You are on page 1of 9

BORDER: 594X841 A1 - VERSION: 1.

0
P-20XA P-20XB P-20XC
RAS PUMP RAS PUMP RAS PUMP
NOTE 1 NOTE 1

PIT PG FIT
PIT PG 3924 3/8"
3915 3918
3909 3912 CAMLOCK I.A.
CAMLOCK 1/2" 1/2" & PLUG _AE39
& PLUG 1/2" 1/2" RO
_BJ39 _BF39 16"-_AI39-CS1.1 FV
M 3921

_CN39
_BS39

_BP39
_BN39 _BI39 12"

3/4"

3/4"
_BW39

1"
1" FE 3925

_CP39

_BR39
16"

3/4"

3/4"
1"

1"
12" 12" 16" 3924 16" 16"
12"xXX 16"x12" 16"xXX 16"xXX
= 1" AT PLOT SCALE

16" 16" 16"xXX


16"-_AB39-CS1.1 M TO AERATION TANK B-4009A 43
FROM CLARIFIER A 46 EJ-_AB39 _BA39 _AW39 _AK39 _CT39 FO _CS39
_AV39 STR-_CY39 EJ-_AA39

_BD39
_BE39
XX

_BC39

3/4"

3/4"
3/4"
_CI39

_BZ39
3/4"

3/4"
12"-_AJ39-CS1.1

SAMPLE
P-20XA
14"

TUBING
_CQ39
EV
3903
S 1" 1" 1"
1"-_AF39-CS1.1 FG

1" _CA39 3906 _AR39 _BB39


RAS PUMP SKID A

PIT PG
PIT PG
3916 3919
3910 3913 CAMLOCK
CAMLOCK 1/2" 1/2" & PLUG
& PLUG 1/2" 1/2" RO
_BK39 _CD39
M

_CM39
3922

_CE39
_BX39
_BL39 _BM39 12"

3/4"

3/4"
_CO39

1"
1"

_BU39

_BY39
16"

3/4"

3/4"
1"
1"
12"xXX 12" 12" 16"x12"
16" 16" 16"xXX
16"-_AD39-CS1.1
FROM CLARIFIER B 47 EJ-_AD39 _AZ39 _AS39
_CK39 STR-_CX39 EJ-_AC39

_CC39
_CJ39

3/4"
_CB39
3/4"

3/4"
12"-_AH39-CS1.1

SAMPLE
P-20XB

TUBING
EV
3904
S 1" 1" 1"
1"-_AG39-CS1.1 FG

1" _AJ39 3907 _AQ39 _AO39 RAS PUMP SKID B

PIT PG

J:\_SEI-BusProp\IS-11-Barranca\0-PID\Data\IS-XX-1003-39.dwg - Layout1 - 10/25/2019 12:42 PM - Klein, Jeffrey (GP SLN WS OC EN ME)


PIT PG
3917 3920
3911 3914 CAMLOCK
CAMLOCK 1/2" 1/2" & PLUG
& PLUG 1/2" 1/2" RO
_BO39 _AN39
M 3923

_AM39

_CR39
_BV39
_BG39 _BH39 12"

3/4"

3/4"

1"
1"
_BQ39
_CL39

_BT39

16"
3/4"

3/4"

1"
1"

12"xXX 12" 12" 16"x12"


16" 16" 16"xXX
16"-_AE39-CS1.1
FROM CLARIFIER C 48 EJ-_AF39 _AY39 _AT39
_AU39 STR-_CW39 EJ-_AE39

_CF39
_CH39

3/4"
3/4"

_AI39
3/4"

12"-_AC39-CS1.1

SAMPLE
P-20XC

PG
TUBING

3902
1/2"
PCV
_AL39 EV
_AX39

3901
3/4"

