(01) NOTES :-
(01) D (01a) GENERAL :
(01a) MESH MESH
1. ALL DIMENSION ARE IN MILLIMETERS & LEVELS ARE IN METER UNLESS OTHERWISE
SPECIFIED.
2. DIMENSIONS SHALL NOT BE SCALED, ONLY WRITTEN DIMENSIONS SHOULD BE
(02) (02) (02) (02) (02) (02) FOLLOWED.
3. THIS DRAWING SHOULD BE IN CONJUNCTION WITH GENERAL ARRANGEMENT DRAWING
7 AND OTHER RELATED DRAWING. 7
D 4. REFER SEPARATE DRAWING FOR SUPER STRUCTURE.
MATERIALS :
(04) (04) 5. REINFORCING STEEL SHALL BE HYSD (TMT) BARS Fe-500, CONFIRMING TO IS-1786
Ld (03) Ld Ld (03) Ld
INCLUDING LATEST AMENDMENTS.
6. GRADE OF CONCRETE SHALL BE AS FOLLOWS:
· ABUTMENT : M35
· ABUTMENT CAP : M35
· PEDESTAL : M40
· PCC LEVELING COURSE : M15
7. CLEAR COVER TO ALL REINFORCEMENT BARS INCLUDING STIRRUPS SHALL BE AS
REINFORCEMENT DETAILS OF ABUTMENT CAP FOR BRACKET DETAILS FOLLOWS:
SCALE 1 : 75 REFER MISC. DRAWINGS · PEDESTAL : 45mm
· PIER & PIER CAP : 50mm
(06) CONSTRUCTION
8. REINFORCING STEEL SHALL BE OF HYSD (TMT) BARS. (GRADE DESIGNATION Fe-500)
(05) CONFIRMING TO TABLE 18.1 OF IRC: 112-2011
6 (07) 6
9. SPLICING OF REINFORCEMENT SHALL BE DONE EITHER BY OVERLAPPING OR BY USING
(01) MECHANICAL COUPLER.
10. OVERLAPPING FOR SPLICING OF REINFORCEMENT SHALL BE AS PER CLAUSE NO. 15.2.5
OF IRC:112.2011.

(LD)

(LD)
LAP LENGTH SHALL NOT BE LESS THAN 60Ø.
(02) LAP ZONE :-
d1@St d1@2St/3 d1@St
300

300
(01a)

(03)
Lp/3+4Ø Lp/3
(04)
(TENSION ZONE)
(p3)

(p3)
d1@St d1@2St/3 d1@St

C C C C SECTION D-D 5
5
(p1) (p1) SCALE 1 : 50 AT LEAST ONE BAR BEYOND Lp/3+4Ø Lp/3
LAPPING ZONE ON BOTH SIDE
300

300
(COMPRESSION ZONE)

WHERE,
d1 = DIA OF TRANSVERSE REINFORCEMENT
300 St = SPACING OF TRANSVERSE REINFORCEMENT
300 (TYP)
(TYP) 11. BAR SHOWN IN THE DRAWING ARE NOT TO BE COUNTED ONLY WRITTEN DATA SHALL
BE FOLLOWED.
12. SUITABLE SPACER PINS SHALL BE PROVIDED BETWEEN ROWS OF MAIN BARS TO
MAINTAIN THEIR CORRECT SPACING.
13. SUITABLE CHAIRS SHALL BE PROVIDED TO SUPPORT AND MAINTAIN CORRECT POSITION
OF REINFORCEMENT (12 mm DIA AS PER IS-2502).
14. DISTRIBUTION REINFORCEMENT SHALL BE WIRED TO MAIN REINFORCEMENT.
15. IF ANY AMBIGUITY FOUND IN DRAWINGS OR AT SITE BRING IT TO DESIGNER'S NOTICE

300
SECTION A-A BEFORE EXECUTION.
4 SCALE 1 : 75 4
MESH
2 NOS.
(p3) (p1)
SHEDULE OF REINFORCEMENT

(09)
(08)
Bar Mark Bar Shape Bar Dia Nos. / Spacing REMARKED

(p3)
(p2)

