www.solarmanpv.com
WP-1 User Manual
1.General information
This manual is only applicable to SolarMAN weather station WP-1, and shall not
apply to other types.
Definition of signs
Warning
This symbol indicates potential hazard to personal or device. Users should set the
device under the instruction of this manual, otherwise a personal injury or device
damage might occur.
Notice
This symbol indicates the issues that users should take account into. Users should pay
attention to the notice while setting the device, otherwise a device damage might
occur.
2
WP-1 User Manual
Please read the instructions and notes carefully, otherwise personal injury or device
damage might occur if not avoided.
Please make sure that all operations during the device setting are in
compliance with local laws and regulations.
2.2 Attentions
The device must be operated with specific power supply. The working
voltage should be within specified range.
Please do not place the device under high temperature environment, near
open fire, or immersed in any liquid.
Please turn off the power when the device is not working for a long time.
3
WP-1 User Manual
3.Installation instructions
4
WP-1 User Manual
Please check the packing list carefully before installation. If a device defect, accessory
missing, or other problem exit, please contact manufacturer immediately.
Notice
To avoid the equipment damage, please avoid collision while opening the package.Please
do not disassemble connected equipment.
Warning
Lightning rod is an optional equipment. IGEN shall not be liable for any damage
occurred if lightning rod is not installed.
Before installation, please place the lightning rod in a concealed location to avoid any
accident.
5
WP-1 User Manual
Pincer pliers
socket wrench
6
WP-1 User Manual
Impact drill
7
WP-1 User Manual
4. Installation procedures
8
WP-1 User Manual
Some types of weather stations only contain some sensors as shown in the diagram.
Please check your packing list and install the devices following the procedures.
Notice
1. Before delivery, devices are installed and configured inside instrument shelter and
communication box. Please do not disassemble the instrument shelter and
communication box during installation. Please protect the connected wires during
installation.
2. Users may prepare the electrical wires by themselves, or electrical wires could be
ordered with the weather station.
9
WP-1 User Manual
Notice
The wind direction sensor shell has a white south mark point. When
installing bracket, ensure the wind arrow head and tail and the south mark
point to be in one line and align the arrow head to the north.
10
WP-1 User Manual
2. Install wind direction sensor on the arms, adjust pointer head, tail and south pint to be in same
line. Pointer head is at one side of south point.Adjust pole direction and make pointer to be south
and mark the positions of the four screws of the flat stand pole.
11
WP-1 User Manual
When drill the platform, please adjust the direction according to the south mark point, ensure the
direction of the south mark point of the sensor to be south.
12
WP-1 User Manual
1.Requirements : there cannot be any plant or buildings which will keep out the light
within 5 meters around the stand and sensors. Within 10 meters there cannot be any
landform,plant or buildings which will affect the wind speed and direction. The
ground should be smooth and broad. If it is soil surface, please build a cement
foundation (Round cement foundation: diameter: 1.5 m , thickness: min. 25 cm. ), the
tripod should be fixed by expansion screws.
2.In coastal areas, please add a wind cable to make the tripod more wind-resistant.
3.Please arrange the cables according to the client’s requirements and the actual
situation. The electric wires should be covered by PVC tube. Please arrange the
electric cables in wall or air if possible. Cover the PVC tube well to make the cables
water-resistant, and install an airs witch to prevent safety accidents.
13
WP-1 User Manual
14
WP-1 User Manual
15
WP-1 User Manual
Step:
1. Screw the Sensor logger to the pole using hoop.
16
WP-1 User Manual
It is strictly prohibited to connect the power to the power supply during the wiring process.
Step:
1. Pay attention to below point.
There are three stop-positions here and please make them connected rightly and stop
rightly at every position.
17
WP-1 User Manual
18
WP-1 User Manual
2. Attach the male & female head and lock it according to the waterproof aerial head
tag.
19
WP-1 User Manual
3. Attach the male & female head and lock it according to the waterproof aerial head
tag.
Above is a set of waterproof connectors, including 7 parts. Check the tightness before connecting:
1. Slightly loosen 1&2, 6&7 successively;
2. Then slightly loosen 2&3, 4&6(pay attention to the sequence);
3. Tighten 2&3,4&6;
4. Tighten 1&2, 6&7(finally to loosen1&7, otherwise, 2&3, 4&6will not be tightened
completely.)
20
WP-1 User Manual
21