1" 3905
1" STR-_CV39 S 1" 1" 1"
1"-_AA39-CS1.1 1"-_AA39-CS1.1 FG
UTILITY WATER 01
_AF39 1" 1" _AH39 3908 _AP39 _CG39
1/2

RAS PUMP SKID C


"
_A
G3
9

COMPANY CONFIDENTIAL TITLE


NOTES: ANY INFORMATION GIVEN IN THIS DOCUMENT IS WASTEWATER TREATMENT SYSTEM
1) PART OF TEMPORARY TREATMENT SYSTEM. THE PROPERTY OF SIEMENS ENERGY, INC.
TRANSMITTAL, REPRODUCTION, DISSEMINATION
PIPING AND INSTRUMENTATION DIAGRAM
AND/OR EDITING OF THIS DOCUMENT AS WELL AS
UTILIZATION OF ITS CONTENTS AND
CLIENT
COMMUNICATION THERE OF TO OTHERS WITHOUT
EXPRESS AUTHORIZATION ARE PROHIBITED.
BARRANCA BERMESA
OFFENDERS WILL BE HELD LIABLE FOR PAYMENT
OF DAMAGES. ALL RIGHTS CREATED BY PATENT SCALE:
GRANT OR REGISTRATION OF A UTILITY MODEL OR
DESIGN PATENT ARE RESERVED.
WATER NONE

SOLUTIONS SHEET:
39 OF 64
A REVISED PER COMMENTS 25/OCT/19 JDK COPYRIGHT (c) SIEMENS ENERGY, INC. DRAWING
NUMBER
REV DESCRIPTION DATE DRWN CHKD APVD
2016
ALL RIGHTS RESERVED
IS-11-1003
BORDER: 594X841 A1 - VERSION: 1.0

T-205A XXXXA
CLARIFIER CLAIRIFIER RAKE/MECHANISM
NOTE 1 NOTE 1
= 1" AT PLOT SCALE

TORQUE TORQUE
XSHH XSH
4602
M 4602

SCUM
BEACH

20"-_AC46-CS1.1
OVERFLOW TO DISCHARGE 64

4"

4"-_AB46-CS1.1 SCUM TO CLARIFIER


SCUM TANK 50

XXXXA

J:\_SEI-BusProp\IS-11-Barranca\0-PID\Data\IS-XX-1003-46.dwg - Layout1 - 10/25/2019 12:42 PM - Klein, Jeffrey (GP SLN WS OC EN ME)


T-205A

18"-_AD46-CS1.1 18"-_AE46-CS1.1
18"x16" 16"-_AA46-CS1.1
FROM CLARIFIER FEED PUMP 45 TO RAS PUMP A 39

_AB46
3"
_AD46
1"

VACUUM
BPV TRUCK
CONNECTION
_AC46

4601
1"

6"-_AG46-CS1.1
TO WASTE PUMP A 49
1"
1"-_AF46-XXXX
POLYMER FROM DOSING 59
_AE46 1"

COMPANY CONFIDENTIAL TITLE


NOTES: ANY INFORMATION GIVEN IN THIS DOCUMENT IS WASTEWATER TREATMENT SYSTEM
1) PART OF TEMPORARY TREATMENT SYSTEM. THE PROPERTY OF SIEMENS ENERGY, INC.
TRANSMITTAL, REPRODUCTION, DISSEMINATION
PIPING AND INSTRUMENTATION DIAGRAM
AND/OR EDITING OF THIS DOCUMENT AS WELL AS
UTILIZATION OF ITS CONTENTS AND
CLIENT
COMMUNICATION THERE OF TO OTHERS WITHOUT
EXPRESS AUTHORIZATION ARE PROHIBITED.
BARRANCA BERMESA
OFFENDERS WILL BE HELD LIABLE FOR PAYMENT
OF DAMAGES. ALL RIGHTS CREATED BY PATENT SCALE:
GRANT OR REGISTRATION OF A UTILITY MODEL OR
DESIGN PATENT ARE RESERVED.
WATER NONE

SOLUTIONS SHEET:
46 OF 64
A REVISED PER COMMENTS 25/OCT/19 JDK COPYRIGHT (c) SIEMENS ENERGY, INC. DRAWING
NUMBER
REV DESCRIPTION DATE DRWN CHKD APVD
2016
ALL RIGHTS RESERVED
IS-11-1003
BORDER: 594X841 A1 - VERSION: 1.0

T-205B XXXXB
CLARIFIER CLARIFIER RAKE/MECHANISM
NOTE 1 NOTE 1
= 1" AT PLOT SCALE

TORQUE TORQUE
XSHH XSH
4702
M 4702

SCUM
BEACH

20"-_AF47-CS1.1
OVERFLOW TO DISCHARGE 64

4"

4"-_AE47-CS1.1 SCUM TO CLARIFIER


SCUM TANK 50

XXXXB

J:\_SEI-BusProp\IS-11-Barranca\0-PID\Data\IS-XX-1003-47.dwg - Layout1 - 10/25/2019 12:42 PM - Klein, Jeffrey (GP SLN WS OC EN ME)


