTILITY COUPLING TYPE AND +

STATION 1-1/2" 1-1/2"x1" 1" PRESSURE / VACUUM


XX PP DETAILS AS PER INLINE BUCKLING
INSTRUMENT SUFFIX (DCS) DISTRIBUTED CONTROL SYSTEM VARIABLE AREA FLOW INSTRUMENT CENNECTION RELIEF VALVE LEGEND
+
SAES-L-310 PIN RELIEF VALVE
(ONE ALPHA CHARACTER) OPERATOR ACCESSIBLE IN CONTROL ROOM WITH UPSTREAM REGULATOR (STEAM) 1" SECTION 18 PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
INSTRUMENT SEQUENCE NUMBER PZV PZV P
AC/AFO -AIR TO CLOSE/
AIR FAILURE OPEN
VE -VIBRATION ELEMENT
VS -VIBRATION SWITCH
(4 DIGITS) XX (DCS) DISTRIBUTED CONTROL SYSTEM
+
+
AC/AFS -AIR TO CLOSE/AIR VT
VACUUM RELIEF VALVE PILOT RELIEF VALVE PROCESS LINE
FAILURE STEADY XL
-VIBRATION TRANSMITTER
-PILOT LIGHT
OPERATOR INACCESSIBLE IN CONTROL ROOM INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
VARIABLE AREA FLOW INSTRUMENT LEVEL AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH

CONTROL VALVES
+
AO/AFS -AIR TO OPEN/AIR ZV
WITH DOWNSTREAM VALVE INSTRUMENT
FAILURE STEADY
-SAFETY SHUTDOWN VALVE

XX ELECTRICAL LINE
DCS LOCATED IN THE LOCAL PANEL
NORMALLY ACCESSIBLE TO OPERATOR
PRESSURE INDICATION / TRANSMITTER NOTE 11 AOV -AIR OPERATED VALVE DATA LOGGER POINT
F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
RADIATION, SINGLE L-LEVEL T-TEMP.
BALL VALVE NCR : NON-CONTACT RADAR DT -DENSITY TRANSMITTER
A-ALARM
POINT. SONIC. X-MISC.

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
GWR : GUIDED WAVE RADAR SEE ARAMCO DWG DC-950040 FOR GUIDELINE. FC - FLOW CONTROLLER
MOUNTED INSTR.
SPECTACLE
XX (DCS) DISTRIBUTED CONTROL SYSTEM RADIATION, MULTI-POINT FV -FLOW CONTROL VALVE
VARIABLE AREA FLOW INSTRUMENT INT : INTERFACE PLATE-OPEN
BUTTERFLY VALVE OPERATOR ACCESSIBLE IN FIELD +
OR CONTINUOUS P&ID SCHEMATIC FCV -FLOW CONTROL VALVE
WITH UPSTREAM VALVE TYPICAL INSTALLATION (SELF-ACTUATED)
BOARD MOUNTED
DP : DIFFERENTIAL PRESSURE REPRESENTATION SPECTACLE FE -FLOW ELEMENT
INSTRUMENT

PLATE-CLOSED R/G
GATE VALVE (OR CONTROL PI/PT FG -FLOW SIGHT GLASS
STATUS LIGHTS
VALVE TYPE IS UNDESIGNATED) LEVEL GAUGE / TRANSMITTER MOUNTED DIRECTLY ON VESSEL/TANK GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
EMERGENCY SHUTDOWN SYSTEM (ESD) SYMBOLS 3/4" NPT GLOBE VALVE
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
1" V 1/2" PI/PT FM -FLOW METER
GLOBE VALVE INST
CHECK VALVE
FO -RESTRICTION ORIFICE MOTOR STATUS
SHOWN ON P&ID PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
PILOT LIGHT

ZC FLOW NOZZLE 2" 2" PIPING 3/4" FR -FLOW RECORDER


PLUG VALVE LOCATED IN FIELD - NORMALLY OPERATOR ACCESSIBLE BALL VALVE
FT -FLOW TRANSMITTER ML LOCAL MOUNTED

CSO CSO NOTE 2, 3, 12 DOUBLE DISC FY -FLOW RELAY


INSTRUMENT

GATE VALVE -HAND INDICATOR CONTROLLER


SEGMENT BALL VALVE C LG SHOWN ON P&ID LG ANGLE VALVE
HIC MOUNTED BEHIND
HS -HAND SWITCH LOCAL PANEL
ZC LOCATED IN FRONT OF CENTRAL OR MAIN CONSOLE PI/PT
LA -LEVEL ALARM
LV -LEVEL CONTROL VALVE RACK MOUNTED
NORMALLY OPERATOR ACCESSIBLE 2" 2" PRESS.RELIEF VALVE
VENTURI TUBE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
ACTUATOR TYPES NOTE 4, 12
(SELF-ACTUATED)
CSO CSO LG -LEVEL GAUGE GLASS ELECTRICAL
-LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
ZC LOCATED IN REAR OF CENTRAL OR MAIN CONSOLE PIPING INST PIPING INST LIC
VACUUM RELIEF VALVE LI -LEVEL INDICATOR
NOT NORMALLY OPERATOR ACCESSIBLE 1/2" PI/PT LR -LEVEL RECORDER INSTRUMENT
AIR SUPPLY REQUIRED
ULTRASONIC FLOW METER 1" D SHOWN ON P&ID M MOTOR OPERATED LS -LEVEL SWITCH
INST VALVE LT -LEVEL TRANSMITTER
H
DIAPHRAGM PIPING
LTD -LEVEL TRANSDUCER HIGH LOW
LT NOTE 10 ML -MOTOR STATUS LIGHT L
P MOV -MOTOR OPERATED VALVE

GWR LT PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER


PROGRAMMABLE LOGIC CONTROLLER (PLC) SYMBOLS VALVE PB -PUSHBUTTON
PISTON CYLINDER, GWR PC -PRESSURE CONTROLLER FF
FOUNDATION
SINGLE OR DOUBLE ACTING M MAGNETIC FLOW METER 1" PI/PT
CONTROL VALVE PV -PRESS. CONTROL VALVE
FIELDBUS INSTRUMENT
PCV -PRESS. CONTROL VALVE
PLC 2" 2" (SELF ACTUATED)
V DISTRIBUTED CONTROL/SHARED
NOTE 6 LOCATED IN THE FIELD - NORMALLY OPERATOR ACCESSIBLE P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER
1/2" CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
CSO CSO WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
M INST PI/PT (DCS) DISTRIBUTED CONTROL
SHOWN ON P&ID C S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
ELECTRIC MOTOR PLC TURBINE OR PD METER PIPING C SHOWN ON P&ID SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM

NOTE 6 LOCATED IN FRONT OF CENTRAL OR MAIN CONSOLE 3/4" INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
NORMALLY OPERATOR ACCESSIBLE 2" 2" VALVE NORMALLY
PDT -PRESS. DIFF. TRANSMITTER
SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
CSO CSO DBB NOTE 7 PI -PRESSURE INDICATOR (DCS) DISTRIBUTED CONTROL
PLC 3/4" SYSTEM, OPERATOR INACCESSIBLE
PIPING INST PIPING INST PIC -PRESS. INDICATOR CONTROLLER
DIAPHRAGM ACTUATOR NOTE 6 LOCATED IN REAR OF CENTRAL OR MAIN CONSOLE VORTEX FLOW METER 1" D PR -PRESSURE RECORDER
IN FIELD

WITH E/P POSITIONER NOT NORMALLY OPERATOR ACCESSIBLE PS -PRESSURE SWITCH


PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
INTERCONNECTING LOGIC
1" V PI/PT
PX -PRESSURE POINT
PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
2" LT (PLC) PROGRAMMABLE LOGIC
FUNCTIONAL SYMBOLS CORIOLIS FLOW METER
SI
SS
-SPEED INDICATOR
-SPEED SWITCH
CONTROLLER, NORMALLY
INACCESSIBLE OR BEHIND THE
CSO GWR 1/2" TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
INST PI/PT TV -TEMP. CONTROL VALVE
INST PIPING C SHOWN ON P&ID TCV -TEMP. CONTROL VALVE
(PLC) PROGRAMMABLE LOGIC
CONTROLLER FUNCTION,
BIAS PLUS SUMMATION 2" 2" PIPING IBT -INVERTED BUCKET
DIAPHRAGM ACTUATOR STEAM TRAP
(SELF-ACTUATED) CAN BE NORMALLY
3/4" TE -TEMP. ELEMENT DISPLAYED ON CRT
WITH HANDWHEEL TSO -TIGHT SHUT OFF
WEDGE FLOW METER TG -THERMOMETER LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
BIAS MINUS X MULTIPLICATION LG MIN. C DBB
3/4" S -DRAIN TO TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR

S 4" PRESSURE SEWER TR -TEMP. RECORDER


(PLC) PROGRAMMABLE LOGIC
SOLENOID - 2 WAY OWS -OILY WATER SEWER
TS -TEMP. SWITCH
CONTROLLER I/O POINT
BIAS PLUS OR MINUS DIFFERENCE TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
INTEGRAL ORIFICE ASSEMBLY 2" 2" V -VENT TW -THERMOWELL
PI PI
LOW SELECTOR f(x) UNSPECIFIED FUNCTION 2" PIPING INST
S
E CSO REFERENCE DRAWINGS
SOLENOID - 3 WAY
HIGH SELECTOR n AVERAGE VALUE SYPHON WITH INTEGRAL DIAPHRAGM LETTER IDENTIFICATION OF LINES AD-036204
DE
INTEGRAL DIAPHRAGM WITH COLLING TOWER PIPING SYMBOLS AB-036227

2" D EQUIPMENT SYMBOLS AB-036305


INSTRUMENT SYMBOLS AC-036950
PIPING LAYOUT INDEX
HAND ACTUATED MISCELLANEOUS C
PI PI PLOT PLAN

1" UNION OR FLANGE PROCESS FLOW DIAGRAM


THIS DETAIL ONLY FOR SERVICES NOT
HYDROSTATIC TEST DIAGRAM
REQUIRING CONNECTION TO A CLOSED
MCC MOTOR CONTROL CENTRE
DRAIN SYSTEM. SYPHON PULSATION DAMPER DRAWING CONTROL FOR J.O.
VALVE ACTION FLOW ORIFICE TRANSMITTER NOTE 11 INSTRUMENT INSTALLATION SCHEDULES

CHEMICAL OR DIAPHRAGM SEAL


FOR GUIDELINE OF LEVEL HOOK-UPS REFER TO SAUDI
ORIENTATION OF PRESSURE TAP IS ARAMCO DRAWINGS M88-L-DC-950045, M88-J-DC-950051 & M88-J-DB-950046.
FF FOUNDATION FIELDBUS P&ID SCHEMATIC
SHOWN IN AD-036004 - ORIENTATION C 05 29 20
REPRESENTATION
RUPTURE DISC VACUUM
FOR ORIFICE FLANGES.
1" V
LT TEMPERATURE B 02 14 20
AC/AFO FT
GWR LT A 09 24 19
VALVE ACTION RUPTURE DISC PRESSURE 1" V
2" SHOWN ON P&ID TI REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
GWR
INST 1" REVISION VALIDATION
CSO 2"
AC/AFO - AIR TO CLOSE / AIR FAILURE OPEN CC CORROSION COUPON FT
PIPING 1/2" 1/2" INST PIPING V THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
CSO TW TI
AO/AFC - AIR TO OPEN / AIR FAILURE CLOSE SHOWN ON P&ID
PIPING INST REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
1" V INST PIPING
AC/AFS - AIR TO CLOSE / AIR FAILURE STEADY SHOWN ON P&ID
CE CT 2" 2" 2" PIPE
2"
AO/AFS - AIR TO OPEN / AIR FAILURE STEADY CORROSION PROBE/ DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
CORROSION TRANSMITTER
FF
FE LG MIN. LG MIN. NOTE 9 ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
THE FOLLOWING SHALL BE USED WHEN FE +
4" 4" VESSEL TI UCH
05/29/20
HJL
05/29/20
THE VALVE ACTUATOR IS NOT PNUEMATIC +
C C /TANK
REV.NO. DATE REVISION DESCRIPTION DSN
FC - FAIL CLOSED CCS COMPRESSOR CONTROL SYSTEM 2"
C 05/29/20 ISSUED FOR REVIEW 9431
2" 2" 2"
MPS MACHINE PROTECTION SYSTEM DBB DOUBLE BLOCK AND BLEED ISOLATION PIPING INST JOB ORDER/EWO NO.
1" D 1" D THIS REVISION IS NOT TO BE USED FOR
FL - FAIL LOCKED LAST POSITION CRMS CORROSION MONITORING SYSTEM INST 10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED
NOTE 7 2" PIPING 2" TT TI TT TI
FO - FAIL OPEN
FLO - FAIL LOCKED / VALVE OPENS ON
STMS STEAM TRAP MONITORING SYSTEM
CSO
C
CSO
C SAUDI ARABIAN OIL COMPANY
X"x2" DRAWING TYPE
DECREASING CONTROL X"xX"
PIPING & INSTRUMENTATION DIAGRAM PID
FLC - FAIL LOCKED / VALVE CLOSES ON EARTHING SYMBOL SAMPLE CONNECTION
DECREASING CONTROL 2" X" D
TW TE RTD OR T/C TE
INSTRUMENT SYMBOLS AND LEGEND
SHOWN ON P&ID NOTE 5 COMMON AREA
SC 2"x1"
TIGHT SHUT-OFF TANAJIB SAUDI ARABIA
TSO PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
TO ASSOCIATED DRAIN TO ASSOCIATED DRAIN NOTE 9
ARRANGEMENT ARRANGEMENT T80 A CA-033800 003 C
Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTE CONT'D.: NOTES:
LOCAL CONTROL PANEL LOCAL CONTROL PANEL 1. EPC CONTRACTOR SHALL EXPAND THE LEGEND SHEET AS
10. MCC DRIVE HAS PROVISION FOR AUTOMATIC START / STOP REQUIRED TO IMPLEMENT THE TAGGING OF ALL INSTRUMENT
VALVE READY VALVE READY ONLY WHEN INDICATED ON P&ID. ITEMS SHOWN ON THE LEGEND SHEET SPECIFIC DETAILS
TEST TO OPEN OPEN CLOSE OPEN CLOSED TEST TO OPEN OPEN CLOSE OPEN CLOSED 11. MCC DRIVE HAS PROVISION FOR REMOTE START FROM DCS INCLUDING THE LOCAL ELECTRICAL SWITCHES AND LAMPS.
ONLY WHEN AUTOMATIC START / STOP IS INDICATED ON P&ID. 2. LOOP TAG NUMBERS AS IDENTIFIED ON P&ID'S SHALL APPLY
ZHS ZXL ZHS ZHS ZXL ZXL ZHS ZXL ZHS ZHS ZXL ZXL 12. MCC DRIVE HAS PROVISION FOR ESD TRIP ONLY WHEN TO ALL OTHER INSTRUMENT ITEMS SHOWN ON THE LEGEND
C A B O C C A B O C INDICATED ON P&ID. SHEET SPECIFIC DETAIL.
13. WHERE AHS OR MHS IS SHOWN ON THE P&ID THIS 3. THE MAIN CRITERIA TO SELECT DOUBLE ACTING OR SPRING
REPRESENTS THE DEVICE FACEPLATE WITH ALL FUNCTIONS RETURN ACTUATOR IS RELATED TO THE FAIL ACTION.
SHOWN IN THE ASSOCIATED DETAIL AS A MINIMUM. FOR FAIL LAST : DOUBLE ACTING
14. AIR STORAGE ACCUMULATOR LOCATED OUTSIDE THE FIRE- FOR FAIL OPEN OR CLOSE : SPRING RETURN
HAZARDOUS ZONE SHALL BE CONNECTED TO INSTRUMENT AIR SPRING RETURN ACTUATORS ARE REQUIRED AS INDICATED
HEADER VIA DOUBLE NON-RETURN, CHECK VALVES. ACCUMULATOR IN THE PROJECT DRAWINGS. HOWEVER, FOR APPLICATIONS
RESET PROPRIETARY RESET PROPRIETARY SIZED TO CLOSE THE VALVE (THREE STROKES). ACCUMULATOR WHERE HIGH TORQUE REQUIREMENTS OR SPACE LIMITATIONS
COMMS LINK COMMS LINK PRESSURE INDICATOR SHALL BE TAGGED DURING DETAILED DESIGN. (LAYOUT), OR DIFFICULT-TO-MAINTAIN, AND/OR 'FAIL LAST' ARE
ZHS ZHS 15. RESET TO BE PROVIDED WHERE APPLICABLE. ENCOUNTERED. THE USE OF DOUBLE ACTING (SPRINGLESS)
F F 16. FOR PUMPS THE INDIVIDUAL ZV SAFE LOCATION BUTTONS (ZHS G) ACTUATORS IN ACCORDANCE WITH SAES-J-601 SECTION 8.3
ZLS ZLS SHALL BE REPLACED BY A COMMON SAFE LOCATION BUTTON THAT
VALVE TEST
CAN BE CONSIDERED SUBJECT TO COMPANY APPROVAL.
VALVE TEST O O SHALL STOP DRIVE, CLOSE SUCTION, DISCHARGE AND RECYCLE ZV'S 4. VALVES SHOWN AS BALL VALVES ARE TYPICAL ONLY. ACTUAL
ZHS ZHS AS APPLICABLE. THE COMMON BUTTON IS SHOWN ON THE P&ID VALVE TYPE SHALL BE SHOWN ON P&ID.
E ZLS E ZLS CONNECTED TO THE PUMP SUCTION ZV WITH ASSOCIATED NOTE. 5. LOCAL MCS SIGNALS NOT TAGGED.
C C IN SUCH CASES THE ZV'S SHALL BE SHOWN AS DETAIL 1A. 6. THE INSTRUMENT AIR SHALL BE SUPPLIED FROM AN
OPEN C OPEN C 17. ALL ZV'S ACROSS THE PROJECT HAVE FULL STROKING TESTING
CLOSE
INDEPENDENT RELIABLE BACKUP SOURCE, AS DETAILED C
CLOSE REQUIREMENT AND STROKE TESTING IS PERFORMED AS PER
ZLL UC ZLL UC IN SAES-J-601, SECTION 8.5.
ZC ZHS ZC ZHS REQUIREMENT SPECIFIED IN SECTION 11.3.2(C, D) OF SAES-J-601 AND 7. ZV POSITION LIMIT SWITCHES SHALL BE CONNECTED TO DCS.
O O
G G APPENDIX K OF SAEP-250. IF ZV VALVE POSITION IS A SIF INITIATOR, THEN ADDITIONAL
CLOSED CLOSED NOTE 8 POSITION TRANSMITTER SHALL BE USED AS AN ESD INPUT.
NOTE 8, 16 8. ACTUATING BUTTON SHALL BE INSTALLED IN A SAFE
ZLL ZY ZLL ZY ZY
+ + + LOCATION IN ACCORDANCE WITH SAES-B-058.
C S C A S S B 9. VALVE HAS PROVISION FOR AUTOMATIC OPERATION ONLY
ERROR ERROR WHEN INDICATED ON P&ID.
C
ZA DE ZA DE DE
DRAWING PREVIOUSLY ISSUED AS
ZXY T76-A-PP-250600-004
+

VENT VENT VENT C


ZXY LEGEND
SMART SMART +

POSITIONER IAS POSITIONER


PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
IAS AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT

CLOSE CLOSE NOTE 6 AIR FAILURE OPEN VS -VIBRATION SWITCH


DETAIL 1 OR 1A DETAIL 2 PROCESS LINE AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER

ZHS P&ID SYMBOL ZHS P&ID SYMBOL FAILURE STEADY XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
D D OPEN CLOSE AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
AO/AFS -AIR TO OPEN/AIR ZV
ZC ZC INSTRUMENT
FAILURE STEADY
-SAFETY SHUTDOWN VALVE
POSITION DETAIL 1 OR 1A POSITION DETAIL 2 ELECTRICAL LINE
AOV -AIR OPERATED VALVE DATA LOGGER POINT
F-FLOW P-PRESS.
ZXI ZXI

INPUTS
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
DT -DENSITY TRANSMITTER
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
ZV ZV REDUCER ESD -EMER. SHUTDOWN SYSTEM
ZV NOTE 7, 17 + ZV NOTE 7, 17 +
FC - FLOW CONTROLLER
LOCAL PANEL
+
+
SPECTACLE MOUNTED INSTR.
FV -FLOW CONTROL VALVE
PLATE-OPEN FCV -FLOW CONTROL VALVE
BOARD MOUNTED
(SELF-ACTUATED) INSTRUMENT
SPECTACLE
DETAIL 1 OR 1A (SEE NOTE 16) DETAIL 2 PLATE-CLOSED
FE -FLOW ELEMENT
R/G
FG -FLOW SIGHT GLASS
SMART ZV VALVE - SPRING RETURN SMART ZV VALVE - DOUBLE ACTING STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)

CHECK VALVE FM -FLOW METER


FO -RESTRICTION ORIFICE MOTOR STATUS
PILOT LIGHT
ON ACTUATOR NOTE 1 PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
LOCAL/OFF DOUBLE DISC FY -FLOW RELAY
REMOTE GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
MHS LA -LEVEL ALARM
LV -LEVEL CONTROL VALVE
D PRESS.RELIEF VALVE -LEVEL CONTROL VALVE
RACK MOUNTED
LCV (OR BACK OF PANEL)
(SELF-ACTUATED)
OPEN LG -LEVEL GAUGE GLASS
LOCAL/REMOTE -LEVEL INDICATOR CONTROLLER
ELECTRICAL
SUPPLY REQUIRED
AHS UC STOP STATUS
LIC
VACUUM RELIEF VALVE LI -LEVEL INDICATOR
A MHS MXL LR -LEVEL RECORDER INSTRUMENT
LS -LEVEL SWITCH AIR SUPPLY REQUIRED
M MOTOR OPERATED
ERROR OPEN CLOSE C LT -LEVEL TRANSMITTER
VALVE H
LTD -LEVEL TRANSDUCER HIGH LOW
BA UC ZC BHS AHS STOP ML -MOTOR STATUS LIGHT L
-MOTOR OPERATED VALVE
A B CLOSE MHS
P
PISTON OPERATED
MOV
NA -ANNUNCIATOR TWO PEN RECORDER
G VALVE PB -PUSHBUTTON
PI OPEN AY MHS PC -PRESSURE CONTROLLER
+ FF
RESET BY ALL S B CLOSE CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
+ PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT

BHS S O MHS (SELF ACTUATED)


IAS BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
B OPEN F
P
CLOSED DE CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
IAS WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
NOTE 15 DE ALL MHS OPEN INDICATOR CONTROLLER
(DCS) DISTRIBUTED CONTROL
S SYSTEM, OPERATOR ACCESSIBLE
C A SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
VENT MHS
AIR STORAGE INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
OPEN VENT ERROR E PDT -PRESS. DIFF. TRANSMITTER
ACCUMULATOR VALVE NORMALLY
PDTD -PRESS. DIFF. TRANSDUCER
SYSTEM, OPERATOR INACCESSIBLE
IN CONTROL ROOM
OPEN CLOSED
BLL NOTE 14 AA OPEN PG -PRESSURE GAUGE
(DCS) DISTRIBUTED CONTROL
PI -PRESSURE INDICATOR
O ALS ALS MXL MLL PIC -PRESS. INDICATOR CONTROLLER
SYSTEM, OPERATOR INACCESSIBLE
IN FIELD
PR -PRESSURE RECORDER
O C O O PS -PRESSURE SWITCH
PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
CLOSED CLOSED PX -PRESSURE POINT INTERCONNECTING LOGIC
CLOSED PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
BLL MLL PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
C MXL C RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
BLS SI -SPEED INDICATOR CONTROLLER, NORMALLY
C POSITION SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
C TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
MLS MLS MXT MXI TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
BLS DETAIL 3 C O IBT -INVERTED BUCKET
CAN BE NORMALLY
(SELF-ACTUATED)
STEAM TRAP
O P&ID SYMBOL AOV DETAIL 4 DETAIL 5
TE -TEMP. ELEMENT DISPLAYED ON CRT
TSO -TIGHT SHUT OFF TG -THERMOMETER
+
M LOCAL DCS OR AUXILIARY
P&ID SYMBOL P&ID SYMBOL S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY

BV ZC S -DRAIN TO TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR


+ DETAIL 3 ERROR PRESSURE SEWER TR -TEMP. RECORDER
(PLC) PROGRAMMABLE LOGIC
AHS MHS TS -TEMP. SWITCH
CONTROLLER I/O POINT
DETAIL 4 MA DETAIL 5 OWS -OILY WATER SEWER TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
BV MOV FF V -VENT TW -THERMOWELL
FF
+ +

AOV MOV
+ +
M
DETAIL 3 DETAIL 4 REFERENCE DRAWINGS
DETAIL 5
BLOWDOWN VALVE - SPRING RETURN ON-OFF CONTROL VALVE (AOV)-DCS CONTROLLED LETTER IDENTIFICATION OF LINES AD-036204
MOTOR OPERATED VALVE (FIELDBUS)
NOTE 9 NOTE 9 PIPING SYMBOLS AB-036227
EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950
LOCAL ELECTRICAL MOTOR CONTROL STATION LOCAL ELECTRICAL MOTOR CONTROL STATION
PIPING LAYOUT INDEX

NOTE 5 C NOTE 5 C OPEN PLOT PLAN

LOCAL/OFF LOCAL/OFF AHS UC


PROCESS FLOW DIAGRAM
/REMOTE /REMOTE HYDROSTATIC TEST DIAGRAM
START STOP RUNNING STOPPED START STOP RUNNING STOPPED A
H/O/A H/O/A DRAWING CONTROL FOR J.O.
CLOSE INSTRUMENT INSTALLATION SCHEDULES

AHS
B

OPEN AY C 05 29 20
+

ALL S B 02 14 20
RUNNING
/STOPPED O A 09 24 19
LOCAL/REMOTE IAS
STATUS ML CLOSED REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
DE
MXL ALL REVISION VALIDATION
C VENT THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
LOCAL/REMOTE
STATUS REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
RUNNING/STOPPED ERROR
ML MXL AA
MCC MCC ALS ALS DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
STOP STOP O C ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
MHS DETAIL 7 MHS MHS 05/29/20 05/29/20

B P&ID SYMBOL B REV.NO. DATE REVISION DESCRIPTION DSN


C 05/29/20 ISSUED FOR REVIEW 9432
START MHS
COMMON FAULT JOB ORDER/EWO NO.
MHS THIS REVISION IS NOT TO BE USED FOR
DETAIL 7 A 10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED
M MA
M COMMON FAULT DETAIL 9 SAUDI ARABIAN OIL COMPANY
MA DETAIL 8 AOV P&ID SYMBOL DRAWING TYPE
+ PIPING & INSTRUMENTATION DIAGRAM PID
M DETAIL 8
UC
P&ID SYMBOL DETAIL 9 INSTRUMENT SYMBOLS AND LEGEND
M COMMON AREA
DETAIL 7 DETAIL 8
AOV
+
TANAJIB SAUDI ARABIA
LV PUMP MOTOR WITH DCS CONTROL FAN MOTOR WITH DCS CONTROL DETAIL 9 PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
ON-OFF CONTROL VALVE (AOV)-PLC CONTROLLED
NOTE 10, 11, 12 NOTE 10, 12
T80 A CA-033800 004 C
Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTE CONT'D.: NOTES:
C
LOCAL ELECTRICAL MOTOR CONTROL STATION 1. EPC CONTRACTOR SHALL EXPAND THE LEGEND SHEET AS
8. VALVES SHOWN AS BALL VALVES ARE TYPICAL REQUIRED TO IMPLEMENT THE TAGGING OF ALL INSTRUMENT
ONLY. ACTUAL VALVE TYPE SHALL BE SHOWN ITEMS SHOWN ON THE LEGEND SHEET SPECIFIC DETAILS
LOCAL/OFF
NOTE 4
ON P&ID. INCLUDING THE LOCAL ELECTRICAL SWITCHES AND LAMPS.
/REMOTE 9. MCC DRIVE HAS PROVISION FOR AUTOMATIC
HOA START STOP RUNNING STOPPED 2. LOOP TAG NUMBERS AS IDENTIFIED ON P&ID'S SHALL APPLY
START / STOP ONLY WHEN INDICATED ON P&ID. TO ALL OTHER INSTRUMENT ITEMS SHOWN ON THE LEGEND
LOCAL CONTROL PANEL 10. MCC DRIVE HAS PROVISION FOR REMOTE START SHEET SPECIFIC DETAIL.
FROM DCS ONLY WHEN AUTOMATIC START / STOP 3. THE MAIN CRITERIA TO SELECT DOUBLE ACTING OR SPRING
VALVE READY IS INDICATED ON P&ID. RETURN ACTUATOR IS RELATED TO THE FAIL ACTION.
TEST TO OPEN OPEN CLOSE OPEN CLOSED 11. MCC DRIVE HAS PROVISION FOR ESD TRIP ONLY FOR FAIL LAST : DOUBLE ACTING
WHEN INDICATED ON P&ID. FOR FAIL OPEN OR CLOSE : SPRING RETURN
ZHS ZXL ZHS ZHS ZXL ZXL
LOCAL CONTROL PANEL 12. WHERE AHS OR MHS IS SHOWN ON THE P&ID THIS SPRING RETURN ACTUATORS ARE REQUIRED AS INDICATED
C A B O C REPRESENTS THE DEVICE FACEPLATE WITH ALL
VALVE READY IN THE PROJECT DRAWINGS. HOWEVER, FOR APPLICATIONS
TEST TO OPEN OPEN CLOSE OPEN CLOSED FUNCTIONS SHOWN IN THE ASSOCIATED DETAIL WHERE HIGH TORQUE REQUIREMENTS OR SPACE LIMITATIONS
LOCAL/REMOTE AS A MINIMUM.
ZHS ZXL ZHS ZHS ZXL ZXL STATUS (LAYOUT), OR DIFFICULT-TO-MAINTAIN, AND/OR 'FAIL LAST' ARE
13. FOR PUMPS THE INDIVIDUAL ZV SAFE LOCATION ENCOUNTERED. THE USE OF DOUBLE ACTING (SPRINGLESS)
C A B O C
MXL
BUTTONS (ZHS G) SHALL BE REPLACED BY A ACTUATORS IN ACCORDANCE WITH SAES-J-601 SECTION 8.3
COMMON SAFE LOCATION BUTTON THAT SHALL CAN BE CONSIDERED SUBJECT TO COMPANY APPROVAL.
RESET STOP DRIVE, CLOSE SUCTION, DISCHARGE AND 4. LOCAL MCS SIGNALS NOT TAGGED.
ZHS PROPRIETARY RECYCLE ZV'S AS APPLICABLE. THE COMMON 5. TWO SPEED FAN. HIGH SPEED CANNOT BE
COMMS LINK BUTTON IS SHOWN ON THE P&ID CONNECTED TO C
F RESET PROPRIETARY RUNNING/STOPPED INITIATED UNTIL LOW SPEED HAS BEEN STARTED.
ZLS COMMS LINK THE PUMP SUCTION ZV WITH ASSOCIATED NOTE. 6. ZV POSITION LIMIT SWITCHES SHALL BE CONNECTED TO DCS.
VALVE TEST O ZHS ML IN SUCH CASES THE ZV'S SHALL BE SHOWN AS IF ZV VALVE POSITION IS A SIF INITIATOR, THEN ADDITIONAL
ZHS F DETAIL 10A. POSITION TRANSMITTER SHALL BE USED AS AN ESD INPUT.
E ZLS 7. ACTUATING BUTTON SHALL BE INSTALLED IN A SAFE LOCATION IN
VALVE ACCORDANCE WITH SAES-B-058.
C ZLS
OPEN TEST
C O MCC
CLOSE
ZLL UC ZHS STOP
ZC ZHS
O
G
E ZLS
MHS DRAWING PREVIOUSLY
C
CLOSED OPEN C B ISSUED AS
NOTE 7, 13 CLOSE
ZLL ZY
+
ZLL UC
ZC ZHS
T76-A-PP-250600-005
C S O DETAIL 12
START
G
ERROR CLOSED NOTE 7 P&ID SYMBOL
C MHS
MHS LEGEND
ZA DE ZLL A DETAIL 12
PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
ZXY C SPECIFICATION SAES-L-105
+

ERROR
M AC/AFO -AIR TO CLOSE/
AIR FAILURE OPEN
VE
VS
-VIBRATION ELEMENT
-VIBRATION SWITCH
CLOSE VENT ZY COMMON FAULT AC/AFS -AIR TO CLOSE/AIR VT
+ PROCESS LINE -VIBRATION TRANSMITTER
FAILURE STEADY
ZHS SMART ZA A XL -PILOT LIGHT

POSITIONER IAS
E
S MA M INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
D AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
INSTRUMENT
FAILURE STEADY
POSITION ELECTRICAL LINE
DE ZY AOV -AIR OPERATED VALVE DATA LOGGER POINT
F-FLOW P-PRESS.
ZXI
+
S

INPUTS
AT -ANALYZER TRANSMITTER
B L-LEVEL T-TEMP.
E DETAIL 12 DT -DENSITY TRANSMITTER
CLOSE X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
LV PUMP MOTOR WITH PLC CONTROL FC - FLOW CONTROLLER
LOCAL PANEL
ZHS DE
SPECTACLE FV -FLOW CONTROL VALVE
MOUNTED INSTR.

D NOTE 9 , 11 PLATE-OPEN FCV -FLOW CONTROL VALVE


BOARD MOUNTED
(SELF-ACTUATED) INSTRUMENT
SPECTACLE
VENT FE -FLOW ELEMENT
PLATE-CLOSED R/G
ZV NOTE 6 FG -FLOW SIGHT GLASS
STATUS LIGHTS
+
POSITION SMART LOCAL ELECTRICAL MOTOR CONTROL STATION GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER
ZXI POSITIONER GLOBE VALVE
PILOT LIGHT (DO NOT
FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
LOCAL/OFF NOTE 4 C FM -FLOW METER
PDZT IAS CHECK VALVE
MOTOR STATUS
/REMOTE FO -RESTRICTION ORIFICE
PILOT LIGHT
H/O/A START STOP RUNNING STOPPED PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
ZXY C BALL VALVE
FR -FLOW RECORDER
ML LOCAL MOUNTED
FT -FLOW TRANSMITTER
PDZAH ZC
+
INSTRUMENT
DOUBLE DISC FY -FLOW RELAY
GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
HLS ZC ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
C
PDZI C LA -LEVEL ALARM
LV -LEVEL CONTROL VALVE RACK MOUNTED
CSC PRESS.RELIEF VALVE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
3" C NOTE 6 (SELF-ACTUATED)
ZV LG -LEVEL GAUGE GLASS ELECTRICAL
+

LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED


C HLA
VACUUM RELIEF VALVE LI -LEVEL INDICATOR
LR -LEVEL RECORDER INSTRUMENT
LOCAL/REMOTE -LEVEL SWITCH AIR SUPPLY REQUIRED
LS
DETAIL 10 OR 10A (SEE NOTE 13) STATUS
M MOTOR OPERATED
NOT CLOSED DETAIL 14 VALVE LT -LEVEL TRANSMITTER
SMART ZV VALVE - SPRING RETURN -LEVEL TRANSDUCER
H
SMART ZV VALVE - SPRING RETURN-2 SOLENOIDS MXL
LTD HIGH LOW
-WITH EQUALISATION BYPASS ML -MOTOR STATUS LIGHT L
-MOTOR OPERATED VALVE
INCLUDING HLS AND PDZT P
PISTON OPERATED
MOV
NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
C
PC -PRESSURE CONTROLLER FF
FOUNDATION
RUNNING/STOPPED CONTROL VALVE PV -PRESS. CONTROL VALVE
FIELDBUS INSTRUMENT
DETAIL 10 OR 10A PCV -PRESS. CONTROL VALVE

P&ID SYMBOL ML (SELF ACTUATED)


P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
ZC S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM

SPEED SETPOINT INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL


PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
MCC VFD STOP PG -PRESSURE GAUGE
(DCS) DISTRIBUTED CONTROL
PI -PRESSURE INDICATOR
DETAIL 10 OR 10A MHS PIC -PRESS. INDICATOR CONTROLLER
SYSTEM, OPERATOR INACCESSIBLE
IN FIELD
PR -PRESSURE RECORDER
B MHS PS -PRESSURE SWITCH
DISTRIBUTED CONTROL
ZV DETAIL 14 PT -PRESSURE TRANSMITTER
PX -PRESSURE POINT INTERCONNECTING LOGIC
+
P&ID SYMBOL PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
START DETAIL 15 PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
MHS P&ID SYMBOL RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
SI -SPEED INDICATOR CONTROLLER, NORMALLY
A DETAIL 15 SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
ZC TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
DETAIL 14
M TV
TCV
-TEMP. CONTROL VALVE
-TEMP. CONTROL VALVE
(PLC) PROGRAMMABLE LOGIC
CONTROLLER FUNCTION,
PDZT COMMON FAULT IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY
STEAM TRAP DISPLAYED ON CRT
TE -TEMP. ELEMENT
C ZV MA TSO -TIGHT SHUT OFF TG
HLS + -THERMOMETER LOCAL DCS OR AUXILIARY
+ S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
DETAIL 15 M S -DRAIN TO TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
TR -TEMP. RECORDER
PRESSURE SEWER
FAN MOTOR WITH VARIABLE SPEED, DCS CONTROL TS -TEMP. SWITCH
(PLC) PROGRAMMABLE LOGIC
CONTROLLER I/O POINT
OWS -OILY WATER SEWER TT -TEMP. TRANSMITTER
NOTE 9 , 11 D -DRAIN TTD -TEMP. TRANSDUCER
NORMALLY INACCESSIBLE
BY OPERATOR
V -VENT TW -THERMOWELL

ON ACTUATOR NOTE 1
LOCAL ELECTRICAL MOTOR CONTROL STATION LOCAL ELECTRICAL MOTOR CONTROL STATION REFERENCE DRAWINGS
LOCAL/REMOTE
STATUS LETTER IDENTIFICATION OF LINES AD-036204
LOCAL/OFF NOTE 4 C LOCAL/OFF LOCAL/OFF NOTE 4, 5 C
PIPING SYMBOLS AB-036227
/REMOTE REMOTE MXL /REMOTE
EQUIPMENT SYMBOLS AB-036305
HOA START STOP RUNNING STOPPED MHS H/O/A START LOW START HIGH STOP RUNNING LOW RUNNING HIGH STOPPED
INSTRUMENT SYMBOLS AC-036950
D PIPING LAYOUT INDEX

STOP PLOT PLAN


PROCESS FLOW DIAGRAM
STOP MHS
HYDROSTATIC TEST DIAGRAM
MHS G
DRAWING CONTROL FOR J.O.
C INSTRUMENT INSTALLATION SCHEDULES

CLOSE RUNNING HIGH


CLOSE MHS ML
MHS F C C 05 29 20
LOCAL/REMOTE
STATUS B START HIGH B 02 14 20

MXL OPEN MHS A 09 24 19

OPEN MHS C REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY

MHS E RUNNING LOW REVISION VALIDATION


A ML THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
OPEN A REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
OPEN
SPEED SETPOINT
MXL MLL LOCAL/REMOTE STATUS
MCC VFD O O MXL DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
RUNNING/STOPPED ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
ML CLOSED CLOSED MCC STOP 05/29/20 05/29/20

MLS MLS MXT MXL MLL MHS REV.NO. DATE REVISION DESCRIPTION DSN

STOP DETAIL 16 C O C C B MHS


C 05/29/20 ISSUED FOR REVIEW 9433
MHS P&ID SYMBOL JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
B
MHS
DETAIL 16 POSITION START LOW
10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED
DETAIL 17 DETAIL 18
SAUDI ARABIAN OIL COMPANY
M
MXI P&ID SYMBOL MHS P&ID SYMBOL
M COMMON FAULT
A DETAIL 18 DRAWING TYPE
MA MHS PIPING & INSTRUMENTATION DIAGRAM PID
DETAIL 17
M M INSTRUMENT SYMBOLS AND LEGEND
MOV ERROR COMMON FAULT
+

MA MOV
+
MA COMMON AREA
M

DETAIL 16 DETAIL 18 NOTE 5 M TANAJIB SAUDI ARABIA


DETAIL 17 PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
LV PUMP OR COMPRESSOR MOTOR WITH SPEED AND DCS CONTROL FAN MOTOR TWO SPEED WITH DCS CONTROL
MOTOR OPERATED VALVE PLC CONTROL
NOTE 9, 10, 11 NOTE 9 , 11 T80 A CA-033800 005 C
Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
NOTE CONT'D.:
DETAIL A1 DETAIL A2 DETAIL A3 1. DCS INDICATOR SHALL ALWAYS SHOW RANGE AND COMPONENT
11. ISOLATION VALVE ARRANGEMENT SHALL MEET OR EXCEED THE NAME (TO BE SHOWN AS DETAIL C1 AND C2 ON P&ID). DETAIL
REQUIREMENTS OF THE ASSOCIATED PROCESS PIPING CLASS. TYPE A1 TO B4 TO BE INDICATED AT THE ANALYZER CONNECTION
THIS SHALL INCLUDE THE REQUIREMENT, IF ANY, OF DOUBLE ON THE P&ID.
BLOCK AND BLEED REQUIRED BY THE PIPING CLASS. 2. TYPICALLY, BREAK FLANGES SHALL BE LINE SIZE.
12. SAMPLE PROBE VALVE MAY BE 3/4" IF REQUIRED BY CLASS BUT 3. TYPICALLY 2" OR 3" BRANCH SIZE DEPENDING ON SELECTED
AI GENERALLY THE SMALLEST PERMITTED (1/2") IS USUALLY BEST ANALYZER. SOME APPPLICATIONS ON LARGE LINES MAY
FOR SAMPLING. REQUIRE ISOLATION AND BYPASS VALVES
13. SUFFIX 'A'. 'B' ETC. TO BE APPLICABLE AS PER NUMBER OF 4. TYPICALLY 2" CONNECTION SIZE OR LARGER AS REQUIRED BY
COMPONENTS / VARIABLES BEING ANALYZED. THE APPLICATION. THE REQUIREMENT FOR FULL-BORE BALL
VALVES DEPENDS ON THE MAINTENANCE REQUIREMENT FOR
AI AI AT AI AI AI THE ANALYZER. CONNECTION SHALL BE IN THE SIDE OF THE
PIPE. NOZZLE ALIGNMENT TO BE WITHIN 2 DEGREES.
5. FOR CONDUCTIVITY, pH AND DISSOLVED OXYGEN THAT ARE
IN-SITU BUT NOT RETRACTABLE, USE DETAIL A4. FF TYPE
TRANSMITTER WILL APPLY. TO BE CONFIRMED LATER.
6. SAMPLE PROBES APPLY ONLY ON PROCESS LINES WITH SIZES
AT AT AE AT AT AT ABOVE 4". SAMPLE TAKE-OFF SHALL BE AS PER DETAIL B3 FOR
LINES 3" AND LESS.
7. TRANSMITTER DETAIL CAN BE REPLACED WITH DETAILS C1
AND C2 AS APPLICABLE.
8. THE UTILITY REQUIREMENTS TO BE DEVELOPED LATER
FOR EACH ANALYZER, VERIFY THESE WITH THE SUPPLIER OF
THE ANALYZER SYSTEM, AND THE REQUIREMENT
TO BE SHOWN ON THE RESPECTIVE P&ID.
DETAIL A1 DETAIL A2 DETAIL A3 9. EXTRACTIVE TYPE ANALYZERS MEASURING HYDROCARBON
LIQUIDS WILL MOST LIKELY REQUIRE A SAMPLE RECOVERY
SYSTEM RETURN CONNECTION IN ADDITION TO THE SAMPLE
DETAIL P&ID DETAIL P&ID DETAIL P&ID
RETURN. THIS SHALL BE SHOWN.
10. MODBUS DETAIL ONLY SHOWS THE CRITICAL SIGNALS AND
DOES NOT INCLUDE ALL THE DIAGNOSTICS SIGNALS THAT MAY
BE AVAILABLE OR USED.

