9.1 Formwork 8
9.2 Placing of concrete 9.1
9.3 Compation 9.2
9.4 Curing 9.3
10 Providing and laying Cast in
situ/Ready Mix cement concrete M-20
of trap / granite/quartzite/ gneiss metal
for R.C.C. columns (GF) as per
detailed designs and drawing or as
directed including steel centering,
formwork, cover blocks,
laying/pumping, compaction finishing
the formed surfaces with cement
mortar 1:3 of sufficient minimum
thickness to give a smooth and even
surface or roughening if special
finish is to be provided and curing etc. 10 Column Casting 8
complete.(Excluding reinforcement
and structural steel).with
fully automatic micro processor based 3.877 Cu.m 3
PLC with SCADA enabled reversible
Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc.
complete. With fine aggregate
(Crushed sand VSI Grade)
10.1 Formwork 8
10.2 Steel Reinforcement placing 10.1
10.3 Concrete Placement 10.2
10.4 Compaction 10.3
10.5 Curing 10.4
11 Providing and fixing frame(GF)
with / without ventilator of size as
specified with Country non teak wood
for
doors and windows including 0.172 Cu.m 11 Fixing Door Frame 1 10
chamfering, rounding, rebating, iron
holdfast of size 300mm x 40mm x
5mm
with oil painting, etc. complete.
13.1 Formwork 12
13.2 Steel Reinforcement placing 13.1
13.3 Concrete Placement 13.2
13.4 Compaction 13.3
13.5 Curing 13.4
14 Providing and laying Cast in
situ/Ready Mixcement concrete M-20
of trap/ granite/ quartzite/ gneiss metal
for
Concrete R.C.C.Loft(GF) as per
detailed design and drawings including
steel centering, formwork, cover
blocks,
laying/pumping, compacting and
roughening the surface if special finish 14 Loft Casting 12
is to be provided and curing complete.
(Excluding reinforcement and
structural steel). with fully automatic 2.4698 Cu.m 2
micro processor based PLC
with SCADA enabled reversible Drum
Type mixer/ concrete Batch mix plant
(Pan mixer) etc.
complete. With fine aggregate
(Crushed sand VSI Grade
14.1 Formwork 12
14.2 Steel Reinforcement placing 14.1
14.3 Concrete Placement 14.2
14.4 Compaction 14.3
14.5 Curing 14.4
15 Providing and laying Cast in
situ/Ready Mixcement concrete M-20
of trap/ granite/ quartzite/ gneiss metal
for
Concrete R.C.C.Chajja(GF) as per
detailed design and drawings including
steel centering, formwork, cover
blocks,
laying/pumping, compacting and
roughening the surface if special finish
is to be provided and curing complete.
(Excluding reinforcement and 15 Chajja Casting 12
structural steel). with fully automatic
micro processor based PLC
with SCADA enabled reversible Drum 0.656 Cu.m 2
Type mixer/ concrete Batch mix plant
(Pan mixer) etc.
complete. With fine aggregate
(Crushed sand VSI Grade
15.1 Formwork 12
15.2 Steel Reinforcement placing 15.1
15.3 Concrete Placement 15.2
15.4 Compaction 15.3
15.5 Curing 15.4
16 Providing and laying Cast in
situ/Ready Mix cement concrete in M-
20 of trap / quartzite /granite /gneiss
metal for R.C.C. Waist slab, and
steps of staircases(GF) as per detailed
design and drawings or as
directed including steel centering,
formwork, steel props,
laying/pumping, compaction, finishing
uneven
and honeycombed surface with C.M.
1:3 of sufficient minimum thickness to
give a smooth and even surface
or roughening the surface if special
finish is to be provided and curing etc. 16 Staircase Casting 13
complete. (Excluding
einforcement, including cover block).
(Newly laid concrete shall be covered 2.085 Cu.m 3
by gunny bag, plastic, tarpaulin
etc.) with fully automatic micro
processor based PLC with SCADA
enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer)
etc. complete. With fine aggregate
(Crushed sand VSI Grade
16.1 Formwork 13
16.2 Steel Reinforcement placing 16.1
16.3 Concrete Placement 16.2
16.4 Compaction 16.3
16.5 Curing 16.4
17 Providing and laying Cast in
situ/Ready Mix cement concrete M-20
of trap / granite/quartzite/ gneiss metal
for R.C.C.Beam(GF) as per detailed
designs and drawings or as directed
including steel centering, formwork,
cover blocks, laying/pumping,
compactionand roughening
the surface if special finish is to be
provided and curing etc. complete.