T-205B

18"-_AC47-CS1.1 18"-_AD47-CS1.1
18"x16" 16"-_AA47-CS1.1
FROM CLARIFIER FEED PUMP 45 TO RAS PUMP B 39

_AB47
3"
_AC47
1"

VACUUM
BPV TRUCK
_AE47

4701 CONNECTION
1"

6"-_AB47-CS1.1
TO WASTE PUMP B 49
1"
1"-_AG47-XXXX
POLYMER FROM DOSING 59
_AD47 1"

COMPANY CONFIDENTIAL TITLE


NOTES: ANY INFORMATION GIVEN IN THIS DOCUMENT IS WASTEWATER TREATMENT SYSTEM
1) PART OF TEMPORARY TREATMENT SYSTEM. THE PROPERTY OF SIEMENS ENERGY, INC.
TRANSMITTAL, REPRODUCTION, DISSEMINATION
PIPING AND INSTRUMENTATION DIAGRAM
AND/OR EDITING OF THIS DOCUMENT AS WELL AS
UTILIZATION OF ITS CONTENTS AND
CLIENT
COMMUNICATION THERE OF TO OTHERS WITHOUT
EXPRESS AUTHORIZATION ARE PROHIBITED.
BARRANCA BERMESA
OFFENDERS WILL BE HELD LIABLE FOR PAYMENT
OF DAMAGES. ALL RIGHTS CREATED BY PATENT SCALE:
GRANT OR REGISTRATION OF A UTILITY MODEL OR
DESIGN PATENT ARE RESERVED.
WATER NONE

SOLUTIONS SHEET:
47 OF 64
A REVISED PER COMMENTS 25/OCT/19 JDK COPYRIGHT (c) SIEMENS ENERGY, INC. DRAWING
NUMBER
REV DESCRIPTION DATE DRWN CHKD APVD
2016
ALL RIGHTS RESERVED
IS-11-1003
BORDER: 594X841 A1 - VERSION: 1.0
P-202A P-202B P-202C
WASTE PUMP WASTE PUMP WASTE PUMP
NOTE 1 NOTE 1
XY AFR
4925 4925
PIT PG FIT S 3/8"
R
PIT PG 4924 I.A.
4915 4918 F
4909 4912 CAMLOCK XX _AE49
CAMLOCK 1/2" 1/2" & PLUG
& PLUG 1/2" 1/2" RO
XV RO
_BE49 _BD49
M 4921

_CO49
_BQ49

_BN49
_BL49 _BG49 4" 4926

3/4"

3/4"
_BW49

1"
1" FE 4925

_CK49

_BR49
6"

3/4"

3/4"
1"

1"
4" 4" 6" 4924
4"xXX 6"x4"
= 1" AT PLOT SCALE

6"-_AJ49-CS1.1 BIOLOGICAL SLUDGE


6" 6" 6"xXX
6"-_AB49-CS1.1 M THICKENER TANK 51
FROM CLARIFIER A 46 EJ-_AB49 _BA49 _AW49 _AK49
_AV49 STR-_CT49 EJ-_AA49 6"

_BC49
_CH49

3/4"
_BX49
3/4"

3/4"
4"-_AC49-CS1.1

SAMPLE
P-202A

TUBING
EV
4903
S 1" 1" 1"
1"-_AI49-CS1.1 FG

1" _BY49 4906 _AR49 _BB49


WASTE PUMP SKID A

PIT PG
PIT PG
4916 4919
4910 4913 CAMLOCK
CAMLOCK 1/2" 1/2" & PLUG
& PLUG 1/2" 1/2" RO
_BH49 _CB49
M

_CM49
4922

_CC49
_BP49
_BJ49 _BK49 4"

3/4"

3/4"

1"
1"

_BU49

_BV49
_CL49
6"

3/4"

3/4"
1"
1"
4"xXX 4" 4" 6"x4"
6" 6" 6"xXX
6"-_AE49-CS1.1
FROM CLARIFIER B 47 EJ-_AD49 _AZ49 _AS49
_CI49 STR-_CS49 EJ-_AC49

_CA49
_CG49

3/4"
_BZ49
3/4"