SPOOL TYPE ANALYZER WITH HEAD-MOUNT SPOOL TYPE ANALYZER WITH REMOTE-MOUNT BRANCH TYPE ANALYZER WITH HEAD-MOUNT
ELECTRONICS (BS&W, IN-LINE DENSITY, ELECTRONICS (IN-LINE DENSITY, ELECTRONICS (OIL_IN_WATER, IN-LINE DENSITY, LEGEND
TORROIDAL CONDUCTIVITY) NOTE 1, 2, 8 TORROIDAL CONDUCTIVITY) NOTE 1, 2, 8 IN-SITU CEMS AND ZIRCONIUM OXIDE ANALYZERS) NOTE 1, 3, 8 PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS -VIBRATION SWITCH
AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
PROCESS LINE
FAILURE STEADY XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
DETAIL A4 DETAIL A5 DETAIL B1 AO/AFS -AIR TO OPEN/AIR ZV
INSTRUMENT -SAFETY SHUTDOWN VALVE
FAILURE STEADY
ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
DT -DENSITY TRANSMITTER
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
AI SPECTACLE FV -FLOW CONTROL VALVE
MOUNTED INSTR.

PLATE-OPEN FCV -FLOW CONTROL VALVE


BOARD MOUNTED
FF SPECTACLE
(SELF-ACTUATED) INSTRUMENT
AT AI AT AI PLATE-CLOSED
FE -FLOW ELEMENT
R/G
FG -FLOW SIGHT GLASS
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
AT AI AT AI AI GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
INST FM -FLOW METER
CHECK VALVE
FO -RESTRICTION ORIFICE MOTOR STATUS
PILOT LIGHT
PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
AE FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
FF DOUBLE DISC
PIPING GATE VALVE
FY -FLOW RELAY
AE AT AT HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
INST ANGLE VALVE HS -HAND SWITCH LOCAL PANEL

2" PIPING LA -LEVEL ALARM


LV -LEVEL CONTROL VALVE RACK MOUNTED
AE PRESS.RELIEF VALVE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
INST (SELF-ACTUATED)
LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
AE
VACUUM RELIEF VALVE LI -LEVEL INDICATOR
LR -LEVEL RECORDER INSTRUMENT
DETAIL A4 DETAIL A5 DETAIL B1 M MOTOR OPERATED LS -LEVEL SWITCH AIR SUPPLY REQUIRED

LT -LEVEL TRANSMITTER
VALVE H
LTD -LEVEL TRANSDUCER HIGH LOW
ML -MOTOR STATUS LIGHT L
DETAIL P&ID DETAIL P&ID DETAIL P&ID P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
PC -PRESSURE CONTROLLER FF
CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT

(SELF ACTUATED)
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
BRANCH TYPE ANALYZER WITH REMOTE-MOUNT P

CROSS-PIPE ANALYZER (DUST/ CAPACITY, TUNEABLE RETRACTABLE SENSOR TYPE ANALYZER (CONDUCTIVITY, CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
ELECTRONICS (IN-LINE DENSITY, IN-SITU CEMS, WITH POSITIONER
DIODE LAZER TYPE) NOTE 1, 4, 8, 11 PH, DISSOLVED OXYGEN TYPE) NOTE 1, 5, 8, 11 PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
ZIRCONIUM OXIDE ANALYZERS) NOTE 1, 3, 5, 8 S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
DETAIL B2 DETAIL B3 DETAIL B4 PIC -PRESS. INDICATOR CONTROLLER
IN FIELD
PR -PRESSURE RECORDER
PS -PRESSURE SWITCH
PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
PX -PRESSURE POINT INTERCONNECTING LOGIC
PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
FF SI -SPEED INDICATOR CONTROLLER, NORMALLY
AT AI AI SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
AI TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY

AI AI AI DRAWING PREVIOUSLY ISSUED AS TSO


STEAM TRAP
-TIGHT SHUT OFF
TE
TG
-TEMP. ELEMENT DISPLAYED ON CRT

-THERMOMETER
T76-A-PP-250600-006
LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH
AE AT DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
AT PRESSURE SEWER TR -TEMP. RECORDER
(PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
FF D -DRAIN TTD -TEMP. TRANSDUCER
AT INST AT AE AT
BY OPERATOR
V -VENT TW -THERMOWELL
1/2" 1/2"
PROBE
3/4" 1/2" 3/4" 3/4"
INST PIPING INST REFERENCE DRAWINGS
2" PIPING 2" PIPING LETTER IDENTIFICATION OF LINES AD-036204
PIPING SYMBOLS AB-036227
RETURN / DRAIN RETURN / DRAIN / FLARE RETURN / DRAIN / FLARE
EQUIPMENT SYMBOLS AB-036305

DETAIL B2 DETAIL B3 DETAIL B4 INSTRUMENT SYMBOLS AC-036950


PIPING LAYOUT INDEX
PLOT PLAN
DETAIL P&ID DETAIL P&ID DETAIL P&ID PROCESS FLOW DIAGRAM
HYDROSTATIC TEST DIAGRAM
DRAWING CONTROL FOR J.O.
INSTRUMENT INSTALLATION SCHEDULES

EXTRACTIVE TYPE ANALYZER WITH REMOTE EXTRACTIVE TYPE ANALYZER WITH HEAD MOUNT EXTRACTIVE TYPE ANALYZER WITH HEAD MOUNT
MOUNT TRANSMITTER (MOISTURE, CONDUCTIVITY, TRANSMITTER AND NO SAMPLE PROBE (MOISTURE, TRANSMITTER (MOISTURE, IR, UV, GC, PHYSICAL PROPERTY,
PH, DISSOLVED OXYGEN TYPE) NOTE 1, 5, 6, 8, 9, 11, 12 IR, UV, GC, PHYSICAL PROPERTY, OXYGEN TYPE) NOTE 1, 6, 7, 8, 9, 11, 12 OXYGEN TYPE) NOTE 1, 6, 7, 8, 9, 11, 12 C 05 29 20

B 02 14 20

A 09 24 19

REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY

DETAIL C1 DETAIL C2 REVISION VALIDATION


THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER


VARIABLE 1 VARIABLE 2 VARIABLE 3 VARIABLE 1 VARIABLE 2 VARIABLE 3 (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
RANGE RANGE RANGE FAULT RANGE RANGE RANGE FAULT ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
AI AI AI AA AI AI AI AA 05/29/20 05/29/20

A B C A B C REV.NO. DATE REVISION DESCRIPTION DSN


C 05/29/20 ISSUED FOR REVIEW 9434

JOB ORDER/EWO NO.


THIS REVISION IS NOT TO BE USED FOR
10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY


DRAWING TYPE
AT AT
PIPING & INSTRUMENTATION DIAGRAM PID
ANALYZER TYPICAL DETAILS
COMMON AREA
EXTRACTIVE TYPE ELECTRONIC CONTROLLER TYPE TANAJIB SAUDI ARABIA
EXTRACTIVE TYPE ELECTRONIC CONTROLLER TYPE
ANALYZER WITH ONE OR MORE MODBUS TCP/IP
ANALYZER WITH ONE OR MORE HARDWIRED SIGNALS PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
SIGNALS AND FAULT ALARM (GC AND OTHER TYPES,
AND FAULT ALARM (MOISUTRE, IR, UV, PHYSICAL
SUBJECT TO AVAILABILITY OF A MODBUS INTERFACE
PROPERTY, OXYGEN TYPE) NOTE 7, 13
FROM THE ANALYZER) NOTE 7, 10, 13
T80 A CA-033800 006 C
Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
SAMPLE CONNECTION TYPE 1 SAMPLE CONNECTION TYPE 2 SAMPLE CONNECTION TYPE 3 1. EYE WASH BATH AS PER SAES-B-069 TO BE PROVIDED NEAR
SAMPLE POINT.
COLD LIQUID HYDROCARBONS SAMPLE POINT HOT LIQUID HYDROCARBONS SAMPLE POINT (>140°F) COLD GAS SAMPLE / COLD 2. PIPING, INSULATION, TRACING SPEC WILL FOLLOW THE
(NON-FLASHING) (<140°F) PROCESS PIPING SPEC.
FLASHING LIQUID (< 140°F) 3. PIPING,SPEC WILL FOLLOW THE DESTINATION PIPING SPEC.
4. REQUIREMENT OF SEAL, IF ANY, SHALL BE AS PER MATERIAL
HANDLED.
5. FLARE TYPE SHALL BE SAME AS FOR THE MAIN PROCESS LINE.
2" 2" 2" 2" 6. THIS P&ID SHALL BE FULLY DEVELOPED LATER.
LINE "B" LINE "B" LINE "B" LINE "B" 7. SAMPLING COOLER DETAIL SHALL BE ACCORDING TO AOC
CDS CDS STANDARD DRAWING AB-036033-001. THE COOLING BOX SHALL
NOTE 2 NOTE 3 NOTE 2 NOTE 3
NOTE 2 NOTE 3 BE MADE WITH SS OR INTERNALLY COVERED WITH EPOXY.

LINE "E" LINE "B"

LINE "B"
MIN.
LINE "A" LINE "B" THE COIL SHALL BE SS.
NOTE 5 8. REPRESENTATIVE VALVE ARRANGEMENT SHOWN ONLY.
2" NOTE 2 2" 1"
BY VENDOR BY CONTRACTOR INTAKE TOP FOR REQUIREMENT OF DOUBLE BLOCK & BLEED (DBB) v/s SINGLE
C BLOCK & BLEED (SBB) SHALL BE IN ACCORDANCE WITH

LINE "E"
PI NOTE 22 SIDE HOUR 3, 12, 9
ISOLATION PHILOSOPHY (DOC. NO. T80-A-PP-060205).
2" 2" TO FLARE
PI 9. SAMPLING BOMB SHALL BE 300 CC EVACUATED
(VACUUM) OR NITROGEN PURGED SAMPLE CONTAINER.
PROCESS LINE 10. PISTON TYPE SAMPLE VALVE (STRAHMAN OR EQUIVALENT).
NOTE 4
11. SAMPLE VALVE TO BE CONNECTED FROM THE TOP, IF PROCESS

PROCESS LINE

PROCESS LINE
LINE "A" MIN. NOTE 4 LINE "A" MIN.
LINE IS HORIZONTAL. SAMPLE VALVE TO BE ANGLED FOR FREE
1"x1/2" DRAINING, IF PROCESS LINE IS VERTICAL.
6"x2" 6"x1/2" 1/2" 1"x1/2" 6"x2" 2"x1/2" 1/2" 1"x1/2" 1" 12. VALVE PISTON TO PROTRUDE INTO THE PROCESS LINE WHEN
MIN. 1.8m MIN. 1.8m 1" 1/2" THE VALVE IS CLOSED.
NOTE 2 1"
NOTE 2 13. PROCESS VENTS AND DRAINS SHALL NOT BE USED AS
1" 1"
INTAKE SIDE INTAKE SIDE 1"x1/2" 1"X1"-THDD SAMPLE CONNECTIONS.
HOUR 3, 9 14. TRAPPED AIR OR VAPORS SHALL BE REMOVED
HOUR 3, 9 COUPLING FOLLOWING THE INSTALLATION OF THE EQUIPMENT.
1/2" 15. SAMPLE DRAIN TO BE ROUTED TO OWS OR AMINE / MEG /
BY VENDOR BY CONTRACTOR CAUSTIC SUMP.
NOTE 2 NOTE 3 C LINE "D"
NOTE 22 16. ISOLATION VALVE TYPE SHALL BE AS PER PROJECT VALVE
? SELECTION PHILOSOPHY.
2" 2" BY CONTRACTOR BY VENDOR
17. DEWAR FLASK OR SIMILAR.
6"
LINE "F" 1" C PI
LINE "C"
MIN.

2" 2" LEGEND


LINE "D" UW
NOTE 4, 21 PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
2" 1/2" 6"x3/4" AIR FAILURE OPEN VS -VIBRATION SWITCH
AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
PROCESS LINE
FAILURE STEADY XL -PILOT LIGHT
NOTE 2 INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR LINE AIR FAILURE CLOSE XS
TI NOTE 7 -LIMIT SWITCH

LINE "A"
SS INSTRUMENT
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
FAILURE STEADY
ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
SAMPLING BOMB IN VERTICAL F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
MIN. L-LEVEL T-TEMP.
11" MIN.

NOTE 9 DT -DENSITY TRANSMITTER


X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER
2" LINE "C" ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
NOTE 2 SPECTACLE
FC - FLOW CONTROLLER
MOUNTED INSTR.
FV -FLOW CONTROL VALVE
NOTE 3 3"x3/4" 3"x3/4" PLATE-OPEN FCV -FLOW CONTROL VALVE
BOARD MOUNTED
(SELF-ACTUATED)
NOTE 2 SS SPECTACLE FE -FLOW ELEMENT
INSTRUMENT

1/2" SP PLATE-CLOSED FG -FLOW SIGHT GLASS


R/G
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
NOTE 3 GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)

CHECK VALVE FM -FLOW METER


FO -RESTRICTION ORIFICE MOTOR STATUS
PILOT LIGHT
PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
FR -FLOW RECORDER
? BALL VALVE
FT -FLOW TRANSMITTER
ML LOCAL MOUNTED
INSTRUMENT
DOUBLE DISC FY -FLOW RELAY

11" MIN.
METALLIC HOSE GATE VALVE

NOTE 2
HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND

1"X1"-THDD (BOTH ENDS BOTTLE) ANGLE VALVE HS -HAND SWITCH LOCAL PANEL

3/4" FURNISHED WITH SAMPLE BOTTLE LA -LEVEL ALARM


LV -LEVEL CONTROL VALVE
COUPLING PRESS.RELIEF VALVE -LEVEL CONTROL VALVE
RACK MOUNTED
OWS LCV (OR BACK OF PANEL)
(SELF-ACTUATED)

NOTE 3
LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
1/2" VACUUM RELIEF VALVE LI -LEVEL INDICATOR
BY VENDOR BY CONTRACTOR LR -LEVEL RECORDER INSTRUMENT
NOTE 3
NOTE 22 M MOTOR OPERATED LS -LEVEL SWITCH AIR SUPPLY REQUIRED
1-1/2" VALVE LT -LEVEL TRANSMITTER
H
LTD -LEVEL TRANSDUCER HIGH LOW
NOTE 3 C ML -MOTOR STATUS LIGHT L
P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
PC -PRESSURE CONTROLLER FF
CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT

(SELF ACTUATED)
SHORTCUT REPRESENTATION TO BE SHOWN ON P&ID OWS SHORTCUT REPRESENTATION TO BE SHOWN ON P&ID SHORTCUT REPRESENTATION TO BE SHOWN ON P&ID P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
SC-1 SC-2 SC-3 S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
IN FIELD
PR -PRESSURE RECORDER
PS -PRESSURE SWITCH
SAMPLE CONNECTION TYPE 5 SAMPLE CONNECTION TYPE 6 NOTE 22 C PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL

SAMPLE CONNECTION TYPE 4 PX -PRESSURE POINT INTERCONNECTING LOGIC


ACID GAS / HAZARDOUS FLUID (>140°F) GAS WITH SULFUR VAPOUR OR LIQUID SULFUR PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
NON HAZARDOUS LIQUID/CHEMICAL SAMPLE POINT PZV
RTD
-PRESSURE RELIEF VALVE
-RESIST. TEMP. DETECTOR
OR SEQUENTIAL FUNCTIONS

NOTE CONT'D.: SI -SPEED INDICATOR


(PLC) PROGRAMMABLE LOGIC
CONTROLLER, NORMALLY
SS -SPEED SWITCH
18. VAPOUR SAMPLE CONNECTS THROUGH TC -TEMP. CONTROLLER
INACCESSIBLE OR BEHIND THE
PANEL DEVICE OR FUNCTIONS

1"
DRYER SECTION. TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
19. LIQUID SAMPLE COLLECTED DIRECTLY IBT -INVERTED BUCKET
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
CAN BE NORMALLY
NOTE 8 INTO FLASK. STEAM TRAP
(SELF-ACTUATED)
DISPLAYED ON CRT
TE -TEMP. ELEMENT
20. PROVISION OF FLUSHING LINE TO BE TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
MIN. PROVIDED FOR CHEMICAL SAMPLE ONLY. S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
21. FOR DIAPHRAGM SEAL TYPE PG ISOLATION S -DRAIN TO TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR

PROCESS LINE VALVE TYPE SHALL BE 1" FLANGED TYPE PRESSURE SEWER TR -TEMP. RECORDER
(PLC) PROGRAMMABLE LOGIC
-TEMP. SWITCH
1" FOR 1" PIPE SIZE. OWS -OILY WATER SEWER
TS
CONTROLLER I/O POINT
TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
1" C 22. DETAIL CONFIGURATION TO BE CONFIRMED D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
PROCESS LINE LINE "F" BY VENDOR. V -VENT TW -THERMOWELL
UW

INTAKE ANY C REFERENCE DRAWINGS


1"x3/4"
MIN.

HOUR 3, OR 9 DRAWING PREVIOUSLY ISSUED AS LETTER IDENTIFICATION OF LINES AD-036204


PIPING SYMBOLS AB-036227
NOTE 2 T76-A-PP-250600-007 EQUIPMENT SYMBOLS AB-036305
TI NOTE 7
MIN.

SS INSTRUMENT SYMBOLS AC-036950


1"
1" PIPING LAYOUT INDEX
PLOT PLAN
UW LINE "A"
NOTE 20 PROCESS FLOW DIAGRAM
MIN.
HYDROSTATIC TEST DIAGRAM

NOTE 2, 10, 11, 12 DRAWING CONTROL FOR J.O.


3"x3/4" 3"x3/4"
INSTRUMENT INSTALLATION SCHEDULES
NOTE 2 SS
SP
1"
3/4" C 05 29 20

1-1/2" NOTE 3 B 02 14 20

3/4"x1/2" LINE "G" A 09 24 19

REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
1/2" REVISION VALIDATION
11" MIN.

THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION


REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
NOTE 9
COUPLING 1"x1/2" NOTE 2 NOTE 3
1"X1"-THDD LINE "A" LINE "B" DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
NOTE 5 (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
1" ? 1/2" 1" ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
05/29/20 05/29/20
1"x1/2"
METALLIC HOSE C
TO FLARE REV.NO. DATE REVISION DESCRIPTION DSN
COUPLING
1"X1"-THDD

NOTE 3 (BOTH ENDS BOTTLE) C 05/29/20 ISSUED FOR REVIEW 23095


FURNISHED WITH SAMPLE BOTTLE
BY VENDOR BY CONTRACTOR NOTE 17, 19 NOTE 17, 18 JOB ORDER/EWO NO.
SAMPLING BOMB THIS REVISION IS NOT TO BE USED FOR
NOTE 22 10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

NOTE 15 OWS SAUDI ARABIAN OIL COMPANY


DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
SHORTCUT REPRESENTATION TO BE SHOWN ON P&ID SHORTCUT REPRESENTATION TO BE SHOWN ON P&ID SHORTCUT REPRESENTATION TO BE SHOWN ON P&ID SAMPLE CONNECTION DETAILS
SC-4 SC-5 SC-6 COMMON AREA
TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 007 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
1. INSTRUMENT TAG NUMBER AND LINE NUMBER WILL BE
CONFIRMED.

