COOLING HEATING
244 Maint and Repair (12 Apr. 19) (C) Generated Date Lead/PO# v 29.0.0
Maintenance and Inspection Checklist
Filter Size: X X
BASIC COOLING OR HEATING MAINTENANCE INCLUDES: OK At Risk Fail N/A
Check/Calibrate Thermostat As Required
Inspection Of Air Filtration System
Replacement Of Filter Provided By Customer
Inspect Any Condensate Drain Pans For Proper Operation
Inspect Readily Accessible Ducts For Obvious Air Leaks
Inspect Unit Wiring And Electrical Disconnect
Visually Inspect/Test Capacitors For Leakage And Rust (Indoor Unit)
Inspect Blower Wheel and Lubricate Furnace/Boiler Blower or Air Handler
Inspect Blower Motor And Record Amp Draw (Lubricate As Needed)
Check Crankcase Heater For Proper Operation
Complete Operations Sequence Check
BASIC HEATING MAINTENANCE INCLUDES: OK At Risk Fail N/A
Inspect Flue And Venting For Obstructions And Leaks
Inspect Entire Furnace / Boiler For Loose Or Worn Parts And Abnormal Vibrations
Check Temperature Rise Across Heat Exchanger For Overheating
Check And Adjust Manifold Gas Pressure
Inspect Furnace / Boiler Wiring Assembly For Loose Connections
Inspect Gas Burners
Inspect Burner Ignition System And Assembly
Check High Limit Control (Adjust As Needed)
Inspect Gas Lines And Connections At Furnace / Boiler For Leaks
Inspect Heat Exchanger For Sooting, Corrosion, Cracks And Deformities
Check Electrical Circuit to Furnace/Boiler. Test All Electrical Controls
Inspect Gas Valve For Corrosion, Leaks, Restriction Of Gas Flow And Abnormal Noise
Test And Adjust The Unit For Peak Operating Efficiency
Check Defrost Cycle And Reversing Valve Operation (Heat Pumps Only)
Tighten Screw Lug Terminals In Condensing Unit (Heat Pumps Only)
Check Refrigerant Level (Heat Pumps Only)
Check Emergency Heat Systems For Proper Operation (Heat Pump Only)
MEASUREMENTS RECORDED AT TIME OF INSPECTION (INDOOR/HEATING EQUIPMENT):
Gas Pressure Temperature Rise Hot Surface Igniter Indoor Temperature
Low / High Wet Bulb / Dry Bulb
/ / / /
Inducer Amp Draw Blower Amp Draw Blower Capacitor Flame Sensor
/ / / /
244 Maint and Repair (12 Apr. 19) (C) Generated Date Lead/PO# v 29.0.0
Maintenance and Inspection Checklist
Model: Serial #:
Filter Size: X X
BASIC COOLING MAINTENANCE INCLUDES: OK At Risk Fail N/A
Check Evaporator For Adequate Airflow
Inspect And Flush Condensate Lines And Check Condensate Pump Operation (If Equipped)
Inspect Indoor Coil If Accessible
Inspect Cooling System For Unusual Vibration Or Loose Parts
Check Refrigerant Level (When Outside Temp >60°F)
Check And Record Operating Pressures And Temperatures
Check And Record Amp Draw Of Condenser Motor And Compressor
Inspect Contactor For Pits Or Burns
Tighten Screw Lug Terminals In Condensing Unit
Check Condenser Motor Bearings/Lubricate Unsealed Condenser Motor Bearings (As Necessary)
Inspect Fan Blade For Cracks Or Defects
Inspect And Clean Outdoor Unit* (*Does Not Include Use Of Detergent)
Check Overall Operation Of System
MEASUREMENTS RECORDED AT TIME OF INSPECTION (INDOOR/HEATING EQUIPMENT):
Suction PSI Suction Temp Liquid PSI Liquid Temp
/ / / /
Outdoor Temp Outdoor Fan Amp Compressor Amp Condenser FanAmps
/ / / /
Dual Capacitor
Compressor / Fan
/
COMMENTS:
244 Maint and Repair (12 Apr. 19) (C) Generated Date Lead/PO# v 29.0.0
Recommended Options and Repair Scope of Work
Item Description
Price Explanation
(Please check box for PriorityLevel)
Accept Decline
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Accepted Recommendations Subtotal
Labor and workmanship guarantee (select one). Recommended items which are not purchased/completed are not guaranteed.
90 days 1 year (Maintenance Plan Customers Only)