You are on page 1of 1

AREA CHART :

TO HARAPANAHALLI
Certificate
(1) The mulba during the construction will be removed on weekly TOTAL AREA OF PLOT 1.35=ACRE = 5463.256 SQM
basis.If the same is not done, in that case the local body shall
TO HARAPANAHALLI 12M WIDE ROAD TOTAL COVD. AREA OF PETROL PUMP = 2401.519 SQM
remove the mulba and the cost shall be borne by
TO HOSPET the owner of the plot. TOTAL COVD. AREA OF HOTEL = 1776.069 SQM
12M WIDE ROAD C/L OF THE ROAD (2) During construction it is mandatory on the part of the owner to

TO HOTEL
PARKING AREA PROVIDED IN PETROL PUMP = 117.288 SQM
TO HOSPET P.W.D. BOUNDARY LINE
properly screen the construction site off the main road by means
EXIT ENTRY
CD 0.60M WIDE HUME PIPE CD
C/L OF THE ROAD of erecting a screen wall not less than 8 ft. in height from ground AREA OF THE BUILDING IN PETROL PUMP = 74.23 SQM
TO HOTEL

LP
RAIN WATER HARVESTING
BEFFER STRIP RAIN WATER HARVESTING LP level which is to be painted to avoid unpleasant look from road

SITE BOUNDRY
RECHARGE PIT RECHARGE PIT
CD
EXIT P.W.D. BOUNDARY LINE
0.60M WIDE HUME PIPE
ENTRY
CD 230MM THIK.& 300M
side .In addition to this, a net or some other protective material
AREA PROVIDED FOR PARK IN HOTEL = 130.89 SQM
HIGH KERB WALL LP

LP RAIN WATER HARVESTING RAIN WATER HARVESTING LP shall be hoisted at the facades of the building to ensure that any AREA PROVIDED FOR PARKING FACILITY IN HOTEL = 166.88 SQM
SITE BOUNDRY

RECHARGE PIT BEFFER STRIP RECHARGE PIT


230MM THIK.& 300M
HIGH KERB WALL LP
falling material remains within the protected area.
LP
PROPOSED HOTEL AREA = 667.2 SQM
(3) Noise related activities will not be taken up for construction at

PARKING
SITE BOUNDRY
night after 10pm PROPOSED ROAD AREA FOR HOTEL = 129.18 SQM
LP 230MM THICK.AND 1800MM.HIGH
BOUNDARY WALL (OUT SIDE)
PARKING
SITE BOUNDRY

LP GL GL Water Harvesting Certificate SITE DETAILS :

PARKING
230MM THICK.AND 1800MM.HIGH
BOUNDARY WALL (OUT SIDE) (1) Certified that the building plans submitted for approval satisfy
LP FRONT ELEVATION OF HOTEL
the water
PARKING

7M WIDE ROAD
harvesting requirements as well as minimum anticipated SURVEY NUMBER = 14*
LP
discharge of waste

PARKING PARKING
water as stipulated under clause 22.4.1,22.4.2 and the HISSA = B3
MS MS LP
information given the rain is factually correct to the best of our KHATA NUMBER = 1598
PARKING PARKING
7M WIDE ROAD

CANOPY STEEL STRUCTURE LP


knowledge and understanding. OWNER NAME = P SASIKANTA bin PATAGI VENKATESH
WITH P.V.C CLADDING (2) waste water recycling system shall be incorporated at site .
V F MS HSD LP
The recycled Water shall be used for horticulture purposes
CHAKKUBANDI
20KL MS TANK SP
Structural stability Certificate

PARKING
D S LP
BW PARAPET
SP
ROOF SLAB (1) Certified that the building plans submitted for approval satisfy NORTH = SURVEY NO 14/B3
PARKING

LP
BW HSD HSD the safety requirements as stipulated under clause 18 of building SOUTH = MUJAVAR REHEMAN SAB'S LAND

