You are on page 1of 6

PAUT INSPECTION REPORT

CLIENT : SEMBCORP MARINE INTEGRATED YARD PTE LTD RFI No. : N.A.
PROJECT NAME : JOHAN CASTBERG REPORT NO : MSE-SCM-JC-PAUT-HS-017A
PROJECT NO : 09J110006 ACCEPTANCE STD : BS EN ISO 19285:2016 (AL-3)
PROCEDURE NO. : C143-SC-A-KA-0013 Rev:00 REFERENCE STD. : BSEN ISO 13588: 2012
DRAWING TITLE : N.A. WELD MAP NO : H400-231-002-04
MATERIAL GRADE : Carbon Steel TYPE OF WELD : Butt Weld
DIRECTION (Long/Trans) : Transverse TESTED DATE : 01-06-2021
DIMENSIONS : Refer Annex LOCATION OF TEST : DD2
PAUT INSTRUMENT : OMNISCAN X3 SEARCH UNIT :
MAKE : RD TECH /OLYMPUS PROBE SERIAL NO : A32-U5544
MODEL : OMNISCAN-X3(PA32:128PR) MAKE : OLYMPUS
SERIAL NO. : QC-0075232 MODEL : A32
CAL DUE DATE : 17-Dec-2021 FREQUENCY : 5MHz
EQUIPMENT S/W VERSION : PA32:128PR CABLE TYPE & LENGTH : EZ LATCH TECHNOLOGY & 2.5 METER
ANALYSIS SOFTWARE : OMNI SCAN PC TOOLKIT NO. OF ELEMENTS : 64
SOFTWARE VERSION : 5.5.1 ELEMENTS PITCH : 0.5
FINAL PROCESSING DISPLAY : N.A. ELEMENT SIZE : 10mm
CALIBRATION SETUP CALIBRATION BLOCK
GROUPS : 01 02 03 CAL BLOCK NUMBER : MSE-ISO-PAUT-CAL-001
TYPE : Sectorial Linear (UBVL) Linear (BBVL) MATERIAL : Carbon steel
ANGLE RANGE : 40° ~ 72° 59° 66° REFLECTOR DETAILS : SDH (¼, & ½,)
FOCAL LAW : EQ-24, FE-38 &LE-16 EQ-26, FE-1, & LE-64 EQ-16, FE-32, &LE-64 THICKNESS : 20 MM
FOCAL DEPTH : 6 16 3 BLOCK TEMPERATURE : AMBIENT
GAIN : 16.2.0 dB 18.0 dB 24.0 dB SURFACE CONDITION : Coated
Has been done with manual UT using 60º
SCANNING SENSITIVITY (dB) : +6dB +6dB +6dB TRANSFER CORRECTION :
Probe, Transverse Correction dB (+7.0)
Note: EQ-Element Quantity, FE-First Element, LE-Last Element, UBVL-Upper Bevel Volume, BBVL-Bottom Bevel Volume.
SCAN DETAILS WEDGE DETAILS
SCAN PLAN ID : Annexure: A1-1 WEDGE MODEL : SA32-N55S-IHC
SCANNER : MINI WHEEL ENCODER & HSMT Scanner WEDGE ANGLE : 36.1°
ENCODER : 12 steps/mm WEDGE MATERIAL : PERSPEX
TECHNIQUE : Manual Scanning & Semi-automated RESOLUTION : 1MM
SEARCH UNIT TRAVEL SPEED : Not Exceed 150mm/sec DATA SAMPLING : 1MM
Brand : Olympus STATE : N.A.
EVALUATION & RESULT SUMMARY
Depth (mm) Maximum Height (mm)
Un-coated (PAUT)

Un-coated (PAUT)

Skew (90º / 270º)


Axial Offset (mm)
Un-coated (TFM)

Un-coated (TFM)
Distance from 0
Thickness(mm)

I Indication. No.

Coated (PAUT)

Coated (PAUT)

Amplitude (%)
Segment(mm)

Accept/Reject
J Joint Number

Coated (TFM)

Coated (TFM)
Length (mm)

Flaw Type

Remarks
Refer Annexure-1 & 2
SCAN PLAN NO: A1-1

L.DILEEP KUMAR S. THIRUVENKADAM


PCN LEVEL 2 (PAUT) PCN LEVEL 3 (PAUT)

PREPARED BY REVIEWED BY REVIEWED BY APPROVED


PAUT OPERATOR NDE LEVEL 3 SMIY QA/QC OWNER REPRESENTATIVE SURVEYOR

REPORT NO: MSE-SCM-JC-PAUT-HS-017A Page 1 of 6


PAUT INSPECTION REPORT
ANNEXURE-1: (Acceptable & Recordable Indications)
EVALUATION & RESULT SUMMARY
Depth (mm) Maximum Height (mm)

Group (Sec/Lin1/Lin2)
r respect to Reference.
Indication (dB) with
Un-coated (PAUT)

Un-coated (PAUT)

Skew (90º / 270º)


Axial Offset (mm)
Un-coated (TFM)

Un-coated (TFM)
Distance from 0
Thickness(mm)

UT Report. No.
I Indication. No.