SAMPLE CONNECTION LIST

NO. PLANT NO. TYPE P&ID SERVICE PROCESS LINE NO. PI TI DESTINATION REMARK

1 T76 SC-4 C CA-033801-002 POTABLE WATER 3"-DW-00001-1SD0W14 C - - OWS


C C

2 T76 SC-4 CA-033801-002 DRINKING WATER T76-D-0402A - - OWS

3 T76 SC-4 CA-033801-002 DRINKING WATER T76-D-0402B B - - OWS

4 T76 SC-4 CA-033801-002 DRINKING WATER RETURN 6"-DW-5019-1FE0W14 - - OWS

5 T76 SC-4 CA-033802-001 POTABLE WATER 12"-DW-00001-1LE0W14 C - - OWS

6 T76 SC-4 CA-033802-002 UTILITY WATER T76-D-0301A - - OWS

7 T76 SC-4 CA-033802-002 UTILITY WATER T76-D-0302B C - - OWS

8 T76 SC-4 CA-033806-003 OPEN LOOP COOLING WATER 60"-TW-00816-1CS2W01 C - - OWS

9 T76 SC-4 CA-033806-007 CLOSED LOOP COOLING WATER 56"-CWR-00207-1CS2W01 - - OWS LEGEND
PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
10 T74 SC-4 CA-033811-037 DEOILED WATER 12"-WW-00102-1LE0U01 - - OWS AIR FAILURE OPEN VS -VIBRATION SWITCH
AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
PROCESS LINE
FAILURE STEADY XL -PILOT LIGHT
-AIR TO OPEN/
11 T76 SC-4 CA-033816-001 FIREWATER T76-D-0201A C - - OWS INSTRUMENT AO/AFC
AIR FAILURE CLOSE
(NOT FOR MOTOR)
AIR LINE XS -LIMIT SWITCH
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
INSTRUMENT
FAILURE STEADY
ELECTRICAL LINE
12 T76 SC-4 CA-033816-001 FIREWATER T76-D-0201B - - OWS AOV -AIR OPERATED VALVE DATA LOGGER POINT
F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
DT -DENSITY TRANSMITTER
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
13 T76 SC-4 CA-033816-002 FIREWATER 20"-FW-5001-1CS2W13 - - OWS FC - FLOW CONTROLLER
LOCAL PANEL
SPECTACLE MOUNTED INSTR.
FV -FLOW CONTROL VALVE
PLATE-OPEN FCV -FLOW CONTROL VALVE
BOARD MOUNTED
14 T78 SC-4 CA-033811-005 DEOILED STORM WATER 8"-TW-00701-1LE0U01 - - OWS SPECTACLE
(SELF-ACTUATED) INSTRUMENT
FE -FLOW ELEMENT
PLATE-CLOSED FG -FLOW SIGHT GLASS
R/G
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
15 T74 SC-4 CA-033811-007 OILY WATER 18"-OW-00208-1LE0U01 C - - OWS FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)

CHECK VALVE FM -FLOW METER


FO -RESTRICTION ORIFICE MOTOR STATUS
16 T74 SC-4 CA-033811-007 SKIMMED OIL 6"-SPO-00358-1LE0U01 - - OWS PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
PILOT LIGHT

FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
17 T74 SC-4 CA-033811-007 DEOILED WATER 18"-WW-00104-1LE0U01 - - OWS DOUBLE DISC FY -FLOW RELAY
GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
LA -LEVEL ALARM
18 T74 SC-5 CA-033812-001 HP FLARE KO DRUM CONDENSATE T79-D-0701A - 0101 HP FLARE LV -LEVEL CONTROL VALVE RACK MOUNTED
PRESS.RELIEF VALVE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
(SELF-ACTUATED)
-LEVEL GAUGE GLASS
19 T74 SC-5 CA-033812-001 SOUR WATER T79-D-0701A - 0102 HP FLARE LG
-LEVEL INDICATOR CONTROLLER
ELECTRICAL
SUPPLY REQUIRED
LIC
VACUUM RELIEF VALVE LI -LEVEL INDICATOR
LR -LEVEL RECORDER INSTRUMENT
20 T74 SC-5 CA-033812-002 HP FLARE KO DRUM CONDENSATE T79-D-0701B - 0103 HP FLARE M MOTOR OPERATED LS -LEVEL SWITCH AIR SUPPLY REQUIRED

LT -LEVEL TRANSMITTER
VALVE H
LTD -LEVEL TRANSDUCER HIGH LOW
ML -MOTOR STATUS LIGHT L
21 T74 SC-5 CA-033812-002 SOUR WATER T79-D-0701B - 0104 HP FLARE P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
22 T74 SC-5 CA-033812-015 LP FLARE KO DRUM CONDENSATE T79-D-0704A - 0107 LP FLARE PC -PRESSURE CONTROLLER FF
FOUNDATION
CONTROL VALVE PV -PRESS. CONTROL VALVE
PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT

(SELF ACTUATED)
23 T74 SC-5 CA-033812-015 SOUR WATER T79-D-0704A - 0108 LP FLARE P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
INDICATOR CONTROLLER
24 T74 SC-5 CA-033812-016 LP FLARE KO DRUM CONDENSATE T79-D-0704B - 0109 LP FLARE S
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL
SYSTEM, OPERATOR ACCESSIBLE
IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
25 T74 SC-5 CA-033812-016 SOUR WATER T79-D-0704B C - 0110 LP FLARE PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
IN FIELD
26 T74 SC-5 CA-033812-025 LT FLARE KO DRUM CONDENSATE T79-D-0006A - 0111 LT FLARE PR -PRESSURE RECORDER
PS -PRESSURE SWITCH
PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
PX -PRESSURE POINT INTERCONNECTING LOGIC
27 T74 SC-5 CA-033812-026 LT FLARE KO DRUM CONDENSATE T79-D-0006B - 0112 LT FLARE PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
28 T74 SC-5 CA-033812-035 LP FLARE GAS 8"-LPF-00908-1CH2P02 - 0113 LP FLARE SI -SPEED INDICATOR CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
29 T74 SC-5 CA-033812-035 LP FLARE GAS 8"-LPF-00913-1CH2P02 - 0114 LP FLARE TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY
STEAM TRAP DISPLAYED ON CRT
TE -TEMP. ELEMENT
TSO -TIGHT SHUT OFF
30 T74 SC-5 CA-033812-003 HP FLARE KO DRUM CONDENSATE T79-D-0701C C - 0105 HP FLARE TG -THERMOMETER LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER
31 T74 SC-5 CA-033812-003 SOUR WATER T79-D-0701C - 0106 HP FLARE TS -TEMP. SWITCH
(PLC) PROGRAMMABLE LOGIC
CONTROLLER I/O POINT
OWS -OILY WATER SEWER TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL
32 T76 SC-4 CA-033802-001 POTABLE WATER 12"-DW-00001-1LE0W14 C - - OWS

REFERENCE DRAWINGS
33 T76 SC-4 CA-033806-002 OPEN LOOP COOLING WATER 60"-TW-00808-1CS2W01 - - OWS
LETTER IDENTIFICATION OF LINES AD-036204
PIPING SYMBOLS AB-036227
34 T76 SC-4 CA-033806-006 CLOSED LOOP COOLING WATER 56"-CWR-00201-1CS2W01 - - OWS EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950
SC-3 C PIPING LAYOUT INDEX
35 T76 CA-033808-004 INSTRUMENT AIR 6"-IA-00205-1CS1U01 0085 - VENT TO ATM SAMPLE CONNECTION TYPE IS SC-3 AND VENTING LINE CONNECTS TO ATM, NOT FLARE
SEE REMARK PLOT PLAN
PROCESS FLOW DIAGRAM
SC-3 C
36 T76 CA-033808-004 INSTRUMENT AIR 6"-IA-00206-1CS1U01 0086 C - VENT TO ATM SAMPLE CONNECTION TYPE IS SC-3 AND VENTING LINE CONNECTS TO ATM, NOT FLARE C HYDROSTATIC TEST DIAGRAM
SEE REMARK
DRAWING CONTROL FOR J.O.
SC-3 C INSTRUMENT INSTALLATION SCHEDULES
37 T76 CA-033808-004 INSTRUMENT AIR 6"-IA-00207-1CS1U01 0087 - VENT TO ATM SAMPLE CONNECTION TYPE IS SC-3 AND VENTING LINE CONNECTS TO ATM, NOT FLARE
SEE REMARK

38 T76 SC-4 CA-033803-001 DEMINERALIZED WATER 4"-DMW-00001-1SD0W01 - - OWS


C 05 29 20

B 02 14 20
39 T76 SC-4 CA-033803-001 DEMINERALIZED WATER T76-D-0401A - - OWS
A 09 24 19

REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
40 T76 SC-4 CA-033803-001 DEMINERALIZED WATER T76-D-0401B - - OWS
REVISION VALIDATION
THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
41 T76 SC-4 CA-033803-003 DEMINERALIZED WATER T76-D-0401C - - OWS REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
XX-XXXXX-XXXX-XXX
42 T76 SC-4 CA-033803-003 DEMINERALIZED WATER T76-D-0401D - - OWS
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
SC-3 ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
43 T76 CA-033808-001 COMPRESSED AIR T76-K-0701A 0081 - OWS SAMPLE CONNECTION TYPE IS SC-3 AND VENTING LINE CONNECTS TO ATM, NOT FLARE UCH HJL
SEE REMARK 05/29/20 05/29/20

REV.NO. DATE REVISION DESCRIPTION DSN


SC-3
44 T76 CA-033808-001 COMPRESSED AIR T76-K-0701B 0082 - OWS SAMPLE CONNECTION TYPE IS SC-3 AND VENTING LINE CONNECTS TO ATM, NOT FLARE
SEE REMARK C 05/29/20 ISSUED FOR REVIEW

JOB ORDER/EWO NO.


SC-3 THIS REVISION IS NOT TO BE USED FOR
45 T76
SEE REMARK
CA-033808-002 COMPRESSED AIR T76-K-0701C 0083 - OWS SAMPLE CONNECTION TYPE IS SC-3 AND VENTING LINE CONNECTS TO ATM, NOT FLARE 10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

46 T76
SC-3
CA-033808-002 COMPRESSED AIR T76-K-0701D 0084 - OWS SAMPLE CONNECTION TYPE IS SC-3 AND VENTING LINE CONNECTS TO ATM, NOT FLARE
C SAUDI ARABIAN OIL COMPANY
SEE REMARK DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
SAMPLE CONNECTION DETAILS LIST
COMMON AREA
TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 008 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:

NOTES
101. INTERFACE DETAILS TO BE CONFIRMED/FINALIZED LATER. 121. PZV SIZING, ORIFICE SELECTION, INLET/OUTLET LINE SIZING ARE PRELIMINARY. TO BE RECALCULATED
102. PACKAGE CONTENT IS INDICATIVE. DETAILS TO BE DEVELOPED LATER. AND RECONFIRMED LATER.
PACKAGE TO BE FULLY AUTOMATED AND HAVE THE ABILITY TO BE CONTROLLED FROM THE 122. PUMP MINIMUM RECYCLE LINE SIZES AS SHOWN ON P&IDS ARE ESTIMATED. TO BE RESIZED/CONFIRMED
CONTROL ROOM. DETAIL DESIGN TO INCLUDE SUITABLE ALLOWANCES FOR CONNECTIONS LATER.
TO DCS AND SAFEGUARDING SYSTEM TO FACILITATE THIS. 123. ZV EQUALISATION LINE ON GAS/VAPOUR SERVICE SHALL BE FREE DRAINING ON EITHER
103. ISBL UTILITY DISTRIBUTION P&ID'S TO BE DEVELOPED LATER. SIDE.
104. LINE SIZES ARE PRELIMINARY AND TO BE FINALYZED LATER. 124. SPADES FOR LINE SIZE LESS THAN OR EQUAL TO 12 INCH FOR ALL PIPING CLASSES SHALL BE INSTALLED
105. CONTROL VALVE ARE PRELIMINARY. BYPASS VALVE BODY SIZES SHOULD BE THE SAME AS IN A HORIZONTAL PIPE RUN WITH THE SPADE IN THE VERTICAL POSITION. SPADE SHOULD BE LOCATED
CONTROL VALVE BODY SIZES UNLESS THE BYPASS VALVE CV SIGNIFICANTLY EXCEEDS THE AT MINIMUM DISTANCE FROM EQUIPMENT, IF APPLICABLE. THIS DRAWING PREVIOUSLY ISSUED AS
CONTROL VALVE CV. VALVE TYPE SELECTION, SIZES AND FLANGE RATINGS ARE TO BE 125. ALL SEAL DETECTION LINES TO FLARE SHALL BE INDEPENDENT FROM ANY DE-PRESSURIZING LINE T76-A-PP-250600-008
FINALIZED LATER. FROM PUMP CASING (VENT/DRAIN) C

106. ALL PUMP INLET/OUTLET, VENT AND DRAIN FLANGE SIZES AND RATINGS TO BE CONFIRMED 126. FOR INSTRUMENTS CONNECTED TO ESD, ANY PIPING VALVE SHALL BE 'CSO.'
LATER. 127. IN GENERAL, THE MEASURED VARIABLE OF EACH ESD TRANSMITTER SHALL BE DISPLAYED ON THE DCS.
107. MOTOR DRIVER POWER SHALL BE VERIFIED AND TRIP/STATUS FUNCTIONALITY UPDATED LATER THIS IS NOT REPRESENTED ON THE P&IDS BUT SHALL BE IMPLEMENTED LATER.
ACCORDING TO SIZE OF MOTOR. 128. ZC NUMBERS ON THE P&IDS REPRESENT ESD INTERLOCKS THAT ARE DETAILED IN CAUSE AND EFFECT
108. POWER ACTUATION OF LARGE MANUAL VALVES WITH LINE SIZES ABOVE 12" AND <24" IS NOT DIAGRAMS. ZC-002 REPRESENTS A LEVEL 2 ESD LOGIC FOR TRAIN/UNIT SHUTDOWN. SEVERAL SIFS
CURRENTLY DEFINED AND SHALL BE REVIEWED LATER IN ACCORDANCE WITH (SAFETY INSTRUMENTED FUNCTIONS) MAY BE GROUPED WITHIN A SINGLE ZC. SEVERAL EQUIPMENT
SAES-L-108, SECTION 5.6.1 ISOLATION AND DE-PRESSURIZATION MAY BE GROUPED WITHIN A SINGLE LEVEL 3 ZC. SEVERAL ROTATING
109. WHEN GATE VALVES ARE USED AS BLOCK VALVES IN RELIEVING PATHS. THEY SHALL BE FULL EQUIPMENT PROTECTION MAY BE GROUPED WITHIN A SINGLE LEVEL 4 ZC.
PORT TYPE AND INSTALLED WITH THE STEM HORIZONTAL OR SLOPING AWAY FROM THE RELIEF 129. FOR UTILITIES INTERFACE AND STEAM TRAP DETAILS, REFER TO
VALVE. IN ACCORDANCE WITH SAES-J-600 PARA 9.4.3. STANDARD HOOK-UP DRAWINGS T80-A-CB-033800-021/022/023/024. LEGEND
110. UTILITY STATIONS NUMBER AND LOCATION TO BE DETERMINED LATER IN ACCORDANCE WITH SAES-L-310. 130. SAFETY SETTINGS MODIFIED "Z" IS USED TO IDENTIFY SIS - "SAFETY INSTRUMENT SYSTEM" ELEMENTS. PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
111. SAFETY SHOWER/EYE WASH ARE TYPICAL AND INDICATED ON RESPECTIVE SAFETY EQUIPMENT DRAWINGS. AC/AFO -AIR TO CLOSE/
AIR FAILURE OPEN
VE
VS
-VIBRATION ELEMENT
-VIBRATION SWITCH
LOCATION TO BE CONFIRMED LATER IN ACCORDANCE WITH SAES-B-069. PROCESS LINE AC/AFS -AIR TO CLOSE/AIR
FAILURE STEADY
VT
XL
-VIBRATION TRANSMITTER
-PILOT LIGHT
112. RUN OF LIQUID LINES, WHEN ISOLATED SHOULD BE DRAINED. THERMAL RELIEF REQUIREMENT, INSTRUMENT
AIR LINE
AO/AFC -AIR TO OPEN/
AIR FAILURE CLOSE XS
(NOT FOR MOTOR)
-LIMIT SWITCH
IF ANY, FOR LONG LINES TO BE ANALYSED AND PROVIDED LATER(IF REQUIRED). INSTRUMENT
AO/AFS -AIR TO OPEN/AIR
FAILURE STEADY
ZV -SAFETY SHUTDOWN VALVE

113. IN ACCORDANCE WITH SAES-L-108 PARA 6.3.2.A NON-SLAM SPRING ASSISTED TYPE CHECK VALVE SHALL ELECTRICAL LINE
AOV -AIR OPERATED VALVE DATA LOGGER POINT
F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
BE INSTALLED AT THE DISCHARGE OF ALL PUMPS AND COMPRESSORS. OTHER CHECK VALVE TYPES SHALL DT -DENSITY TRANSMITTER
L-LEVEL
X-MISC.
T-TEMP.
A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER
BE SPECIFICALLY APPROVED BY THE CHAIRMAN OF THE VALVES STANDARDS COMMITTEE.
ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
SPECTACLE MOUNTED INSTR.

114. ALL STEAM TRAP CONDENSATE RETURN AND CHEMICAL BD RETURN LINES SHALL JOIN THE RETURN PLATE-OPEN
FV
FCV
-FLOW CONTROL VALVE
-FLOW CONTROL VALVE
BOARD MOUNTED
HEADER AT 45° LATERALS. SPECTACLE FE
(SELF-ACTUATED)
-FLOW ELEMENT
INSTRUMENT

PLATE-CLOSED
115. FOR PACKAGED EQUIPMENT, VENDOR SHALL BE RESPONSIBLE TO TAG EVERY EQUIPMENT AND INSTRUMENTATION
R/G
FG -FLOW SIGHT GLASS
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
WITHIN THE PACKAGE AND PROVIDE DETAILED P&ID'S AND EQUIPMENT DATASHEETS AS PER SAES REQUIREMENTS GLOBE VALVE
FHTD
FIC
-FLOW MANUAL TRANSDUCER
-FLOW INDICATOR CONTROLLER
PILOT LIGHT (DO NOT
USE FOR MOTOR STATUS)

FOR ALL COMPONENTS WITHIN THE PACKAGE. ALSO, THESE P&IDS TO INCORPORATE ALL REQUIREMENT OF CHECK VALVE FM
FO
-FLOW METER
-RESTRICTION ORIFICE MOTOR STATUS

EMERGENCY ISOLATION AND OTHER VALVES AS PER ISOLATION, EMERGENCY SHUTDOWN AND OTHER RELEVANT PLUG VALVE FQI
FR
-FLOW TOTALIZER INDICATOR
-FLOW RECORDER
PILOT LIGHT

PHILOSOPHIES. BALL VALVE


DOUBLE DISC
FT -FLOW TRANSMITTER
ML LOCAL MOUNTED
INSTRUMENT
FY -FLOW RELAY
116. PUMP MECHANICAL SEAL AND API SEAL PLAN SELECTION SHALL BE DEVELOPED LATER. GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE
EPC CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING SEAL PLAN P&IDS. HS
LA
-HAND SWITCH
-LEVEL ALARM
LOCAL PANEL

117. SPLIT RANGE CONTROLLER TYPE DETAIL AS FOLLOWS : PRESS.RELIEF VALVE


LV
LCV
-LEVEL CONTROL VALVE
-LEVEL CONTROL VALVE
RACK MOUNTED
(OR BACK OF PANEL)
(SELF-ACTUATED)
LG -LEVEL GAUGE GLASS ELECTRICAL

DRAINS AND VENTS VACUUM RELIEF VALVE


LIC
LI
-LEVEL INDICATOR CONTROLLER
-LEVEL INDICATOR
SUPPLY REQUIRED

LR -LEVEL RECORDER INSTRUMENT


AIR SUPPLY REQUIRED
200. FINAL NUMBER AND LOCATION OF VENTS AND DRAINS TO BE CONFIRMED AND PROVICED M MOTOR OPERATED
VALVE
LS
LT
-LEVEL SWITCH
-LEVEL TRANSMITTER
H
IN ACCORDANCE WITH SAES-A-400 AND 401 AND TO REFLECT PIPING LAYOUT REQUIREMENTS LTD
ML
-LEVEL TRANSDUCER
-MOTOR STATUS LIGHT
HIGH
L
LOW

TYPE IMPLEMENTATION NOTES AS PER SAES-L-310. P


PISTON OPERATED
MOV
NA
-MOTOR OPERATED VALVE
-ANNUNCIATOR TWO PEN RECORDER
201. DRAINS AND VENTS FOR HYDROTEST, FLUSHING AND START-UP ARE TO BE SHOWN VALVE PB
PC
-PUSHBUTTON
-PRESSURE CONTROLLER FF

ON ISOMETRICS. CONTROL VALVE PV


PCV
-PRESS. CONTROL VALVE
-PRESS. CONTROL VALVE
FOUNDATION
FIELDBUS INSTRUMENT
100
202. ALL ATMOSPHERIC VENTS ON TANKS ARE TO HAVE STAINLESS STEEL SCREENS TO PREVENT BALL TYPE PDC
(SELF ACTUATED)
-PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
INGRESS BY SAND, BUGS AND BIRDS. VENT INSTALLATION ACCORDING TO ARAMCO
P

CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS


A WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
VALVE OPENING (%)

STANDARD DRAWING AD-036061 'TYPE 1'. S INDICATOR CONTROLLER


(DCS) DISTRIBUTED CONTROL
SYSTEM, OPERATOR ACCESSIBLE
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL
203. 'PIPED AWAY' VENTS AND DRAINS REQUIREMENTS FROM LEVEL INSTRUMENTS AND
IN CONTROL ROOM
INDICATOR SWITCH
A

(DCS) DISTRIBUTED CONTROL

BRIDLES ON TOXIC / LETHAL AND OTHER PROCESS RELATED SERVICES AS REQUIRED


B

PDT -PRESS. DIFF. TRANSMITTER


E

VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE


LV

PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM


CLOSED
LV

A ARE TO BE DEVELOPED IN ACCORDANCE WITH SAES-A-400, 401 AND 402.