SITE BOUNDRY
bye-law, 1983 and the information given therein is factually EAST
LP
= 12M WIDE ROAD
SITE BOUNDRY

CNG
COMPRESSOR FIRE
EXITINGUISHERS GATE
RCC LINTEL correct to the best of our knowledge and understanding.
WEST = KOTRAPPA'S LAND

EXITINGUISHERS
3M WIDE
SITE BOUNDRY

LP (2) It is also Certified that the structural design including safety from

FIRE
SITE BOUNDRY

27.62

LP
GATE
LP 0.23mThk natural hazards based on soil.conditions has been duly
EXITINGUISHERS

3M WIDE
BBM WALL
1800MM HIGH CHAINLINK incorporated in the design of the building and these provision SCALE
FIRE

FANCING OVER 300MM HIGH


LCV PLAT FORM

KERB WALL
LP
shall be adhered to during the construction.
1:2 WERE 1m=2m
9.28 OFFICE FLOORING
40X75 LTRS. W.C.
CNG CASCADE
OVER CNG COMPRESSOR OFFICE
5.55X5.96
MGR.ROOM
NOTE
ENTERANCE

18.57 230MM THICK.AND 1800MM.HIGH


BOUNDARY WALL (OUT SIDE) GL GL
MGR.ROOM SSM IN CM
ENTERANCE

5.55X5.43 230MM THICK.AND 1800MM.HIGH


BOUNDARY WALL (OUT SIDE) ALL DIMENSIONS ARE IN METERS UNLESS SPECIFIED
CNG
PANEL ROOM TOILETS SAND & BOULDERS
ENTERANCE FILLING
CNG TOI. TOI. TOI.
PANEL ROOM
ENTERANCE PARK SECTION OF HOTEL AT B-B OWNER'S SIGNATURE/SEAL
24.38

ROAD BOUNDARY PARK DISPENSER


PARKING 1 1 2
28.17

PARKING

HP CANOPY STEEL STRUCTURE WITH P.V.C CLADDING


ENTERANCE
33.88

ENTERANCE
GUARD
ROOM UTILITY
CASH COUNTER

KITCHEN 1 1

1 2
ENGINEER'S SIGNATURE/SEAL
230MM THIK. AND 1220M. HIGH
SITE BOUNDRY

B.M BOUNDARY WALL FUEL DISPENSER FUEL DISPENSER


230MM THIK. AND 1220M. HIGH
B.M BOUNDARY WALL
FRONT VIEW SIDE VIEW
SITE BOUNDRY

SAND
SITE BOUNDRY

45.71

HOTEL
SITE BOUNDRY

HOTEL
FRONT ELEVATION
M P
M P

6.09
6.09 TOILETS
5.91
TOILET TOILET TOILET TOILET TOILET
1.52X1.52 1.52X1.52 1.52X1.52 1.52X1.52 1.52X1.52

46.44
SITE BOUNDRY TOP VIEW OF FUEL
SITE BOUNDRY TOP VIEW OF LAYOUT PLAN DISPENSER
LAYOUT PLAN OF PETROL PUMP AND HOTEL
TITLE :
SUBMISSION DRAWING
HP CANOPY STEEL STRUCTURE WITH P.V.C CLADDING
DATE : E

PARAPET SCALE :1:100 N S


COLUMN COLUMN COLUMN
ROOF SLAB
ARCHITECTS : W
RCC LINTEL
KS CONSTRUCTIONS
0.23mThk
BBM WALL Kotturu-Hospet Bypass Road
DRIVEWAY LVL+00 FLOORING FIRE EXTINGUISHER HARAPANAHALLI (T)
SSM IN CM
VIJAYANAGARA (D)
GL GL
Ph no. 9740910241
SECTIONAL ELEVATION OF PETROL PUMP AT B-B 7760204907
SAND & BOULDERS 9538697473
FILLING