(Excluding reinforcement 17 Beam Casting 12
and structural steel). with fully
automatic micro processor based PLC
with SCADA enabled reversible 6.185 Cu.m
Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With
fine aggregate (Crushed sand
VSI Grade)
17.1 Formwork 12
17.2 Steel Reinforcement placing 17.1
17.3 Concrete Placement 17.2
17.4 Compaction 17.3
17.5 Curing 17.4
10
18 Providing and laying Cast in
situ/Ready Mix cement concrete M-20 10
of trap/ granite / quartzite/ gneiss
metal for R.C.C. slabs and
landings(GF) as per detailed designs
and drawings including steel centering,
formwork, cover blocks,
laying/pumping, compaction finishing
the formed surfaces with cement
mortar 1:3 of sufficient minimum
thickness to give a smooth and even
surface or roughening if special finish
is to be provided and curing etc. 18 Slab Casting 12
complete,(Excluding reinforcement
and structural steel).with fully
automatic 8.782 Cu.m
micro processor based PLC with
SCADA enabled reversible Drum
Type mixer/ concrete Batch mix plant
(Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade
18.1 Formwork 12
18.2 Steel Reinforcement placing 18.1
18.3 Concrete Placement 18.2
18.4 Compaction 18.3
18.5 Curing 18.4
19 Providing and laying Cast in
situ/Ready Mix cement concrete M-20
of trap / granite /quartzite/ gneiss metal
for R.C.C. columns(FF) as per
detailed designs and drawing or as
directed including steel centering,
formwork, cover blocks,
laying/pumping, compaction finishing
the formed surfaces with cement
mortar 1:3 of sufficient minimum
thickness to give a smooth and even
surface or roughening if special finish
is to be provided and curing etc. 19 Column Casting 18
complete.(Excluding reinforcement
and structural steel).with
fully automatic micro processor based 3.877 Cu.m 4
PLC with SCADA enabled reversible
Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With
fine aggregate (Crushed sand VSI
Grade)
19.1 Formwork 18
19.2 Steel Reinforcement placing 19.1
19.3 Concrete Placement 19.2
19.4 Compaction 19.3
19.5 Curing 19.4
20 Providing and fixing frame(FF) with /
without ventilator of size as specified
with Country non teak wood for
doors and windows including
chamfering, rounding, rebating, iron
holdfast of size 300mm x 40mm x 0.172 Cu.m 20 Fixing Door Frame 1 19
5mm
with oil painting, etc. complete.
22.1 Formwork 21
22.2 Steel Reinforcement placing 22.1
22.3 Concrete Placement 22.2
22.4 Compaction 22.3
22.5 Curing 22.4
23 Providing and laying Cast in
situ/Ready Mixcement concrete M-20
of trap/ granite/ quartzite/ gneiss metal
for
Concrete R.C.C.Loft(FF) as per
detailed design and drawings including
steel centering, formwork, cover
blocks,
laying/pumping, compacting and
roughening the surface if special finish
is to be provided and curing complete.
(Excluding reinforcement and 23 Loft Casting 21
structural steel). with fully automatic
micro processor based PLC
with SCADA enabled reversible Drum 2.4698 Cu.m 3
Type mixer/ concrete Batch mix plant
(Pan mixer) etc.
complete. With fine aggregate
(Crushed sand VSI Grade
23.1 Formwork 21
23.2 Steel Reinforcement placing 23.1
23.3 Concrete Placement 23.2
23.4 Compaction 23.3
23.5 Curing 23.4
24 Providing and laying Cast in
situ/Ready Mixcement concrete M-20
of trap/ granite/ quartzite/ gneiss metal
for
Concrete R.C.C.Chajja(FF) as per
detailed design and drawings including
steel centering, formwork, cover
blocks,
laying/pumping, compacting and
roughening the surface if special finish
is to be provided and curing complete.