VA

PG -PRESSURE GAUGE
VA

PI (DCS) DISTRIBUTED CONTROL


-PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
204. DRAIN TO BE PROVIDED BETWEEN NRV AND DOWNSTREAM ISOLATION. PIC
PR
-PRESS. INDICATOR CONTROLLER
-PRESSURE RECORDER
IN FIELD

205. CONNECTION OF DRAINS / VENTS TO CLOSED SYSTEM TO BE REVIEWED AND FINALISED LATER. PS
PT
-PRESSURE SWITCH
-PRESSURE TRANSMITTER DISTRIBUTED CONTROL

206. VENTS AND DRAINS SHOWN FOR EQUIPMENT ON THE P&IDS ARE TYPICAL REPRESENTATION. PX
PY
-PRESSURE POINT
-PRESS. COMPUTATION MOD.
INTERCONNECTING LOGIC
CONTROLLER WITH BINARY
FOR THE ACTUAL NUMBER AND SIZE OF VENTS & DRAINS FOR ANY PARTICULAR EQUIPMENT, PZV
RTD
-PRESSURE RELIEF VALVE
-RESIST. TEMP. DETECTOR
OR SEQUENTIAL FUNCTIONS
0
0 100
REFER TO THE EQUIPMENT DATASHEET. SI -SPEED INDICATOR
(PLC) PROGRAMMABLE LOGIC
CONTROLLER, NORMALLY
CONTROLLER OUTPUT (%) SS -SPEED SWITCH
207. FOR TYPICAL VENT AND DRAIN DETAILS, REFER TO PIPING GENERAL STANDARD (3)
INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE
T80-L-CE-034480-003. IBT -INVERTED BUCKET
TCV -TEMP. CONTROL VALVE
(PLC) PROGRAMMABLE LOGIC
CONTROLLER FUNCTION,
(SELF-ACTUATED) CAN BE NORMALLY
STEAM TRAP DISPLAYED ON CRT
TE -TEMP. ELEMENT
TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
100 S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER (PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
VALVE OPENING (%)

-OILY WATER SEWER CONTROLLER I/O POINT


OWS TT -TEMP. TRANSMITTER
A SMALL DEADBAND SHOULD BE D -DRAIN TTD -TEMP. TRANSDUCER
NORMALLY INACCESSIBLE
BY OPERATOR
PROVIDED BETWEEN ONE VALVE V -VENT TW -THERMOWELL
CLOSING AND THE OTHER VALVE
B
VA

OPENING. DEAD BAND MAY ALSO


LV
LV

BE REQUIRED ON CONTROLLER REFERENCE DRAWINGS


VA
E

B ERROR. (DEADBAND TO BE DECIDED


A

LETTER IDENTIFICATION OF LINES AD-036204


DURING DETAIL DESIGN) PIPING SYMBOLS AB-036227
EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950
PIPING LAYOUT INDEX
PLOT PLAN
0
PROCESS FLOW DIAGRAM
0 CONTROLLER OUTPUT (%) 100
HYDROSTATIC TEST DIAGRAM
DRAWING CONTROL FOR J.O.
INSTRUMENT INSTALLATION SCHEDULES

100 C 05 29 20

B 02 14 20
VALVE OPENING (%)

A 09 24 19

REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY

REVISION VALIDATION
THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
C VA
A
E LV
LV E
VA B
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
05/29/20 05/29/20
0
0 CONTROLLER OUTPUT (%) 100 REV.NO. DATE REVISION DESCRIPTION DSN
C 05/29/20 ISSUED FOR REVIEW 23599
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY


118. DELETED. DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
119. THERE IS PROVISION OF NITROGEN BACK-UP TO THE INSTRUMENT AIR HEADER.
POTENTIAL OF N2 BUILD UP AND INSTRUMENT AIR MUST NOT BE USED FOR ANY BREATHING APPARATUS. GENERAL NOTES
120. AIR FIN COOLERS ARE LOCATED ON MAIN PIPERACK UNLESS NOTED OTHERWISE ON RELEVANT P&IDS. COMMON AREA
FOR AIR COOLERS ON PIPERACK, POSSIBILITY OF HOT AIR RECIRCULATION SHALL BE CHECKED. TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 009 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
1. ZC-002 IS A LEVEL 2 SHUTDOWN LOGIC. THERE IS NO LEVEL 1
SHUTDOWN LOGIC FOR TGP.
2. ALL LEVEL 2 SHUTDOWN BUTTONS IN THE FIELD SHALL BE
LOCATED AT SAFE LOCATION, MINIMUM 50 FT AWAY
HORIZONTALLY FROM THE UNIT.
3. ZC-001 IS A MASTER BLOWDOWN CONTROLLER LOGIC WHICH
T70-00 T70-01 T70-02 T70-03 T70-04 T70-05 T70-06 T70-06 T70-06 T70-07 PREVENTS OVERLOADING OF THE FLARE IN AN EVENT OF
HZA HZA HZA HZA HZA HZA HZA HZA HZA HZA MULTIPLE LEVEL 2 EMERGENCY DEPRESSURIZATION INITIATION
0002 0002 0002 0002 0002 0002 1002 2002 3002 0002 BY OPERATOR IN CLOSE SUCCESSION. ZC-001 PREVENTS
OVERLOADING THE FLARE BY DELAYING THE TRAINWIDE /
LEVEL 2 EMERGENCY DEPRESSURIZATION UNTIL IT IS SAFE TO
COMMENCE THE DEPRESSURIZATION SEQUENCE. ZC-001
T70-00 T70-01 T70-02 T70-03 T70-04 T70-05 T70-06 T70-06 T70-06 T70-07 PRIORITISES TRAIN DEPRESSURIZATION BASED ON CRITICALITY
ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC
AND CORRESPONDING FLARE LOADS. ZC-001 ALLOWS
002 002 002 002 002 002 002 002 002 002 SIMULTANEOUS EMERGENCY DEPRESSURIZATION OF MULTIPLE
TRAINS AS LONG AS IT DOES NOT BREACH THE FLARE DESIGN
CAPACITY.
T70-00 T70-00 T70-00 T70-01 T70-01 T70-01 T70-01 T70-02 T70-02 T70-02 T70-02 T70-03 T70-03 T70-03 T70-03 T70-04 T70-04 T70-04 T70-04 T70-05 T70-05 T70-05 T70-06 T70-06 T70-06 T70-06 T70-06 T70-06 T70-06 T70-06 T70-06 T70-06 T70-06 T70-06 T70-07 T70-07 T70-07 T70-07 4. MASTER BLOWDOWN CONTROLLER ZC-001 LOGIC TO BE
HS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS DEVELOPED LATER .
0002 0002 A 0002 B 0002 0002 C 0002 A 0002 B 0002 0002 C 0002 A 0002 B 0002 0002 C 0002 A 0002 B 0002 0002 C 0002 A 0002 B 0002 0002 A 0002 B 1002 1002 C 1002 A 1002 B 2002 2002 C 2002 A 2002 B 3002 3002 C 3002 A 3002 B 0002 0002 C 0002 A 0002 B
5. LEVEL 2 EMERGENCY DEPRESSURIZATION STATUS DISPLAYED
AS BELOW.
RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN NO LAMP : DEPRESSURIZATION NOT REQUESTED BY
DEPRESSURIZE DEPRESSURIZE DEPRESSURIZE DEPRESSURIZE DEPRESSURIZE DEPRESSURIZE DEPRESSURIZE DEPRESSURIZE OPERATOR
BLINKING LAMP : DEPRESSURIZATION AWAITED, DELAYED BY
ZC-001
T70- INLET FACILITIES CONTINUOUS LAMP : DEPRESSURIZATION REQUEST APPROVED
LEVEL 2 AREA SHUTDOWN BY ZC-001
AND DEPRESSURIZATION SWITCHES

DRAWING PREVIOUSLY ISSUED AS


T76-A-PP-250600-010

LEGEND
PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
T71-10 T71-11 T71-12 T71-13 T72-21 T72-22 T72-23 SPECIFICATION SAES-L-105
HZA HZA HZA HZA HZA HZA HZA AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS
0002 1002 2002 3002 1002 2002 3002 AC/AFS -AIR TO CLOSE/AIR
-VIBRATION SWITCH
PROCESS LINE VT -VIBRATION TRANSMITTER
FAILURE STEADY XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
T71-10 T71-11 T71-12 T71-13 T72-21 T72-22 T72-23 INSTRUMENT
FAILURE STEADY
ZC ZC ZC ZC ZC ZC ZC ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
002 002 002 002 002 002 002 F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
DT -DENSITY TRANSMITTER
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
SPECTACLE MOUNTED INSTR.
T71-10 T71-10 T71-10 T71-10 T71-11 T71-11 T71-11 T71-11 T71-12 T71-12 T71-12 T71-12 T71-13 T71-13 T71-13 T71-13 T72-21 T72-21 T72-21 T72-21 T72-22 T72-22 T72-22 T72-22 T72-23 T72-23 T72-23 T72-23 PLATE-OPEN
FV -FLOW CONTROL VALVE
FCV -FLOW CONTROL VALVE
HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS (SELF-ACTUATED)
BOARD MOUNTED
INSTRUMENT
SPECTACLE
0002 0002 C 0002 A 0002 B 1002 1002 C 1002 A 1002 B 2002 2002 C 2002 A 2002 B 3002 3002 C 3002 A 3002 B 1002 1002 C 1002 A 1002 B 2002 2002 C 2002 A 2002 B 3002 3002 C 3002 A 3002 B FE -FLOW ELEMENT
PLATE-CLOSED FG -FLOW SIGHT GLASS
R/G
STATUS LIGHTS
RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)

CHECK VALVE FM -FLOW METER


FO -RESTRICTION ORIFICE MOTOR STATUS
PILOT LIGHT
PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
T71- GAS PROCESSING T72- NGL RECOVERY FR -FLOW RECORDER
BALL VALVE LOCAL MOUNTED
LEVEL 2 AREA SHUTDOWN LEVEL 2 AREA SHUTDOWN FT -FLOW TRANSMITTER
ML
INSTRUMENT
DOUBLE DISC
AND DEPRESSURIZATION SWITCHES AND DEPRESSURIZATION SWITCHES FY -FLOW RELAY
GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
LA -LEVEL ALARM
LV -LEVEL CONTROL VALVE RACK MOUNTED
PRESS.RELIEF VALVE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
(SELF-ACTUATED)
LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
VACUUM RELIEF VALVE LI -LEVEL INDICATOR
LR -LEVEL RECORDER INSTRUMENT
LS -LEVEL SWITCH AIR SUPPLY REQUIRED
T73-32 T73-33 T74-40 T74-41 T74-42 T74-43 T74-44 T74-45 T74-46 M MOTOR OPERATED
HZA HZA HZA HZA HZA HZA HZA HZA HZA VALVE LT -LEVEL TRANSMITTER
H
LTD -LEVEL TRANSDUCER
0002 0002 0002 0002 0002 0002 0002 0002 0002 ML -MOTOR STATUS LIGHT
HIGH
L
LOW

P MOV -MOTOR OPERATED VALVE


PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
PC -PRESSURE CONTROLLER FF
T73-32 T73-33 T74-40 T74-41 T74-42 T74-43 T74-44 T74-45 T74-46 CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
ZC ZC ZC ZC ZC ZC ZC ZC ZC FIELDBUS INSTRUMENT
PCV -PRESS. CONTROL VALVE
002 002 002 002 002 002 002 002 002 (SELF ACTUATED)
P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
T73-32 T73-32 T73-32 T73-32 T73-33 T73-33 T73-33 T73-33 T74-40 T74-40 T74-40 T74-40 T74-41 T74-41 T74-41 T74-41 T74-42 T74-42 T74-42 T74-42 T74-43 T74-43 T74-43 T74-43 T74-44 T74-44 T74-44 T74-45 T74-45 T74-45 T74-46 T74-46 T74-46 S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HS HZS HZS HS HZS HZS
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
0002 0002 C 0002 A 0002 B 0002 0002 C 0002 A 0002 B 0002 0002 C 0002 A 0002 B 0002 0002 C 0002 A 0002 B 0002 0002 C 0002 A 0002 B 0002 0002 C 0002 A 0002 B 0002 0002 A 0002 B 0002 0002 A 0002 B 0002 0002 A 0002 B VALVE NORMALLY
PDT -PRESS. DIFF. TRANSMITTER
SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
IN FIELD
PR -PRESSURE RECORDER
PS -PRESSURE SWITCH
T73- SALES GAS AND INJECTION GAS COMPRESSION PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
LEVEL 2 AREA SHUTDOWN T74- PRODUCT STORAGE PX -PRESSURE POINT INTERCONNECTING LOGIC
AND DEPRESSURIZATION SWITCHES LEVEL 2 AREA SHUTDOWN PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
AND DEPRESSURIZATION SWITCHES PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
SI -SPEED INDICATOR CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY
STEAM TRAP DISPLAYED ON CRT
TE -TEMP. ELEMENT
TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
T75-50 T75-51 T75-52 T75-53 T78-55 T83-81 T83-82 S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH
HZA HZA HZA HZA HZA HZA HZA DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
0002 1002 2002 3002 0002 0002 0002 PRESSURE SEWER TR -TEMP. RECORDER
(PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL
T75-50 T75-51 T75-52 T75-53 T78-55 T83-81 T83-82
ZC ZC ZC ZC ZC ZC ZC
002 002 002 002 002 002 002 REFERENCE DRAWINGS
LETTER IDENTIFICATION OF LINES AD-036204
PIPING SYMBOLS AB-036227
T75-50 T75-50 T75-50 T75-51 T75-51 T75-51 T75-51 T75-52 T75-52 T75-52 T75-52 T75-53 T75-53 T75-53 T75-53 T78-55 T78-55 T78-55 T83-81 T83-81 T83-81 T83-81 T83-82 T83-82 T83-82 T83-82 EQUIPMENT SYMBOLS AB-036305
HS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HZS HS HZS HZS HS HZS HZS HZS HS HZS HZS HZS
INSTRUMENT SYMBOLS AC-036950
0002 0002 A 0002 B 1002 1002 C 1002 A 1002 B 2002 2002 C 2002 A 2002 B 3002 3002 C 3002 A 3002 B 0002 0002 A 0002 B 0002 0002 C 0002 A 0002 B 0002 0002 C 0002 A 0002 B PIPING LAYOUT INDEX
RESET SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN RESET DEPRESSURIZE SHUTDOWN SHUTDOWN PLOT PLAN
PROCESS FLOW DIAGRAM
HYDROSTATIC TEST DIAGRAM
DRAWING CONTROL FOR J.O.

T75- SULFUR RECOVERY T78- SULFUR LOADING AND HANDLING T83- NGL FRACTIONATION LEVEL 2/ INSTRUMENT INSTALLATION SCHEDULES
LEVEL 2 AREA SHUTDOWN LEVEL 2 AREA SHUTDOWN AREA SHUTDOWN
AND DEPRESSURIZATION SWITCHES AND DEPRESSURIZATION SWITCHES AND DEPRESSURIZATION SWITCHES

C 05 29 20

B 02 14 20

LEVEL 2 EMERGENCY DEPRESSURIZATION EXECUTION STATUS LAMPS A 09 24 19

T70-01 T70-02 T70-03 T70-04 T70-06 T70-06 T70-06 T70-07 T71-10 T71-11 T71-12 T71-13 T72-21 T72-22 T72-23 T73-32 T73-33 T74-40 T74-41 T74-42 T74-43 T75-51 T75-52 T75-53 T78-55 T83-81 T83-82 REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY

HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL HZL REVISION VALIDATION
0002 0002 0002 0002 1002 2002 3002 0002 0002 1002 2002 3002 1002 2002 3002 1002 2002 0002 0002 0002 0002 1002 2002 3002 0002 1002 2002 THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

NOTE 5
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
T80-00 ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
ZC MASTER BLOWDOWN CONTROLLER 05/29/20 05/29/20

001 REV.NO. DATE REVISION DESCRIPTION DSN


NOTE 3, 4 C 05/29/20 ISSUED FOR REVIEW 23547
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

T70-01 T70-02 T70-03 T70-04 T70-06 T70-07 T71-10 T71-11 T71-12 T71-13 T72-21 T72-22 T72-23 T73-32 T73-33 T74-40 T74-41 T74-42 T74-43 T75-51 T75-52 T75-53 T78-55 T83-81 T83-82 SAUDI ARABIAN OIL COMPANY
DRAWING TYPE
ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC
PIPING & INSTRUMENTATION DIAGRAM PID
002 002 002 002 002 002 002 002 002 002 002 002 002 002 002 002 002 002 002 002 002 002 002 002 002
LEVEL 2 EMERGENCY SHUTDOWN SWITCHES
LEVEL 2 EMERGENCY DEPRESSURIZATION SIGNALS
COMMON AREA
TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 010 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
1. EPC CONTRACTOR SHALL EXPAND THE LEGEND SHEET AS
REQUIRED TO IMPLEMENT THE TAGGING OF ALL INSTRUMENT
ITEMS SHOWN ON THE LEGEND SHEET SPECIFIC DETAILS
INCLUDING THE LOCAL ELECTRICAL SWITCHES AND LAMPS.
2. LOOP TAG NUMBERS AS IDENTIFIED ON P&ID'S SHALL APPLY TO
ALL OTHER INSTRUMENT ITEMS SHOWN ON THE LEGEND SHEET
SPECIFIC DETAIL.
3. LOCAL MCS SIGNALS NOT TAGGED.
4. STOP SIGNAL OF VIBRATION INDICATION COULD BE VSH OR
VSHH IN DEPENDENT OF EACH RELEVANT P&ID.

LOCAL ELECTRICAL MOTOR CONTROL STATION LOCAL ELECTRICAL MOTOR CONTROL STATION LOCAL ELECTRICAL MOTOR CONTROL STATION

NOTE 3 NOTE 3 LOCAL/OFF


NOTE 3, 4
LOCAL/OFF LOCAL/OFF
/REMOTE /REMOTE /REMOTE
HOA START STOP RUNNING STOPPED HOA START STOP RUNNING STOPPED HOA START STOP RUNNING STOPPED

LOCAL/REMOTE LOCAL/REMOTE RUNNING/STOPPED


STATUS STATUS
ML
MXL MXL

LOCAL/REMOTE
RUNNING/STOPPED RUNNING/STOPPED STATUS
LEGEND
ML ML MXL PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS -VIBRATION SWITCH
MCC MCC MCC PROCESS LINE AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
STOP STOP STOP FAILURE STEADY XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
MHS MHS MHS AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
(*) (*)
B B B INSTRUMENT
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
FAILURE STEADY
ZC TRIP ZC TRIP ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
F-FLOW P-PRESS.
START

INPUTS
AT -ANALYZER TRANSMITTER
COMMON FAULT COMMON FAULT DT
L-LEVEL T-TEMP.
-DENSITY TRANSMITTER
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
MA MA MHS REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
A SPECTACLE MOUNTED INSTR.
FV -FLOW CONTROL VALVE
PLATE-OPEN
(V) FCV -FLOW CONTROL VALVE
BOARD MOUNTED
VSH COMMON FAULT (SELF-ACTUATED)
START SPECTACLE INSTRUMENT

M M M MA PLATE-CLOSED
FE
FG
-FLOW ELEMENT
-FLOW SIGHT GLASS
R/G
MHS STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
A FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
(*) GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
FM -FLOW METER
DETAIL 7A MHS DETAIL 7B MHS VAH STOP DETAIL 8A MHS CHECK VALVE
FO -RESTRICTION ORIFICE MOTOR STATUS

P&ID SYMBOL P&ID SYMBOL A P&ID SYMBOL PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
PILOT LIGHT

FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
DOUBLE DISC FY -FLOW RELAY
GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
DETAIL 7A DETAIL 7B DETAIL 8A DETAIL 8A
DETAIL 7A DETAIL 7B LA -LEVEL ALARM

LV PUMP MOTOR WITH DCS CONTROL / WITH ESD TRIP LV PUMP MOTOR WITH DCS CONTROL / WITH ESD TRIP / DCS START FAN MOTOR WITH DCS CONTROL / STOP VIB PRESS.RELIEF VALVE
LV -LEVEL CONTROL VALVE RACK MOUNTED
LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
(SELF-ACTUATED)
(*) IF SPECIFIED ON P&ID (*) IF SPECIFIED ON P&ID (*) IF SPECIFIED ON P&ID LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
VACUUM RELIEF VALVE LI -LEVEL INDICATOR

M M M LR
LS
-LEVEL RECORDER
-LEVEL SWITCH
INSTRUMENT
AIR SUPPLY REQUIRED
M MOTOR OPERATED
LT -LEVEL TRANSMITTER
VALVE H
LTD -LEVEL TRANSDUCER HIGH LOW
ML -MOTOR STATUS LIGHT L
P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
PC -PRESSURE CONTROLLER FF
CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT

(SELF ACTUATED)
P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
IN FIELD
PR -PRESSURE RECORDER
PS -PRESSURE SWITCH
PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
PX -PRESSURE POINT INTERCONNECTING LOGIC
PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
SI -SPEED INDICATOR CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
LOCAL ELECTRICAL MOTOR CONTROL STATION LOCAL ELECTRICAL MOTOR CONTROL STATION LOCAL ELECTRICAL MOTOR CONTROL STATION TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
IBT -INVERTED BUCKET
LOCAL/OFF
NOTE 3, 4 NOTE 3 NOTE 3 (SELF-ACTUATED) CAN BE NORMALLY
LOCAL/OFF LOCAL/OFF STEAM TRAP
TE -TEMP. ELEMENT DISPLAYED ON CRT
/REMOTE /REMOTE /REMOTE TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
HOA START STOP RUNNING STOPPED HOA START STOP RUNNING STOPPED HOA START STOP RUNNING STOPPED S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER (PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL

REFERENCE DRAWINGS
LETTER IDENTIFICATION OF LINES AD-036204
PIPING SYMBOLS AB-036227
LOCAL/REMOTE LOCAL/REMOTE LOCAL/REMOTE
STATUS STATUS STATUS
EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950
MXL MXL MXL
PIPING LAYOUT INDEX
PLOT PLAN
PROCESS FLOW DIAGRAM
RUNNING/STOPPED HYDROSTATIC TEST DIAGRAM
ML SPEED SETPOINT SPEED SETPOINT DRAWING CONTROL FOR J.O.
INSTRUMENT INSTALLATION SCHEDULES

RUNNING/STOPPED RUNNING/STOPPED
MCC VFD MCC VFD
ML ML
SPEED SETPOINT
(*) (*)
MCC VFD ZC TRIP ZC TRIP
STOP STOP STOP
A 05 29 20
MHS MHS MHS
(*) B
REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
B B
VAH STOP REVISION VALIDATION
A START COMMON FAULT COMMON FAULT THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
MHS REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
M M MA
M MA
(V) A
VSH
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
COMMON FAULT START (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
DETAIL 15A MHS MHS MHS
MA DETAIL 16A DETAIL 16B ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
P&ID SYMBOL MHS UCH HJL
P&ID SYMBOL P&ID SYMBOL 05/29/20 05/29/20
A
REV.NO. DATE REVISION DESCRIPTION DSN
A 05/29/20 ISSUED FOR REVIEW

DETAIL 15A DETAIL 15A DETAIL 16A DETAIL 16B JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
DETAIL 16A DETAIL 16B
FAN MOTOR WITH VARIABLE SPEED, DCS CONTROL / STOP VIB LV PUMP OR COMPRESSOR MOTOR WITH SPEED AT AND DCS CONTROL / WITH ESD TRIP LV PUMP MOTOR WITH DCS CONTROL / WITH ESD TRIP / DCS START 10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

(*) IF SPECIFIED ON P&ID (*) IF SPECIFIED ON P&ID (*) IF SPECIFIED ON P&ID SAUDI ARABIAN OIL COMPANY
DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
M M M INSTRUMENT SYMBOLS AND LEGEND
COMMON AREA
TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

A T80 A CA-033800 011 A


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
21.1- NITROGEN 21.2- OXYGEN NOTES: C
A. FOR STANDARD SYMBOLS / LEGENDS / TYPICAL DETAILS AND
GENERAL NOTES SEE DRAWINGS T80-A-CA-033800-001 TO 010.
B. P&ID IS GENERIC FOR ALL UTILITY BATTERY LIMITS ON THE TGP
FI FI
FOR DETAILS OF SPECIFIC BATTERY LIMITS ISOLATION AND
INSTRUMENTATION.
B C B C
C
1. CONNECTIONS TO FLARE SUB-HEADER SHALL ENTER THE TOP
OF THE MAIN HEADER, WITH THE CONNECTION AT A 45 DEGREE
P&T COMP
P&T COMP ANGLE TO THE HORIZONTAL IN THE FLOW DIRECTION OF THE
FY TI FY TI HEADER.
2. SPACER & SPADE USED FOR LINE SIZES 12" AND ABOVE,
SPECTACLE BLIND USED FOR LINE SIZES BELOW 12".
3. NOT APPLICABLE FOR ALL UNITS.
FF FF
PI FI TT PI FI TT C
A A

FF FF FF FF
B.L PI PT FT TE B.L PI PT FT TE
T79 TX T79 TX

[T79 LINE NUMBER] [TX LINE NUMBER] [T79 LINE NUMBER] [TX LINE NUMBER]

1" D 1" D 1" D 1" D

FE FE
+ +

LEGEND
21.3- LP/LT FLARE GAS 21.4- HP FLARE GAS PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS -VIBRATION SWITCH
AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
PROCESS LINE
FAILURE STEADY XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
INSTRUMENT
FAILURE STEADY
ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
DT -DENSITY TRANSMITTER
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
PI PI SPECTACLE FV -FLOW CONTROL VALVE
MOUNTED INSTR.
B.L B.L PLATE-OPEN FCV -FLOW CONTROL VALVE
TX T79 TX T79 (SELF-ACTUATED)
BOARD MOUNTED
INSTRUMENT
SPECTACLE FE -FLOW ELEMENT
2" V 2" V PLATE-CLOSED FG -FLOW SIGHT GLASS
R/G
SLOP SLOP
STATUS LIGHTS
E E GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
CSO CSO CSO CSO GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)

CHECK VALVE FM -FLOW METER


1" D 1" D 1" D 1" D FO -RESTRICTION ORIFICE MOTOR STATUS
PILOT LIGHT
PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
DOUBLE DISC FY -FLOW RELAY
GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
LA -LEVEL ALARM
LV -LEVEL CONTROL VALVE RACK MOUNTED
PRESS.RELIEF VALVE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
(SELF-ACTUATED)
LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
VACUUM RELIEF VALVE LI -LEVEL INDICATOR
LR -LEVEL RECORDER INSTRUMENT
LS -LEVEL SWITCH AIR SUPPLY REQUIRED
M MOTOR OPERATED
LT -LEVEL TRANSMITTER
VALVE H
LTD -LEVEL TRANSDUCER HIGH LOW
ML -MOTOR STATUS LIGHT L
P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR
21.5- LP FUEL GAS 21.6- HP FUEL GAS VALVE PB -PUSHBUTTON
TWO PEN RECORDER

PC -PRESSURE CONTROLLER FF
FI FI CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION

B C B C PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT

(SELF ACTUATED)
P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
P&T COMP P&T COMP WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
FY TI FY TI S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
FF FF PI -PRESSURE INDICATOR (DCS) DISTRIBUTED CONTROL
PI FI TT PI FI TT PIC -PRESS. INDICATOR CONTROLLER
SYSTEM, OPERATOR INACCESSIBLE
IN FIELD
A A PR -PRESSURE RECORDER
PS -PRESSURE SWITCH
PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
PX -PRESSURE POINT INTERCONNECTING LOGIC
FF FF FF FF PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
B.L PI PT FT TE B.L PI PT FT TE PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
T79 TX T79 TX SI -SPEED INDICATOR
(PLC) PROGRAMMABLE LOGIC
CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY
STEAM TRAP DISPLAYED ON CRT
TE -TEMP. ELEMENT
1" D 1" D 1" D 1" D 1" D 1" D TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH
FE FE DCS LOCATION NORMALLY
ACCESSIBLE TO OPERATOR
+ + TI -TEMP. INDICATOR
S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER (PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL

REFERENCE DRAWINGS
LETTER IDENTIFICATION OF LINES AD-036204
21.7- INSTRUMENT AIR 21.8- UTILITY AIR PIPING SYMBOLS AB-036227
EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950
PIPING LAYOUT INDEX
FI C PLOT PLAN
B C PROCESS FLOW DIAGRAM
DEV
PAD HYDROSTATIC TEST DIAGRAM
DRAWING CONTROL FOR J.O.
P&T COMP
MED INSTRUMENT INSTALLATION SCHEDULES
FY TI PZI PZALL PZI
NOTE 3
M

C 05 29 20
FF 2oo3
PI FI TT ZC PI FI B 02 14 20
A
A 09 24 19
C C C
REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
FF FF FF FF REVISION VALIDATION
B.L PI PT FT TE PZT PZT PZT B.L PI PT FT
T79 TX T79 TX THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
A B C
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

[T79 LINE NUMBER 1] [TX LINE NUMBER 1] [T79 LINE NUMBER] [TX LINE NUMBER]
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
1" D 1" D 1" D 1" D ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
FE FE 05/29/20 05/29/20
+ +

REV.NO. DATE REVISION DESCRIPTION DSN


C 05/29/20 ISSUED FOR REVIEW 25266
B.L
JOB ORDER/EWO NO.
T79 TX THIS REVISION IS NOT TO BE USED FOR
10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

[T79 LINE NUMBER 2] [TX LINE NUMBER 2]


SAUDI ARABIAN OIL COMPANY
DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
1" D 1" D
STANDARD INTERFACE I
COMMON AREA
TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 021 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
22.1- UTILITY WATER 22.2- SEWAGE NOTES: C
A. FOR STANDARD SYMBOLS / LEGENDS / TYPICAL DETAILS AND
GENERAL NOTES SEE DRAWINGS T80-A-CA-033800-001 TO 010.
B. P&ID IS GENERIC FOR ALL UTILITY BATTERY LIMITS ON THE TGP.
FOR DETAILS OF SPECIFIC BATTERY LIMITS ISOLATION AND
INSTRUMENTATION.
C
1. SPACER & SPADE USED FOR LINE SIZES 12" AND ABOVE,
FF SPECTACLE BLIND USED FOR LINE SIZES BELOW 12".
PI FI TT TI 2. VALVE TYPE AS PER PIPE SPECIFICATION TO BE SELECTED
LATER.

FF FF
PI PT FT TE
B.L B.L B.L
T79 TX AG UG TX T79

[T79 LINE NUMBER] [TX LINE NUMBER] [TX LINE NUMBER] [T79 LINE NUMBER]

NOTE 2 NOTE 2
1" D 1" D 1" D 1" D

FE
+

22.3- STEAM CONDENSATE 22.4- COOLED CONDENSATE


FI
C
LEGEND
B
PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS -VIBRATION SWITCH
P&T COMP FF PROCESS LINE AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
FAILURE STEADY XL -PILOT LIGHT
PI FY TI TT INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
INSTRUMENT
FAILURE STEADY
ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
FF FF DT -DENSITY TRANSMITTER
L-LEVEL T-TEMP.
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
PT FT FI TE TI PI REDUCER ESD -EMER. SHUTDOWN SYSTEM
C FF LOCAL PANEL
FC - FLOW CONTROLLER
A B.L PI FI TT TI SPECTACLE FV -FLOW CONTROL VALVE
MOUNTED INSTR.

TX T79 PLATE-OPEN FCV -FLOW CONTROL VALVE


BOARD MOUNTED
(SELF-ACTUATED) INSTRUMENT
[TX LINE NUMBER] [T79 LINE NUMBER 1] SPECTACLE FE -FLOW ELEMENT
PLATE-CLOSED R/G
HC FG -FLOW SIGHT GLASS
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
C FF FF FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
1" D 1" D 1" D 1" D 2" D PI TI PT FT TE GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
B.L FM -FLOW METER
CHECK VALVE
FE T79 TX SC-4 FO -RESTRICTION ORIFICE MOTOR STATUS
+
PILOT LIGHT
PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
MIN. 1" V 1" V
FR -FLOW RECORDER
BALL VALVE LOCAL MOUNTED
[T79 LINE NUMBER] [TX LINE NUMBER] FT -FLOW TRANSMITTER
ML
INSTRUMENT
DOUBLE DISC FY -FLOW RELAY
GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
2" D 1" D 2" D 1" D LA -LEVEL ALARM
LV -LEVEL CONTROL VALVE RACK MOUNTED
FE PRESS.RELIEF VALVE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
+
(SELF-ACTUATED)
MIN. LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
TI PI
VACUUM RELIEF VALVE LI -LEVEL INDICATOR
B.L -LEVEL RECORDER INSTRUMENT
LR
TX T79 M MOTOR OPERATED LS -LEVEL SWITCH AIR SUPPLY REQUIRED

LT -LEVEL TRANSMITTER
VALVE H
LTD -LEVEL TRANSDUCER
[T79 LINE NUMBER 2] HIGH LOW
ML -MOTOR STATUS LIGHT L
P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
1" D 1" D 1" D 2" D
PC -PRESSURE CONTROLLER FF
CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT

MIN. (SELF ACTUATED)


P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
INDICATOR CONTROLLER
22.5- DEMINERALIZED WATER 22.6- COOLING WATER SUPPLY S
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL
SYSTEM, OPERATOR ACCESSIBLE
IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
IN FIELD
PR -PRESSURE RECORDER
PS -PRESSURE SWITCH
PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
PX -PRESSURE POINT INTERCONNECTING LOGIC
FF FF
PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
PI FI TT TI PI FI TT TI PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
SI -SPEED INDICATOR CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
FF FF FF FF TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
PI PT FT TE PI PT FT TE IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY
B.L B.L STEAM TRAP
TE -TEMP. ELEMENT DISPLAYED ON CRT
T79 TX T79 TX TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
[T79 LINE NUMBER] [TX LINE NUMBER] [T79 LINE NUMBER] [TX LINE NUMBER] S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER (PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
NOTE 2 NOTE 2 D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
1" D 1" D 1" D 1" D V -VENT TW -THERMOWELL

FE FE
+ +

REFERENCE DRAWINGS
LETTER IDENTIFICATION OF LINES AD-036204
PIPING SYMBOLS AB-036227
EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950
PIPING LAYOUT INDEX
PLOT PLAN
PROCESS FLOW DIAGRAM
HYDROSTATIC TEST DIAGRAM
DRAWING CONTROL FOR J.O.
INSTRUMENT INSTALLATION SCHEDULES

22.7- CHILLED WATER SUPPLY 22.8- COOLING/CHILLED WATER RETURN

C 05 29 20

B 02 14 20
FF H FF
PI FI TT TI PI FI TT TI A 09 24 19

REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY

REVISION VALIDATION
THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
FF FF FF FF REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
PI PT FT TE PI PT FT TE
B.L B.L
T79 TX TX T79
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
[T79 LINE NUMBER] [TX LINE NUMBER] [TX LINE NUMBER] [T79 LINE NUMBER] ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
CC UCH HJL
05/29/20 05/29/20
NOTE 2 NOTE 2
1" D 1" D 1" D 1" D REV.NO. DATE REVISION DESCRIPTION DSN
C 05/29/20 ISSUED FOR REVIEW 25267
FE FE
+ +

JOB ORDER/EWO NO.


THIS REVISION IS NOT TO BE USED FOR
10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY


DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
STANDARD INTERFACE II
COMMON AREA
TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 022 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTE CONT'D.: NOTES:
23.1 - HP STEAM C

FI 12. NUMBER AND LOCATION OF STEAM UTILITY STATIONS TO BE A. FOR STANDARD SYMBOLS/LEGENDS/TYPICAL DETAILS AND
DETERMINED LATER. GENERAL NOTES SEE DRAWINGS T80-A-CA-033800-001 TO 010.
B C B. P&ID IS GENERIC FOR ALL UTILITY BATTERY LIMITS ON THE TGP.
FOR DETAILS OF SPECIFIC BATTERY LIMITS ISOLATION AND C
INSTRUMENTATION.
P&T
FY COMP TI H 1. STEAM TRAPS TO BE INSTALLED AT LOW POINTS AND REGULAR
INTERVALS ALONG PIPE RACK. TO BE CONFIRMED LATER
L
IN ACCORDANCE WITH SAUDI ARAMCO STANDARDS.
STEAM TRAPS ROUTED TO SRU TRAINS VIA HP/LP STEAM TRAP
COLLECTION SYSTEM.
H FF 2. FINAL NUMBER, SIZE AND LOCATION OF VENTS AND DRAINS
PI FI TT TO BE CONFIRMED LATER TO BE PROVIDED IN
A ACCORDANCE WITH SAES-A-400 AND SAES-A-401, AND
L TO REFLECT PIPING LAYOUT REQUIREMENT.
V 3. LINE SIZES TO BE CONFIRMED LATER.
4. WARMUP BYPASS FOR LINES: 4" AND ABOVE FOR HP STEAM,
3" 3" PI TI FF FF
NOTE 3, 4 NOTE 9 12" AND ABOVE FOR LP STEAM.
B.L PT FT
PI TE TI 5. ISOLATION VALVES AND RING SPACERS PROVIDED TO ALLOW
T79 TX POSITIVE MAINTENANCE ISOLATION, ALLOWING FOR SOURCE OF
1" D
PRESSURIZATION ORIGINIATING FROM EITHER UPSTREAM OR
V V DBB NOTE 5, 8 1" D V DBB DOWNSTREAM OF THE SPACER POSITIONS.
DBB
(TX LINE NO. 1) 6. STEAM TRAP PROVIDED AHEAD OF FLOWMETER.
(T79 LINE NO. 1)
HC 7. STRAIGHT PIPE LENGTH UPSTREAM AND DOWNSTREAM OF
NOTE 2 FLOWMETER TO COMPLY WITH SUPPLIER RECOMMENDATIONS.
ST 2" D 1" D 1" D 1" D D ST NOTE 1, 6 ST
8. SPACER & SPADE USED FOR LINE SIZES 12" AND ABOVE,
MIN. SPECTACLE BLIND USED FOR LINE SIZES BELOW 12".
NOTE 1 NOTE 1 9. SECOND SET OF WARMUP LINES USED FOR CASE OF SRU,
NOTE 7 WHERE STEAM FLOW IS FROM THE UNIT.
MIN. MIN. FE
+
10. FOR FLOW LINES RUNNING FROM THE SRU, PRESSURE AND
TEMPERATURE TRANSMITTERS SHOULD BE LOCATED AFTER
THE FLOW TRANSMITTER.

HC
11. DELETED.
V
NOTE 3, 4 3" 3" PI TI
B.L NOTE 9 LEGEND
T79 TX PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
1" D SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT

V V DBB NOTE 5, 8 1" D AIR FAILURE OPEN VS -VIBRATION SWITCH


AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
PROCESS LINE
FAILURE STEADY
(T79 LINE NO. 2) (TX LINE NO. 2) XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR LINE AIR FAILURE CLOSE XS
NOTE 2 AO/AFS -AIR TO OPEN/AIR ZV
-LIMIT SWITCH
INSTRUMENT -SAFETY SHUTDOWN VALVE
ST 2" D 1" D 1" D 1" D ELECTRICAL LINE
FAILURE STEADY
AOV -AIR OPERATED VALVE DATA LOGGER POINT
F-FLOW P-PRESS.
NOTE 1

INPUTS
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
DT -DENSITY TRANSMITTER
MIN. MIN. X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
SPECTACLE MOUNTED INSTR.
FV -FLOW CONTROL VALVE
PLATE-OPEN FCV -FLOW CONTROL VALVE
BOARD MOUNTED
(SELF-ACTUATED) INSTRUMENT
SPECTACLE FE -FLOW ELEMENT
PLATE-CLOSED FG -FLOW SIGHT GLASS
R/G
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
23.2 - LP STEAM FI CHECK VALVE FM -FLOW METER
MOTOR STATUS
FO -RESTRICTION ORIFICE
PILOT LIGHT
B C PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
DOUBLE DISC FY -FLOW RELAY
P&T GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
COMP H ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
FY TI LA -LEVEL ALARM
LV -LEVEL CONTROL VALVE
L PRESS.RELIEF VALVE
RACK MOUNTED
LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
(SELF-ACTUATED)
LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
H FF VACUUM RELIEF VALVE LI -LEVEL INDICATOR
PI FI TT LR -LEVEL RECORDER INSTRUMENT
LS -LEVEL SWITCH AIR SUPPLY REQUIRED
A M MOTOR OPERATED
1" V L VALVE LT -LEVEL TRANSMITTER
H
-LEVEL TRANSDUCER
NOTE 3, 4 2"- 4" 2" - 4" LTD HIGH LOW
ML -MOTOR STATUS LIGHT L
B.L -MOTOR OPERATED VALVE
PI TI FF FF P
PISTON OPERATED
MOV
NA -ANNUNCIATOR
T79 TX PI PT FT TE TI VALVE
TWO PEN RECORDER
PB -PUSHBUTTON
1" D
PC -PRESSURE CONTROLLER FF
1" V 2" V NOTE 5, 8 2" V CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
FIELDBUS INSTRUMENT
PCV -PRESS. CONTROL VALVE
(T79 LINE NO. 1) (TX LINE NO. 1) (SELF ACTUATED)
HC P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
NOTE 2 CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
ST 2" D 2" D 2" D 2" D ST NOTE 1, 6 ST INDICATOR CONTROLLER
(DCS) DISTRIBUTED CONTROL
S SYSTEM, OPERATOR ACCESSIBLE
MIN. SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
NOTE 1 NOTE 1 INDICATOR SWITCH
NOTE 7 (DCS) DISTRIBUTED CONTROL
MIN. MIN. FE VALVE NORMALLY
PDT -PRESS. DIFF. TRANSMITTER
SYSTEM, OPERATOR INACCESSIBLE
+ PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
IN FIELD

HC
PR -PRESSURE RECORDER
1" V PS -PRESSURE SWITCH
DISTRIBUTED CONTROL
NOTE 3, 4 2" - 4" 2" - 4" PT -PRESSURE TRANSMITTER
PX -PRESSURE POINT INTERCONNECTING LOGIC
B.L PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
PI TI
T79 TX PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
1" D RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
SI -SPEED INDICATOR CONTROLLER, NORMALLY
1" V 2" V NOTE 5, 8 2" V SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
(T79 LINE NO. 2) (TX LINE NO. 2) TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
NOTE 2 ST IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY
STEAM TRAP DISPLAYED ON CRT
TE -TEMP. ELEMENT
ST 2" D 2" D 2" D TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
NOTE 1 TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
NOTE 12 S -DRAIN TO
MIN. MIN. PRESSURE SEWER TR -TEMP. RECORDER
(PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL

REFERENCE DRAWINGS
LETTER IDENTIFICATION OF LINES AD-036204
23.3 - BOILER FEED WATER PIPING SYMBOLS AB-036227
EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950
TI PIPING LAYOUT INDEX
PLOT PLAN
PROCESS FLOW DIAGRAM
HYDROSTATIC TEST DIAGRAM

FF DRAWING CONTROL FOR J.O.


H
PI FI TT INSTRUMENT INSTALLATION SCHEDULES

C 05 29 20
FF FF
PI PI PT FT TE TI B 02 14 20
B.L
TI A 09 24 19
T79 TX
REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
NOTE 5, 8 SC-5
1" V DBB DBB DBB REVISION VALIDATION
(T79 LINE NO. 1) (TX LINE NO. 1) 2" 2" THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
HC
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

2" D 1" D 1" D 2" D 1" D 1" D 2" D


DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
NOTE 2 FE (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
+

ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE


UCH HJL
05/29/20 05/29/20

REV.NO. DATE REVISION DESCRIPTION DSN


C 05/29/20 ISSUED FOR REVIEW 25268

JOB ORDER/EWO NO.


