Algeria BRN MLE

Gas Pipeline

PROCESS DATA PRESSURE SAFETY VALVES - FUEL GAS

EX-DE 01 23/06/2020 Issued for Design (Revised where indicaterd) A.Pillitteri M. Di Gregorio S.Sacco
EX-DE 00 13/03/2020 Issued for Design F.Maiorano A.Pillitteri S.Sacco
Validity Revision
Contractor Company
Status Number Date Description Prepared Checked Approved
Approval Approval
Revision index
Company logo and business name Project name Company Document ID

Algeria BRN MLE 140706DPGA14328


Gas Pipeline
Job N. JA0051
Contractor logo and business name Contractor identification

Contractor N
Vendor logo and business name Vendor identification

Order N
Facility and Sub Facility Name: MLE Location: Algeria MLE CAFC Scale Sheet of Sheets

n.a. 1/5
Document Title Supersedes N.

Superseded by N.
PROCESS DATA PRESSURE SAFETY VALVES - FUEL GAS Plant area Plant unit
n.a. n.a.
Software: Microsoft Excel File Name:140706DPGA14328_EXDE01_05
This document is property of Enis.p.a. .
It shall neither be shown to Third Parties not used for purposes other than those for which it has been sent.
Sheet of Sheets
Company Document ID
2/5
Validity
Revision Number
140706DPGA14328 Status
EX-DE 01

Project/Initiative Name Algeria BRN MLE Gas Pipeline


Document Title PROCESS DATA PRESSURE SAFETY VALVES - FUEL GAS
Abstract

Document Verification

Prepared by Unit Signature Date

A.Pillitteri 23/06/2020
Contractor

Checked by Unit Signature Date


M. Di Gregorio 23/06/2020
Approved by Unit Signature Date

S.Sacco 23/06/2020

Verified by Unit Signature Date


Company Interdisciplinary

Verified by Unit Signature Date


Review

Verified by Unit Signature Date

Checked by Unit Signature Date


Company
Checked

Checked by Unit Signature Date

Approved by Unit Signature Date


Company
Approved

Endorsed by Unit Signature Date

This document is property of Eni S.p.a, it shall neither be shown to Third Parties not used for purposes other those for which it has been sent
Sheet of Sheets
Company Document ID
3/5
Validity Revision
140706DPGA14328 Status Number
EX-DE 01

REVISION LIST

EX-DE_00 Issued for Design


EX-DE_01 Issued for Design (Revised where indicated)

HOLD RECORD

GENERAL NOTES

This document is property of Eni S.p.a, it shall neither be shown to Third Parties not used for purposes other those for which it has been sent
Sheet of Sheets
Company Document ID
4/5
Validity Revision
Status Number
140706DPGA14328
EX-DE 01

ITEM REVISION SHEET ITEM REVISION SHEET

420-PSV-501AH/BH 00 01 5

This document is property of Eni S.p.a, it shall neither be shown to Third Parties not used for purposes other those for which it has been sent
Sheet of Sheets
Company Document ID
5/5
Validity Revision
Status Number
140706DPGA14328
EX-DE 01

PROCESS DATA PRESSURE SAFETY VALVES - FUEL GAS Rev.

1 ITEM 420-PSV-501AH/BH (1) 01


2 SERVICE Electric Heater 420-H-01 DEVICE TYPE PRESSURE SAFETY VALVE
3 MIN. NUMBER OF DEVICES 2 No. OF SPARE DEVICES 1 NUMBER OF IDENTICAL DEVICES 2 01
4 SET / BURST PRESSURE bar-g 45 OVERPRESSURE % 10 01
5 BACKPRESSURE bar(g) CONSTANT VARIABLE max 11,7 (3)
6 CALCULATION ACCORDING TO API 520/521 JACKET
7 PROCESS NOTES:
8
9
10 RUN DESCRIPTION
11 FLUID DESCRIPTION Fuel Gas (4) OPERATING TEMPERATURE °C 20 - 81 01
12 SPECIAL SERVICES n.a. OPERATING PRESSURE bar(g) 31.45 - 35.0 01
13 GASEOUS PHASE TYPE @ SET COND.
14 GAS OR VAPOR PHASE LIQUID PHASE
15 INTERVENTION CAUSES REL. TEMP. FLOW MW Z Cp/Cv FLOW DENSITY VISCOSITY
16 °C kg/h kg/h kg/m³ cP
17 Fire 275 785 21.68 0.9958 1.147
18 Overheating (5) 150 2309 21.68 0.956 1.191
19
20
21
22
23
24
25
26 ERROR OF OPERATION DESCR. OTHER INTERVENTION CAUSE DECR.
27 PROTECTED ITEMS FLUID PHASE LATENT HEAT OF VAP. EXP./ WET. AREA ENV. FACT. DES. PRES. DES. TEMP.
28 @ OPERAT. CONDITION kJ/kg m² F bar(g) °C
29 Electric Heater 420-H-01 Gas - 7.5 (2) 45 250 01
30
31
32
33
34
35
36
37
38
39 NOTES
40 (1) P&ID No.14706DPFM14341
41 (2) Surface of Heater plus 50% of additional area that consider 100 m of piping with size 6". 01
42 (3) Hot Flare backpressure as per sheet 15, par. 5 of doc. No. MLE-00-RT-C-00OO06.
43 (4) Fuel gas with content in CO up to 1.83 % in mol and a content of water of 100 ppmw. 01
44 (5) Overheating scenario consider that the maximum gas temperature is equal to 150°C, the skin temperature of Electric Heater. 01
45 Electric Heater supplier shal be confirm that this value is not exceeded. 01
46
47
48
49

This document is property of Eni S.p.a, it shall neither be shown to Third Parties not used for purposes other those for which it has been sent