Domestic cold water

Domestic hot water


KS Kitchen sink
L Laundry
LAV Lavatory
SH Shower head
SS Service sink
WB Wash basin
WC Water closet

potable water service pipe


WH Water heater
Shut-off Valve
Check Valve
Pipe section Up/Down
Pipe section parameters:
20mm Ø CW Nominal Diameter,mm Cold/Hot water
2.60m Length,m

A B B' C D E F MAIN G H
ENTRANCE
50mm Ø CW

-0.38=19.82

W1 W1 W1 W1
-0.25=19.95
W1 W1
-0.50=19.70
32mm Ø CW
150
140

150
140

150
140

150
140

150
140

150
140
200
205
4.40m
1

ED1
90 90 90 90 90 90
32mm Ø CW SH
1.00m · All dimensions are in meters, unless otherwise
WC stated.
20mm Ø HW LAV · All horizontal pipelines should be measured on site.
1.20m 20mm Ø HW · Pipes will be cPVC, schedule 40.
32mm Ø CW 20mm Ø CW 1.00m
20mm Ø CW · Material used in any part of a plumbing system
1.00m SH 1.20m
0.60m 1.1 29.00 m² shall be free from defects and conform to ASTM
KS
20mm Ø HW 20mm Ø CW SS F441 .
WC 0.60m 150 · Installations shall adhere manufacturers
1.10m 50mm Ø CW

W1
90
25mm Ø CW 140 recommendations.
32mm Ø CW
LAV 6.40m
SH 1.30m 20mm Ø HW 20mm Ø CW · The water distribution pipe and branches shall be
1.12 14.05 m² 1.10m 1.14 11.73 m² ±0.00=20.20
2.10m 2.60m of sizes shown on the drawing.
1.2 33.63 m²
SHOWERS 25mm Ø HW 20mm Ø CW TOILETS - MALE LABORATORY · Hot water will be supplied by a water heater.
1.50m 1.20m 1.15 36.57 m² · All piping above grade shall be properly supported
KITCHEN 25mm Ø CW by the building structure and shall not rest on
32mm Ø CW 6.10m 20mm Ø HW
WC 0.50m ceiling structure or components.
1.30m · In a horizontal run of piping, the supports shall be
WB WH placed at intervals of not more than - 6 feet for
1.11 17.44 m² 1.13 4.11 m²
SS pipes of 3 4" or smaller, 8 feet for pipes from 3 4 " to
LOCKER ROOM - MEN 25mm Ø HW UNISEX ACCESSIBLE
D1 100 40mm Ø CW
D2 90
3 1 2".
205 1.80m 1.30m
TOILET 205
· Vertical piping shall be supported and anchored
LAV with strong metal rests at intervals not more than 4
205

205

205
100

D1

90

90
feet.
2 50mm Ø CW
205
100
D1

D2

D2
20mm Ø CW 3.15m
20mm Ø HW
0.50m 20mm Ø CW 7.30m
20mm Ø HW 7.50m

205
1.20m

90
ED2
±0.00=20.20 40mm Ø CW DD1 160
STAFF 100
25mm Ø HW 4.30m 205
205 40mm Ø CW
ENTRANCE

D2
4.90m 32mm Ø HW
25mm Ø HW 3.85m 1.5 35.80 m² 50mm Ø CW D2 90
20mm Ø CW CORRIDOR 4.20m
5.50m 10.00m 205
-0.32=19.88 1.20m
D1

D1

D2

D2
20mm Ø HW
3 1.30m
205

205

205

205
100

100

32mm Ø HW
90

90
LAV
40mm Ø CW 2.00m 1.3 16.81 m²
1.10 16.00 m² OFFICE AND
LOCKER ROOM - D1 100 3.50m LAV WH 32mm Ø CW 150

W1
90
205 2.70m MICROLABORATORY 140
WOMEN 20mm Ø HW
WC 25mm Ø HW 1.6 29.53 m²
4.40m 3.60m L
1.9 12.89 m² RESTING ROOM

205
32mm Ø CW 20mm Ø CW 20mm Ø CW

90
LAV
SHOWERS 1.00m 1.20m 1.60m
1.8 9.57 m² L
1.7 8.90 m²

D2
SH
TOILETS - FEMALE LAUNDRY
20mm Ø HW
32mm Ø CW
1.15m
1.10m
1.4 15.08 m²
SH LABORATORY 150

W1
90
20mm Ø HW 140
32mm Ø CW 1.20m
1.10m
WC WC
SH

90 90 90 90 90 90
4
140
150

140
150

140
150

140
150

140
150

140
150
32mm Ø CW 25mm Ø CW 20mm Ø CW
4.40m 1.00m 1.10m
W1 W1 W1 W1 W1 W1
Project Planning and decon international Alpha Engineering & Design
Management Ltd. GMBH (2012) Ltd

A B B' C D' E F G H

WATER AND SEWERAGE AUTHORITY


SYSTEM OPTIMIZATION DEPARTMENT
CAD/E UNIT

HEAD OFFICE, VALSAYN, ST.JOSEPH. PHONE: (809)


662-2302 - 7 FAX: (809) 645-9907