You are on page 1of 1

NEXUS INSPECTORATE PHASED ARRAY EXAMINATION REPORT

PRIVATE LIMITED Procedure No.:Sauni L4AP8/JSIW/PAUT/001REV 01 Report No.: NEXUS-PAUT-L4AP80030 Date : 15-02-2020

Project Name: Sauni Yojna L-4A Package-8 ON/Drawing No.: NWR/JSIW/L4AP8/OFR/03 Calibration Block : V1 & PAUT Reference Block
(TCG)

Client Name: JSIW Infrastucture Pvt. Ltd. Flaw Detector: Olympus make OmniSX-PA16:64P Software Weld JointType : Single V
Version : MXU4.4R5
Acceptance Standard: Materials: M.S Sound Velocity : 3240 M/S
API 1104 Latest Edi.CL9.0
Surface Condition: As Brushed WPS No.:
NWRWS&KD/Sauni/L4AP8/WPS01 Rev00
Type PA
Frequency (MHz) 5MHZ
Skew Angle 90/270 Degree
Probe Model 5L32-32X10-A32-P-5-OM Scanning dB 16.17

Wedge Model 65 Couplant Water


Equipment Serial No. Calibration QC-035739
Probe Aparture (MM) 16mm
due date 13/09/2020

Indication Details (MM)


Sr. Spool No. Joint No Segment Length(MM) Result Remarks
Location Length Depth Height Type
01 1318 OD X 09 MM KM07 SD 80 A1 210 179-181 1.91 -
80 A2 210 159-163 2.25 -
02 1318 OD X 09 MM Km07 SD 81 A1 210 138-142 2.65 -
81 A2 210 89-95 4.5 3.04
03 1318 OD X 09 MM Km07 SD 82 A1 210 82-87 3.88 3.8
82 A2 210 130-136 5.11 3.3
04 1318 OD X 09 MM Km07 SD 83 A1 210 63-68 3.76 3.3
83 A2 210 62-65 2.38 2.79
ACC Accepted REJ Repair NSD Non Significant Defect
ABBREVIATION CP Cluster Porosity P Porosity C Crack
PL Planar Defect CL Cylindrical Defect

NEXUS INSPECTORATE PRIVATE LIMITED SGS INDIA PVT LTD CLIENT


Reported By: Checked By: Checked By:

AMIR KHAN ACHYUT BHATT


ASNT PAUT LEVEL II PAUT Level II
(NEXUS/NDT/PAUT-201901 REV-00 ) (PAUT-II/10-19/012)
Signature: Signature: Signature: