Professional Documents
Culture Documents
Date: 21-02-2021
DL01-20W
DL-03-14W
DL-03-25W
Date 21-Feb-21
Content
Site 1 - Building 1
Storey 1
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Calculation objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 .............................
bath
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
.............................
Bath
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
.............................
Bath / Luminance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 .............................
Bath
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
.............................
Bath
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
.............................
SASREF HOUSING PROJECT PHASE2
Content
Bed 3
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
.............................
Bed 4
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
.............................
Bed 5
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
.............................
Coffee Counter
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
.............................
Cuo-Dress
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
.............................
Dress
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
.............................
Family Lounge
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
.............................
SASREF HOUSING PROJECT PHASE2
Content
Master Bed
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
.............................
Room 9
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
.............................
Room 10
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
.............................
Room 11
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
.............................
Toilet
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
.............................
Wash
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
.............................
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
.............................
SASREF HOUSING PROJECT PHASE2
Images
5
SASREF HOUSING PROJECT PHASE2
P 20.0 W
ΦLuminaire 2000 lm
CCT 3000 K
Polar LDC
CRI 100
6
SASREF HOUSING PROJECT PHASE2
NLC RECESSED-DOWNLIGHT
P 14.0 W
ΦLuminaire 1680 lm
CCT 3000 K
Polar LDC
CRI 100
7
SASREF HOUSING PROJECT PHASE2
NLC RECESSED-DOWNLIGHT
P 25.0 W
ΦLuminaire 2500 lm
CCT 3000 K
Polar LDC
CRI 100
8
SASREF HOUSING PROJECT PHASE2
Building 1 · Storey 1
Luminaire list
9
SASREF HOUSING PROJECT PHASE2
Building 1 · Storey 1
Calculation objects
10
SASREF HOUSING PROJECT PHASE2
Building 1 · Storey 1
Calculation objects
Work planes
11
SASREF HOUSING PROJECT PHASE2
Building 1 · Storey 1
Calculation objects
Surface result object 2 (Floor/ceiling) 20.6 cd/m² 9.82 cd/m² 30.8 cd/m² 0.48 0.32
Luminance
Height: 0.000 m
12
SASREF HOUSING PROJECT PHASE2
Building 1 · Storey 1
Calculation objects
Surface result object 3 (Floor/ceiling) 9.37 cd/m² 7.44 cd/m² 10.9 cd/m² 0.79 0.68
Luminance
Height: 0.000 m
Surface result object 4 (Floor/ceiling) 21.2 cd/m² 10.1 cd/m² 31.6 cd/m² 0.48 0.32
Luminance
Height: 0.000 m
Surface result object 5 (Floor/ceiling) 29.7 cd/m² 16.5 cd/m² 37.5 cd/m² 0.56 0.44
Luminance
Height: 0.000 m
Surface result object 6 (Floor/ceiling) 17.4 cd/m² 13.8 cd/m² 20.0 cd/m² 0.79 0.69
Luminance
Height: 0.000 m
Surface result object 7 (Floor/ceiling) 9.77 cd/m² 8.01 cd/m² 11.1 cd/m² 0.82 0.72
Luminance
Height: 0.000 m
Surface result object 8 (Floor/ceiling) 24.7 cd/m² 10.5 cd/m² 32.9 cd/m² 0.43 0.32
Luminance
Height: 0.000 m
13
SASREF HOUSING PROJECT PHASE2
Building 1 · Storey 1
Calculation objects
Surface result object 9 (Floor/ceiling) 19.3 cd/m² 10.3 cd/m² 22.9 cd/m² 0.53 0.45
Luminance
Height: 0.000 m
Surface result object 10 (Floor/ceiling) 15.4 cd/m² 10.5 cd/m² 18.1 cd/m² 0.68 0.58
Luminance
Height: 0.000 m
Surface result object 11 (Floor/ceiling) 21.7 cd/m² 14.8 cd/m² 26.2 cd/m² 0.68 0.56
Luminance
Height: 0.000 m
Surface result object 12 (Floor/ceiling) 23.2 cd/m² 14.5 cd/m² 28.1 cd/m² 0.63 0.52
Luminance
Height: 0.000 m
Surface result object 13 (Floor/ceiling) 9.69 cd/m² 7.80 cd/m² 11.1 cd/m² 0.80 0.70
Luminance
Height: 0.000 m
Surface result object 14 (Floor/ceiling) 9.79 cd/m² 7.98 cd/m² 11.1 cd/m² 0.82 0.72
Luminance
Height: 0.000 m
14
SASREF HOUSING PROJECT PHASE2
Building 1 · Storey 1
Calculation objects
Surface result object 15 (Floor/ceiling) 10.2 cd/m² 8.84 cd/m² 11.3 cd/m² 0.87 0.78
Luminance
Height: 0.000 m
Surface result object 16 (Floor/ceiling) 9.83 cd/m² 8.09 cd/m² 11.2 cd/m² 0.82 0.72
Luminance
Height: 0.000 m
Surface result object 17 (Floor/ceiling) 9.81 cd/m² 7.36 cd/m² 11.6 cd/m² 0.75 0.63
Luminance
Height: 0.000 m
15
SASREF HOUSING PROJECT PHASE2
Ground area: 6.82 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 16
SASREF HOUSING PROJECT PHASE2
Results
g1 0.58 S31
2.53 W/m²/100 lx
Luminaire list
17
SASREF HOUSING PROJECT PHASE2
Ground area: 4.12 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 18
SASREF HOUSING PROJECT PHASE2
Results
g1 0.68 S2
3.03 W/m²/100 lx
Luminaire list
19
SASREF HOUSING PROJECT PHASE2
20
SASREF HOUSING PROJECT PHASE2
Ground area: 3.79 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 21
SASREF HOUSING PROJECT PHASE2
Results
g1 0.74 S11
3.08 W/m²/100 lx
Luminaire list
22
SASREF HOUSING PROJECT PHASE2
Ground area: 3.26 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 23
SASREF HOUSING PROJECT PHASE2
Results
g1 0.72 S29
3.10 W/m²/100 lx
Luminaire list
24
SASREF HOUSING PROJECT PHASE2
Ground area: 24.97 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 25
SASREF HOUSING PROJECT PHASE2
Results
g1 0.29 S4
1.46 W/m²/100 lx
Luminaire list
26
SASREF HOUSING PROJECT PHASE2
Ground area: 24.23 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 27
SASREF HOUSING PROJECT PHASE2
Results
g1 0.30 S9
1.46 W/m²/100 lx
Luminaire list
28
SASREF HOUSING PROJECT PHASE2
Ground area: 18.26 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 29
SASREF HOUSING PROJECT PHASE2
Results
g1 0.35 S15
1.72 W/m²/100 lx
Luminaire list
30
SASREF HOUSING PROJECT PHASE2
Ground area: 8.34 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 31
SASREF HOUSING PROJECT PHASE2
Results
g1 0.58 S35
1.53 W/m²/100 lx
Luminaire list
32
SASREF HOUSING PROJECT PHASE2
Ground area: 3.72 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 33
SASREF HOUSING PROJECT PHASE2
Results
g1 0.71 S6
2.86 W/m²/100 lx
Luminaire list
34
SASREF HOUSING PROJECT PHASE2
Ground area: 3.20 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 35
SASREF HOUSING PROJECT PHASE2
Results
g1 0.72 S13
3.13 W/m²/100 lx
Luminaire list
36
SASREF HOUSING PROJECT PHASE2
Ground area: 12.88 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 37
SASREF HOUSING PROJECT PHASE2
Results
g1 0.62 S33
1.98 W/m²/100 lx
Luminaire list
38
SASREF HOUSING PROJECT PHASE2
Ground area: 33.66 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 39
SASREF HOUSING PROJECT PHASE2
Results
g1 0.64 S23
1.53 W/m²/100 lx
Luminaire list
40
SASREF HOUSING PROJECT PHASE2
Ground area: 25.03 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 41
SASREF HOUSING PROJECT PHASE2
Results
g1 0.50 S17
1.57 W/m²/100 lx
Luminaire list
42
SASREF HOUSING PROJECT PHASE2
Ground area: 7.68 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 43
SASREF HOUSING PROJECT PHASE2
Results
g1 0.66 S19
2.39 W/m²/100 lx
Luminaire list
44
SASREF HOUSING PROJECT PHASE2
Ground area: 3.06 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 45
SASREF HOUSING PROJECT PHASE2
Results
g1 0.72 S21
3.22 W/m²/100 lx
Luminaire list
46
SASREF HOUSING PROJECT PHASE2
Ground area: 3.11 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 47
SASREF HOUSING PROJECT PHASE2
Results
g1 0.71 S27
3.20 W/m²/100 lx
Luminaire list
48
SASREF HOUSING PROJECT PHASE2
Ground area: 2.56 m² | Reflection factors: Ceiling: 70.0 %, Walls: 50.0 %, Floor: 20.0 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 2.700 m 49
SASREF HOUSING PROJECT PHASE2
Results
g1 0.75 S25
3.61 W/m²/100 lx
Luminaire list
50
SASREF HOUSING PROJECT PHASE2
Glossary
Background area The background area borders the direct ambient area according to DIN EN 12464-1 and
reaches up to the borders of the room. In larger rooms, the background area is at least 3
m wide. It is located horizontally at floor level.