Coated (PAUT)

Coated (PAUT)
Joint Number

Segment(mm)

Accept/Reject
Coated (TFM)

Coated (TFM)
Length (mm)

Flaw Type

Remarks

Location
01 63 206 - 2.6-7.2 - - - 4.6 - - -7 2 V (SI) 90 Sec Int.,
0-300 SP1
- - - - - - - - - - - - - - 270 Sec -

- - - - - - - - - - - - - - 90 Sec -
0-300 SP2
- - - - - - - - - - - - - - 270 Sec -

RSU-EXT-1156,09/03/2021
Refer Attachment-1
0-1400SP3 01 372 515 - 1.6-6.5 - - - 4.9 - - -6.3 0 V (SI) Sec 90

SCM-JC-UT-1447
AP4-B14-1

- - - - - - - - - - - - - - 90 Sec -
12

***
0-1000 SP4
- - - - - - - - - - - - - - 270 Sec -

- - - - - - - - - - - - - - 90 Sec -
0-1000 SP5
01 894 9 - 7.6-10.6 - - - 3 - - -5 -2 V (SI) 270 Sec -

0-300 SP6 - - - - - - - - - - - - - - 270 Sec -

0-300 SP7 - - - - - - - - - - - - - - 270 Sec -

0-300 SP8 - - - - - - - - - - - - - - 90 Sec -


0-300 SP8 - - - - - - - - - - - - - - 90 Sec -
- -
- - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -

ACC: Acceptable, REJ: Reject, P-Planar, V-Volumetric SI – Slag Inclusion, Por – Porosity, LOF – Lack of Fusion, LOSWF – Lack of Sidewall Fusion, LOP – Lack of Penetration, CR-Crack, LORF –
Legends
Lack of Root Fusion, Int.-Intermittent, N.A.- Not Applicable, SP-Spot.

Note: 1. Evaluation Level H0-10 dB and above.


2. Recording levels are 4dB below the corresponding acceptance level.
*** PAUT Carried out to find the height sizing. Hence accept / Reject not reported.
REPORT NO: MSE-SCM-JC-PAUT-HS-017A Page 2 of 6
PAUT INSPECTION REPORT
ANNEXURE-2: (Height Sizing Assessment)
EVALUATION & RESULT SUMMARY
Depth (mm) Maximum Height (mm)

Group (Sec/Lin1/Lin2)
r respect to Reference.
Indication (dB) with
Un-coated (PAUT)

Un-coated (PAUT)

Skew (90º / 270º)


Axial Offset (mm)
Un-coated (TFM)

Un-coated (TFM)
Distance from 0
Thickness(mm)

UT Report. No.
I Indication. No.

Coated (PAUT)

Coated (PAUT)
Joint Number

Segment(mm)

Accept/Reject
Coated (TFM)

Coated (TFM)
Length (mm)

Flaw Type

Remarks

Location
0-1400SP3 01 777 86 - 8.4-12 - - - 3.6 - - +2 2 P (LORF) Sec 270 Int.,
AP4-B14-1

Refer Attachment-1

1156,09/03/2021
SCM-JC-UT-1447
12 0-300SP6 01 42 125 - 9.3-11.8 - - - 2.5 - - -2 1 P (LORF) Sec 90 *** Int.,

RSU-EXT-
0-300 SP7 01 212 85 - 8.4-10.1 - - - 1.7 - - -2 -2 P (LORF) Sec 90 Int.,
- - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - -
- - -
- - - - - - - - - - - - - - - - - - - -

- -
- - - - - - - - - - - - - - - - - - - - -

- -
- - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - -
ACC: Acceptable, REJ: Reject, P-Planar, V-Volumetric SI – Slag Inclusion, Por – Porosity, LOF – Lack of Fusion, LOSWF – Lack of Sidewall Fusion, LOP – Lack of Penetration, CR-Crack, LORF –
Legends
Lack of Root Fusion, Int.-Intermittent, N.A.- Not Applicable, SP-Spot.
Note: 1. Evaluation Level H0-10 dB and above.
2. Recording levels are 4dB below the corresponding acceptance level.
*** PAUT Carried out to find the height sizing. Hence accept / Reject not reported.

REPORT NO: MSE-SCM-JC-PAUT-HS-017A Page 3 of 6


PAUT INSPECTION REPORT
Segment-B14-01(0-300SP1) SKEW-90º Segment-B14-01(0-300SP1) SKEW-270º

Segment-B14-01(0-300SP2) SKEW-90º Segment-B14-01(0-300SP2) SKEW-90º

Segment-B14-01(0-1400SP3) SKEW-90º Segment-B14-01(0-1400SP3) SKEW-90º

Segment-B14-01(0-1000SP4) SKEW-90º Segment-B14-01(0-1000SP4) SKEW-270º

REPORT NO: MSE-SCM-JC-PAUT-HS-017A Page 4 of 6


PAUT INSPECTION REPORT
Segment-B14-01(0-1000 SP5) SKEW-90º Segment-B14-01(0-1000 SP5) SKEW-270º

Segment-B14-01(0-300 SP6) SKEW-90º Segment-B14-01(0-300 SP6) SKEW-270º

Segment-B14-01(0-300 SP7) SKEW-90º Segment-B14-01(0-300 SP7) SKEW-270º

Segment-B14-01(0-300 SP8) SKEW-90º Segment-B14-01(0-300 SP8) SKEW-270º

REPORT NO: MSE-SCM-JC-PAUT-HS-017A Page 5 of 6


PAUT INSPECTION REPORT
Attachment-1

REPORT NO: MSE-SCM-JC-PAUT-HS-017A Page 6 of 6