3/4"
4"-_AF49-CS1.1

SAMPLE
P-202B

TUBING
EV
4904
S 1" 1" 1"
1"-_AH49-CS1.1 FG

1" _AJ49 4907 _AQ49 _AO49 WASTE PUMP SKID B

J:\_SEI-BusProp\IS-11-Barranca\0-PID\Data\IS-XX-1003-49.DWG - Layout1 - 10/25/2019 12:42 PM - Klein, Jeffrey (GP SLN WS OC EN ME)


PIT PG
PIT PG
4917 4920
4911 4914 CAMLOCK
CAMLOCK 1/2" 1/2" & PLUG
& PLUG 1/2" 1/2" RO
_BF49 _AN49
M 4923

_AM49
_BO49

_CJ49
_BM49 _BI49 4"

3/4"

3/4"

1"
1"
_CN49

_BS49
_BT49

6"
3/4"

3/4"

1"
1"

4"xXX 4" 4" 6"x4"


6" 6" 6"xXX
6"-_AD49-CS1.1
FROM CLARIFIER C 48 EJ-_AF49 _AY49 _AT49
_AU49 STR-_CR49 EJ-_AE49

_CD49
_CF49

3/4"
3/4"

_AI49
3/4"

4"-_AA49-CS1.1

SAMPLE
P-202C

PG
TUBING

4902
1/2"
PCV
_AL49 EV
_AX49

4901
3/4"

1" 4905
1" STR-_CQ49 S 1" 1" 1"
1"-_AG49-CS1.1 1"-_AG49-CS1.1 FG
UTILITY WATER 01
_AF49 1" 1" _AH49 4908 _AP49 _CE49
1/2

WASTE PUMP SKID C


"
_A
G4
9

COMPANY CONFIDENTIAL TITLE


NOTES: ANY INFORMATION GIVEN IN THIS DOCUMENT IS WASTEWATER TREATMENT SYSTEM
1) PART OF TEMPORARY TREATMENT SYSTEM. THE PROPERTY OF SIEMENS ENERGY, INC.
TRANSMITTAL, REPRODUCTION, DISSEMINATION
PIPING AND INSTRUMENTATION DIAGRAM
AND/OR EDITING OF THIS DOCUMENT AS WELL AS
UTILIZATION OF ITS CONTENTS AND
CLIENT
COMMUNICATION THERE OF TO OTHERS WITHOUT
EXPRESS AUTHORIZATION ARE PROHIBITED.
BARRANCA BERMESA
OFFENDERS WILL BE HELD LIABLE FOR PAYMENT
OF DAMAGES. ALL RIGHTS CREATED BY PATENT SCALE:
GRANT OR REGISTRATION OF A UTILITY MODEL OR
DESIGN PATENT ARE RESERVED.
WATER NONE

SOLUTIONS SHEET:
49 OF 64
A REVISED PER COMMENTS 25/OCT/19 JDK COPYRIGHT (c) SIEMENS ENERGY, INC. DRAWING
NUMBER
REV DESCRIPTION DATE DRWN CHKD APVD
2016
ALL RIGHTS RESERVED
IS-11-1003
BORDER: 594X841 A1 - VERSION: 1.0
T-206 P-203A P-203B
CLARIFIER SCUM TANK CLARIFIER SCUM PUMP CLARIFIER SCUM PUMP
(STEEL TANK) NOTE 1 NOTE 1
NOTE 1

4"
4"-_AD50-CS1.1
SCUM FROM CLARIFIER A 46
= 1" AT PLOT SCALE

_BO50

4"
4"-_AC50-CS1.1
SCUM FROM CLARIFIER B 47
_BN50

4"
4"-_AB50-CS1.1
SCUM FROM CLARIFIER C 48
_BM50

RADAR RADAR
LIT LIT
5001 5002

PIT PG
PIT PG VFD 5013 5015
5009 5011 CAMLOCK
CAMLOCK & PLUG
1/2" 1/2"
& PLUG 1/2" 1/2"
_BD50 _AD50

_AS50
M

_AF50
_AZ50 _AE50

_BQ50
3/4"

3/4"
2"

_AG50
_AP50

1"
1"

_BS50

3/4"

3/4"
3"

1"
1"
2"xXX 2" 2" TO BIOLOGICAL SLUDGE
3" 3" 3"xXX
3"-_AI50-CS1.1 THICKENER TANK 51
EJ-_AB50 _AV50 _AU50
_AI50 STR-_BV50 EJ-_AA50

