3 MATERIALS
Matl. Modulus Modulus Poisson's Ratio Spec. Weight Coeff. of Th. Exp. Partial Factor Material
No. E [kN/cm2] G [kN/cm2] [-] [kN/m3] [1/°C] M [-] Model
1 Concrete f'c = 4000 psi | ACI 318-14
2485.56 1035.65 0.200 22.18 9.90E-06 1.00 Isotropic Linear
Elastic
2 Steel A992 | ANSI/AISC 360-16:2016
19994.80 7722.13 0.295 76.97 1.20E-05 1.00 Isotropic Linear
Elastic
3 Concrete C20/25 | EN 1992-1-1:2004/A1:2014
3000.00 1250.00 0.200 24.52 1.00E-05 1.00 Isotropic Linear
Elastic
4 Concrete C25/30 | DIN 1045-1:2008-08
2670.00 1112.50 0.200 24.52 1.00E-05 1.00 Isotropic Linear
Elastic
1.4 SURFACES
Surface Surface Type Matl. Thickness Area Weight
No. Geometry Stiffness Boundary Lines No. No. Type d [mm] A [m 2] W [kg]
36 Plane Standard 258,99,219,228,109,241, 4 Constant 200.0 53.792 26896.00
108,314,317,259,234,
240,214
37 Plane Standard 271,98,216,238,232,96, 4 Constant 200.0 53.792 26896.00
270,308,107,236,93,228,
219
38 Plane Standard 236,235,97,241,109,93 4 Constant 200.0 3.750 1875.00
39 Plane Standard 223,218,220,238 4 Constant 200.0 9.635 4817.50
40 Plane Standard 242,240,227,243,225,103 4 Constant 200.0 9.635 4817.50
reakcije
zidova
iznad 16.580
reakcije Reakcije
zidova stubišta
iznad 16.580 9.430
9.430
reakcije
zidova
iznad 2.00
reakcije 5.610 2.00
zidova 2.00
iznad 4.240
5.610 2.004.240
2.00
Reakcije
stubišta
Y
LC3: KORISNO
LC3 : Korisno Isometric
Loads [kN/m], [kN/m^2]
2.00
4.240 0.960
p-ZL 2.00 3.004.240
4.00 reakcije
zidova
reakcije
0.960 iznad
zidova Reakcije
iznad stubišta
LC4: SNIJEG
LC4 : Snijeg Isometric
Loads [kN/m], [kN/m^2]
p-ZL 1.00
reakcije 1.00
zidova
reakcije 1.600
iznad
zidova
p-ZL 1.00 iznad
1.600
1.00
Z
SUPPORT REACTIONS
RC1 : CO1 or CO2 Isometric
Support Reactions[kN/m]
Result Combinations: Max and Min Values
25.50 81.53
45.69 24.82
45.69
24.67
95.08
49.75
24.67 18.47 23.23
25.50 208.56 38.57
24.82 81.53 208.56
95.08 38.57
23.23
X
Z
Max p-z': 208.56, Min p-z': -81.53 kN/m
LOCAL DEFORMATIONS uz
Local Deformations RC2 : CO3 or CO6 In Z-direction
u-z [mm]
Result Combinations: Max and Min Values
5.9
5.1
4.3
3.4
2.6
1.7
0.9
0.0
-0.8
-1.6
Z X
-2.5
-3.3
Max : 6.0
Min : -3.4
3.196 m
Max u-z: 6.0, Min u-z: -3.4 mm
RF-CONCRETE Surfaces
with selection
Reinforced concrete design 1.1 GENERAL DATA
Design according to Standard: EN 1992-1-1:2004/A1:2014
Definition of Provided Additional Reinforcement Automatic arrangement according to the specifications in Table 1.4
DETAILS
Analysis Method for Reinforcement Envelope Mixed
Apply the internal forces without the rib components
1.2 MATERIALS
Material Material Description
No. Concrete Strength Class Steel Description Comment
4 Concrete C25/30 B 500 S (A)
REINFORCEMENT RATIO
Minimum secondary reinforcement 20.0 %
Basic minimum reinforcement 0.0 %
Minimum compression reinforcement 0.0 %
Minimum tension reinforcement 0.0 %
Maximum reinforcement percentage 4.0 %
Minimum shear reinforcement percentage 0.0 %
15.228
12.114
9.001
5.888
2.775
-0.339
-9.678
-12.792
0.008 0.008
Max :
Min :
21.454
-12.792
0.013 0.013
Y 0.008
-12.789 0.008
0.233
0.031 0.031
19.272
21.450 21.454
19.271
-1.579
-0.073
0.007 0.012 -0.024 -0.024 0.012 0.007
-0.073
L= 6680 mm
L/250 = 6680/250 = 26,72 mm > 21,454 mm
Zadovoljava!
