Professional Documents
Culture Documents
START UP
Name Model Tmp C CC Rq CC
CURRENT
°C kW kW A
GF WING A RXQ40TASYM 35 99 96 80
GF WING B RXQ40TASYM 35 100.7 100.7 80
TOTAL START UP CURRENT DRAWN BY FOR OUTDOORS 160
START UP
Name FCU Tmp C Rq TC Max TC Airflow
CURRENT
°C kW kW l/s A
Ind 1 FXMQ140PVE 24.0 / 50% 14 15.3 767 3.4
Ind 2 FXMQ200MVE9 24.0 / 50% 18 21.5 967 8.1
Ind 3 FXMQ200MVE9 24.0 / 50% 18 21.5 967 8.1
Ind 4 FXMQ140PVE 24.0 / 50% 14 15.3 767 3.4
Ind 5 FXMQ200MVE9 24.0 / 50% 18 21.5 967 8.1
Ind 6 FXMQ140PVE 24.0 / 50% 14 15.3 767 3.4
Ind 7 FXMQ200MVE9 24.0 / 50% 18 21.5 967 8.1
Ind 8 FXMQ200MVE9 24.0 / 50% 18 21.5 967 8.1
Ind 9 FXMQ200MVE9 24.0 / 50% 18 21.5 967 8.1
Ind 10 FXMQ200MVE9 24.0 / 50% 18 21.5 967 8.1
Ind 11 FXMQ140PVE 24.0 / 50% 14 15.3 767 3.4
Ind 12 FXMQ140PVE 24.0 / 50% 14 15.3 767 3.4
TOTAL START UP CURRENT DRAWN BY FOR INDOORS 73.7
START UP
Name Model Tmp C CC Rq CC
CURRENT
°C kW kW A
SF WING A RXQ38TASYM 35 99 96 71
SF WING B RXQ40TASYM 35 100.7 100.7 80
TOTAL START UP CURRENT DRAWN BY FOR OUTDOORS 151
START UP
Name Model Tmp C CC Rq CC
CURRENT
°C kW kW A
FF WING A RXQ38TASYM 35 99 96 71
FF WING B RXQ40TASYM 35 100.7 100.7 80
START UP
Name FCU Tmp C Rq TC Max TC Airflow
CURRENT
°C kW kW l/s A
FF2 Ind 1 FXFQ50LUV1 24.0 / 50% 4.8 5.4 267 0.3
FF2 Ind 2 FXFQ50LUV1 24.0 / 50% 4.8 5.4 267 0.3
FF2 Ind 3 FXFQ50LUV1 24.0 / 50% 4.8 5.4 267 0.3
FF1 Ind 4 FXFQ50LUV1 24.0 / 50% 4.8 5.4 267 0.3
FF1 Ind 5 FXFQ50LUV1 24.0 / 50% 4.8 5.4 267 0.3
GF Ind 6 FXFQ40LUV1 24.0 / 50% 3.6 4.3 250 0.3
GF Ind 7 FXFQ40LUV1 24.0 / 50% 3.6 4.3 250 0.3
GF Ind 8 FXFQ40LUV1 24.0 / 50% 3.6 4.3 250 0.3
FF1 Ind 9 FXFQ50LUV1 24.0 / 50% 4.5 5.4 267 0.3
TOTAL START UP CURRENT DRAWN BY FOR INDOORS 2.7
START UP
Name Model Tmp C CC Rq CC
CURRENT
°C kW kW A
GATE HOUSE
RXQ14TAYM 32 39.6 39.3
OUTDOOR UNIT