Wind load calculation for roof covering and add-ons - National Research... https://www.nrc-cnrc.gc.ca/eng/services/windrci/calculator/results.html?s...
National Research Council Canada
Home > Wind-Roof Calculator on Internet > Wind load calculation for roof covering and add-ons
Wind load calculation for roof covering and add-ons
Building parameters Building location: Steinbach, Manitoba
Building geometry:
Low-rise building Low-sloped roof (0° < α <= 7°)
Height (reference height): 30 ft (9 m) Width (smaller plan dimension): 70 ft (21 m) Length: 100 ft (30 m)
Building exposure: Open
Building openings: Category 1
Building importance: Low
Wind loads for roof cladding
Roof area Wind load
End zone width, Z 7 ft (2.1 m)
Corner, -50 psf (-2.4 kPa)
Edge, -23 psf (-1.1 kPa)
Field, -17 psf (-0.8 kPa)
(Conversion Unit: 1 ft = 0.3048 m, 1 psf = 47.88 Pa, 1lb/ft2 = 4.8824 kg/m2)