You are on page 1of 1

WATER LEGEND LEGEND OF DEGRASS PVC ELEVATED TANK

(NOMINAL CAPACITY 1100 LITRES)


COLD WATER TUBERIA DRAIN TUBERIA

HOT WATER TUBERIA VENTILATION TUBERIA

RISE ELBOW 45O ELBOW


Cold Water Rises
90O ELBOW 90O ELBOW from T.C. to T.E.
ROTOPLAST TANK
BEDROOM BEDROOM ROOF CAPACITY 1100 Liters
TEE HEALTH YEE Tub. 3/4"
Drainage exit
Low
By T.E. Fund . . . . . . . . . . . . . . . . . . . . . . . . ."
GATE VALVE TEE Low Cold Water Overflow
T.E. to Feeders 2"

WATER POINT ROSCADO REGISTRATION


Tub. 1/2"
M METER SINK Submerged Pump
TO TO'
VALVULA CHECK TRAP
1/2" PVC

1/2" PVC
1/2" CPVC

1/2" CPVC
Tank
Cistern REDUCTION REGISTRATION BOX(0.30 x 0.60)

Suction
Pump
1"
IRRIGATION TAP CIEGA BOX (0.30 x 0.60)
3/4" PVC

1/2" PVC

PLANT

1/2" CPVC
1/2" CPVC

1/2" PVC
1/2" PVC

1/2" PVC
SCALE 1/25
Come and get A.F. to T.E. Come A.F. to T.E.
3/4" PVC 3/4" PVC
Low A.F. de T.E.
3/4" PVC
1/2" PVC 1/2" PVC 3/4" PVC
PVC cover

3/4" PVC
1/2" PVC 1/2" PVC
Niple Special

3/4" PVC
Go up A.F. to T.E. Comes A.F. from T.E.
COLD WATER TUBERIA 1/2" PVC

3/4" PVC 3/4" PVC


Tank Float valve 1/2"
High 3/4" PVC Departure from Ventilation
GATE VALVE Input Overflow
0.05
C Water

KITCHENETTE to) The gtote vtolve must be insttolled in the pltoces


BEDROOM where the project is indicated, walls will not be allowed
installation on floors.
Submerged Pump

B
COLD WATER TUBERIA 1/2" PVC

b) Before installing the valve, it must be checked for its herme- 3/4" Low
tismo. Go up Tub. Drive

3/4" PVC
Overflow
c) The valve will be located between two universal joints comes from the Cistern ROTOPLAST TANK
flat-seat or equivalent system, to allow 2"
repair and/or maintenance by removing the valve without
CAPACITY 1100 Liters
ROOF TO C FIG. 1 cut the pipe.
d) The niche designed to house the valve and joints
Valvula Chek 1/2"
ROOM universal, of the dimensions indicated will go on the wall.
It will have a wooden frame and door, with a fixer or handle and Niple Special 1/2"
snap-on system.
DINING ROOM e) Care should be taken to place the valve and joints
COLD WATER TUBERIA 1/2" PVC

Key
KITCHEN B so as not to hinder its operation. Universal 1/2"
Reduction

3/4" PVC
Departure from 2" at 3/4"
Water
PVC or HYDRO - 3 GALVANIZED IRON
To the System Niple Special 3/4"

FIG. 2 Ø TO B C Ø TO B C
Key
C T.E. Base
1/2" PVC TO 1/2" 20 15 7 1/2" 20 20 7
Concrete Armed
Universal 3/4"
Cleaning Pipe
3/4" 25 15 7 3/4" 20 20 7 3/4"
1" 25 20 10 1" 25 25 10
Pass-through Key 3/4"
Comes A.F. from T.E. Low A.F. de T.E.
11/2" 30 25 10 11/2" 30 30 10
3/4" PVC 3/4" PVC
Al Ungrate
FIG. 1, 2 AND 3 (MEASUREMENTS IN CM.) FIG. 2 AND 3 (MEASUREMENTS IN CM.)
B CUTTING A-A'
NOTE:
1/2" PVC 1.- The diameter of the gate valves will be SCALE 1/25
1/2" PVC
the same as the corresponding pipe.
2.- Valves shall be installed in trunks or niches
according to the top frame.
TO FIG. 3

1/2" PVC

TANK TANK DETAIL


ESC 1/25

.10 .15
DINING .50

ROOM SALIDA DE AGUA FRIA SALIDA DE AGUA CALIENTE SALIDA DE AGUA FRIA
COLD WATER TUBERIA 1/2" PVC

COLD WATER TUBERIA 1/2" PVC

.15 .15 .15


.30 .55
.10
.25

STORE ROOF .15


Overflow 2"
1/2" .25
Overflow 2"
.60
0,55 0,55 .10
SALIDA PARA DESAGUE 0.47 0.47 SALIDA PARA DESAGUE .30
0.10 0.10

Trap 2"

.15 .15
.15
1"

ROOM DETAIL WATER OUTPUTS AND WATER IN LAVATORIOS


CAPACITY
2.00 m3 1.50
1.00 Suction
Pump
Tank
1"
Cistern
1.375

A Drive goes to T.E.


1.50
CAP. 2.00 m3

3/4" PVC
.50 .15
.225
.15
SALIDA DE AGUA FRIA
M

ALTERNATIVA DE EN MURO .15


SALIDA EN MURO .15 .15
0.15
MATRIZ NETWORK

MATRIZ NETWORK
IT COMES FROM

IT COMES FROM

1.50
1.00
.15 .15
.15 .15
0,21 0,21 CUT

1/2" PVC
Power
PLANT
ALTERNATIVA DE
SALIDA EN EL PISO SALIDA DE DESAGUE

SECOND LEVEL ROOF


0.32

FIRST LEVEL ESC: 1/50


ESC: 1/50 ESC: 1/50 DETAIL WATER OUTPUTS AND WATER IN INODOROS