You are on page 1of 3

PROJET:-

PERMOHONAN KEBENARAN MERANCANG MENGIKUT SEKSYSN 21, AKTA


PERANCANGAN BANDAR DAN DESA, 1976 (AKTA 172) BAGI CADANGAN MEROBOH
DAN MEMBINA SEMULA SUBUAH RUMAH IBADAT SATU TINGKAT DAN DEWAN
BERSERTA TANDAS DI ATAS LOT 485,No. 89, JALAN BATU PAHAT- MERSING, MUKIM
KLUANG, DAERAH KLUANG, JOHOR.

INTRODUCTION:
This report describes related information pertaining to select suitable type of sewerage
system for the development of the above mentioned.
1) Land use:-

The proposed one storey temple buildings with toilet in the site are located at lot PTD
485, No. 89, Jalan Batu Pahat- Mersing from the Bandar Kluang. The site is next beside to
existing Taman in the rural area.

Land size:-

The plot land is 0.404 acres where

a) The vicinity has apparently no water course.


b) The underground water table is 1.20 m below the ground level.

POPULATION EQUIVALENT ESTIMATION:-


Population equivalent for temple is 0.2 PE per person as below;-
Design P.E. 0.2 x 120 persons = 24 PE,

Thus, the Roto Moldings septic tank system RS-6 for PE 30 of 9100L capacity is
recommended.
Therefore, an individual septic tank is allowed to be provided, which is standard sewer
treatment system could be used for individual dwelling in the rural area.

This report is intended to present for the owner to select an individual septic tank system,
and for submission to Authority for acceptance of proposal of the type of sewerage system,
that presently available in the approved manufacture production plants in the current
market.
SEWERAGE PROPOSAL:-
This planning submission is an application for each residential dwelling to use one unit
Project Tank Septic System, which with compliance to Guidelines for construction procedure
of standard sewerage system, for treating the toilet and waste water to standard effluent.
The effluent generated from the said sewerage treatment plant system will be discharged to
the out flow of parit from the drainage system.

SEWERAGE TREATMENT PROCESS:-


The Septic tank is an individual septic tank (IST), consisting of two chambers in one tank,
that are septic / separation chamber, and anaerobic filter chamber.
The septic chamber works as setting tank with hydraulic detention time more than 24 hours
which is adequate for a complete bacteria decomposition process. Filter chamber with
plastic filter media acts as optimum bed for the growth of anaerobic bacteria. It also acts as
filter system for the removal of suspended solids from the effluent.

The septic tank is a built unit, lightweight and easy to install. It needs very minimum space
and is used to treat domestic waste water. Quality of effluent discharges from PS-15 Septic
Tank is of standard B based on the Environment Quality (Sewage and Industrial Effluents)
Regulation 1979.