(Excluding reinforcement and 24 Chajja Casting 21
structural steel). with fully automatic
micro processor based PLC
with SCADA enabled reversible Drum 0.474 Cu.m 3
Type mixer/ concrete Batch mix plant
(Pan mixer) etc.
complete. With fine aggregate
(Crushed sand VSI Grade
24.1 Formwork 21
24.2 Steel Reinforcement placing 24.1
24.3 Concrete Placement 24.2
24.4 Compaction 24.3
24.5 Curing 24.4
25 Providing and laying Cast in
situ/Ready Mix cement concrete in M-
20 of trap / quartzite /granite /gneiss
metal for R.C.C. Waist slab, and
steps of staircases(FF) as per detailed
design and drawings or as
directed including steel centering,
formwork, steel props,
laying/pumping, compaction, finishing
uneven
and honeycombed surface with C.M.
1:3 of sufficient minimum thickness to
give a smooth and even surface
or roughening the surface if special
finish is to be provided and curing etc. 25 Staircase Casting 22
complete. (Excluding
einforcement, including cover block).
(Newly laid concrete shall be covered 2.085 Cu.m 5
by gunny bag, plastic, tarpaulin
etc.) with fully automatic micro
processor based PLC with SCADA
enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer)
etc. complete. With fine aggregate
(Crushed sand VSI Grade
25.1 Formwork 22
25.2 Steel Reinforcement placing 25.1
25.3 Concrete Placement 25.2
25.4 Compaction 25.3
25.5 Curing 25.4
26 Providing and laying Cast in
situ/Ready Mix cement concrete M-20
of trap / granite/quartzite/ gneiss metal
for R.C.C.Beam(FF) as per detailed
designs and drawings or as directed
including steel centering, formwork,
cover blocks, laying/pumping,
compactionand roughening
the surface if special finish is to be
provided and curing etc. complete.
(Excluding reinforcement 26 Beam Casting 21
and structural steel). with fully
automatic micro processor based PLC
with SCADA enabled reversible 6.185 Cu.m
Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With
fine aggregate (Crushed sand
VSI Grade)
26.1 Formwork 21
26.2 Steel Reinforcement placing 26.1
26.3 Concrete Placement 26.2
26.4 Compaction 26.3
26.5 Curing 26.4
15
27 Providing and laying Cast in
situ/Ready Mix cement concrete M-20 15
of trap/ granite / quartzite/ gneiss
metal for R.C.C. slabs and
landings(FF) as per detailed designs
and drawings including steel centering,
formwork, cover blocks,
laying/pumping, compaction finishing
the formed surfaces with cement
mortar 1:3 of sufficient minimum
thickness to give a smooth and even
surface or roughening if special finish
is to be provided and curing etc. 27 Slab Casting 21
complete,(Excluding reinforcement
and structural steel).with fully
automatic 8.309 Cu.m
micro processor based PLC with
SCADA enabled reversible Drum
Type mixer/ concrete Batch mix plant
(Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade
27.1 Formwork 21
27.2 Steel Reinforcement placing 27.1
27.3 Concrete Placement 27.2
27.4 Compaction 27.3
27.5 Curing 27.4
28 Providing and laying Cast in
situ/Ready Mix cement concrete M-20
of trap / granite /quartzite/ gneiss metal
for R.C.C. columns (TF) as per
detailed designs and drawing or as
directed including steel centering,
formwork, cover blocks,
laying/pumping, compaction finishing
the formed surfaces with cement
mortar 1:3 of sufficient minimum
thickness to give a smooth and even
surface or roughening if special
finish is to be provided and curing etc. 28 Column Casting 27
complete.(Excluding reinforcement
and structural steel).with fully
automatic micro processor based PLC 0.849 Cu.m 4
with SCADA enabled reversible Drum
Type mixer/ concrete Batch mix plant
(Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)
28.1 Formwork 27
28.2 Steel Reinforcement placing 28.1
28.3 Concrete Placement 28.2
28.4 Compaction 28.3
28.5 Curing 28.4
29 Providing and fixing frame(TF) with /
without ventilator of size as specified
with Country non teak wood for doors
and windows including chamfering,
rounding, rebating, iron holdfast of 0.03048 Cu.m 29 Fixing Door Frame 1 28
size 300mm x 40mm x 5mm with oil
painting, etc. complete.
