ALLO TECHNOLOGY SDN BHD

HSE INSPECTION REPORT

HEALTH, SAFETY & ENVIRONMENT (HSE) INSPECTION REPORT


NAME NUR NAJIHAH MOHAMED YUSOF
ISSUER
DESIGNATION HEALTH SAFETY & ENVIRONMENT OFFICER

DATE OF INSPECTION 07/01/2022 LOCATION ALLO OFFICE COMPLEX, CYBERJAYA

DATE OF ISSUANCE 12/01/2022 REF. NUMBER ALLO/HSE/SIR/007

MEMBER(S) OF NAME DESIGNATION


INSPECTION MOHAMAD AMMAR FITRI AFFENDI HSE EXECUTIVE

NURUL AIN MUSTAPA HEAD HUMAN RESOURCE


C.C TO:
MAHZAN MISKAM COO

NOTE: For internal circulation only.

Page 1 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

RECTIFICATION/IMPROVEMENT ACTION
Risk
TAKEN (Attach photos, description &
No Category Comments & Action Rating
date)
H M L
1. COVID-19 SOP Low
Compliance LOCATION: PRAYER ROOM

OBSERVATION:

Sharing prayer mat. Refer to MKN SOP and Allo


internal MEMO (ALLO/HSE/MEMO/14), all staff
shall use personal prayer mat. This condition
may expose staffs in cross infection if there is
Covid19 positive case.

RECOMMENDATION FOR IMPROVEMENT:

a) To remove all shared prayer mat


b) To ensure everyone bring thier own
prayer mat.

Page 2 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

LOCATION: FEMALE TOILET (MAIN OFFICE)

2. Low
OBSERVATION:

Insufficient handwash liquid.

RECOMMENDATION FOR IMPROVEMENT:

a) The handwash liquid shall be refilled.


b) The provisions of personal hygiene
provisions shall be periodically checked.

3. Low

Page 3 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

LOCATION: MAIN & ANNEX OFFICE

OBSERVATION:

Office hand sanitizer is empty and there are no


monitoring on the applicability.

RECOMMENDATION FOR IMPROVEMENT:

a) Strategic locations and numbers of hand


sanitizer placement shall be defined.
b) Periodical check and monitoring shall be
done.

4. Medium

Page 4 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

LOCATION: FEMALE TOILET & MAIN


OFFICE PANTRY

OBSERVATION:

Ventilation system in the office, toilet and other


building facilities are not functioning. Some
areas in the office complex were not being
installed with air ventilation system.

Page 5 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

Refer to guidance note on Ventilation and Indoor


Air Quality (IAQ) for non-residential setting
during Covid-19 pandemic: - Ventilation Air-
Conditioning (MVAC) system shall be
maintained and functioning as per design.

RECOMMENDATION FOR IMPROVEMENT:

a) The ventilation system shall be inspected


and the malfunctioning existing system
shall be corrected.
b) It is highly recommended to use portable
air ventilation/purifiers as additional and
backup measures.
c) Where permanent air ventilation system
could not be installed, portable air
ventilation system shall be used instead.

5. Electricity Medium

Page 6 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

LOCATION: LAB ROOM

OBSERVATION:

Poor cable management and housekeeping.


This unsafe condition may expose personnel to
the risk of slip, trip and fall.

RECOMMENDATION FOR IMPROVEMENT:

a) Housekeeping activity shall be carried


out and practiced on daily basis.
b) It is recommended to re-arrange
workstation and related equipment to
ensure the workspace safety.
c) Should the cables be still needed to be
laid on the floor, cable ramp is
recommended to be used.

Page 7 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

LOCATION: PANTRY

6. Medium
OBSERVATION:

Use of a three-way socket which is always


switched on. This condition may cause the
three-way socket to overheat and possibly
cause a fire.

RECOMMENDATION FOR IMPROVEMENT:

a) Recommended not to use the three-way


socket plug.
b) Re-wiring and install new socket by a
certified electrician.

Page 8 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

7. LOCATION: CVR SERVER ROOM 1

OBSERVATION:

Exposed electrical distribution panel/box (DB).


This unsafe condition may lead to electrocution
incident, misuse/tampering of facility, sabotage
and possibility of damaging the electrical
components by water and dust intrusion. Fire
may happen as subsequent event and
potentially spread to adjacent structure/building.

RECOMMENDATION FOR IMPROVEMENT:

a) The provided room/facility shall be


periodically checked and maintained by

Page 9 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

responsible party.
b) Information and contact details of
responsible party shall be displayed.
c) Inherent hazards shall be communicated
via signage display.
d) Access to the room shall be limited to
only authorized personnel and shall be
always locked.

