You are on page 1of 6

SEM

Composition
Total Mositure
Proximate Analysis
Volatile Matter
Ash
Fixed Carbon
Gross Heating Value
Sulfur

Ultimate Analysis
Moisture
Ash
Carbon
Hydrogen
Sulfur
Oxygen
Nitrogen

Initia
Parameter
Fluegas Temperature
Initial Temperature of Air
Initial Temperature of Fuel
Excess air
Carbon refuse
Carbon to Carbon Monoxide
Aftheo
Afactual
mass of fuel for super heater
mass of fuel for economizer
Total mass of fuel
cp of flue gas

Combustion Gas Pr
Parameter
GCV
GCV
Combustion products on a basis of 1 kg with ultimate analysis of semirara coal
CO2
CO
O2
N2
humidity ratio of vapor
H20
Dry Gas analysis for total gas of moles
Mass portion of combustion gas per mol
CO2
N2
O2
CO
Carbon in the refuse
Ash in refuse
Weight in Refuse
Wg

Boiler Efficienc
Parameter
Percentage heatloss due to dry flue gas
Percentage heat loss due to evaporation of water formed due to H2 in fuel
Percentage heat loss due to evaporation of moisture present in fuel
Percentage of humidity losses
Stack Losses
Unburnt Losses
Unaccountabel losses
Manufacturer Margine
Total of Losses
Boiler Efficiency
SEMIRARA COAL
Value Unit
19 %

20.7
19 %
26.3 %
20934 kJ/kg
1 %

19 %
6.72 %
55.34 %
2.51 %
0.64 %
14.98 %
0.81 %

Initial Parameters
Value Unit
140 0C
27 0C
30 0C
25 %
10 %
5 %
6.6115575 kga/kgf
8.264446875 kga/kgf
14.0750907881387 kg/s
1.88839394170938 kg/s
15.9634847298481 kg/s
0.962964 kJ/kg k

Combustion Gas Products for Boiler Efficiency


Value Unit
30.92487 MJ/kg
30924.87 kJ/kg
rara coal
3.36229666666667 kgco2/kg fuel
0.064563333333333 kgco/kg fuel
0.604830335 kgo2/kg fuel
6.3551952 kgn2/kg fuel
0.022716488512102 kgv/kga
0.438616488512102 kh20/kgfuel
0.324593871778274 molgas/kgfuel

0.235419827597768
0.699246895511011
0.058229528072117
0.007103748819104
0.05534 Crefuse/kgfuel
0.0672
0.12254
4.798708916667 kgdg/kgfuel

Boiler Efficiency using Indirect Method


Value Unit
1.68851537437316 %
0.582118645614355 %
0.489608422606142 %
0.130803357297864 %
2.30892715427717 %
4 %
0.5 %
1 %
10.6999729541687 %
89.3000270458313 %
Remarks
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal

Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal

Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal
Based on Batangas Coal Fired Power Plant Brochure that uses Semirara Coal

Remarks
Initial Assumption
Initial Assumption
Initial Assumption
Initial Assumption
Initial Assumption
Initial Assumption
11.5C+34.5(H-O/8)+4.3(S)
Afideal(1+%excess air)
mf1= (%n)(ms) (Qa1+Qa2)/HHV(boiler eff)
mf2=(%n)(ms)(Qa3)/HHV(boiler eff)
mf=mf1+mf2
At 140 degree celsius

er Efficiency
Remarks
25.284 (M) + 30.572 (Ash) + 62.127 (VM) + 138.117 (FC) - 2890.095
Converted to kJ/kg

44/12 (1-(CO+CO2))*C
28/12(CO*C)
.232(%excessair)(Aftheo)+(16/2)(CO*C)
.768(Afactual)+N2
0.622(Pv)/(P-Pv); Pv=Psat@27C, Pv= 3.567 kPA
9H2+%moisture+Wv
CO2/44+ CO/28 +O2/32+N2/28
Carbone refuse in percent * C
Given
kgrefuse/kgfuel
((4CO2+O2+700)/3(CO2+CO))(Cab/100)

Method
Remarks
m * Cp * (Tf – Ta) * 100 / GCV
9 *H2 * [584 + Cp *(Tf-Ta)] *100 / GCV
M *[584 + Cp * (Tf-Ta)] * 100 / GCV
M(Cp*(Tf-Ta)*100/GCV

Based on Boiler basis calculation, Table A14, page 105

100-Total Losses