_AW50
_AH50
3/4"

3/4"
2"-_AF50-CS1.1
T-206 P-203A

TUBING
EV
5005
S 1" 1" 1"
1"-_AJ50-CS1.1 FG

1" _BI50 5007 _BJ50 _BK50

J:\_SEI-BusProp\IS-11-Barranca\0-PID\Data\IS-XX-1003-50.dwg - Layout1 - 10/25/2019 12:42 PM - Klein, Jeffrey (GP SLN WS OC EN ME)


PIT PG
PIT PG VFD 5014 5016
5010 5012 CAMLOCK
CAMLOCK & PLUG
1/2" 1/2"
& PLUG 1/2" 1/2"
_BC50 _AY50

_AO50
M

_AT50
PG _BA50 _BB50

_BR50
3/4"

3/4"
2"

_AQ50

_AR50

1"
1"

_BP50

3/4"

3/4"
5004 3"

1"
1/2" 2"xXX 2" 2"
3" 3" 3"xXX
PCV 3"-_AA50-CS1.1
_AM50 EJ-_AD50 _BE50 _BF50
_AN50

5003 _BL50 STR-_BW50 EJ-_AC50


3/4"

_BG50
_BH50
3/4"

3/4"
1"
1" STR-_BU50 2"-_AH50-CS1.1
1"-_AG50-CS1.1
UTILITY WATER 01 P-203B

TUBING
_AL50 1" 1/2 EV
"
5006
_A

S 1" 1" 1"


K

FG
50

1"-_AK50-CS1.1

1" _AJ50 5008 _AC50 _AX50

CLARIFIER SCUM PUMP SKID

COMPANY CONFIDENTIAL TITLE


NOTES: ANY INFORMATION GIVEN IN THIS DOCUMENT IS WASTEWATER TREATMENT SYSTEM
1) PART OF TEMPORARY TREATMENT SYSTEM. THE PROPERTY OF SIEMENS ENERGY, INC.
TRANSMITTAL, REPRODUCTION, DISSEMINATION
PIPING AND INSTRUMENTATION DIAGRAM
AND/OR EDITING OF THIS DOCUMENT AS WELL AS
UTILIZATION OF ITS CONTENTS AND
CLIENT
COMMUNICATION THERE OF TO OTHERS WITHOUT
EXPRESS AUTHORIZATION ARE PROHIBITED.
BARRANCA BERMESA
OFFENDERS WILL BE HELD LIABLE FOR PAYMENT
OF DAMAGES. ALL RIGHTS CREATED BY PATENT SCALE:
GRANT OR REGISTRATION OF A UTILITY MODEL OR
DESIGN PATENT ARE RESERVED.
WATER NONE

SOLUTIONS SHEET:
50 OF 64
A REVISED PER COMMENTS 25/OCT/19 JDK COPYRIGHT (c) SIEMENS ENERGY, INC. DRAWING
NUMBER
REV DESCRIPTION DATE DRWN CHKD APVD
2016
ALL RIGHTS RESERVED
IS-11-1003
BORDER: 594X841 A1 - VERSION: 1.0
T-207 XXXX T-209
BIOLOGICAL SLUDGE THICKENER TANK BIOLOGICAL SLUDGE THICKENER THICKENER SCUM TANK
(STEEL TANK - BY OTHERS) MECHANISM AND DRIVE NOTE 1
NOTE 1 NOTE 1
= 1" AT PLOT SCALE

2"-_AB51-CS1.1
FROM CLARIFIER SCUM PUMPS 50

4"-_AD51-CS1.1
FROM WASTE SLUDGE PUMPS 49

M
LIT
5101

XXXX SCUM
BEACH

8"
8"-_AE51-CS1.1 TO BIOLOGICAL SLUDGE
THICKENER OVERFLOW SUMP 52

XY AFR
5103 5103
S R 3/8"
I.A.
F _AF51
XX
XV XX
4" RADAR
5103
LIT
4"-_AC51-CS1.1 5102

VACUUM 3" 4" XY AFR


TRUCK 5104 5104
CONNECTION _AG51 S R 3/8"

J:\_SEI-BusProp\IS-11-Barranca\0-PID\Data\IS-XX-1003-51.dwg - Layout1 - 10/25/2019 12:43 PM - Klein, Jeffrey (GP SLN WS OC EN ME)


I.A.
F _AD51
XX
XX

XV
3"
5104

3"-_AA51-CS1.1

3"

