"IN SYNC" PARALLEL CONTROL PANEL

MAIN FEATURES
The In-Sync device equips the Visa generating sets to satisfy the operating
requirements of the most complex systems. In Sync is the best solution
available on the market as it offers the most varied configuration and
management options. There are two main configurations: PGE & PRE (parallel
between gensets and parallel with the mains), obtained using a single device
through programming and possible implementation of hardware. The reliability
and very high degree of customisation make Visa gensets equipped with the In-
Sync device, units that are able to satisfy the most complex requirements. In
Sync allows the customer to build multi-generating set Power Stations that can
rationalise fuel consumption while maintaining maximum safety and extending
the life of the systems. As with all Visa products, all the unit's parts are subject
to a strict operating test involving over 30 checks prior to delivery.

CONFIGURATION EXAMPLES EXAMPLE PICTURE

PGE910 LOAD SHARING CONFIGURATION

This allows the load to be powered simultaneously by two or more units


connected in parallel with no synchronisation with the mains.

PGE 9620 LOAD MANAGEMENT CONFIGURATION

The load management function allows automatic start-up and shutdown limits
of the units to be set according to the load variation. The power usually
required by the master generating set is optimised at 75% of the rated power,
and when there are broad and slow variations the slave gensets (one or more
sets) are automatically switched off when the load is low.

PRE910S "IMPORT" PARALLEL WITH THE MAINS CONFIGURATION

With this option the customer's load can be connected to the mains, setting a
maximum power absorption threshold. Once this value is exceeded the
generating set operates in parallel with the mains, thereby supplying the
excess load. This prevents sanctions or disconnections from the mains due to
overloads.

PRE930S "BASE LOAD" PARALLEL WITH THE MAINS


CONFIGURATION

This option allows the genset to run for the main supply of the load. As long as
the load is less than the set power, it is entirely supplied by the generator; the
excess will be supplied by the mains.

N.A.= not available; O.R. = on request. Reference conditions standard ISO8528-1: temperature 25 °C, altitude 1-1000 m. A.M.S.L., 30% relative humidity, 100 kPa atmospheric pressure (1 bar), 0.8
delayed power factor, load applied balanced not distorting. The data provided is subject to variation without prior notice.

Visa S.p.A. via I° Maggio, 55 31043 Fontanelle (TV) Italy Tel: +39 0422 5091 Fax: +39 0422 509350
Mail: visa@visa.it Web: www.visa.it SAP 109000000029-001-00 19-03-2015
1.3
"IN SYNC" PARALLEL CONTROL PANEL

MAIN FEATURES
Considering the complexity of the plants and the wide range of
programming, it is always recommended to contact Visa technical
department in advance.

CONFIGURATION EXAMPLES EXAMPLE PICTURE

PRE930S "BASE LOAD" PARALLEL WITH THE MAINS


CONFIGURATION

This option allows the genset to run for the main supply of the load. As long as
the load is less than the set power, it is entirely supplied by the generator; the
excess will be supplied by the mains.

"AUTOMATIC FROM REMOTE CONTROL" CONFIGURATION

The basic version of the In-Sync device has an input for a potential free
contact called SYS Start/Stop. Close the contact for the In-Sync device (in
AUTO mode) to automatically start-up and shutdown the genset, thereby
controlling the start-up times and circuit breaker on board the unit, whilst also
turning the engine off automatically if a fault occurs. The genset start-up can
be controlled if a suitable device is connected to this input, which activates the
opening and closure of the contact (e.g. clock, manual selector, power
presence sensor, radio control, etc.).

PRE940S CONFIGURATION: "AUTOMATIC" FOR SPTM EMERGENCY

The automatic In-Sync device version for a mains emergency (and short
parallel with it when it is restored), allows a system to be controlled
automatically according to a pre-set cycle, thereby causing the genset to start-
up in the event of a power failure, the user system to be powered and the
genset to be shutdown once normal conditions are restored. The main
advantage of using In-Sync is that synchronisation can be implemented once
the power is restored and the load can be gradually shifted from the unit to the
mains without the typical voltage dip in changeover panels.

