You are on page 1of 26

RBS 6102/6101 &

BBS/BBU/GBF
6102/6101
Installation

BBS/BBU/GBF
6102/6101
Technical Data

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 1 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
Course Agenda
 Introduction
 RAN System Description and RBS 6000 Survey
 RBS 6102/6101 Technical Data
 BBS/BBU/GBF 6102/6101 Technical Data
 Installation Safety Precautions and Tools
 Site Installation Preparation
 RBS 6102/6101 Installation
 BBS/BBU/GBF 6102/6101 Installation
 Concluding Routines
 Practical Exercises
 Theoretical Assessment and Course Summary

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 2 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
Course Objectives
At the end of this module, you will be able to:

 Learn about the main characteristics of


BBS/BBU/GBF 6102.
 Learn about the main characteristics of
BBS/BBU/GBF 6101

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 3 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6102 Overview

•Outdoor Battery backup system provides -


48VDC backup power to AC mains powered
RBS 6102 in the event of mains failure.

•The BBS can support up to 3 RBS cabinets

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 4 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6102 Overview

Pos. Description
A Breaker Panel
B Battery belt
C BBS Cabinet Frame
D Removable Panel for cable entry
E Climate Unit with FCU or CCU
F Battery 12V/170 Ah or OPzV650
G Front Door
4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 5 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6102 Dimensions

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 6 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6102 Weight

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 7 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6102 Overview

Aproved battery types

Two alternative (plug-in cassettes)


cooling systems:
• Direct Air cooling (fan ventilation)
• Active cooling

Optional heater kit.

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 8 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6102 Overview

Cable dimensions

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 9 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6102 Sealing System

Roxtec position can be either on the bottom or side


MBL (Outdoor Antenna Network Installation > ROXTEC)
4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 10 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBU 6102

•The Battery backup Unit


(BBU) is mounted underneath
the RBS, which saves valuable
floor space
•The footprint area of the BBU
is the same as the RBS 6102
•Available with direct air
cooling and active cooling
alternatives
•Optional heater

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 11 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBU 6102

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 12 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBU 6102

Approved battery types


Dimensions

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 13 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
GBF (Global Base Frame) 6102

2 versions:
•basic (non earthquake proof)
•extended (earthquake proof)
4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 14 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
GBF 6102

Basic base frame Extended base frame

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 15 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6101 Overview

• Outdoor Battery backup system provides -


48VDC backup power to AC mains
powered RBS 6101 in the event of mains
failure.

• The BBS 6101 cabinet supports up to


three RBS 6101

• The BBS 6101 features an active climate


solution which maximizes battery lifetime
in warm climates and battery capacity in
cold climates.

• The battery compartment has space for


three battery strings, each consisting of
four battery blocks.

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 16 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6101 Overview

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 17 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6101 Connection Field

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 18 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBS 6101 External Connections

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 19 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBU 6101 Overview

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 20 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBU 6101 Cable entries

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 21 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
BBU 6101 External Connections

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 22 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
GBF (Global Base Frame) 6101

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 23 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
GBF (Global Base Frame) 6101

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 24 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
GBF (Global Base Frame) 6101

4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 25 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05
4/038 13-LZU 108 7642 Uen, Rev C © Ericsson AB 2010 26 RBS 6102/6101 & BBU/BBS/GBF 6102/6101 Installation 2010-08-05

You might also like