T-207 T-209

AFR XY
5105 5105
3/8" R
S CAMLOCK
I.A. & PLUG
_AE51 F
XX
XX

_AN51
XV

1"
2"
5105

2"-_AG51-CS1.1
3"x2" 3"-_AF51-CS1.1
TO CENTRIFUGE FEED PUMP 53

2"

COMPANY CONFIDENTIAL TITLE


NOTES: ANY INFORMATION GIVEN IN THIS DOCUMENT IS WASTEWATER TREATMENT SYSTEM
1) PART OF TEMPORARY TREATMENT SYSTEM. THE PROPERTY OF SIEMENS ENERGY, INC.
TRANSMITTAL, REPRODUCTION, DISSEMINATION
PIPING AND INSTRUMENTATION DIAGRAM
AND/OR EDITING OF THIS DOCUMENT AS WELL AS
UTILIZATION OF ITS CONTENTS AND
CLIENT
COMMUNICATION THERE OF TO OTHERS WITHOUT
EXPRESS AUTHORIZATION ARE PROHIBITED.
BARRANCA BERMESA
OFFENDERS WILL BE HELD LIABLE FOR PAYMENT
OF DAMAGES. ALL RIGHTS CREATED BY PATENT SCALE:
GRANT OR REGISTRATION OF A UTILITY MODEL OR
DESIGN PATENT ARE RESERVED.
WATER NONE

SOLUTIONS SHEET:
51 OF 64
A REVISED PER COMMENTS 25/OCT/19 JDK COPYRIGHT (c) SIEMENS ENERGY, INC. DRAWING
NUMBER
REV DESCRIPTION DATE DRWN CHKD APVD
2016
ALL RIGHTS RESERVED
IS-11-1003
BORDER: 594X841 A1 - VERSION: 1.0
T-210 P-208A P-208B
BIOLOGICAL SLUDGE THICKENER OVERFLOW SUMP BIOLOGICAL SLUDGE THICKENER OVERFLOW PUMP BIOLOGICAL SLUDGE THICKENER OVERFLOW PUMP
(STEEL TANK) NOTE 1 NOTE 1
NOTE 1
= 1" AT PLOT SCALE

8"
8"-_AB52-CS1.1
THICKENER OVERFLOW 51
_BM52

BIOLOGICAL SLUDGE CENTRATE 2"


2"-_AA52-CS1.1
FROM CENTRIFUGE A 54
_BO52

BIOLOGICAL SLUDGE CENTRATE 2"


2"-_AI52-CS1.1
FROM CENTRIFUGE B 55
_BN52

RADAR RADAR
LIT LIT
5201 5202

PIT PG
PIT PG VFD 5216 5215
5209 5211 CAMLOCK
CAMLOCK & PLUG
1/2" 1/2"
& PLUG 1/2" 1/2"
_AI52 _AD52

_AO52
M

_AJ52
_AF52 _AG52

_BQ52
3/4"

3/4"
_AM52
4"

_AK52

1"
1"

_BP52

3/4"

3/4"
6"

1"
4"xXX 4" 4" 4"
6" 6" 6"xXX TO AERATION BASIN BA-4009A 43
EJ-_AB52 _AZ52 _AY52
_AQ52 STR-_BV52 EJ-_AA52

_AP52

_BA52
3/4"

3/4"
T-210 6"-_AG52-CS1.1 P-208A
4"-_AF52-CS1.1

TUBING
EV
5205
S 1" 1" 1"
1"-_AK52-CS1.1 FG

1" _BI52 5207 _BJ52 _BK52

J:\_SEI-BusProp\IS-11-Barranca\0-PID\Data\IS-XX-1003-52.dwg - Layout1 - 10/25/2019 12:43 PM - Klein, Jeffrey (GP SLN WS OC EN ME)


PIT PG
PIT PG VFD 5214 5213
5210 5212 CAMLOCK
CAMLOCK & PLUG
1/2" 1/2"
& PLUG 1/2" 1/2"
_AH52 _BC52

_AW52
_AN52
PG _AE52 _BD52 M

_BR52
3/4"

3/4"
4"

_AX52
_AL52

1"
1"

_BS52

3/4"

3/4"
5204 6"
1"

1/2" 4"xXX 4" 4" 4"


