You are on page 1of 2

Registered office : B-101,Building no.

11,
Mangalmurti Complex,near Mankhurd–Ghatkoper
Cryogenic Techno Works Link Road, Mankhurd, Mumbai -400 043.

Email: cryogenictechnoworks@gmail.com

ULTRASONIC PULSE VELOCITY TEST REPORT

Date: 03/05/2016
Client Ref: 30/04/2016
Test Report No. : CTW/KC/1077/2016

Name & address of client : Kavya Construction.

Site Address : Muktidham Co. Op Hsg. Soc.


Kalwa (E).

Date of testing : 02/05/2016

Test Method Followed : As per IS-13311-1992 part-1

Path
Sr. Structural Time Velocity
Location/ID Mark Method Length Remarks
No Member ( µ.sec ) (Km/sec)
(mm)
GROUND FLOOR
-
Stilt Area
1 Column No. 2 RCC Column Direct 220 109.7 2.00 -
Direct
2 Column No. 3 RCC Column 220 56.4 3.90 -
Direct
3 Column No. 6 RCC Column 220 80.9 2.72 -
Direct
4 Column No. 7 RCC Column 220 71.7 3.07 -
Direct
5 Column No. 9 RCC Column 220 91.6 2.40
Direct
6 Column No. 10 RCC Column 220 77.8 2.83 -
Direct
7 Column No. 11 RCC Column 220 84.8 2.59 -
Direct
8 Column No. 12 RCC Column 220 87.2 2.52 -

9 Column No. 14 RCC Column Direct 220 64.9 3.39 -

10 Column No. 15 RCC Column Direct 220 76.6 2.87

11 Column No. 18 RCC Column Direct 220 81.7 2.69

12 Column No. 22 RCC Column Direct 220 74.6 2.95


Registered office : B-101,Building no.11,
Mangalmurti Complex,near Mankhurd–Ghatkoper
Cryogenic Techno Works Link Road, Mankhurd, Mumbai -400 043.

Email: cryogenictechnoworks@gmail.com

Path
Sr. Structural Time Velocity
Location/ID Mark Method Length Remarks
No Member ( µ.sec ) (Km/sec)
(mm)

13 Column No. 23 RCC Column Direct 220 75.6 2.91

14 Column No. 24 RCC Column Direct 220 98.6 2.23

15 Column No. 27 RCC Column Direct 220 83.3 2.64

16 Column No. 28 RCC Column Direct 220 74.0 2.97

17 Column No. 29 RCC Column Direct 220 66.2 3.32

18 Column No. 31 RCC Column Direct 220 78.2 2.81 -

19 Column No. 33 RCC Column Direct 220 98.2 2.24 -

20 Column No. 34 RCC Column Direct 220 94.6 2.32 -

Remarks:
Velocity below 3.00 Km/sec `DOUBTFUL' Quality of concrete
Velocity between 3.00 to 3.50 Km/sec `MEDIUM' Quality of concrete.
Velocity between 3.50 to 4.50 Km/sec `GOOD' Quality of concrete.
Velocity above 4.50 Km/sec `EXCELLENT' Quality of concrete.

 Test report is related to the structural member under test in as received condition.
 Test report is valid at the time of and under the condition specified herein.
 Test report may not be reproduced in part and can not be used as evidence in the court of law
without written permission of “Cryogenic Techno Works” Mumbai.

Authorized Signatory

You might also like