You are on page 1of 2

BM-KTSPGC-01

INSPECTION REPORT BH/SĐ: 01/00


Ngày hiệu lực: .15/10/2018

Process OQC Maker Check Approved

KIMSEN code KG-AH13 Rev. Drawing A

Cilent code 232-02541 Quantity 2880

Shift Shift day Inspection date 08/07/2021


N.V.LONG N.T.BÁU N.A.DŨNG
Hình ảnh minh họa:

Product inspection content


Sample test
I Inspection standard Method Standard Frequency Evaluate
OK NG

No disabilities,
1 Apperance Visual check 15pcs/2 trolley 15 0 OK
No deformation,

Standard Sample test


II Inspection standard Method Frequency Evaluate
Spec Min Max
Tol. (mm) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
(mm) (mm) (mm)

1 DIM 1 Scan 2D 60.0 ± 1.0 59.0 61.0 15pcs/2 trolley 60.2 59.2 59.3 59.4 59.7 59.4 60.0 59.2 59.4 59.7 59.7 59.3 59.4 60.2 59.7 OK

2 DIM 2 Caliper 57.14 ± 0.61 56.53 57.75 15pcs/2 trolley 57.09 57.15 57.16 57.14 57.12 57.13 57.10 57.16 57.14 57.15 57.15 57.18 57.11 57.12 57.10 OK

3 DIM 3 Scan 2D 3.73 ± 0.18 3.55 3.91 15pcs/2 trolley 3.69 3.76 3.77 3.68 3.79 3.75 3.74 3.68 3.75 3.69 3.69 3.76 3.75 3.71 3.69 OK

4 DIM 4 Caliper 27.03 ± 0.66 26.37 27.69 15pcs/2 trolley 26.86 26.73 26.77 26.94 26.87 26.72 26.77 26.78 26.71 26.76 26.77 26.96 26.83 26.65 26.81 OK

5 DIM 5 Caliper 5.54 ± 0.25 5.29 5.79 15pcs/2 trolley 5.45 5.46 5.45 5.46 5.45 5.46 5.43 5.45 5.46 5.46 5.45 5.45 5.44 5.43 5.44 OK

6 DIM 6 Caliper 5.47 ± 0.51 4.96 5.98 15pcs/2 trolley 5.41 5.39 5.40 5.39 5.40 5.39 5.38 5.41 5.40 5.40 5.39 5.40 5.39 5.39 5.40 OK

7 DIM 7 Caliper 34.80 ± 0.66 34.14 35.46 15pcs/2 trolley 34.67 34.60 34.60 34.77 34.66 34.59 34.56 34.62 34.54 34.53 34.57 34.70 34.60 34.50 34.58 OK

8 DIM 8 Caliper 1.65 ± 0.15 1.50 1.80 15pcs/2 trolley 1.58 1.56 1.57 1.55 1.55 1.57 1.57 1.57 1.56 1.57 1.55 1.56 1.56 1.55 1.57 OK

9 DIM 9 Caliper 34.93 ± 0.36 34.57 35.29 15pcs/2 trolley 34.9 34.91 34.94 34.89 34.89 34.9 34.85 34.88 34.85 34.87 34.88 34.96 34.91 34.82 34.87 OK

10 DIM 10 Caliper 1.91 ± 0.15 1.76 2.06 15pcs/2 trolley 1.83 1.84 1.83 1.84 1.82 1.82 1.83 1.83 1.83 1.83 1.82 1.83 1.81 1.82 1.83 OK

11 DIM 11 Caliper 2.03 ± 0.25 1.78 2.28 15pcs/2 trolley 1.93 1.95 1.95 1.92 1.93 1.96 1.94 1.96 1.96 1.96 1.94 1.96 1.96 1.94 1.94 OK

12 DIM 12 Caliper 1.52 # 0.15 1.37 1.67 15pcs/2 trolley 1.50 1.52 1.49 1.50 1.50 1.48 1.48 1.50 1.50 1.49 1.49 1.50 1.50 1.50 1.49 OK
Standard Sample test
II Inspection standard Method Frequency Evaluate
Spec Min Max
Tol. (mm) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
(mm) (mm) (mm)

+0.38
13 DIM 13 Caliper 34.93 34.68 35.31 15pcs/2 trolley 34.91 34.94 34.96 34.92 34.92 34.94 34.90 34.97 34.95 34.96 34.95 34.95 34.94 34.94 34.95 OK
-0.25

14 DIM 14 Scan 2D 12.93 ± 0.23 12.70 13.16 15pcs/2 trolley 12.97 12.97 12.98 12.97 12.98 12.98 12.98 13.00 12.99 12.98 12.97 12.96 12.98 12.94 12.96 OK

15 DIM 15 Caliper 14.13 ± 0.23 13.90 14.36 15pcs/2 trolley 14.05 14.07 14.08 14.08 14.07 14.18 14.08 14.08 14.08 14.09 14.10 14.07 14.05 14.06 14.10 OK

16 DIM 16 Caliper 2.38 ± 0.15 2.23 2.53 15pcs/2 trolley 2.42 2.42 2.41 2.39 2.39 2.41 2.40 2.42 2.40 2.41 2.40 2.41 2.42 2.40 2.40 OK

Hardness Pliers >=13 HW 15pcs/2 trolley 14 15 15 15 16 15 14 15 15 14 14 14 15 15 14 OK

coating thickness
Coating thickness 10÷18μm 15pcs/2 trolley 16.2 16.3 14.7 16 14.8 13.4 15.7 14.1 13.6 15.8 16.3 14.1 13.8 15.6 15.8 OK
gauge

(OK - V: Passed - (NG - X: Rejected) Result: OK