8. Equipment
LOCATION: CVR ROOM
HIGH

OBSERVATION:

Use of fan without blade cover. This unsafe


condition may exposes personnel in the risk of
caught in between rotating equipment.

Page 10 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

Contionous use of domestic-type fan for long


term may overheat the motor and subsequently
trigger a firepoint. Fire incident may occur and
high potential to spread to adjacent structures.

RECOMMENDATION FOR IMPROVEMENT:

a) To remove the fan.


b) Use of existing air-conditioner for
equipment cooling purpose.
c) Ensure the door are always locked and
only authorized person can enter the
room (display information and prohibition
signage).

9. LOCATION: CVR ROOM HIGH

OBSERVATION:

Page 11 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

Use of a three-way socket which is always


switched on. Long term use of fully-loaded
socket may cause the socket to overheat and
possibly cause a fire incident.

Unsafe connections of electrical equipment


cables where no socket/plug top were being
used.

RECOMMENDATION FOR IMPROVEMENT:

a) Recommended not to use the three-way


socket plug.
b) Re-wiring and install new socket by a
certified electrician.
c) Remove unsafe electrical cable tapping
into the socket.

10. Storage and material LOCATION: OPERATION STORE ROOM Medium

Page 12 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

Poor storage area housekeeping. This condition


may expose related personnel in an ergonomics
factor, awkward working position, tripping and
falls. On other factors, this condition may lead to
vermins problem, equipment damage,
emergency access obstruction and decrease in
work efficiency.

RECOMMENDATION FOR IMPROVEMENT:

Page 13 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

a) Total housekeeping shall be carried out


and practised in periodical basis.
b) Assessment of material and equipment
shall be carried out to ensure only
needed material and equipment are
stored in the room.
c) The room layout shall be redesigned to
ensure work space is optimised and
access and egress are defined.
d) Material and equipment stored shall be
labelled.
e) Easy-to-fall equipment such as ladders
shall be secured preferably using
retaining-straps in an upright position to
prevent falling and damages.

11. LOCATION: STORAGE ROOM MEDIUM

Page 14 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

Poor storage room arrangement and layout.


Storage area mixed with tools/equipment,
chemical, general waste, unused box, file etc.

RECOMMENDATION FOR IMPROVEMENT:

a) To defined the type of the storage area.


b) Remove all the chemical and general
waste.
c) Recommended to provide racking
system.

12. LOCATION: WALKWAY - MAIN OFFICE MEDIUM

Page 15 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

Free standing rack at office walkway. Storage


and placement of equipment/materials at a non-
designated area may expose related persons to
the risk of getting hit by or hitting the material. In
other hand, this condition may lead to damage
of the equipment.

RECOMMENDATION FOR IMPROVEMENT:

a) To immediate remove from walkway and


store the equipment at designated
storage area.

Page 16 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

LOCATION: WALKWAY- MAIN OFFICE MEDIUM


13.

Page 17 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

Battery packs were placed at walkway. This


situation may lead to theft, sabotage, hitting
static objects and misuse of the material.

RECOMMENDATION FOR IMPROVEMENT:

a) To remove from this area and store at


designated storage area.

LOCATION: Office Parameter (Near Cvr MEDIUM


14.
Server Room)

Page 18 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

Improper storage of hazardous substances –


paint bucket.

RECOMMENDATION FOR IMPROVEMENT:

a) The hazardous substances shall be


immediately removed from general area
and be stored at designated storage
area.

LOCATION: CVR SERVER ROOM 1 MEDIUM


15.

Page 19 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

Improper storage of hazardous substances –


Gas Cylinder for Air Conditioning Refrigerant.
Mishandling or tamper with this gas cylinder
may results in serious injury or death.

RECOMMENDATION FOR IMPROVEMENT:

 To immediate remove and disposed off


properly.

LOCATION: OFFICE PARAMETER (NEAR


16. PRAYER ROOM) MEDIUM

Page 20 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

Piled up combustible wastes. This unsafe


condition may lead to fire incident.

RECOMMENDATION FOR IMPROVEMENT:

To immediately remove from this area and


dispose off properly.

LOCATION: OFFICE PARAMETER (NEAR


17. PRAYER ROOM) MEDIUM

Page 21 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

Storage of material at undesignated storage


area. This condition may expose the equipment
to theft, misuse and damage. By not being
secured and unsafely stacked, it may expose
personnel to a risk of getting hit by falling object.

