RELAY PROTECTION COORDINATION


DESCRIPTION • Load Flow and Unbalanced Fault Effects
A relay is a device which is operated by a • Cold Load Pickup
variation in its electrical or physical conditions • Grounding System Constraints
to effect the operation of other devices in an • Coordination Economics
electric circuit. A protective relay is a relay, the • Asymmetrical Current Impacts
principal function of which is to protect service • Coordination Time Intervals of Relays
from interruption or to prevent or limit • Transformer Effects on Coordination
damage to apparatus. In electrical engineering, 3. Equipment and Device Characteristics
a protective relay is a device designed to trip a • Fuses –including current limiting fuses
circuit breaker when a fault is detected. The • Molded case and Insulated Case
first protective relays were electromagnetic Breakers
devices, relying on coils operating on moving
• Solid-State Trip Low Voltage Breakers
parts to provide detection of abnormal
• Equipment Damage Characteristics
operating conditions such as over-current,
• Proper Protective Device Selection
over-voltage, reverse power flow, over- and
• Circuit Breaker Ratings and Selection
under- frequency.
The theory and application of these protective • Low Voltage Cable Protection
devices is an important part of the education • Shielded Cable Protection
of an electrical engineer who specializes in • Overhead Conductor Protection
power systems. The need to act quickly to • Motor Protection
protect circuits and equipment as well as the • Generator Protection
general public often requires protective relays • Transformer Protection
to respond and trip a breaker within a few • Panelboard and Switchgear Protection
thousandths of a second. In this course, we • Inverse Time/Overcurrent Protective
gonna learn about: Relays and
Identify the Effects of Current Transformers • Instantaneous Trip Devices
(CTs) on Power Systems Protection. • Series Rated Breakers
Recognize Protective Relay Coordination • Differential and Voltage Constrained
Related Disturbances and Outages. Relays
Collect the Required Data to Perform a • Reclosing relays, reclosers, and
Detailed Coordination Study. sectionalizers
Derive Complete Protective Relay Device • Current transformer characteristics and
Settings to Protect the Electrical Power selection
Systems Equipment. 4. Ground Fault Protection
• Arcing Ground Fault Magnitudes
OUTLINE • Ground Fault Protection Schemes
1. System Analysis • Interaction Of Ground Fault Relays And
• Fault Current and Load Flow Phase
Calculations Using Computer • Overcurrent Devices
Software
• Remote Effects Of Faults
2. Protective Device Coordination Principles
• Graphical Tools and Time/Current
Curve Interpretation
5. Emergency Power System Design
• Weak Source Systems
• Generator Fault Characteristics
• Uninterruptible Power Supply Fault
Characteristics
• Transfer and Static Switch Limitations
• Improving Emergency Circuit Design
6. Common Coordination Problems, Errors,
And Misconceptions
7. Preliminary System One-line Development
for a Coordinated System
• Lessons Learned and “ Rules of Thumb”
to spot uncoordinated systems and
methods to develop a coordinated
system design
8. Criteria Impacting Coordination
• NESC, IEEE Std C2,
• NFPA 70-National Electrical Code
• Arc Flash Protection of Employees
9. Switchgear And Relay Commissioning
Including Optional Hands-On Student
Calibration of a Relay

TRAINING METHOD
Live Presentation via ZOOM
Discussion
Case Study
Pre-Post Test
Evaluation

FACILITY
Handout (Soft File)
Certificate

TIME
16-17 November 2021
Dalam 1 hari terdiri dari 2 sesi
 Sesi 1 : 08.00 - 12.00 WIB
 Sesi 2 : 13.00 - 15.00 WIB

TRAINING FEE
Rp. 3.000.000,-/ peserta
❖ Belum termasuk PPN 10 %
❖ Minimal Running 2 Peserta

You might also like