01 25 0 17 Nos. TOP

(TYP)
500
01a 25 0 17 Nos. TOP
ABUTMENT CAP

SECTION C-C
SCALE 1 : 50 (p3) 02 20 0 6 LEGGED @ 150mm C/C VERTICAL STIRRUPS
(STIRRUPS)

03 12 0 14NOS. SURFACE RING SURFACE RING


3 SECTION F-F 3

04 20 0 17 Nos. BOTTOM SCALE 1 : 20


900
(p2)
75 750 75
DIRT WALL

05 16 0 150 C/C VERTICAL F F


C C
06 20 0 150 C/C VERTICAL (08)
450
37 75

300
38
900

(TYP) 07 10 0 150 C/C HORIZONTAL


PEDESTAL

08 12 0 @ 100mm C/C VERTICAL


450

(TYP)
75

300
80 09 12 0 @ 100mm C/C HORIZONTAL (TYP) TYPICAL PLAN FOR PEDESTAL
75

80 SCALE 1 : 20

2 900 2
20

75 450
SOUTH EAST CENTRAL RAILWAY
SHEDULE OF REINFORCEMENT
20

37 37

HEADQUARTERS APPROVAL
80

Bar Mark Bar Shape Bar Dia Nos. / Spacing REMARKED


PIER

CBE
DETAIL OF MESH-2 p1 25 0 40x2 = 80 VERTICAL
(REINFORCEMENT FOR PEDESTAL-PD 1) DETAIL OF MESH-1 Dy.CE/Br.D
SCALE 1:20 (UNDER JACK LOCATION) p2 25 0 10x2 = 20 VERTICAL
SCALE 1 : 20
SECTION B-B AXEN/ROB
p3 16 0 28 LEGGED @ 150mm C/C LINKS SCALE 1 : 50
SSE/DES
MRIDC
THIS DRAWING IS APPLICABLE FOR ABUTMENT -01 & 02 ONLY
LEGENDS:- SIGN.
SSE/ROB
DESIGNATION
TOP REINFORCEMENT REFERENCES (LATEST REVISIONS) :
APPROVED BY JE/ROB/D
BOTTOM REINFORCEMENT 1. MRIDC NGP/NAB-ITR/ROB/GAD/2021/SECR/LC-33: GENERAL ARRANGEMENT DRAWING OF ROB. RAJ KUMAR SHUKLA
TYP. = TYPICAL 2. MRIDC/NGP/ROB/LC-33/RCC-01(sheet 1 OF 2) : REINFORCEMENT DETAILS FOR PIER (ABT--01) (ADDITIONAL GENERAL MANAGER)
1 TITLE : PROPOSED CONSTRUCTION OF 6 LANE ROB SPAN (1x36.0m) AT 1
PCC = PLAIN CEMENT CONCRETE 3. RDSO/B-11758(Drawing Ref.) : REFERENCE FOR 30.00m RDSO GIRDER
CHECKED BY LC-33/NI-C AT RAILWAY KM-1186/10 (PROJECT CH. 52735 M) BETWEEN
PHANINDRA MAJETI UMRED - BHIWAPUR STATION IN CONNECTION WITH PROPOSED
(MANAGER DESIGN) GAUGE CONVERSION (NG TO BG) OF NAGBHIR-ITWARI SECTION WITH
ELECTRIFICATION.
DESIGNED BY
MAHARASHTRA RAIL INFRASTRUCTURE DEVELOPMENT CORPORATION LTD. SAURABH PANDEY REINFORCEMENT DETAILS OF ABUTMENT & ABUTMENT CAP FOR
A Joint Venture of Govt. of Maharashtra and Ministry of Railway (STRUCTURAL DESIGNER) ABT-01 & 02
2nd Floor, Hoechst House, Nariman Point, Mumbai - 400 021 DRAWN BY SCALE :- AS SHOWN
R0 19-01-2021 SUBMISSION FOR APPROVAL DATE :22.03.2021
TAUQEER ALAM
REV. DATE DESCRIPTION OF REVISIONS (DRAUGHTSMAN) DRG.NO. MRIDC NGP/NAB-ITR/ROB/LC-33/RCC-01 (SHEET 2 OF 2) REV.R-00
A1 A B C D E F G H J