31.1 Formwork 30
31.2 Steel Reinforcement placing 31.1
31.3 Concrete Placement 31.2
31.4 Compaction 31.3
31.5 Curing 31.4
12
32 Providing and laying Cast in
situ/Ready Mix cement concrete M-20 12
of trap/ granite / quartzite/ gneiss
metal for R.C.C. slabs and
landings(TF) as per detailed designs
and drawings including steel centering,
formwork, cover blocks,
laying/pumping, compaction finishing
the formed surfaces with cement
mortar 1:3 of sufficient minimum
thickness to give a smooth and even
surface or roughening if special finish
is to be provided and curing etc. 32 Slab Casting 30
complete,(Excluding reinforcement
and structural steel).with fully
automatic 1.44 Cu.m
micro processor based PLC with
SCADA enabled reversible Drum
Type mixer/ concrete Batch mix plant
(Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade
32.1 Formwork 30
32.2 Steel Reinforcement placing 32.1
32.3 Concrete Placement 32.2
32.4 Compaction 32.3
32.5 Curing 32.4
33 Providing internal cement
plaster(GF)12mm thick in single coat
in cement mortar 1:4 without neeru
finish to concrete or brick surfaces, in 33 Internal Plaster 18.5
all positions including scaffolding and
curing etc.complete.
214.28 Sq.m 8
33.1 Surface preparation 18.5
33.2 Preparing the mortar 33.1
33.3 Applying mortar 33.2
33.4 Levelling 33.3
33.5 Curing 33.4
34 Providing internal cement Ceiling
plaster(GF) 12mm thick in single coat
in cement mortar 1:4 without neeru
finish to concrete or brick surfaces, in 34 Internal Ceiling Plaster 33
all positions including scaffolding and
curing etc.complete.
79.102 Sq.m 4
34.1 Surface preparation 33
34.2 Preparing the mortar 34.1
34.3 Applying mortar 34.2
34.4 Levelling 34.3
34.5 Curing 34.4
35 Providing rough cast cement plaster
externally(GF) in two coats to
concrete, brick or stone masonry
surfaces in all positions with base coat
of 12 to 15 mm thick in C.M. 1:4 and
rough cast treatment 12mm thick in 35 External Plaster 34
proportion 1:1 1/2:3 including
scaffolding and fourteen days curing
complete. 147.598 Sq.m 8
75.1 Formwork 63
75.2 Placing of concrete 75.1
75.3 Curing 75.2
76 Providing cement based water
proofing treatment to terraces (Indian
water proofing or alike) with brick bats
laid in required slope to drain the
water for any span after cleaning the
base surface. Applying a coat
of.cement slurry admixed with
approved water proofing compound
and laying the brick bats on bottom
layer in C.M.1:5 admixed with
approved water proofing compound
filling up to half depth of brick bats,
curing this layer for 3 days, applying
cement slurry over this layer joints of
brick bats with C.M.1:3 admixed with
approved water proofing compound 76 Water proofing for slab 75
and finally top finishing with average 82.337 Sq.m 3
20 mm. thick layers of same mortar
added with jute fiber at 1Kilogramper
bag including finishing the surface
smooth with cement slurry admixed