PI THIS REVISION IS NOT TO BE USED FOR
B.L 10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED
TI
T79 TX
SAUDI ARABIAN OIL COMPANY
NOTE 5, 8 1" V DBB DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
(T79 LINE NO. 2) (TX LINE NO. 2) 2" 2"
HC
STANDARD INTERFACE III
2" D 1" D 1" D 2" D 1" D 1" D COMMON AREA
NOTE 2 TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 023 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
1. FINAL NUMBER AND LOCATION OF VENTS AND DRAINS TO BE
CONFIRMED LATER AND TO BE PROVIDED IN
ACCORDANCE WITH SAES-A-400 AND SAES-A-401 AND TO
HP STEAM HEADER (600#) HP STEAM HEADER (600#) LP STEAM HEADER (150#) REFLECT PIPING LAYOUT REQUIREMENTS.
2. LOCATED AT BOOT.
3. TO BE ACCESSIBLE AT GRADE.
NOTE 6 NOTE 6 NOTE 6 4. LOCATED AT HEADER.
5. "X" TO BE REPLACED BY APPROPRIATE TYPE OF STEAM TRAP
SELECTED FROM LEGEND. REFER TO SABP-A-007, STEAM TRAP
STMS STMS STMS MANAGEMENT FOR ENERGY EFFICIENCY, (BEST PRACTICE),
AAH AAH AAH FOR GUIDANCE ON MOST APPROPRIATE TYPE OF TRAP.
XXXX XXXX XXXX 6. FOR GUIDANCE ON SIZE OF STEAM HEADER BOOT, REFER TO
NOTE 2 NOTE 2 NOTE 2
THE TABLE BELOW.
NOTE 7 NOTE 7 NOTE 7
7. AUTOMATIC WIRELESS STEAM TRAP MONITORING SYSTEM.
8. STEAM TRAPS IN REMOTE AREAS (WHERE THE CONDENSATE
NOTE 3 RECOVERY SYSTEM DOES NOT EXTEND TO), SHALL DISCHARGE
WASTE CONDENSATE ONTO PURPOSE MADE CONCRETE SLABS,
NOTE 3 NOTE 3 C NOTE 3 THUS PROTECTING GROUND SURFACE BENEATH.
NOTE 3 NOTE 3 9. INTEGRAL TYPE WITH STRAINER.
C NOTE 4 STEAM PIPE CLASS C C NOTE 4 STEAM PIPE CLASS
AT AT AT
NOTE 3 CONDENSATE PIPE CLASS NOTE 3 NOTE 3 CONDENSATE
SP XXXX SP XXXX SP XXXX
PIPE CLASS
0001 C 0001 C 0002 C
NOTE 3 C C C
ST CONDENSATE NOTE 3 ST ST CONDENSATE
NOTE 8
NOTE 3 NOTE 3 HEADER NOTE 3 NOTE 3 NOTE 3 HEADER
NOTE 9 NOTE 9 NOTE 9

DISCHARGING TO A CLOSED SYSTEM DISCHARGING TO AN OPEN SYSTEM DISCHARGING TO A CLOSED SYSTEM


VERTICAL INSTALLATION VERTICAL INSTALLATION VERTICAL INSTALLATION

ASSEMBLY DETAIL ST1-X NOTE 5 ASSEMBLY DETAIL ST2-X NOTE 5 ASSEMBLY DETAIL ST3-X NOTE 5 LEGEND
PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS -VIBRATION SWITCH
AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
PROCESS LINE
FAILURE STEADY XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
INSTRUMENT
FAILURE STEADY
ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
DT -DENSITY TRANSMITTER
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
SPECTACLE MOUNTED INSTR.
FV -FLOW CONTROL VALVE
PLATE-OPEN FCV -FLOW CONTROL VALVE
BOARD MOUNTED
(SELF-ACTUATED) INSTRUMENT
SPECTACLE FE -FLOW ELEMENT
PLATE-CLOSED FG -FLOW SIGHT GLASS
R/G
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)

CHECK VALVE FM -FLOW METER


FO -RESTRICTION ORIFICE MOTOR STATUS
LP STEAM HEADER (150#) HP STEAM HEADER (600#) HP STEAM HEADER (600#) PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
PILOT LIGHT

FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
NOTE 6 NOTE 6 NOTE 6 DOUBLE DISC FY -FLOW RELAY
GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
LA -LEVEL ALARM
STMS STMS STMS LV -LEVEL CONTROL VALVE
AAH AAH AAH PRESS.RELIEF VALVE
RACK MOUNTED
LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)

XXXX XXXX XXXX (SELF-ACTUATED)


NOTE 2 NOTE 2 NOTE 2 LG -LEVEL GAUGE GLASS ELECTRICAL

NOTE 7 NOTE 7 NOTE 7 LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED


VACUUM RELIEF VALVE LI -LEVEL INDICATOR
LR -LEVEL RECORDER INSTRUMENT

NOTE 3 NOTE 4 STEAM PIPE CLASS M MOTOR OPERATED LS -LEVEL SWITCH AIR SUPPLY REQUIRED

LT -LEVEL TRANSMITTER
VALVE H
CONDENSATE LTD -LEVEL TRANSDUCER HIGH LOW
ML -MOTOR STATUS LIGHT
C NOTE 3 NOTE 3 PIPE CLASS NOTE 3 L
P MOV -MOTOR OPERATED VALVE
C NOTE 3 C C PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
AT AT AT
NOTE 3 NOTE 3 NOTE 3 PC -PRESSURE CONTROLLER FF
SP XXXX SP XXXX SP XXXX CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
CONDENSATE PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT
0002 C 0001 C C
HEADER 0001 (SELF ACTUATED)
C NOTE 8 NOTE 3 C NOTE 3 C NOTE 3 P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
ST ST ST WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
NOTE 3 NOTE 3 NOTE 3 S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
NOTE 9 NOTE 9 NOTE 9 SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
NOTE 3 NOTE 3 NOTE 3
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
NOTE 8 CLOSED
PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
DISCHARGING TO AN OPEN SYSTEM DISCHARGING TO A CLOSED SYSTEM DISCHARGING TO A OPEN SYSTEM PIC -PRESS. INDICATOR CONTROLLER
SYSTEM, OPERATOR INACCESSIBLE
IN FIELD
PR -PRESSURE RECORDER
VERTICAL INSTALLATION HORIZONTAL INSTALLATION HORIZONTAL INSTALLATION PS -PRESSURE SWITCH
PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
ASSEMBLY DETAIL ST4-X NOTE 5 ASSEMBLY DETAIL ST5-X NOTE 5 ASSEMBLY DETAIL ST6-X NOTE 5 PX
PY
-PRESSURE POINT
-PRESS. COMPUTATION MOD.
INTERCONNECTING LOGIC
CONTROLLER WITH BINARY
PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
SI -SPEED INDICATOR CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY
STEAM TRAP DISPLAYED ON CRT
TE -TEMP. ELEMENT
TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER (PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL

STEAM HEADER BOOT GUIDE REFERENCE DRAWINGS


LETTER IDENTIFICATION OF LINES AD-036204
PIPING SYMBOLS AB-036227
LP STEAM HEADER (150#) LP STEAM HEADER (150#) EQUIPMENT SYMBOLS AB-036305

D INSTRUMENT SYMBOLS AC-036950


PIPING LAYOUT INDEX
NOTE 6 NOTE 6
PLOT PLAN
PROCESS FLOW DIAGRAM

STMS B A HYDROSTATIC TEST DIAGRAM


STMS AAH
AAH DRAWING CONTROL FOR J.O.
XXXX XXXX INSTRUMENT INSTALLATION SCHEDULES
NOTE 2 NOTE 2
NOTE 7 NOTE 7

NOTE 4 STEAM PIPE CLASS


C 05 29 20
CONDENSATE PIPE CLASS B 02 14 20
C NOTE 3 C NOTE 3 PIPE DIAMETER (D) BOOT DIAMETER (A) BOOT DEPTH (B)
C A 09 24 19
C
AT CONDENSATE AT A = ONE SIZE REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
NOTE 3 NOTE 3 10 INCH AND SMALLER B = 18 INCH - 24 INCH
SP XXXX HEADER SP XXXX SMALLER THAN D REVISION VALIDATION
0002 C 0002 C THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
A = BETWEEN
C C NOTE 3 12 INCH - 24 INCH B = 18 INCH - 24 INCH REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
2/3 AND 3/4 OF D
ST ST
NOTE 3 NOTE 3 A = BETWEEN
NOTE 9 NOTE 9 LARGER THAN 24 INCH B = 24 INCH - 36 INCH
NOTE 3 NOTE 3 NOTE 3 2/3 AND 3/4 OF D DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
NOTE 8 UCH
05/29/20
HJL
05/29/20

REV.NO. DATE REVISION DESCRIPTION DSN

DISCHARGING TO A CLOSED SYSTEM DISCHARGING TO A OPEN SYSTEM C 05/29/20 ISSUED FOR REVIEW 25269
ST STEAM TRAP DEVICE TYPES
HORIZONTAL INSTALLATION HORIZONTAL INSTALLATION JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED
ASSEMBLY DETAIL ST7-X NOTE 5 ASSEMBLY DETAIL ST8-X NOTE 5
A - (THERMOSTATIC) BELLOWS F - (MECHANICAL) FLOAT & LEVER
SAUDI ARABIAN OIL COMPANY
DRAWING TYPE
B - (THERMOSTATIC) BIMETALLIC G - (MECHANICAL) FLOAT & THERMOSTATIC PIPING & INSTRUMENTATION DIAGRAM PID
C - (THERMODYNAMIC) DISC TYPE H - (MECHANICAL) INVERTED BUCKET STEAM TRAP DETAILS STANDARD
D - (THERMODYNAMIC) VENTURI TYPE J - (MECHANICAL) OPEN BUCKET TYPE COMMON AREA
E - (MECHANICAL) BALL FLOAT TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 024 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
1. PUMP SEAL PLAN TO BE CONFIRMED BY VENDOR LATER.
2. INSTRUMENT TAG NUMBER TO BE CONFIRMED LATER.
3. DELETED.
C

LEGEND
PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS -VIBRATION SWITCH
AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
PROCESS LINE
FAILURE STEADY XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
INSTRUMENT
FAILURE STEADY
ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
API PLAN 11/61 (OH) API PLAN 11/61 (BB) DT -DENSITY TRANSMITTER
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
SPECTACLE MOUNTED INSTR.
FV -FLOW CONTROL VALVE
(BV) (BV) PLATE-OPEN FCV -FLOW CONTROL VALVE
BOARD MOUNTED
(SELF-ACTUATED)
FO FO FO SPECTACLE FE -FLOW ELEMENT
INSTRUMENT

PLATE-CLOSED R/G
2 1 FG -FLOW SIGHT GLASS
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)

CHECK VALVE FM -FLOW METER


FO -RESTRICTION ORIFICE MOTOR STATUS
PILOT LIGHT
PLUGGED PLUGGED PLUGGED PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
FR -FLOW RECORDER
QUENCH QUENCH QUENCH BALL VALVE
FT -FLOW TRANSMITTER ML LOCAL MOUNTED
INSTRUMENT
INLET INLET INLET DOUBLE DISC FY -FLOW RELAY
GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
SEAL SEAL SEAL LA -LEVEL ALARM
CHAMBER CHAMBER CHAMBER PRESS.RELIEF VALVE
LV -LEVEL CONTROL VALVE RACK MOUNTED
LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
(SELF-ACTUATED)
LG -LEVEL GAUGE GLASS ELECTRICAL
PLUGGED PLUGGED PLUGGED LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED

QUENCH OUTLET QUENCH OUTLET QUENCH OUTLET VACUUM RELIEF VALVE LI -LEVEL INDICATOR
LR -LEVEL RECORDER INSTRUMENT
LS -LEVEL SWITCH AIR SUPPLY REQUIRED
M MOTOR OPERATED
LT -LEVEL TRANSMITTER
VALVE H
LTD -LEVEL TRANSDUCER HIGH LOW
ML -MOTOR STATUS LIGHT L
P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
PLANT NO. EQUIPMENT TAG NO. SERVICE P&ID NO. FO REMARK PLANT NO. EQUIPMENT TAG NO. SERVICE P&ID NO. FO 1 FO 2 REMARK PC -PRESSURE CONTROLLER FF
C FOUNDATION
CONTROL VALVE PV -PRESS. CONTROL VALVE
PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT
T76 T76-G-0402A/B C DRINKING WATER PUMP CA-033801-003 0001 C 0061 0062 (SELF ACTUATED)
C 0063 0064 P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
0011 CA-033806-003 CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
T76 T76-G-0502A/B/C/D/E OPEN LOOP COOLING WATER PUMP 0065 0066 WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
T76 T76-G-0301A/B/C UTILITY WATER PUMP CA-033802-003 0012 CA-033806-004 (DCS) DISTRIBUTED CONTROL
C 0067 0068 S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
0013 SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
0069 0070
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
0003 PDT -PRESS. DIFF. TRANSMITTER
T76 T76-G-0401A/B C DEMINERALIZED WATER PUMP CA-033803-002 0071 0072 VALVE NORMALLY
PDTD -PRESS. DIFF. TRANSDUCER
SYSTEM, OPERATOR INACCESSIBLE
0004 CLOSED IN CONTROL ROOM
0073 0074 PG -PRESSURE GAUGE
CA-033806-007 PI -PRESSURE INDICATOR (DCS) DISTRIBUTED CONTROL
0002 T76 T76-G-0035A/B/C/D/E CLOSED LOOP COOLING WATER PUMP 0075 0076 PIC -PRESS. INDICATOR CONTROLLER
SYSTEM, OPERATOR INACCESSIBLE
T76 T76-G-0202A/B JOCKEY PUMP CA-033892-002 C CA-033806-008 IN FIELD
0003 0077 0078 PR -PRESSURE RECORDER
C 0079 0080 PS -PRESSURE SWITCH
DISTRIBUTED CONTROL
PT -PRESSURE TRANSMITTER
PX -PRESSURE POINT INTERCONNECTING LOGIC
PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
SI -SPEED INDICATOR CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY
STEAM TRAP DISPLAYED ON CRT
TE -TEMP. ELEMENT
TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER (PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL

REFERENCE DRAWINGS
LETTER IDENTIFICATION OF LINES AD-036204
PIPING SYMBOLS AB-036227
EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950
PIPING LAYOUT INDEX
PLOT PLAN
PROCESS FLOW DIAGRAM
HYDROSTATIC TEST DIAGRAM
DRAWING CONTROL FOR J.O.
INSTRUMENT INSTALLATION SCHEDULES

C 05 29 20

B 02 14 20

A 09 24 19

REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY

REVISION VALIDATION
THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER


(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
05/29/20 05/29/20

REV.NO. DATE REVISION DESCRIPTION DSN


C 05/29/20 ISSUED FOR REVIEW

JOB ORDER/EWO NO.


THIS REVISION IS NOT TO BE USED FOR
10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY


DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
PUMP SEAL PLAN
COMMON AREA
TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 030 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
1. PUMP SEAL PLAN TO BE CONFIRMED BY VENDOR LATER.
2. INSTRUMENT, EQUIPMENT TAG NUMBER AND LINE NUMBER TO BE
CONFIRMED LATER.
C
3. DELETED.
4. PUMPS WITH DUAL PRESSURIZED SEALS(ARRANGEMENT 3) IN
API PLAN 53B WITH AIR FIN COOLER (OH) C TOXIC OR HAZARDOUS SERVICES REGARDLESS OF DRIVER
AUTO MAKE UP SYSTEM (NOTE 5) RATING. FOR OVERHUNG PUMPS, ONLY ONE SEISMIC VIBRATION
TRANSDUCER IS APPLIED.
5. AUTO MAKEUP SYSTEM IS APPLIED AS PER 31-SAMSS-012 AND
VENT
CONFIGURATION IS AS BELOW.
1) AUTO MAKEUP SYSTEM A AND APPLICABLE PUMP ITEM NO.
M - T74-G-9000A/B/C/D (LLP FLARE SEAL DRUM PUMP)
- T74-G-9001A/B/C/D (LP FLARE SEAL DRUM PUMP)
- T74-G-0707A/B/C/D (LP FLARE SEAL DRUM SKIM LIQUID PUMP)
- T74-G-0705A/B/C/D (LP FLARE KO DRUM WATER PUMP)
- T74-G-0704A/B/C/D (LP FLARE KO DRUM HC PUMP)
2) AUTO MAKEUP SYSTEM B AND APPLICABLE PUMP ITEM NO.
- T74-G-0702A/B/C/D/E/F (HP FLARE KO DRUM WATER PUMP)
- T74-G-00004A/B/C/D (LT FLARE KO DRUM PUMP)
H SET @ XXX PSIG - T74-G-0701A/B/C/D/E/F (HP FLARE KO DRUM HC PUMP)
PZI H SET @ X-X" 6. VERTICAL OF HORIZONTAL POSITIVE DISPLACEMENT PUMP
MPS HH SET @ XXX MIL XA LT LI
VT VI VI H SET @ XXX MIL TI L SET @ XXX PSIG SHALL BE USED AS PER AA-036777-001.
LL SET @ XXX PSIG XXX
H SET @ XXX PSIG L SET @ X-X" C
PI

INSTRUMENT L SET @ XXX PSIG


VENDOR

ZC INSTRUMENT
SEAL VENDOR
CHAMBER BY VENDOR BY CONTRACTOR BY VENDOR

FF
TT PI PZT ACCUMULATOR ACCUMULATOR PT HS
BEARING PCV XXX LEGEND
HOUSING PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
1"x3/4" SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS -VIBRATION SWITCH
AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
PROCESS LINE
FAILURE STEADY XL -PILOT LIGHT
DRAIN C -AIR TO OPEN/
INSTRUMENT AO/AFC (NOT FOR MOTOR)
AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
SET @ XXX PSIG AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
INSTRUMENT
FAILURE STEADY
ML ML ELECTRICAL LINE
AOV -AIR OPERATED VALVE DATA LOGGER POINT
PZV PZV F-FLOW P-PRESS.

INPUTS
STOP STOP AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
1 2 DT -DENSITY TRANSMITTER
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
HS HS REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
SPECTACLE MOUNTED INSTR.
FV -FLOW CONTROL VALVE
PLATE-OPEN FCV -FLOW CONTROL VALVE
PLANT NO. EQUIPMENT TAG NO. SERVICE P&ID NO. PZT C PI TT C VT (NOTE 4) PCV SO LINE NO. (NOTE 2) REMARK PI PI (SELF-ACTUATED)
BOARD MOUNTED
START START LT SPECTACLE INSTRUMENT
1 2 PLATE-CLOSED
FE -FLOW ELEMENT
R/G
HS HS FG -FLOW SIGHT GLASS
0175 0176 0029 1201 0054 3/4"-SO-XXXXX-XXXXXXX FHV -FLOW MANUAL CONT. VALVE
STATUS LIGHTS
GATE VALVE XL
0177 0178 0030 1202 0055 3/4"-SO-XXXXX-XXXXXXX R=RED, G=GREEN

T74 T74-G-0702A/B/C/D/E/F HP FLARE KO DRUM WATER PUMP CA-033812-007/008/009 0282 0283 0031 1203 0056 3/4"-SO-XXXXX-XXXXXXX M M GLOBE VALVE
FHTD
FIC
-FLOW MANUAL TRANSDUCER
-FLOW INDICATOR CONTROLLER
PILOT LIGHT (DO NOT
USE FOR MOTOR STATUS)
0284 0285 0032 1204 0057 3/4"-SO-XXXXX-XXXXXXX CHECK VALVE FM -FLOW METER
C C C 0287 0288 0033 1205 0058 3/4"-SO-XXXXX-XXXXXXX FO -RESTRICTION ORIFICE MOTOR STATUS
0289 0290 0034 1206 0059 3/4"-SO-XXXXX-XXXXXXX PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
PILOT LIGHT

C C 0344 0345 0043 1207 0119 3/4"-SO-XXXXX-XXXXXXX BALL VALVE


FR -FLOW RECORDER
LOCAL MOUNTED
C 0346 0347 0044 1208 0120 3/4"-SO-XXXXX-XXXXXXX FT -FLOW TRANSMITTER
ML
INSTRUMENT
T74 T74-G-0705A/B/C/D LP FLARE KO DRUM WATER PUMP CA-033812-019/020 DOUBLE DISC FY -FLOW RELAY
0351 0352 0045 1209 0121 3/4"-SO-XXXXX-XXXXXXX GATE VALVE HIC -HAND INDICATOR CONTROLLER
0353 0354 0046 1210 0122 3/4"-SO-XXXXX-XXXXXXX ANGLE VALVE HS -HAND SWITCH
MOUNTED BEHIND
LOCAL PANEL
0249 0250 0023 1223 0100 3/4"-SO-XXXXX-XXXXXXX LA -LEVEL ALARM
0251 0252 0024 1224 0101 3/4"-SO-XXXXX-XXXXXXX PRESS.RELIEF VALVE
LV -LEVEL CONTROL VALVE RACK MOUNTED

T74 T74-G-0701A/B/C/D/E/F HP FLARE KO DRUM HC PUMP CA-033812-004/005/006 0263 0264 0025 1225 0102 3/4"-SO-XXXXX-XXXXXXX LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)

0265 0266 0026 1226 0103 3/4"-SO-XXXXX-XXXXXXX (SELF-ACTUATED)

C C 0277 0278 0027 1227 0104 3/4"-SO-XXXXX-XXXXXXX LG T74-D-XXXX LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
0279 0280 0028 1228 0105 3/4"-SO-XXXXX-XXXXXXX VACUUM RELIEF VALVE -LEVEL INDICATOR
LI
C C 0319 0320 0039 1229 0216 3/4"-SO-XXXXX-XXXXXXX LR -LEVEL RECORDER INSTRUMENT
0321 0322 0040 1230 0217 3/4"-SO-XXXXX-XXXXXXX M MOTOR OPERATED LS -LEVEL SWITCH AIR SUPPLY REQUIRED
T74 T74-G-0704A/B/C/D LP FLARE KO DRUM HC PUMP CA-033812-017/018 0333 0334 0041 1231 0218 3/4"-SO-XXXXX-XXXXXXX LT -LEVEL TRANSMITTER
VALVE H
0335 0336 0042 1232 0219 3/4"-SO-XXXXX-XXXXXXX LTD -LEVEL TRANSDUCER HIGH LOW
ML -MOTOR STATUS LIGHT L
0371 0471 0076 1233 0449 3/4"-SO-XXXXX-XXXXXXX P MOV -MOTOR OPERATED VALVE
0372 0472 0077 1234 0450 3/4"-SO-XXXXX-XXXXXXX PISTON OPERATED NA -ANNUNCIATOR
T74 T74-G-0004A/B/C/D LT FLARE KO DRUM PUMP CA-033812-027/028 0373 0473 0078 1235 0451 3/4"-SO-XXXXX-XXXXXXX VALVE PB -PUSHBUTTON
TWO PEN RECORDER

0374 0474 0079 1236 0452 3/4"-SO-XXXXX-XXXXXXX PC -PRESSURE CONTROLLER FF

T74-G-XXXXA (NOTE 6) T74-G-XXXXB (NOTE 6) CONTROL VALVE PV


PCV
-PRESS. CONTROL VALVE
-PRESS. CONTROL VALVE
FOUNDATION
FIELDBUS INSTRUMENT
C (SELF ACTUATED)
P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
PI PI PZV PZV PIC -PRESS. INDICATOR CONTROLLER
SYSTEM, OPERATOR INACCESSIBLE
PLANT NO. EQUIPMENT TAG NO. SERVICE LG LT PT REMARK IN FIELD
1 2 1 2 PR -PRESSURE RECORDER
PS -PRESSURE SWITCH
PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
T74 NOTE 2 OIL AUTO MAKE UP PACKAGE 'A' PX -PRESSURE POINT INTERCONNECTING LOGIC
C
PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
T74 NOTE 2 OIL AUTO MAKE UP RESERVOIR 'A' 0091 0475 0476 0091 0092 0092 0477 PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
API PLAN 53B WITH AIR FIN COOLER (OH) RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
T74 NOTE 2 OIL AUTO MAKE UP 'A' PUMP A/B SI -SPEED INDICATOR CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
T74 NOTE 2 OIL AUTO MAKE UP PACKAGE 'B' TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE
VENT T74 NOTE 2 OIL AUTO MAKE UP RESERVOIR 'B' 0093 0478 0479 0093 0094 0094 0480 IBT -INVERTED BUCKET CONTROLLER FUNCTION,
CAN BE NORMALLY
(SELF-ACTUATED)
STEAM TRAP DISPLAYED ON CRT
TE -TEMP. ELEMENT
T74 NOTE 2 OIL AUTO MAKE UP 'B' PUMP A/B TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
M S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER (PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL

H SET @ XXX PSIG


PZI REFERENCE DRAWINGS
MPS HH SET @ XXX MIL HHSET @ XX °F
VT VI VI H SET @ XXX MIL TZI L SET @ XXX PSIG LETTER IDENTIFICATION OF LINES AD-036204
LL SET @ XXX PSIG PIPING SYMBOLS AB-036227
EQUIPMENT SYMBOLS AB-036305
INSTRUMENT SYMBOLS AC-036950
INSTRUMENT
PIPING LAYOUT INDEX
VENDOR
PLOT PLAN
PROCESS FLOW DIAGRAM
ZC ZC
SEAL HYDROSTATIC TEST DIAGRAM
BY VENDOR BY CONTRACTOR FROM AUTO
CHAMBER MAKE UP DRAWING CONTROL FOR J.O.

