Professional Documents
Culture Documents
Contractor
Client
Stanchion
Concrete Grade Beam
A142 BRC Mesh 6 Y1201 @ 175 mm c/c
100 mm Mass Concrete Slab
Section A - A
A A
100mm thick slab underneath tiles
01
03 Assumed Soil bearing capacity = 62 kPa
04 Drawings are not to scale
Section A - A
Rev Date Description Drawn by
01 14/08/21 Foundation layout Kitchen and Dinning E. Nwankwo
Notes SHEET NUMBER:
01 All dimensions are in millimeters
02 Concrete = C15; Rebar = 410 N/mm2
03 Assumed Soil Bearing Capacity =62kPa
02
04 Drawings are not to scale
A A
100mm thick slab underneath tiles
03
04 Drawings are not to scale
6 Y10-01
@ 175 mm c/c
A A
100mm thick slab underneath tiles
6 Y10-01
@ 175 mm c/c
04
03 Assumed Soil bearing capacity = 62 kPa
04 Drawings are not to scale
6 Y10-01
@ 175 mm c/c
A A
100mm thick slab underneath tiles
6 Y10-01
@ 175 mm c/c
05
03 Assumed Soil bearing capacity = 62 kPa
04 Drawings are not to scale
11 Y12-01
@ 200 mm c/c T&B
Pad A Pad A
6 Y12-01
@ 180 mm c/c
Pad A Pad A
6 Y12-03
@ 180 mm c/c T&B
Pad A plan view (18 No.)
Pad B Pad B
Pad A Pad A Pad A Pad A Pad A Pad A
Pad B plan view (4 No.)
06
04 Drawings are not to scale
A A
07
03 Assumed Soil bearing capacity = 62 kPa
04 Drawings are not to scale
8 Y12-01
@ 200mm c/c
12 Y12-01
@ 200 mm c/c
Base Type D T&B
Base Type A
Y1
Base Type B Base Type B 8Y12-02
@ 200 mm c/c T&B
08
04 Drawings are not to scale
09
04 Drawings are not to scale
Section A - A
A
10
04 Drawings are not to scale
11
04 Drawings are not to scale
2
Allowable Bearing Capacity of Soil 62 kN/m
BASE DESIGN/SIZING
Ref Calculations Output
2
Concrete Grade = 15 N/mm
Total Ultimate load on base, N = 59 kN ( from superstructure) See load files (node 427)
2
Bearing capacity of soil = 62 kN/m
2
Required area of footing = 0.95 m
2
Area of base provided = 1m Area of pad provided
3 4
Moment of inertia of foundation , I= bd /12 = 0.083333 m
1.00 la = 0.95
The depths of pad foundation provided is deemed sufficient for punching shear
reistance. Where foundations overlap, a combined footing of equivalent area shall be
provided
BASE DESIGN/SIZING
Ref Calculations Output
2
Concrete Grade = 15 N/mm
Total Ultimate load on base, N = 22 kN ( from superstructure) See load files (node 221)
2
Bearing capacity of soil = 62 kN/m
2
Required area of footing = 0.35 m
2
Area of base provided = 1m Area of pad provided
3 4
Moment of inertia of foundation in the x -axis bd /12 = 0.083333 m
1.00 la = 0.95
The depths of pad foundation provided is deemed sufficient for punching shear
reistance. Where foundations overlap, a combined footing of equivalent area shall be
provided
BASE DESIGN/SIZING
Ref Calculations Output
2
Concrete Grade = 15 N/mm
Total Ultimate load on base, N = 16.5 kN ( from superstructure) See load files (Node 58)
2
Bearing capacity of soil = 62 kN/m
2
Required area of footing = 0.27 m
2
Area of base provided = 0.64 m Area of pad provided
3 4
Moment of inertia of foundation in the x -axis bd /12 = 0.034133 m
1.00 la = 0.95
The depths of pad foundation provided is deemed sufficient for punching shear
reistance. Where foundations overlap, a combined footing of equivalent area shall be
provided
BASE DESIGN
Ref Calculations Output
2
Concrete Grade = 15 N/mm
Total Ultimate load on base, N = 24 kN ( from superstructure) See load files (node 379)
2
Bearing capacity of soil = 62 kN/m
2
Required area of footing = 0.39 m
2
Area of base provided = 2.25 m Area of pad provided
3 4
Moment of inertia of foundation in the x -axis bd /12 = 0.421875 m
0.99 la = 0.95
The depths of pad foundation provided is deemed sufficient for punching shear
reistance. Where foundations overlap, a combined footing of equivalent area shall be
provided
BASE DESIGN
Ref Calculations Output
Base 5: Airconditioner Room -48.75m x 30.24m (inside warehouse, i.e. pad foundation
only)
2
Concrete Grade = 15 N/mm
Total Ultimate load on base, N = 14 kN ( from superstructure) See load files (Node 110)
2
Bearing capacity of soil = 62 kN/m
2
Required area of footing = 0.23 m
2
Area of base provided = 1m Area of pad provided
4
Moment of inertia of foundation in the x -axis bd3/12 = 0.083333 m
1.00 la = 0.95
The depths of pad foundation provided is deemed sufficient for punching shear
reistance. Where foundations overlap, a combined footing of equivalent area shall be
provided
BASE DESIGN
Ref Calculations Output
2
Concrete Grade = 15 N/mm
Total Ultimate load on base, N = 16 kN ( from superstructure) See load files (node 27)
2
Bearing capacity of soil = 62 kN/m
2
Required area of footing = 0.26 m
2
Area of base provided = 0.64 m Area of pad provided
3 4
Moment of inertia of foundation in the x -axis bd /12 = 0.034133 m
1.00 la = 0.95
The depths of pad foundation provided is deemed sufficient for punching shear
reistance. Where foundations overlap, a combined footing of equivalent area shall be
provided
BASE DESIGN
Ref Calculations Output
2
Concrete Grade = 15 N/mm
Total Ultimate load on base, N = 57 kN ( from superstructure) See load files (node 14)
2
Bearing capacity of soil = 90 kN/m
2
Required area of footing = 0.63 m
2
Area of base provided = 1m Area of pad provided
4
Moment of inertia of foundation in the x -axis bd3/12 = 0.083333 m
1.00 la = 0.95
The depths of pad foundation provided is deemed sufficient for punching shear
reistance. Where foundations overlap, a combined footing of equivalent area shall be
provided