Report SuoiNgoTanChau 09 Nos BP92 Vs JA 405W (112 String 20)
Report SuoiNgoTanChau 09 Nos BP92 Vs JA 405W (112 String 20)
PVsyst TRIAL
Simulation variant :
Simulation parameters
Collector Plane Orientation
9 nos BP 92 vs JA 405 (112 string 20)
Simulation date
System type
Tilt
10/09/20 22h12
PVsyst TRIAL
PV Array Characteristics
PV module Si-mono Model JAM72S10-405/MR/1500V
Custom parameters definition Manufacturer JA Solar
Number of PV modules In series 20 modules In parallel 112 strings
Total number of PV modules Nb. modules 2240 Unit Nom. Power 405 Wp
Array global power Nominal (STC) 907 kWp At operating cond. 811 kWp (55°C)
Array operating characteristics (50°C) U mpp 731 V I mpp 1110 A
Total area Module area 4496 m² Cell area 4038 m²
PVsyst TRIAL
Pnom ratio 1.10
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.88 10/09/20 Page 2/5
PVsyst TRIAL
Inverter pack Nb. of units 9.0 Pnom total 828 kW ac
User's needs Unlimited load (grid)
Normalized productions (per installed kWp): Nominal power 907 kWp Performance Ratio PR
7 1.0
Lc : Collection Loss (PV-array losses) 0.7 kWh/kWp/day PR : Performance Ratio (Yf / Yr) : 0.851
0.9
Ls : System Loss (inverter, ...) 0.09 kWh/kWp/day
6
Yf : Produced useful energy (inverter output) 4.52 kWh/kWp/day
0.8
[kWh/kWp/day]
5 0.7
Performance Ratio PR
PVsyst TRIAL
0.6
4
Energy
0.5
3
0.4
Normalized
2 0.3
0.2
1
0.1
0 0.0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
0.849
0.846
0.840
0.840
May 172.2 84.14 28.99 160.9 158.3 126.2 123.8 0.848
June 171.7 81.50 28.08 156.5 153.8 123.8 121.5 0.856
July 174.6 84.33 27.93 160.8 158.1 127.2 124.8 0.856
August 166.3 84.81 27.69 158.8 156.2 125.6 123.2 0.855
September 138.8 71.95 26.97 139.7 137.8 110.4 108.2 0.854
October 148.7 75.34 27.06 157.8 155.9 124.9 122.4 0.855
November 147.7 66.08 26.53 164.5 162.7 130.2 127.7 0.856
Legends: GlobHor
DiffHor
T_Amb
145.1
1903.3
63.98
886.03
GlobEff
EArray
E_Grid
130.7
1525.1
128.2
1495.6
0.856
0.851
PVsyst TRIAL
Inverter pack Nb. of units 9.0 Pnom total 828 kW ac
User's needs Unlimited load (grid)
7000
Values from 01/01 to 31/12
6000
Energy injected into grid [kWh/day]
5000
4000
2000
1000
0
0 2 4 6 8 10
Global incident in coll. plane [kWh/m².day]
PVsyst TRIAL
System Output Power Distribution
50000
Values from 01/01 to 31/12
Energy injected into grid [kWh / Bin]
40000
30000
20000
0
0 200 400 600 800
Power injected into grid [kW]
PVsyst TRIAL
Inverter pack Nb. of units 9.0 Pnom total 828 kW ac
User's needs Unlimited load (grid)
PVsyst TRIAL 1738 MWh Array nominal energy (at STC effic.)
-0.18% PV loss due to irradiance level
+0.31%
-1.10%
Module quality loss
PVsyst TRIAL
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
-0.03% Night consumption
1496 MWh Available Energy at Inverter Output
1496 MWh Energy injected into grid
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.88 10/09/20 Page 5/5
PVsyst TRIAL
Inverter pack Nb. of units 9.0 Pnom total 828 kW ac
User's needs Unlimited load (grid)
The probability distribution variance is also depending on some system parameters uncertainties
PVsyst TRIAL
Specified Deviation PV module modelling/parameters 1.0 %
Inverter efficiency uncertainty 0.5 %
Soiling and mismatch uncertainties 1.0 %
Degradation uncertainty 1.0 %
Global variability (meteo + system) Variance 2.7 % (quadratic sum)
Probability distribution
PVsyst TRIAL
0.50
0.45
P50 = 1495601 kWh
0.40 E_Grid simul = 1495601 kWh
0.35
0.30
Probability
0.25
0.20
P90 = 1443963 kWh
0.15
0.05
PVsyst TRIAL
0.00
1350000 1400000 1450000 1500000 1550000 1600000 1650000
E_Grid system production kWh