6" 6" 6"xXX
PCV TO BA-4009B
_AU52 EJ-_AD52 _BE52 _BF52
_AV52

5203 _BL52 STR-_BW52 EJ-_AC52


3/4"

_BG52
_BH52
3/4"

3/4"
1"
1" STR-_BU52 4"-_AH52-CS1.1
1"-_AC52-CS1.1
UTILITY WATER 01 6"-_AL52-CS1.1 P-208B

TUBING
_AT52 1" 1/2 EV
"
5206
_A

S 1" 1" 1"


S

FG
52

1"-_AJ52-CS1.1

1" _AR52 5208 _AC52 _BB52

BIOLOGICAL SLUDGE THICKENER OVERFLOW PUMP SKID

COMPANY CONFIDENTIAL TITLE


NOTES: ANY INFORMATION GIVEN IN THIS DOCUMENT IS WASTEWATER TREATMENT SYSTEM
1) PART OF TEMPORARY TREATMENT SYSTEM. THE PROPERTY OF SIEMENS ENERGY, INC.
TRANSMITTAL, REPRODUCTION, DISSEMINATION
PIPING AND INSTRUMENTATION DIAGRAM
AND/OR EDITING OF THIS DOCUMENT AS WELL AS
UTILIZATION OF ITS CONTENTS AND
CLIENT
COMMUNICATION THERE OF TO OTHERS WITHOUT
EXPRESS AUTHORIZATION ARE PROHIBITED.
BARRANCA BERMESA
OFFENDERS WILL BE HELD LIABLE FOR PAYMENT
OF DAMAGES. ALL RIGHTS CREATED BY PATENT SCALE:
GRANT OR REGISTRATION OF A UTILITY MODEL OR
DESIGN PATENT ARE RESERVED.
WATER NONE

SOLUTIONS SHEET:
52 OF 64
A REVISED PER COMMENTS 25/OCT/19 JDK COPYRIGHT (c) SIEMENS ENERGY, INC. DRAWING
NUMBER
REV DESCRIPTION DATE DRWN CHKD APVD
2016
ALL RIGHTS RESERVED
IS-11-1003
BORDER: 594X841 A1 - VERSION: 1.0
P-206A P-206B
BIOLOGICAL SLUDGE CENTRIFUGE FEED PUMP BIOLOGICAL SLUDGE CENTRIFUGE FEED PUMP
NOTE 1 NOTE 1

PIT PG
PIT PG VFD 5311 5313 CAMLOCK
= 1" AT PLOT SCALE

5307 5309 CAMLOCK & PLUG


& PLUG 1/2" 1/2"
1/2" 1/2"

_BP53
_BD53 _BA53
M

1"
1"

_BG53
_BN53

_BE53
_BB53 _BC53 1 1/2"

3/4"

3/4"
1"

1"
_BH53
_BF53
2"

3/4"

3/4"
1 1/2"xXX 1 1/2" 1 1/2" 1 1/2"
2" 2" 1 1/2"-_AC53-CS1.1
BIOLOGICAL SLUDGE 2"-_AA53-CS1.1 2"xXX TO CENTRIFUGE A/B 54
FROM THICKENER 51 EJ-_AB53 _AX53 _AU53
_AT53 STR-_BV53 EJ-_AA53

_AZ53
_BM53

3/4"
3/4"

_BI53
3/4"
SAMPLE
P-206A

TUBING
EV
5303
S 1" 1" 1"
1"-_AD53-CS1.1 FG

1" _BJ53 5305 _AQ53 _AY53

PIT PG
PIT PG VFD 5312 5314 CAMLOCK
5308 5310 CAMLOCK & PLUG
& PLUG 1/2" 1/2"
1/2" 1/2"

_BO53
_AN53 _AL53
M

1"
1"

_BQ53

_AH53
_AK53
_AM53 _AO53 1 1/2"

3/4"

3/4"
1"
1"
_AJ53

2" _AI53
3/4"

3/4"

1 1/2"xXX 1 1/2" 1 1/2" 1 1/2"


2" 2" 1 1/2"-_AB53-CS1.1
2"-_AE53-CS1.1 2"xXX TO SLUDGE DISPOSAL
EJ-_AD53 _AW53 _AR53 (BY OTHERS)
_AS53 STR-_BU53 EJ-_AC53

_BK53
3/4"
_AF53
3/4"