Allocation of the light colors to the color temperature ranges acc. to EN 12464-1:
Clearance height The designation for the distance between upper edge of the floor and bottom edge of
the ceiling (in the completely furnished status of room).
The general color rendering index Ra (or CRI) is a dimensionless figure that describes the
quality of a white light source in regards to its similarity with the remission spectra of
defined 8 test colors (see DIN 6169 or CIE 1974) to a reference light source.
Daylight factor Ratio of the illuminance achieved solely by daylight incidence at a point in the inside to
the horizontal illuminance in the outer area under an unobstructed sky.
51
SASREF HOUSING PROJECT PHASE2
Glossary
Daylight quotient effective area A calculation surface within which the daylight quotient is calculated.
Unit: %
Illuminance Describes the ratio of the luminous flux that strikes a certain surface to the size of this
surface (lm/m² = lx). The illuminance is not tied to an object surface. It can be determined
anywhere in space (inside or outside). The illuminance is not a product feature because it
is a recipient value. Luxometers are used for measuring.
Unit: Lux
Abbreviation: lx
Formula symbol: E
Illuminance, adaptive For the determining of the middle adaptive illuminance on a surface, this is rastered
"adaptively". In the area of large illuminance differences within the surface, the raster is
subdivided finer; within lesser differences, a rougher classification is made.
Illuminance, horizontal Illuminance that is calculated or measured on a horizontal (level) surface (this can be for
example a table top or the floor). The horizontal illuminance is usually identified by the
formula letter Eh.
Illuminance, perpendicular Illuminance that is calculated or measured plumb-vertical to a surface. This needs to be
taken into account for tilted surfaces. If the surface is horizontal or vertical, then there is
no difference between the perpendicular and the horizontal or vertical illuminance.
52
SASREF HOUSING PROJECT PHASE2
Glossary
Illuminance, vertical Illuminance that is calculated or measured on a vertical surface (this can be for example
the front of some shelves). The vertical illuminance is usually identified by the formula
letter Ev.
Luminance Dimension for the "brightness impression" that the human eye has of a surface. The
surface itself can emit light thereby or light striking it can be reflected (emitter value). It is
the only photometric value that the human eye can perceive.
Luminous efficacy Ratio of the emitted luminous flux Φ [lm] to the absorbed electrical power P [W] Unit:
lm/W.
This ratio can be formed for the lamp or LED module (lamp or module light output), the
lamp or module with control gear (system light output) and the complete luminaire
(luminaire light output).
53
SASREF HOUSING PROJECT PHASE2
Glossary
Luminous flux Dimension for the total light output that is emitted from one light source in all directions.
It is thus an "emitter value" that specifies the entire emitting output. The luminous flux of
a light source can only be determined in a laboratory. A difference is made between the
lamp or LED module luminous flux and the luminaire luminous flux.
Unit: Lumen
Abbreviation: lm
Formula symbol: Φ
Luminous intensity Describes the intensity of the light in a certain direction (emitter value). The luminous
intensity is a matter of the luminous flux Φ that is emitted in a certain spherical angle Ω.
The radiation characteristics of a light source are presented graphically in a light
distribution curve (LDC). The luminous intensity is an SI base unit.
Unit: Candela
Abbreviation: cd
Formula symbol: I
P (Engl. power)
Electric power consumption
Unit: watt
Abbreviation: W
Reflection factor The reflection factor of a surface describes how much of the striking light is reflected
back. The reflection factor is defined by the color of the surface.
54
SASREF HOUSING PROJECT PHASE2
Glossary
Surrounding area The ambient area directly borders the area of the visual task and should be planned with
a width of at least 0.5 m according to DIN EN 12464-1. It is at the same height as the
area of the visual task.
UGR observer Calculation point in the room, for the DIALux the UGR value is determined. The location
and height of the calculation point should correspond to the typical observer position
(position and eye level of the user).
Visual task area The area that is needed for carrying out the visual task in accordance with DIN EN 12464-
1. The height corresponds with the height at which the visual task is executed.
Wall zone Circumferential area between working plane and walls that is not taken into account for
the calculation.
Workplane Virtual measuring or calculation surface at the height of the visual task that generally
follows the room geometry. The working plane may also feature a wall zone.
55