N.A.= not available; O.R. = on request. Reference conditions standard ISO8528-1: temperature 25 °C, altitude 1-1000 m. A.M.S.L., 30% relative humidity, 100 kPa atmospheric pressure (1 bar), 0.8
delayed power factor, load applied balanced not distorting. The data provided is subject to variation without prior notice.

Visa S.p.A. via I° Maggio, 55 31043 Fontanelle (TV) Italy Tel: +39 0422 5091 Fax: +39 0422 509350
2.3 Mail: visa@visa.it Web: www.visa.it SAP 109000000029-001-00 19-03-2015
"IN SYNC" PARALLEL CONTROL PANEL

MAIN FEATURES
Considering the complexity of the plants and the wide range of
programming, it is always recommended to contact Visa technical
department in advance.

PRACTICAL AND COMPACT REMOTE MANAGEMENT

A convenient display allows access A SINGLE CONNECTION WITH


to all main configurations as well as USB OR RS232 SERIAL PORT,
monitor the system’s operating requires: -IN SYNC software -USB or
parameters. RS232 cable (not provided).

A MULTIPLE CONNECTION
WITH USB OR RS232 SERIAL
PORT, requires: -IN SYNC software
The main feature of the device is its -USB or RS232 cable (not provided)
compactness. All necessary -iG-MU module.
components are conveniently
A MULTIPLE CONNECTION
installed in the genset’s standard
WITH USB OR RS232 SERIAL
control panel without needing to add
PORT AND GSM MODEM,
further panels.
requires: -IN SYNC software -USB or
RS232 cable (not provided) -GSM
modem (not provided).
PROTECTIONS ALARMS INTERFACE
A SINGLE CONNECTION WITH
-Temperature -Oil pressure -Fuel level -Radiator level -Oil level -Engine LAN, requires: -IN SYNC software
speed -Mains and generator voltage -Voltage asymmetry -Phase inversion -USB or RS232 cable (not provided)
-Synchronoscope and indicator slip during synchronising -Current supplied -Ethernet LAN connection.
displayed -Active, reactive and apparent power for each phase and total
-Power factor -Gen set frequency -Hours counter for energy -Power inversion A MULTIPLE CONNECTION
-In case of more than one genset in parallel, active genset’s power sum and WITH LAN, requires: -IN SYNC
reserve available power -Missed parallel alarm -Battery voltage -Emergency software -Ethernet LAN connection
push button -Starting attempts counter -History of functions and alarms. -iG-IB module -DONGLE module.
COMMUNICATIONS: Inputs and outputs with settable volt free contacts are
available upon request. The device is equipped with a RS232 serial port with
MODBUS protocol support; monitoring, programming and controlling the A SINGLE CONNECTION VIA
generating set directly from a local PC or remotely through special software INTERNET, requires: -IN SYNC
via serial port, LAN, internet or SMS. software -USB or RS232 cable (not
provided) -Analog, digital or GSM
EXTENSIONS modem (not provided) -iG-IB module
-internet connection.
The In Sync’s modular structure allows it to be upgraded for more complex
operations in order to provide better solutions for the various client A MULTIPLE CONNECTION VIA
applications. Depending on the features, the system can be equipped with: INTERNET, requires: -IN SYNC
-engine preheater kit and battery charger kit -automatic fuel refilling system software -USB or RS232 cable (not
(FUEL TUTOR)on board -Fiscal measurement system -Motorized automatic provided) -internet connection -iG-IB
transfer switch panels (ATS). module -DONGLE module -Analog,
digital or GSM modem (not
provided).

N.A.= not available; O.R. = on request. Reference conditions standard ISO8528-1: temperature 25 °C, altitude 1-1000 m. A.M.S.L., 30% relative humidity, 100 kPa atmospheric pressure (1 bar), 0.8
delayed power factor, load applied balanced not distorting. The data provided is subject to variation without prior notice.

Visa S.p.A. via I° Maggio, 55 31043 Fontanelle (TV) Italy Tel: +39 0422 5091 Fax: +39 0422 509350
Mail: visa@visa.it Web: www.visa.it SAP 109000000029-001-00 19-03-2015