11.

0 DESIGN OF STRUCTURAL MEMBER SOLDIER PILE

Material Properties:
Steel Material Specs: ASTM A572/A572M GRADE 60
Yield Strength of steel = 415 Mpa

Input from Stress Analysis:


Computed moment, M 223.8 KN-m
Computed shear, V 115.6 KN

Design Section:

Section specs W10x10x49

Depth, d 253 mm

Web thickness, Tw 8.6 mm

Flange width, Bf 254 mm

Flange thickness, Tf 14.2 mm


Ix 116,368,037 mm4
Sx 919,905 mm3
Weight 71.46 KG/m
Equivalent Self dead load 0.70 KN/m

Check Flexure:
The beam is laterally-supported w/ compact section
Allowable bending stress Fb = 0.66Fy 273.9 Mpa
Design Beam Sx 919,905 mm3
Required Sx = M / Fb 817,012 mm3
Therefore the beam is SAFE in Flexure

DESIGN ENGINEER CERTIFIED BY


FRANKLIN O. MARINAS FELEMUEL D. BULLOS JR.
Check Shear:
Applied shear load, V 115.6 KN
Actual shear web stress, fv = V / d tw 53 Mpa
Allowable Shear stress, Fv = 0.4 Fy 166 Mpa
Therefore the beam is SAFE in shear

Over-all Evaluation: SAFE

THEREFORE ADOPT THE BEAM/RAFTER W/ THE FF PROPERTIES:

Member Code SOLDIER PILE


Section Name W10x10x49
Properties:
Wt= 71.46 kg/m
h= 253.0 mm
Bf= 254.0 mm
Tw= 8.6 mm
Tf= 14.2 mm
Steel Material ASTM A572/A572M GRADE 60

DESIGN ENGINEER CERTIFIED BY


FRANKLIN O. MARINAS FELEMUEL D. BULLOS JR.
12. DESIGN SKETCH

SOLDIER PILE X
NGL
X=0.2m
H=5.3m
Y=6.5m
H
L=12m

L Spacing=1.2m
DREDGE LEVEL
Section:W10x10x49

13. CONCLUSION
1. The Soldier Piles are stable both in horizontal force and moment.
2. The Soldier Pile materials are capable of carrying imposed stresses.

3. The over-all shoring installation is safe and does not require additional support.

4. The designer is not liable for failure caused by poor workmanship or material defects, if
any.

DESIGN ENGINEER CERTIFIED BY


FRANKLIN O. MARINAS FELEMUEL D. BULLOS JR.