J:\_SEI-BusProp\IS-11-Barranca\0-PID\Data\IS-XX-1003-53.dwg - Layout1 - 10/25/2019 12:43 PM - Klein, Jeffrey (GP SLN WS OC EN ME)


P-206B

PG

TUBING
5302
1/2"
PCV
_AG53 EV
_AV53

5301
3/4"

1" 5304
1" STR-_BT53 S 1" 1" 1"
1"-_AF53-CS1.1 FG
UTILITY WATER 01
_AC53 1" 1" _AE53 5306 _AP53 _BL53
1/2
"
_A
D5
3

BIOLOGICAL SLUDGE CENTRIFUGE FEED PUMP SKID

COMPANY CONFIDENTIAL TITLE


NOTES: ANY INFORMATION GIVEN IN THIS DOCUMENT IS WASTEWATER TREATMENT SYSTEM
1) PART OF TEMPORARY TREATMENT SYSTEM. THE PROPERTY OF SIEMENS ENERGY, INC.
TRANSMITTAL, REPRODUCTION, DISSEMINATION
PIPING AND INSTRUMENTATION DIAGRAM
AND/OR EDITING OF THIS DOCUMENT AS WELL AS
UTILIZATION OF ITS CONTENTS AND
CLIENT
COMMUNICATION THERE OF TO OTHERS WITHOUT
EXPRESS AUTHORIZATION ARE PROHIBITED.
BARRANCA BERMESA
OFFENDERS WILL BE HELD LIABLE FOR PAYMENT
OF DAMAGES. ALL RIGHTS CREATED BY PATENT SCALE:
GRANT OR REGISTRATION OF A UTILITY MODEL OR
DESIGN PATENT ARE RESERVED.
WATER NONE

SOLUTIONS SHEET:
53 OF 64
A REVISED PER COMMENTS 25/OCT/19 JDK COPYRIGHT (c) SIEMENS ENERGY, INC. DRAWING
NUMBER
REV DESCRIPTION DATE DRWN CHKD APVD
2016
ALL RIGHTS RESERVED
IS-11-1003
BORDER: 594X841 A1 - VERSION: 1.0

FIELD PIPING OTHERS

FROM CLARIFIER A 46

CLOSED
LC
NOTE 1 XX
FROM CLARIFIER B 47 C C C C C C C C C C C C C C EXISTING PUMPS IN BA-4009B
= 1" AT PLOT SCALE

LO
XX
FROM CLARIFIER C 48 C C C C C C C C C C C C C C WATER TO EFFLUENT SUMP

_AA64
3/4"
SAMPLE

FROM API SKIMMED OIL SLOP OIL TO


TRANSFER PUMPS 09 C C C C C C C C C C C C C C STORAGE TANK

RESOX DNF SLUDGE 35

API SLUDGE 07

DNF SLUDGE 18 C C C C C C C C C C C C C C TO OILY SLUDGE TANK

J:\_SEI-BusProp\IS-11-Barranca\0-PID\Data\IS-XX-1003-64.dwg - Layout1 - 10/30/2019 2:55 PM - Klein, Jeffrey (GP SLN WS OC EN ME)


COMPANY CONFIDENTIAL TITLE
NOTES: ANY INFORMATION GIVEN IN THIS DOCUMENT IS WASTEWATER TREATMENT SYSTEM
1) PART OF TEMPORARY TREATMENT SYSTEM. THE PROPERTY OF SIEMENS ENERGY, INC.
TRANSMITTAL, REPRODUCTION, DISSEMINATION
PIPING AND INSTRUMENTATION DIAGRAM
AND/OR EDITING OF THIS DOCUMENT AS WELL AS
UTILIZATION OF ITS CONTENTS AND
CLIENT
COMMUNICATION THERE OF TO OTHERS WITHOUT
EXPRESS AUTHORIZATION ARE PROHIBITED.
BARRANCA BERMESA
OFFENDERS WILL BE HELD LIABLE FOR PAYMENT
OF DAMAGES. ALL RIGHTS CREATED BY PATENT SCALE:
GRANT OR REGISTRATION OF A UTILITY MODEL OR
DESIGN PATENT ARE RESERVED.
WATER NONE

SOLUTIONS SHEET:
64 OF 64
COPYRIGHT (c) SIEMENS ENERGY, INC. DRAWING
NUMBER
REV DESCRIPTION DATE DRWN CHKD APVD
2016
ALL RIGHTS RESERVED
IS-11-1003