Try to shut the NHT unit in a control way with DSN from T006 (ln this moment H201
temperature will suddenly rise, so close the valve opening of Tlc 0223).
ii. Take Hz storage tank on line and start H2 generator.
iii. Decrease the H201 outlet
iv. By pass R-201when H201temp decreased down to L40oC
lf any sound observe in heater blower then try to adjust VFD accordingly
vi. Finally cool down reactor bed by sweeping with Hz
vii. lf K-301 is ready to run then again line up DSN to C201-D305-C-301 and again start
up the CRU section,

3. P-301Trip (D 301 bottom PumP)


Causes: Low level in D-301, High level in D-303
Consequence: Pressure of D-303 will increase, UV 0901 close (D 303 high level), level of D-301
will increase
Step to be taken:
Y a. lf it is due to low level of D-301
I.CRU feed increase little bit for a while
il. MOS 1r0502
lll. Start pump P-3014 or P-3018 after priming
b. lf it is due to D-303 high level then,
L MOS Ll 0802
ll. Normalize UV 0901
lll. lncrease the opening FCV 802,FCV1001 & FCV 1101
lV. Start pump P-301A or P-301B after priming

4. P-303 Trip (D-305 bottom pump)


Cause: Low level of D-305
Consequence: Low level of C-301, low suction pressure at P-305, P 305 trip, H-304 trip.
Step to be taken:
a. MOS on Ll-1002
b. Try to increase the level of D 305 by increasing FCV 802 for a while if necessary
c. Start P 303 by priming.
5. P-305 Trip (Stabilizer Re-boiler pump)
Cause: Very low level of C-301", very low discharge pressure, Very low discharge flow, UV 1201 in
close position, Mechanical sealtemp high, Mechanical or Electrical fault.
Consequence: Top pressure of C-301 reduces, RVP of Octane will be very high, and level of D-
306 will decrease.
Step to be taken:
a. lf it is due to low level of C 30L then,
l. Mos 111203
ll. lncrease flow of FCV 100L for a while
lll. lf UV 1201close then normalize