with approved water proofing
compound. Marking finished surface
with false squares of 300mm x 300
mm. making the junctions at the
parapet rounded and tapered top for
required height, with drip mould at
the junction of plaster and parapet and
curing and covering 10 years
Guarantee against leakproofness
on Court fee stamp paper of Rs. 500/-
including ponding test etc. complet 76.1 Laying of course 75
76.2 Curing 76.1
77 Providing weathered pointing with
cement mortar 1:3 for stone/ Brick
masonary including scaffolding and 22.476 Cu.m 77 Pointing 2 75
curing etc. complete
Head Mason-
2, Mason-6,
1 - - 8050 354 354 14493.11 14493.114
Mazdoor-10,
Sundries - 8
Cement-34
bag, Sand-
4.625 cum,
2.4 0 21648.75 1087.5 5538 1508 13330.72
Metal below
20mm-6.85
cum
Cement-33
bag, Sand-
3.7797 cum, Head Mason-
Metal below 0.25, Mason-
3 28011.47 3112.5 6666 1987 75259.14 22433.23
20mm- 1, Mazdoor-8,
6.1183 cum, Bhisti - 1
Steel -0.5713
MT
Cement-7
bag, Sand-
Head Mason-
0.82 cum,
1, Mason-1,
4.4 Metal below 8578.35 1875 12987 4962 16337.646 6242.196
Mazdoor-3,
20mm-1.33
Bhisti -1
cum, Steel
-0.08257 MT
Cement-79
Head Mason-
bag, Sand-
2, Mason-59,
5 17.31 cum, 171341 52575 5134 1995 253978.98 98692.65
Mazdoor-99,
Rubble-61.83
Bhisti - 10
cum
2, Mason-59,
5 17.31 cum, 171341 52575 5134 1995 253978.98 98692.65
Mazdoor-99,
Rubble-61.83
Bhisti - 10
cum
Murum,Exca
Mazdoor-3,
6 vated 1500 113 113 4186.085 4186.085
Bhisti -2
material
Cement-29
bag, Sand- Head Mason-
3.89 cum, 1, Mason-2,
7.3 17301 1900 6365 1508 47145.555 11169.756
Metal below Mazdoor-2,
20mm-5.77 Bhisti - 1
cum
Cement-2
bag, Sand-
Mason-0.25,
0.2 cum,
6 Mazdoor-0.50, 1140 306.25 13137 5652 1773.495 763.02
Metal below
Bhisti - 0.25
20mm-0.4
cum
Cement-22
bag, Sand-
2.60 cum,
Black smith-2,
8.5 Metal below 27153.5 12987 4962 50350.599 19237.674
Mazdoor-3
20mm-4.21
cum, Steel-
0.2623 MT
Carpenter-
10 0.25, 99553 128 17123.12 22.016
Mazdoor-1,
Head Mason-
Cement-6 0.50, Mason-
33 bag, Sand- 7, Mazdoor- 264 192 20882.928 15187.584
1.04 cum 12, Bhisti
-0.50
Head Mason-
Cement-17
6, Mason-177,
18.5 bag, Sand- 531 399 78374.538 58891.602
Mazdoor-269,
3.27 cum
Bhisti -24
Head Mason-
Cement- 3
1, Mason-4,
34 bag, Sand- 1155 257 47560.59 10582.746
Mazdoor-6,
0.76 cum
Bhisti -1
Cement- 0.5 Mason-1,
36 bag, Sand- Mazdoor-1, 1227 332 4341.126 1174.616
0.0628 cum Bhisti -0.25
Head Mason-
Cement- 2 0.25, Mason-
34 bag, Sand- 1, Mazdoor- 1743 336 20086.332 3872.064
0.230 cum 1.5, Bhisti
-0.20
-0.20
Head Mason-
Cement- 1 0.25, Mason-
34 bag, Sand- 1, Mazdoor- 1157 336 9870.367 2866.416
0.170 cum 1.5, Bhisti
-0.20
Cement- 1 0.25, Mason-
34 bag, Sand- 1, Mazdoor- 1157 336 9870.367 2866.416
0.170 cum 1.5, Bhisti
-0.20
Head Mason-
Cement- 2 0.20, Mason-
40 bag, Sand- 5, Mazdoor-9, 1226 410 26560.677 8882.445
0.433 cum Bhisti -1,
Polisher-21
Head Mason-
Cement- 2 0.10, Mason-
