You are on page 1of 20

1.

WL CALCULATION

Location: Lot 299 #1 Pinderi Crescent, Dampier


Occupancy: Miscellaneous - Boatport
Terrain: Category 2
Region: D

Design Wind Speed:


Vsit,β = VRMdMz,catMsMt
Design Wind Pressure:
p=0.5⍴air(Vdes,θ)2CfigCdyn

Regional Wind Speed, VR


Consider 50-year design working life; FD = 1.0 for serviceability limit states
VR = 60m/s

IMPORTANCE LEVEL = 1

Wind Direction Multiplier, Md

Conservatively take Md as 1.0

Mz,cat
Consider z = 5m (to be applied on roof and walls), Mz,cat = 0.91

Conservatively assume shielding multiplier, Ms to be 1.0


Topographic Multiplier is assumed to be 1.0; No topographic details provided

VR = 60 m/s
Md = 1
Mz,cat = 0.91
Ms = 1
Mt = 1
Vsit,β = 54.6 m/s

Cp,i = -0.3, 0
Cp,e = 0.7

Cp,e = -0.3

x = 4+0.636+0.636
x = 5.272
h = 5.0
x/h = 1.05
Cp,e = -0.5
b/d = 2.276 b= 12
h/d = 0.948 h= 5
d/b = 0.439 d= 5.272
*Since h/d is almost equal to 1, no interpolation is considered.

Cp,e for windward & leeward wall surfaces

Cp,e windward = 0.7


Cp,e leeward = 0.3

Cp,e for sidewall surfaces


Cp,e windward = -0.5

Cp,e for sidewall surfaces


Upwind = -1.0, -0.5
Downwind = -0.6

NO AREA REDUCTION WILL BE CONSIDERED.


Action Combination Factors, Kc,i and Kc,e

SINCE ONE WALL IS OPEN, THIS IS APPLICABLE!

Design pressure values for windward wall.


height, m Mz,cat Vdes,θ Cfig Cp,e Ka Kc,e Kl
5 0.91 54.6 0.56 0.7 1 0.8 1
Note: density of air is taken as 1.2kg/cu.m & Cdyn as 1.0

Calculated design pressure values for leeward and side walls, and roof surfaces.
Mz,cat Vdes,θ Cfig Cp,e Ka Kc,e Kl
Leeward 0.91 54.6 0.24 0.3 1 0.8 1
Sidewall 0.91 54.6 -0.4 -0.5 1 0.8 1
0.91 54.6 -0.8 -1 1 0.8 1
Roof upwind
0.91 54.6 -0.4 -0.5 1 0.8 1
Roof downwind 0.91 54.6 -0.48 -0.6 1 0.8 1

Frame modulation = 4000 mm Half Load


Windward Load = 4.01 2.00
Leeward Load = 1.72 0.86
Sidewall Load = -2.86 -1.43
Rood upwind Load = -5.72 -2.86
Rood upwind Load = -2.86 -1.43
Kp Design Pressure p, Pa
1 1001.67

Kp Design Pressure p, Pa
1 429.29
1 -715.48
1 -1430.96
1 -715.48
1 -858.57
ALL FRAMES PASSED STRESS CHECK
H/500 = 4500/500
H/500 = 9
Actual Sway = 7.31
Utilization = 0.81
PORTAL FRAME IS ADEQUATE AGAINST SW
H/500 =
H/500 =
Actual Sway =
Utilization =
PORTAL FRAME IS ADEQUATE A
PASSED STRESS CHECK
mm
mm

ADEQUATE AGAINST SWAY.


4500/500
9 mm
7.94 mm
0.88
L FRAME IS ADEQUATE AGAINST SWAY.