RECOMMENDATION FOR IMPROVEMENT:

a) The material shall be immediately


removed from this area and be disposed-
off properly or be stored at a designated
storage area.

18. Signage LOCATION: ALL HAND WASHING STATION

Page 22 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

Low
OBSERVATION:

Lack of information, poster or signage on the


recommended handwashing technique.

RECOMMENDATION FOR IMPROVEMENT:

To display hand washing step poster and ensure


it follow MOH guideline.

Personal Protective Low


19. LOCATION: OPERATION STORAGE ROOM
Equipment (PPE)

Page 23 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

Improper storage of safety helmet. Improper


storage will reduce the effectiveness of the shell,
quality and it can lead to damage.

RECOMMENDATION FOR IMPROVEMENT:

a) To store properly at own workstation or


specific PPE rack.
b) To clean safety helmet, both the shell
and suspension system, regularly. Only
use mild soap and rinse with warm
water, as cleaning solvents can weaken
the head protection.
LOCATION: CVR SERVER ROOM 1 Medium
20. Security

Page 24 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

An unmaintained and poor housekeeping of


server room. The access door was not locked.
Unauthorized person can enter the CVR Server

Page 25 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

Room. This situation may lead to theft,


sabotage, misuse of facility and damages to the
equipment of which potentially lead to fire
incident.

RECOMMENDATION FOR IMPROVEMENT:

a) To conduct regular houskeeping.


b) The caretaker of the room shall be
clearly identified.
c) In preventing any unwanted incident
such as fire and misuse of facility which
may affect Allo’s premise and personnel,
the server room shall be make good and
maintained.
d) To lock all the CVR room and put the
signage to indicate the room belong to
CVR.
e) Caretaker or responsible party contact
information shall be clearly displayed.

21. Fire System LOCATION: MAIN OFFICE Medium

Page 26 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

OBSERVATION:

Unmaintained, unlocked and poor condition of


fire hose reels cabinet. This condition may lead
in delay or failure in an emergency response
and may expose the equipment to theft and
misuse.

RECOMMENDATION FOR IMPROVEMENT:

a) Building owner to ensure all the fire


system propely maintained and ready to
be used during emergency.
b) To conduct annual checks of the
physical and pressure and flow of each

Page 27 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

of fire system that shall be carried out by


certified an external contractor. Records
of these tests shall will be kept and
maintained.

22. LOCATION: LAB ROOM MEDIUM

OBSERVATION:

Missing 1 fire extinguisher unit.

Page 28 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

RECOMMENDATION FOR IMPROVEMENT:

a) To replace with new fire extingusher.


b) To ensure all the fire system propely
maintained and available to use during
emergency.

23. Chemical LOCATION: CVR SERVER ROOM 1 MEDIUM

OBSERVATION:

Improper storage of chemical. This condition


may expose related personnel to drink or
misuse the chemical.

RECOMMENDATION FOR IMPROVEMENT:

Page 29 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

a) To store the chemical at designated area


b) To label the chemical as per Use and
Standard Exposure of Chemicals
Hazardous to Health Regulation 2000.

24. Others LOCATION: ANNEX OFFICE (CUSTOMER MEDIUM


SERVICE)

OBSERVATION:

Peeled/broken floor vinyl. This unsafe condition


may expose related personnel/ customer to trips
and falls.

RECOMMENDATION FOR IMPROVEMENT:

Page 30 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

a) To replace with new vinyl or repair.

Severity Minor Injury Over 3 days Critical


Likelihood First Aid Case injury Fatality or Major Injury

Risk Rating Tolerance


Probable High High High

Possible
High severity andinHigh
timeprobability of major
Medium Medium
injury, disablement or possible High and additional
fatality. Work must cease immediately
HIGH
control measures implemented prior to work commencement.
Negligible
Low Medium Medium
Unlikely to occur
Probability that an incident will occur over time (Over 3 day injury) but not as serious as a major injury or fatality. Additional
MEDIUM
control measures to be implemented within 24 Hrs.

Negligible risk of injury, but task requires additional control measures to reduce likelihood of injury (Minor Injury not above 3
LOW
days off from employed role) Additional control measures to be specified and implemented within 48 Hrs.

Page 31 of 32 ALLO/HSE/SIR/007
ALLO TECHNOLOGY SDN BHD
HSE INSPECTION REPORT

Note: PIC to issue to HSE Unit following close out of actions. Evidence of close out to be provided e.g. photographs including time and date.

Page 32 of 32 ALLO/HSE/SIR/007