34 bag, Sand- 2, Mazdoor-4, 4138 414 50276.7 5030.1
0.243 cum Bhisti -0.5,
Polisher-10
Mason-0.10,
Cement- 0.5
Mazdoor-0.50,
42 bag, Sand- 4005 313 2703.375 211.275
Bhisti -0.10,
0.0125 cum
Polisher-2
Carpenter-5,
35 7030 1194 116698 19820.4
Mazdoor-7,
Carpenter-5,
Mazdoor-
44 1845 298 41549.40 6710.96
7,Black smith-
2
Carpenter-4,
Mazdoor-
45 2152 926 23155.52 9963.76
5,Black smith-
1
Head Mason-
Cement-23
3, Mason-32,
27.5 bag, Sand- 264 192 56638.56 41191.68
Mazdoor-51,
4.56 cum
Bhisti -3
Head Mason-
Cement-6 0.50, Mason-
47 bag, Sand- 7, Mazdoor- 264 192 20882.928 15187.584
1.04 cum 12, Bhisti
-0.50
Head Mason-
Cement-17
6, Mason-177,
27.5 bag, Sand- 531 399 78374.538 58891.602
Mazdoor-269,
3.27 cum
Bhisti -24
Head Mason-
Cement- 3
1, Mason-4,
48.5 bag, Sand- 1155 257 44052.855 9802.237
Mazdoor-6,
0.76 cum
Bhisti -1
Cement- 0.5 Mason-1,
50 bag, Sand- Mazdoor-1, 1227 332 3909.222 1057.752
0.0628 cum Bhisti -0.25
Head Mason-
Cement- 2 0.25, Mason-
48 bag, Sand- 1, Mazdoor- 1743 336 20086.332 3872.064
0.230 cum 1.5, Bhisti
-0.20
-0.20
Head Mason-
Cement- 1 0.25, Mason-
48 bag, Sand- 1, Mazdoor- 1157 336 9870.367 2866.416
0.170 cum 1.5, Bhisti
-0.20
Cement- 1 0.25, Mason-
48 bag, Sand- 1, Mazdoor- 1157 336 9870.367 2866.416
0.170 cum 1.5, Bhisti
-0.20
Head Mason-
Cement- 2 0.20, Mason-
54 bag, Sand- 5, Mazdoor-9, 1226 410 26560.677 8882.445
0.433 cum Bhisti -1,
Polisher-21
Head Mason-
Cement- 2 0.10, Mason-
48 bag, Sand- 2, Mazdoor-4, 4138 414 50276.7 5030.1
0.243 cum Bhisti -0.5,
Polisher-10
Mason-0.10,
Cement- 0.5
Mazdoor-0.50,
56 bag, Sand- 4005 313 2703.375 211.275
Bhisti -0.10,
0.0125 cum
Polisher-2
Carpenter-5,
49.5 7030 1194 116698 19820.4
Mazdoor-7,
Carpenter-5,
Mazdoor-
58.2 1845 298 31217.40 5042.16
7,Black smith-
2
Carpenter-4,
Mazdoor-
57.5 2152 926 12395.52 5333.76
5,Black smith-
1
Head Mason-
Cement-4
2, Mason-10,
32.5 bag, Sand- 264 192 9804.96 7130.88
Mazdoor-12,
0.67 cum
Bhisti -5
Head Mason-
Cement-2
0.50, Mason-
61 bag, Sand- 264 192 2397.12 1743.36
7, Mazdoor-
0.16 cum
12, Bhisti -1
Head Mason-
Cement-5
5, Mason-15,
32.5 bag, Sand- 531 399 24955.938 18752.202
Mazdoor-20,
0.85 cum
Bhisti -2
Mazdoor-1,
55.5 6006 624 12012.00 1248
Bhisti -2
Mazdoor-1,
55.5 3742 2214 7484.00 4428
Bhisti -2
Mazdoor-1,
57 2758 373 5516.00 746
Bhisti -1
Mason-0.50,
48 Mazdoor-1, 401 198 2736.02 1350.954
Bhisti -1
Head Mason-
0.25, Mason-
63.5 6030 1659 7121.43 1959.279
1, Mazdoor-2,
Bhisti -2
Head Mason-
4, Mason-8,
75 1080 571 88923.96 47014.427
Mazdoor-8,
Bhisti -2
Head Mason-
0.25, Mason-
75 169 146 3798.44 3281.496
2, Mazdoor-2,
Bhisti -0.20
Head Mason-
1, Mason-16,
77 7116 1273 169930.08 30399.24
Mazdoor-15,
Bhisti -4
Mazdoor-
78 5,Black smith- 1917 252 11502.00 1512
3
Description Quantity Rate Amount
Cement bag 350 0
Sand 1200 0
Aggregate 900 0
Total 0
Head m 1 622 622
Mason 0 622 0
Mazdoor 22 560 12320
Bhisti 2 592 1184
Total 14126