SYSTEM INSTRUMENT INSTALLATION SCHEDULES

TZT PI PZT ACCUMULATOR


BEARING PCV
HOUSING C 05 29 20

1"x3/4" B 02 14 20

A 09 24 19

DRAIN C REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY

REVISION VALIDATION
THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
XX-XXXXX-XXXX-XXX

DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER


(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
PLANT NO. EQUIPMENT TAG NO. SERVICE P&ID NO. C PZT PI TZT VT (NOTE 4) PCV SO LINE NO. (NOTE 2) REMARK ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
C UCH HJL
05/29/20 05/29/20

C 0435 0436 0059 1211 0453 3/4"-SO-XXXXX-XXXXXXX REV.NO. DATE REVISION DESCRIPTION DSN
0437 0438 0060 1212 0454 3/4"-SO-XXXXX-XXXXXXX
T74 T74-G-9000A/B/C/D LLP FLARE SEAL DRUM PUMP CA-033812-042/043 0445 0446 0061 1213 0455 3/4"-SO-XXXXX-XXXXXXX C 05/29/20 ISSUED FOR REVIEW

0447 0448 0062 1214 0456 3/4"-SO-XXXXX-XXXXXXX


JOB ORDER/EWO NO.
0395 0396 0051 1215 0457 3/4"-SO-XXXXX-XXXXXXX THIS REVISION IS NOT TO BE USED FOR
0397 0398 0052 1216 0458 3/4"-SO-XXXXX-XXXXXXX 10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED
T74 T74-G-9001A/B/C/D LP FLARE SEAL DRUM PUMP CA-033812-037/038 0405 0406 0053 1217 0459 3/4"-SO-XXXXX-XXXXXXX
0407 0408 0054 1218 0460 3/4"-SO-XXXXX-XXXXXXX SAUDI ARABIAN OIL COMPANY
0415 0416 0055 1219 0461 3/4"-SO-XXXXX-XXXXXXX DRAWING TYPE
C 0417 0418 0056 1220 0462 3/4"-SO-XXXXX-XXXXXXX PIPING & INSTRUMENTATION DIAGRAM PID
T74 T74-G-0707A/B/C/D LP FLARE SEAL DRUM SKIM LIQUID PUMP CA-033812-039/040 0425 0426 0057 1221 0463 3/4"-SO-XXXXX-XXXXXXX
0427 0428 0058 1222 0464 3/4"-SO-XXXXX-XXXXXXX PUMP SEAL PLAN
C C COMMON AREA
TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 031 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
1. PUMP SEAL PLAN TO BE CONFIRMED BY VENDOR LATER.
2. INSTRUMENT, EQUIPMENT TAG NUMBER AND LINE NUMBER TO BE
CONFIRMED LATER.
C
3. DELETED.
4. PIPING CLASS BASED ON VENDOR INFORMATION.

API PLAN 13/61 API PLAN 31/13/61

(BV) FO
FO 1
1 LEGEND
PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS -VIBRATION SWITCH
AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
PROCESS LINE
PLUGGED FAILURE STEADY XL -PILOT LIGHT
INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
QUENCH AIR FAILURE CLOSE
AIR LINE XS -LIMIT SWITCH
INLET PLUGGED AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
INSTRUMENT
FAILURE STEADY
(QUENCH) ELECTRICAL LINE
AOV -AIR OPERATED VALVE DATA LOGGER POINT
SEAL F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
CHAMBER SEAL DT -DENSITY TRANSMITTER
X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
CHAMBER FC - FLOW CONTROLLER
LOCAL PANEL
MOUNTED INSTR.
SPECTACLE FV -FLOW CONTROL VALVE
PLUGGED PLATE-OPEN FCV -FLOW CONTROL VALVE
BOARD MOUNTED
QUENCH OUTLET PLUGGED (SELF-ACTUATED) INSTRUMENT
SPECTACLE FE -FLOW ELEMENT
(DRAIN) PLATE-CLOSED R/G
VENDOR FG -FLOW SIGHT GLASS
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL R=RED, G=GREEN
PIPING FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)

CHECK VALVE FM -FLOW METER


FO -RESTRICTION ORIFICE MOTOR STATUS
PILOT LIGHT
PLANT NO. EQUIPMENT TAG NO. SERVICE P&ID NO. FO REMARK DRAIN PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
FR -FLOW RECORDER
C BALL VALVE
FT -FLOW TRANSMITTER
ML LOCAL MOUNTED
INSTRUMENT
DOUBLE DISC FY -FLOW RELAY
C T76 C T76-G-0006A/B DELUGE PUMP CA-033811-029 NOTE 2 GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
T76 T76-G-0005A/B OILY WATER PUMP CA-033811-029 NOTE 2 LA -LEVEL ALARM
LV -LEVEL CONTROL VALVE RACK MOUNTED
T74 T74-G-0701A/B/C DELUGE PUMP CA-033811-023 NOTE 2 PRESS.RELIEF VALVE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
(SELF-ACTUATED)
T74 T74-G-0702A/B/C DELUGE PUMP CA-033811-024 NOTE 2 LG -LEVEL GAUGE GLASS ELECTRICAL
PLANT NO. EQUIPMENT TAG NO. SERVICE P&ID NO. FO DRAIN LINE NO. (NOTE 2) REMARK LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED

T74 T74-G-0704A/B OILY WATER PUMP CA-033811-024 NOTE 2 VACUUM RELIEF VALVE LI -LEVEL INDICATOR
LR -LEVEL RECORDER INSTRUMENT

T74 T74-G-0703A/B OILY WATER PUMP CA-033811-023 NOTE 2 T78 T78-G-0906A/B FILTRATION FEED PUMP CA-033811-004 NOTE 2 1"-WW-XXXX-1LEOU01 (HOLD) NOTE 1 M MOTOR OPERATED LS -LEVEL SWITCH AIR SUPPLY REQUIRED

LT -LEVEL TRANSMITTER
VALVE H
-LEVEL TRANSDUCER
C C C C LTD HIGH LOW
C ML -MOTOR STATUS LIGHT L
P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
VALVE PB -PUSHBUTTON
PC -PRESSURE CONTROLLER FF
CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT

(SELF ACTUATED)
P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
PG -PRESSURE GAUGE
PI (DCS) DISTRIBUTED CONTROL
-PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
IN FIELD
PR -PRESSURE RECORDER
PS -PRESSURE SWITCH

C
API PLAN 31/61 C PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
PX -PRESSURE POINT INTERCONNECTING LOGIC
PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
API PLAN 32/61 SI -SPEED INDICATOR CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE
(BV) TCV -TEMP. CONTROL VALVE
(PLC) PROGRAMMABLE LOGIC
CONTROLLER FUNCTION,
IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY
FI FO PI STEAM TRAP
TE -TEMP. ELEMENT DISPLAYED ON CRT
TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
UTILITY WATER TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
(PLUGGED) S -DRAIN TO
TR -TEMP. RECORDER
PRESSURE SEWER (PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
QUENCH V -VENT TW -THERMOWELL

(PLUGGED) (PLUGGED)
VENDOR REFERENCE DRAWINGS
LETTER IDENTIFICATION OF LINES AD-036204
PIPING
1" PIPING SYMBOLS AB-036227
EQUIPMENT SYMBOLS AB-036305

DRAIN INSTRUMENT SYMBOLS AC-036950

(PLUGGED) DRAIN PIPING LAYOUT INDEX

1 PLOT PLAN
PROCESS FLOW DIAGRAM
HYDROSTATIC TEST DIAGRAM
DRAWING CONTROL FOR J.O.
INSTRUMENT INSTALLATION SCHEDULES
PLANT NO. EQUIPMENT TAG NO. SERVICE P&ID NO. FO FI PI UW LINE NO. (NOTE 2) REMARK
PLANT NO. EQUIPMENT TAG NO. SERVICE P&ID NO. C DRAIN LINE NO. REMARK
1"-UW-XXXXX-1CS2W01
T76 T76-G-XXXXA/B (NOTE 2) FILTER BACKWASH SUMP PUMPS CA-033806-010 NOTE 2 NOTE 2 NOTE 2 NOTE 1 C 05 29 20
1"-UW-XXXXX-1CS2W01 T74 T74-G-0709A/B DEOLED WATER TRANSFER PUMP CA-033811-037 1"-WW-XXXX-1LEOU01
B 02 14 20
1"-UW-00802-1CS2W01
T78 T78-G-0907A/B FILTRATION BACKWASH PUMPS CA-033811-040 NOTE 2 NOTE 2 NOTE 2 NOTE 1 A 09 24 19
1"-UW-00803-1CS2W01
REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY

REVISION VALIDATION
THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
XX-XXXXX-XXXX-XXX

DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER


(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
05/29/20 05/29/20

REV.NO. DATE REVISION DESCRIPTION DSN


C 05/29/20 ISSUED FOR REVIEW

JOB ORDER/EWO NO.


THIS REVISION IS NOT TO BE USED FOR
10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY


DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
PUMP SEAL PLAN
COMMON AREA
TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

T80 A CA-033800 032 C


Saudi Aramco 5994 ENG. (09/03)

DOC CLASS: 2
RESTRICTED SMART CADD-05
NOTES:
1. PRESSURE GAUGE RANGE
- UTILITY WATER : X-XXX PSIG
- DEMIN. WATER : X-XXX PSIG
- NITROGEN : X-XXX PSIG
- UTILITY AIR : X-XXX PSIG
UTILITY STATION LIST UTILITY STATION LIST - LP STEAM : X-XXX PSIG
2. INSTRUMENT TAG NUMBER TO BE CONFIRMED LATER.

PLANT NO. UNIT NO. UTILITY STATION NO. P&ID NO. UTILITY WATER DEMIN. WATER NITROGEN UTILITY AIR LP STEAM REMARK PLANT NO. UNIT NO. UTILITY STATION NO. P&ID NO. UTILITY WATER DEMIN. WATER NITROGEN UTILITY AIR LP STEAM REMARK
T76 63 US-T76-3-01 NOTE 2 NOTE 2 NOTE 2 T74 48 US-T74-1-02 NOTE 2 NOTE 2 NOTE 2 NOTE 2
T76 63 US-T76-3-02 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 48 US-T74-1-03 UTILITY WATER : CA-033811-081 NOTE 2 NOTE 2 NOTE 2 NOTE 2
NITROGEN : CA-033811-082
T76 63 US-T76-3-03 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 48 US-T74-1-04 NOTE 2 NOTE 2 NOTE 2 NOTE 2
UTILITY AIR : CA-033811-083
T76 63 US-T76-3-04 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 48 US-T74-1-05 LP STEAM : CA-033811-085 NOTE 2 NOTE 2 NOTE 2 NOTE 2
T76 63 US-T76-3-05 UTILITY WATER : CA-033802-052 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 48 US-T74-1-06 NOTE 2 NOTE 2 NOTE 2 NOTE 2
NITROGEN : CA-033802-053
T76 63 US-T76-3-06 NOTE 2 NOTE 2 NOTE 2 NOTE 2
UTILITY AIR : CA-033802-054 T78 59 US-T78-1-21 NOTE 2 NOTE 2 NOTE 2 NOTE 2
LP STEAM : CA-033802-055 UTILITY WATER : CA-033811-091
T76 63 US-T76-3-07 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NITROGEN : CA-033811-092
T76 63 US-T76-3-08 NOTE 2 NOTE 2 NOTE 2 NOTE 2 UTILITY AIR : CA-033811-093
T78 59 US-T78-1-22 LP STEAM : CA-033811-095 NOTE 2 NOTE 2 NOTE 2 NOTE 2
T76 63 US-T76-3-09 NOTE 2 NOTE 2 NOTE 2 NOTE 2
T76 63 US-T76-3-10 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-11 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2
T76 63 US-T76-3-11 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-12 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2
T76 65 US-T76-2-01 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-13 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2
T76 65 US-T76-2-02 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-14 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2
T76 65 US-T76-2-03 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-15 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2
T76 65 US-T76-2-04 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-16 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 LEGEND
PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
T76 65 US-T76-2-05 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-17 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
AIR FAILURE OPEN VS -VIBRATION SWITCH
T76 65 US-T76-2-06 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-18 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 PROCESS LINE AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
FAILURE STEADY XL -PILOT LIGHT
T76 65 US-T76-2-07 UTILITY WATER : CA-033806-052 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-19 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 INSTRUMENT AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
DEMIN. WATER : CA-033806-053 AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
T76 65 US-T76-2-08 NITROGEN : CA-033806-054 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-20 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 INSTRUMENT
AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
FAILURE STEADY
UTILITY AIR : CA-033806-055 ELECTRICAL LINE
AOV DATA LOGGER POINT
-AIR OPERATED VALVE
T76 65 US-T76-2-09 LP STEAM : CA-033806-057 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-21 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 F-FLOW P-PRESS.

INPUTS
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
DT -DENSITY TRANSMITTER
T76 65 US-T76-2-10 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-22 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 X-MISC. A-ALARM

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
REDUCER ESD -EMER. SHUTDOWN SYSTEM
LOCAL PANEL
FC - FLOW CONTROLLER
T76 65 US-T76-2-11 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-23 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 SPECTACLE FV -FLOW CONTROL VALVE
MOUNTED INSTR.

PLATE-OPEN FCV -FLOW CONTROL VALVE


T76 65 US-T76-2-12 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-24 UTILITY WATER : CA-033812-151 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 (SELF-ACTUATED)
BOARD MOUNTED
INSTRUMENT
SPECTACLE
NITROGEN : CA-033812-152 PLATE-CLOSED
FE -FLOW ELEMENT
R/G
T76 65 US-T76-2-13 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-25 UTILITY AIR : CA-033812-154 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 FG -FLOW SIGHT GLASS
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL
LP STEAM : CA-033812-158 R=RED, G=GREEN
T76 65 US-T76-2-14 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-26 DEMIN. WATER : CA-033812-161 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 GLOBE VALVE
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
FM -FLOW METER
T76 65 US-T76-2-15 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-27 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 CHECK VALVE
FO -RESTRICTION ORIFICE MOTOR STATUS
PILOT LIGHT
PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
T76 68 US-T76-1-01 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-28 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 FR -FLOW RECORDER
BALL VALVE ML LOCAL MOUNTED
FT -FLOW TRANSMITTER INSTRUMENT
T76 68 US-T76-1-02 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-29 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 DOUBLE DISC FY -FLOW RELAY
GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
T76 68 US-T76-1-03 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-30 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
LA -LEVEL ALARM
T76 68 US-T76-1-04 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-31 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 PRESS.RELIEF VALVE
LV -LEVEL CONTROL VALVE RACK MOUNTED
LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)

T76 68 US-T76-1-05 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-32 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 (SELF-ACTUATED)
LG -LEVEL GAUGE GLASS ELECTRICAL
LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
T76 68 US-T76-1-06 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-33 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 VACUUM RELIEF VALVE LI -LEVEL INDICATOR

T76 68 US-T76-1-07 UTILITY WATER : CA-033807-052 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-34 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2
LR -LEVEL RECORDER INSTRUMENT
AIR SUPPLY REQUIRED
LS -LEVEL SWITCH
DEMIN. WATER : CA-033807-053 M MOTOR OPERATED
-LEVEL TRANSMITTER
VALVE LT
T76 68 US-T76-1-08 NITROGEN : CA-033807-055 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-35 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 LTD -LEVEL TRANSDUCER
H
HIGH LOW
UTILITY AIR : CA-033807-056 ML -MOTOR STATUS LIGHT L
T76 68 US-T76-1-09 LP STEAM : CA-033807-058 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-36 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 P MOV -MOTOR OPERATED VALVE
PISTON OPERATED NA -ANNUNCIATOR TWO PEN RECORDER
T76 68 US-T76-1-10 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-37 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 VALVE PB -PUSHBUTTON
PC -PRESSURE CONTROLLER FF
CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
T76 68 US-T76-1-11 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-38 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT

(SELF ACTUATED)
T76 68 US-T76-1-12 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-39 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
T76 68 US-T76-1-13 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T74-1-40 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
(DCS) DISTRIBUTED CONTROL
S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
T76 68 US-T76-1-14 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T78-1-01 NOTE 2 NOTE 2 NOTE 2 SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
T76 68 US-T76-1-15 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T78-1-02 NOTE 2 NOTE 2 NOTE 2 VALVE NORMALLY
PDT -PRESS. DIFF. TRANSMITTER
SYSTEM, OPERATOR INACCESSIBLE
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
CLOSED
T76 67 US-T76-2-17 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T78-1-03 NOTE 2 NOTE 2 NOTE 2 PG -PRESSURE GAUGE
(DCS) DISTRIBUTED CONTROL
PI -PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER
T76 67 US-T76-2-18 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T78-1-04 NOTE 2 NOTE 2 NOTE 2 NOTE 2 PR -PRESSURE RECORDER
IN FIELD

PS -PRESSURE SWITCH
T76 67 US-T76-2-19 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T78-1-05 NOTE 2 NOTE 2 NOTE 2 NOTE 2 PT -PRESSURE TRANSMITTER DISTRIBUTED CONTROL
UTILITY WATER : CA-033808-052 UTILITY WATER : CA-033812-151 PX -PRESSURE POINT INTERCONNECTING LOGIC
T76 67 US-T76-2-20 NITROGEN : CA-033808-054 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T78-1-06 NITROGEN : CA-033812-153 NOTE 2 NOTE 2 NOTE 2 PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
UTILITY AIR : CA-033808-055 UTILITY AIR : CA-033812-155 PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
T76 67 US-T76-2-21 LP STEAM : CA-033808-057 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T78-1-07 NOTE 2 NOTE 2 NOTE 2 RTD -RESIST. TEMP. DETECTOR
LP STEAM : CA-033812-159 SI -SPEED INDICATOR
(PLC) PROGRAMMABLE LOGIC
CONTROLLER, NORMALLY
T76 67 US-T76-2-22 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T78-1-08 NOTE 2 NOTE 2 NOTE 2 SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS

T76 67 US-T76-2-23 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T78-1-09 NOTE 2 NOTE 2 NOTE 2 TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
IBT -INVERTED BUCKET
(SELF-ACTUATED) CAN BE NORMALLY
T76 67 US-T76-2-24 NOTE 2 NOTE 2 NOTE 2 NOTE 2 T74 47 US-T78-1-10 NOTE 2 NOTE 2 NOTE 2 STEAM TRAP
TE -TEMP. ELEMENT DISPLAYED ON CRT
TSO -TIGHT SHUT OFF TG -THERMOMETER LOCAL DCS OR AUXILIARY
T74 47 US-T78-1-11 NOTE 2 NOTE 2 NOTE 2 S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
T74 47 US-T78-1-12 NOTE 2 NOTE 2 NOTE 2 PRESSURE SEWER TR -TEMP. RECORDER
(PLC) PROGRAMMABLE LOGIC
TS -TEMP. SWITCH
-OILY WATER SEWER CONTROLLER I/O POINT
OWS TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
V -VENT TW -THERMOWELL

SAFETY SHOWER & EYE WASH FLOW SWITCH LIST


REFERENCE DRAWINGS
LETTER IDENTIFICATION OF LINES AD-036204

PLANT NO. UNIT NO. FLOW SWITCH NO. SSEW, EW NO. P&ID NO. PIPING SYMBOLS AB-036227
EQUIPMENT SYMBOLS AB-036305
T76 60 FSH-0131 SSEW-T76-3-01 CA-033802-051 INSTRUMENT SYMBOLS AC-036950

T76 60 FSH-0132 SSEW-T76-3-02 CA-033802-051 PIPING LAYOUT INDEX


PLOT PLAN
T76 60 FSH-0133 SSEW-T76-3-03 CA-033802-051 PROCESS FLOW DIAGRAM

T76 60 FSH-0134 - CA-033802-051 HYDROSTATIC TEST DIAGRAM


DRAWING CONTROL FOR J.O.
T76 60 FSH-0135 SSEW-T76-3-04 CA-033802-051 INSTRUMENT INSTALLATION SCHEDULES

T76 63 FSH-0051 SSEW-T76-3-05 CA-033802-051


T76 65 FSH-0141 SSEW-T76-2-01 CA-033806-051
T76 65 FSH-0142 SSEW-T76-2-02 CA-033806-051
T76 60 FSH-0136 SSEW-T76-2-04 CA-033808-051 A 05 29 20

T76 60 FSH-0137 SSEW-T76-2-03 CA-033808-051 REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY

T76 60 FSH-0138 SSEW-T76-1-01 CA-033807-051 REVISION VALIDATION


THIS REVISION NO. IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
T76 60 FSH-0139 EW-T76-1-02 CA-033807-051
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
T76 60 FSH-0140 EW-T76-1-03 CA-033807-051
T76 60 FSH-0141 EW-T76-1-04 CA-033807-051 DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
T80 00 FSH-0051 EW-T79-3-01 CA-033801-100 ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
UCH HJL
T80 00 FSH-0052 EW-T79-3-02 CA-033801-100 05/29/20 05/29/20

REV.NO. DATE REVISION DESCRIPTION DSN


T80 00 FSH-0053 EW-T79-3-03 CA-033801-100
A 05/29/20 ISSUED FOR REVIEW

T80 00 FSH-0054 EW-T79-3-04 CA-033801-100


JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
T80 00 FSH-0055 EW-T79-3-05 CA-033801-100 10-09003-0005 CONSTRUCTION UNTIL CERTIFIED AND DATED

T80 00 FSH-0056 EW-T79-3-06 CA-033801-100 SAUDI ARABIAN OIL COMPANY


DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
PI LIST FOR UTILITY STATION
COMMON AREA
TANAJIB SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

A T80 A CA-033800 041 A


Saudi Aramco 5994 ENG. (09/03)