Professional Documents
Culture Documents
Torit Downflo Evolution 2: Specifications Model Dfe 4-16
Torit Downflo Evolution 2: Specifications Model Dfe 4-16
30.00 42.00
762 1067
CLEARANCE 100.66 CLEARANCE SPECIFICATIONS
FOR 2557 FOR
AIR VALVE ELEMENT
MODEL DFE 4-16 D
SERVICE 95.34 SERVICE
2422 NO. OF FILTERS 16
27.00
686 CLEANOUT AMM EXPLOSION VENT (OPTIONAL)
20.79 [528] X 36.00 [914] ACCESS
COVERED ACCESS/OUTLET TM
SEE DETAIL 121.00
HOPPER DONALDSON MEMBREX
(CLEAN AIR TRANSTIONAL 48.00 3073
SEE DETAIL NOMINAL SIZE: 34 X 46 [864 x 1168]
OPTIONAL) 1219 FOR FLANGE RELIEF AREA: 8.52 FT² [0.79 m²]
PATTERN NOMINAL BURST PRESSURE: 1.45 psig [0.1 bar]
PRESSURE
TAP LOCATIONS
NOTES:
47.97 35.13 1 DO NOT INSTALL OR OPERATE THIS EQUIPMENT UNTIL HAVING
20.00
1218 892 READ AND UNDERSTOOD THE INSTRUCTIONS AND WARNINGS
EDAP 30 INCH
508
IN THE INSTALLATION AND OPERATION MANUAL. FOR A REPLACEMENT
86.61 MANUAL CONTACT DONALDSON COMPANY, INC. (800) 365-1331.
AMM RIGHT SHOWN 2200
2 NFPA 68-2013 B
EXPLOSION VENT DUCTING LONGER THAN ONE HYDRAULIC DIAMETER
.75
19
26X .343
OR WITH BENDS, ELBOWS OR OBSTRUCTIONS ENTAILS SIGNIFICANT
9 DERATING OF THE EXPLOSION VENT. ALL PROPOSALS INCLUDING
23.50 EXPLOSION VENT DUCTS OTHER THAN SHORT, STRAIGHT OPEN
597 27.13 DUCTS SHOULD ALSO BE REFERRED TO DCI ENGINEERING FOR
689 VENT PERFORMANCE CALCULATION AND DERATING, OR CUSTOM VENT
ROOF INLET (TOP)
(OPTIONAL) SEE DETAIL 18.80 24.00 SOLUTION. ANY EXPLOSION VENT DUCTING TO BE DESIGNED AND
610 SUPPLIED BY OTHERS.
478
3 ACTUAL COMPRESSED AIR CONSUMPTION MAY VARY DUE TO FEED PIPING
DESIGN, PROXIMITY TO ACCUMULATION TANKS, UPSTREAM FLOW DEMAND
Thursday, April 01, 2021 1:40:03 PM
14.10
AMM INLET AND OTHER COMPRESSED AIR SYSTEM EFFECTS.
(OPTIONAL) 358
SEE DETAIL 4 DIMENSIONS ARE IN INCHES AND [MILLIMETERS].
9.40 22.00
239 559
12X .438 [11]
32.00 EQLSP ON A
4.70
813 25.88 [657] BC
119
0
.75 THIS DOCUMENT IS NOT CERTIFIED FOR CONSTRUCTION PURPOSES
0
19 AND IS SUBJECT TO CHANGE WITHOUT NOTICE.
SECTION A-A MATERIAL RELEASE NO.2014A01487 TITLE DFE 4-16 WITH AMM, EDAP, A
EDAP 30 INCH
DATE 11/17/2014 HOPPER AND LEGS
AG8272106_A_SECT.SLDDRW
12.56
20.94
33.50
16.75
25.13
29.31
ROOF INLET
8.38
4.19
106
213
319
425
532
638
745
0
0
851
EXP DATE
DFE AG8272106
DWN E ORNELAS NUMBER
AMM RIGHT SHOWN REFERENCE DATE 11/18/2014
R
CHK T RAETHER
DETAIL B
® ® 2
Donaldson Co. Inc.
DATE 11/18/2014 SCALE NONE SHEET 1 OF 3 REVISION Minneapolis,USA
AMM INLET
8 7 6 5 4 3 2 1
8 7 6 5 4 3 1
30.00 42.00
762 1067
CLEARANCE 100.66 CLEARANCE
FOR 2557 FOR
AIR VALVE 95.34 ELEMENT
SERVICE
2422
SERVICE
A A D
68.43
1738 79.79 ROOF INLET 45 INCH
EDAP ACCESS EDAP SEE DETAIL A
3.07 36.16 BOTH SIDES 2027
78 FOR OPENING SIZE AND
918 HOLE LOCATION
EXTENDED DIRTY
AIR PLENUM
SPRINKLER
45.00 COUPLING
1143 1"NPT
MANIFOLD (2 PLCS)
AIR INLET
1" NPT AMM INLET LOCATION
(BOTH ENDS) (OPTIONAL)
205.00 SEE DETAIL B FOR
OPENING SIZE AND HOLE
5207 LOCATION
OPTIONAL EXPLOSION FILTER
VENT ACCESS
192.50 COVER 27.13
4890 85.00 689
2159 24.00
610 C
INSPECTION COVER 215.19 AIR MANAGEMENT
CLEAN AIR PLENUM 5466 MODULE (AMM)
27.00
PRESSURE TAP 686 CLEANOUT AMM
ACCESS 121.00
LOCATIONS 3073
HOPPER
SEE DETAIL
48.00 FOR FLANGE 12X .438 [11]
20.79 [528] X 36.00 [914]
COVERED ACCESS/OUTLET 1219 PATTERN EQLSP ON A
SEE DETAIL 25.88 [657] BC
(CLEAN AIR TRANSITIONAL
OPTIONAL)
47.97 35.13 20.00
1218 892 508
86.61
SECTION A-A
ROOF INLET
EDAP 45 INCH WITH EXPLOSION VENT
2200
EXPLOSION VENTED (TOP)
(OPTIONAL) SEE DETAIL AMM RIGHT SHOWN
(SHEET 3)
.75
19
ROOF INLET (TOP) 26X .343 B
(OPTIONAL) SEE DETAIL 9
23.50
597
18.80
478
14.10
Thursday, April 01, 2021 1:40:03 PM
20.94
33.50
16.75
25.13
29.31
MATERIAL 2014A01487 DFE 4-16 WITH AMM, EDAP, A
8.38
RELEASE NO.
4.19
TITLE
106
213
319
425
532
638
745
0
0
851
DATE 11/17/2014 HOPPER AND LEGS
AG8272106_A_SECT.SLDDRW
EXP DATE
® ® 2
AMM INLET APPROX. WT: 5312.92 LBS DATE 11/18/2014 SCALE NONE 2 3 REVISION
Donaldson Co. Inc.
8 7 6 5 4 3 2 1
8 7 6 5 4 3 1
75.61
1920
11.00 24.00
279 610
9.39
11.00 239
D
279
66.25
48.88 1683
1241
.94 HOLES
33.13 24
841
22.31 24.00
567 9.39 610
8.00 239
17.80 40.00 203
452 1016 8.00
36.38 203
924 3X 7.44
FRONT OF COLLECTOR 189
PLAN VIEW
OPTIONAL EXPLOSION
VENTS SHOWN ANCHOR BOLT PLAN
ANCHOR BOLTS BY OTHERS. FINAL SELECTION WILL DEPEND ON .50 HOLES
JOBSITE LOAD CONDITIONS, FOUNDATION DESIGN, LOCAL CODES, ETC. 13 C
CONSULT PRODUCT IOM FOR GENERAL INSTALLATION INFORMATION. 3X 7.44
189
22.31
567
40.00
HOPPER FLANGE DETAIL
1016
36.00
914
23.00
104.46 584
2653 14.50
368 20.78
528
3X 4.83
B
123
4.25
108
.75
19 6X 4.92
2.00
39.65 125
Wednesday, March 31, 2021 2:00:24 PM
51
1007
4.25 29.50
108 749 .343 HOLES
1.00 38.00 9
25 965
EXP DATE
2200
DFE AG8272106
DWN E ORNELAS NUMBER
® ®
CHK T RAETHER
2
Donaldson Co. Inc.
8 7 6 5 4 3 2 1