Professional Documents
Culture Documents
Rev:0A
Project Number: PL212533 Project Name: FLOATING ROOF ABOVE GROUND STORAGE TANK NUMBER #7
Vendor: HAROUGE OIL COMPANY CODE: API 650 Ed.2010
Sub Vendor: SOCOMENIN JOB N° / OF : PL212533
3.1 Geotechnical Survey API 650, Spec. Spec Civil Work Procedure Inspection report W
H
3.2 Topographic Survey API 650, Spec. Spec Civil Work Procedure Inspection report H W
Contractual document Inspection report
3.3 Excavation ring beam- Checking Depth of Excavation Drawings, Engineering (checking depth of H W
Drawings excavation report)
Checking Elevation of Contractual document Inspection report
Structure Drawings, Engineering (checking level
Drawings H W
of structure)
Submission of Design for Checking the formwork ACI specifications for formwork
3.6 Formwork including shuttering with the sketched details design ACI standard H R
and props
Rebar check dia, bending,
concrete cover, lap joint/ API 650
Inspection Request H W
Length, space quality ,
fixing status, top elevation
Contractual document Inspection report
Checking Level of
Drawing (Checking level of H W
Structure
structure).
Check cathodic protection
hole on ring wall is Inspection Request W
available.
Checking cover, position Contractual document
and verticality of the Drawing & BS 5975 Inspection Request H W
formwork and top
elevation
Concrete grade inspection Contractual document
(Mixing, Transportation, Drawing & BS 8110 Inspection Request H W
Placing, Compaction and
3.7 Casting Ring Beam Curing)
ASTM C143 / BS 1881 Test report
Slump Test Record H W
(slump test record)
Construction joint
between footing and ring
Inspection Request H W
beam, cleanliness and
sound connection
Contractual document Test report
Cube Test Record H W
BS 1881 (Cube test record)
Curing – covers by blanks Contractual document
and water sprayed Inspection Request H W
H: Hold Point = Hold on the production till TPI /client Inspector performs inspection and supervise the required test
W: Witness Point = Manufacturer shall notify client and TPI Inspector but there is no hold on the production; Client can waive this inspection based on his discretion
A: Approval
R: Review of Contractors Documentati on
MR: Meeting Report