RF-CONCRETE Surfaces
with selection
GSN 1.1 GENERAL DATA
Design according to Standard: EN 1992-1-1:2004/A1:2014
Definition of Provided Additional Reinforcement Automatic arrangement according to the specifications in Table 1.4
DETAILS
Analysis Method for Reinforcement Envelope Mixed
Apply the internal forces without the rib components
1.2 MATERIALS
Material Material Description
No. Concrete Strength Class Steel Description Comment
4 Concrete C25/30 B 500 S (A)
1.3 SURFACES
Surface Matl. Thickness Thickness
No. No. Type [mm] Notes Comment
36 4 Constant 200.00
37 4 Constant 200.00
38 4 Constant 200.00
39 4 Constant 200.00
40 4 Constant 200.00
REINFORCEMENT RATIO
Minimum secondary reinforcement 20.0 %
Basic minimum reinforcement 0.0 %
Minimum compression reinforcement 0.0 %
Minimum tension reinforcement 0.0 %
Maximum reinforcement percentage 4.0 %
Minimum shear reinforcement percentage 0.0 %
5.24
Z X
Max : 5.24
Min : 5.24
3.196 m
Max a-s,1,-z (top): 5.24, Min a-s,1,-z (top): 5.24 cm2/m
DODATNA ARMATURA As,1,-z (top)
Req. Additional RF-CONCRETE Surfaces CA2 In Z-direction
Reinforcement
a-s,1,-z (top) [cm2 /m] GSN
8.73
Values: a-s,1,-z (top) [cm^2/m]
7.94
7.15
6.35
5.56
4.76
3.97
3.18
2.38
1.59
Z X
0.79
0.00
150 cm 150 cm
Max :
Min :
8.73
0.00 200 cm 200 cm
Y 3.12 3.12
8.73 8.73
200 cm
200 cm
φ12/15 φ12/15
2.32 2.32
φ8/15 φ8/15
3.196 m
Max a-s,1,-z (top): 8.73, Min a-s,1,-z (top): 0.00 cm2/m
0.61
0.54
0.48
0.41
0.34
0.27
0.20
0.14
Z X
0.07
0.00
Max : 0.75
Min : 0.00
Y
0.75 0.75
3.196 m
Max a-s,2,-z (top): 0.75, Min a-s,2,-z (top): 0.00 cm2/m
DODATNA ARMATURA As,1,+z (bottom)
Req. Additional RF-CONCRETE Surfaces CA2 In Z-direction
Reinforcement
a-s,1,+z (bottom) GSN
[cm 2 /m]
2.81
Values: a-s,1,+z (bottom) [cm^2/m]
2.56
2.30
2.04
1.79
1.53
1.28
1.02
0.77
0.51
Z X
0.26 290 cm 290 cm
0.00
Max : 2.81
Min : 0.00
Y 2.81φ8/15 2.81
648 cm
648 cm
φ8/15
1.93 1.93
2.13 2.13
0.18 0.18
3.196 m
Max a-s,1,+z (bottom): 2.81, Min a-s,1,+z (bottom): 0.00 cm2/m
1.50
1.33
1.16
1.00
0.83
0.66
0.50
200 cm 200 cm
0.33
Z X
0.17
300 cm
300 cm
Y φ8/30 φ8/30
4 φ8/30 4 φ8/30
200 cm
1.83 1.83
0.18 0.18
0.74 0.74
pokriveno sa
armaturom u rubu
ploče min 2φ12
3.196 m
Max a-s,2,+z (bottom): 1.83, Min a-s,2,+z (bottom): 0.00 cm2/m
Pozicija: Dü1UG-G/9 Dokaz proboja PB 1
1. Određivanje opterećenja
A= 3,02 m2
Opterećenja
Vlastita težina ploče 5 kN/m 2
Dodatno stalno 2 kN/m 2
Korisno opterećenje 3 kN/m 2
3. Ulazni podaci
Geometrija:
Debljina ploče: h= ............................... 20,0 cm
Zaštitni sloj betona: cnom = ............................... 2,50 cm
Zid: d= ............................... 20,0 cm
Armatura ploče:
Durchmesser: Abstand: Achsabstand zum Rand:
Node 69,71
1.2.2 SURFACES
Surface Material Thickness Thickness Comment
No. No. Type [mm]
36 4 Constant 200.0
37 4 Constant 200.0
38 4 Constant 200.0
RC1
For Design Shear Resistance
Required Ratio of Longitudinal Reinforcement 0.003
Reinf. Ratio of 1st Layer 1 0.003
Required Longitudinal Reinforcement req as,1 5.24 cm2/m
Effective Depth 1st Layer d1 16.00 cm
Reinf. Ratio of 2nd Layer 2 0.003
Required Longitudinal Reinforcement req as,2 5.24 cm2/m
Effective Depth 2nd Layer d2 15.00 cm
Maximum Allowed Ratio of Reinforcement max 0.020
Req. Reinforcement req as 5.24 cm2/m
Req. Length of Reinforcement lr 0.853 m
Req. Width of Reinforcement lr 1.163 m
Defined Longitudinal Reinforcement
Width of Reinforcement b1,t 1.16 m
Defined Longitudinal Reinforcement prov as,1,t 5.24 cm2/m
RC1
For Design Shear Resistance
Required Ratio of Longitudinal Reinforcement 0.003
Reinf. Ratio of 1st Layer 1 0.003
Required Longitudinal Reinforcement req as,1 5.24 cm2/m
Effective Depth 1st Layer d1 16.00 cm
Reinf. Ratio of 2nd Layer 2 0.003
Required Longitudinal Reinforcement req as,2 5.24 cm2/m
Effective Depth 2nd Layer d2 15.00 cm
Maximum Allowed Ratio of Reinforcement max 0.020
Req. Reinforcement req as 5.24 cm2/m
Req. Length of Reinforcement lr 0.853 m
Req. Width of Reinforcement lr 1.163 m
Defined Longitudinal Reinforcement
Width of Reinforcement b1,t 1.16 m
Defined Longitudinal Reinforcement prov as,1,t 5.24 cm2/m
Primary Load
RF-PUNCH Pro CA1 Isometric
Punching Load
Primary Load [kN]
50.00
Max : 50.00
Min : 50.00
50.00 kN
50.00 kN
5.24
Z X
Max : 5.24
Min : 5.24
Y
3.196 m
Max a-s,2,Top: 5.24, Min a-s,2,Top: 5.24 cm2/m
as,1,Bottom
RF-PUNCH Pro CA1 In Z-direction
Longitudinal
Reinforcement
a-s,1,Bottom [cm 2 /m]
5.24
Z X
Max : 5.24
Min : 5.24
Y
3.196 m
Max a-s,1,Bottom: 5.24, Min a-s,1,Bottom: 5.24 cm2/m
as,2,Bottom
RF-PUNCH Pro CA1 In Z-direction
Longitudinal
Reinforcement
a-s,2,Bottom [cm 2 /m]
5.24
Z X
Max : 5.24
Min : 5.24
Y
3.196 m
Max a-s,2,Bottom: 5.24, Min a-s,2,Bottom: 5.24 cm2/m
as,w
RF-PUNCH Pro CA1 In Z-direction
Punching Shear
Reinforcement
a-s,w [cm 2 ]
0.00
Z X
Max : 0.00
Min : 0.00
Y
3.196 m
Max a-s,w: 0.00, Min a-s,w: 0.00 cm2
vEd
RF-PUNCH Pro CA1 In Z-direction
Design Shear Force
v-Ed [kN/m 2 ]
407
Z X
Max : 407
Min : 407
3.196 m
Max v-Ed: 407, Min v-Ed: 407 kN/m2
vEd / vRd,c
RF-PUNCH Pro CA1 In Z-direction
Design Ratio
v-Ed/v-Rd,c
0.822
Z X
Max : 0.822
Min : 0.822
3.196 m
Max v-Ed/v-Rd,c: 0.822, Min v-Ed/v-Rd,c: 0.822