1 Features
1 - 1 EHYHBX-AV3

Hybrid technology combining gas and air to water heat pump for cooling, heating and hot water

1 ›› Daikin Altherma hybrid heat pump combines air-to-water heat ›› Low investment cost: no need to replace the existing radiators (up
pump technology with gas condensing technology to 80°C) and pipe work
›› Heating and cooling wall mounted indoor unit of air-to-water heat ›› Provides sufficient heat in renovation applications as all heat loads
pump are covered up to 32kW
›› Depending on outdoor temperature, energy prices and internal ›› Easy and fast installation thanks to the compact dimensions and
heat load, Daikin Altherma hybrid heat pump always selects the quick interconnections
most economical mode to operate

4 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

1 Features
1 - 2 EHYHBH-AV32

Hybrid technology combining gas and air to water heat pump for heating and hot water

›› Daikin Altherma hybrid heat pump combines air-to-water heat ›› Low investment cost: no need to replace the existing radiators (up 1
pump technology with gas condensing technology to 80°C) and pipe work
›› Heating only wall mounted indoor unit of air-to-water heat pump ›› Provides sufficient heat in renovation applications as all heat loads
›› Depending on outdoor temperature, energy prices and internal are covered up to 32kW
heat load, Daikin Altherma hybrid heat pump always selects the ›› Easy and fast installation thanks to the compact dimensions and
most economical mode to operate quick interconnections

EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 5


Daikin Altherma hybrid heat pump

1 Features
1 - 3 EHYKOMB-AA2, EHYKOMB-AA3

Hybrid technology combining gas and air to water heat pump for heating and hot water

1 ›› Daikin Altherma hybrid heat pump combines air-to-water heat ›› Low investment cost: no need to replace the existing radiators (up
pump technology with gas condensing technology to 80°C) and pipe work
›› Wall mounted gas module ›› Provides sufficient heat in renovation applications as all heat loads
›› Depending on outdoor temperature, energy prices and internal are covered up to 32kW
heat load, Daikin Altherma hybrid heat pump always selects the ›› Easy and fast installation thanks to the compact dimensions and
most economical mode to operate quick interconnections

6 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

2 Specifications
1 - 3 EHYKOMB-AA2, EHYKOMB-AA3

Technical specifications EHYKOMB33AA2
CE approval number CE-0063BT3576
Gas Device category C13 / C33 / C43 / C53 / C63 / C83 / C93 / B23 / B33 / C13x / C33x / C43x / C53x / C63x / C83x / C93x
Supply Belgium
pressure Bulgaria
G20 (20 mbar) / G25 (25 mbar)
G20 (20 mbar) / G31 (37 mbar)
2
Czech Republic G20 (20 mbar) / G31 (37 mbar)
Denmark G20 (20 mbar) / G31 (30 mbar)
France G20 (20 mbar) / G25 (25 mbar) / G31 (37 mbar)
Germany G20 (20 mbar) / G25 (20 mbar) / G31 (37 mbar)
Greece G20 (20 mbar) / G31 (37 mbar)
Hungaria G20 (20 mbar) / G31 (50 mbar)
Ireland G20 (20 mbar) / G31 (37 mbar)
Italy G20 (20 mbar) / G31 (37 mbar)
Malta G20 (20 mbar)
Poland G20 (20 mbar) / G31 (37 mbar)
Portugal G20 (20 mbar) / G31 (37 mbar)
Slovakia G20 (20 mbar) / G31 (50 mbar)
Slovenia G20 (20 mbar) / G31 (37 mbar)
Spain G20 (20 mbar) / G31 (37 mbar)
Switzerland G20 (20 mbar)
United Kingdom G20 (20 mbar) / G31 (37 mbar)
Category Belgium I2E(S)
Bulgaria II2H3P
Czech Republic II2H3P
Denmark II2H3P
France II2EsI3P
Germany II2ELL3P
Greece II2H3P
Hungaria II2H3P
Ireland II2H3P
Italy II2H3P
Malta I2H
Poland II2E3P
Portugal II2H3P
United Kingdom II2H3P
Connection Diameter mm 15
Consumption Min m³/h 0.79
(G20)
Gas Consumption Max m³/h 3.39
(G20)
Consumption Min m³/h 0.89
(G25) Max m³/h 3.92
Consumption Min m³/h 0.30
(G31) Max m³/h 1.29
NOx class 6
NOx level (G20) mg/ 36
kWh
Central heating Heat input Qn Nom Min kW 7.6
(net calorific Max kW 32.7
value)
Heat input Qn Nom Min kW 8.4
(gross calorific Max kW 36.3
value)
Output Pn Nom kW 32.0
at 80/60°C
Output at Nom kW 8.3
37/30°C
Factory Output Nom kW 32
setting
Setting Output Nom kW 8.3-32.0
range
Water pressure Max bar 3
(PMS)
Water Max °C 90
temperature
Efficiency Net calorific value % 98
full load Gross calorific value % 88
heat input
Efficiency Net calorific value % 109
part load Gross calorific value % 98
30% Qa
Operation Min °C 30
range Max °C 90

EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 7


Daikin Altherma hybrid heat pump

2 Specifications
1 - 3 EHYKOMB-AA2, EHYKOMB-AA3

Technical specifications EHYKOMB33AA2
Domestic hot Heat input (net Nom Min kW 7.6
water calorific value) Max kW 32.7
2 Qnw
Heat input (gross Nom Min kW 8.4
calorific value) Max kW 36.3
Qnw
Comfort class (EN13203) XL
Domestic hot water threshold l/min 2.0
Water Flow rate D Max l/min 15.0
flow (EN13203)
Temperature Max °C 65
Factory setting °C 60
Operation Min °C 40
range Max °C 65
Heat losses Heat loss thermal downtime losses EN 15502-1 38
Supply air Concentric 60/100
Flue gas Temperature Max °C 70
Flue gas Connection mm 60
Length 2x Max m 100
DN80
Length Max m 10
DN60/100
Length Max m 29
DN80/125
Mass flow Max kg/h 15.1
(G20)
Mass flow Max kg/h 15.1
(G25)
Mass flow Max kg/h 14.9
(G31)
Available overpressure Pa 75.0
Condensate drain hose DN 25.0
Mounting Wall
Casing Colour RAL9010
Material Steel
Dimensions Unit Height Casing mm 710
Width mm 450
Depth mm 240
Packed Height mm 900
unit Width mm 500
Depth mm 300
Weight Unit Empty kg 36
Packed Empty kg 38
unit
Packing Material Carton
Weight kg 2
Boiler Water volume l 4.0
Heat exchanger Quantity 1
Body material Aluminium
3-way valve Type None
Fan motor Type DC motor
Gas valve Type Siemens VGU76S.C0584
Water circuit - Piping connections diameter mm 22
Central heating Piping material Cu
Pressure Heating Max. bar 3
Air purge valve Yes (Manually)
Drain valve / fill valve No
flowswitch No
Manometer Digital
Sound power level Nom. dBA 50
Piping connections Water inlet heat exchanger diameter mm 22
Piping connections Water outlet heat exchanger diameter mm 22

8 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

2 Specifications
1 - 3 EHYKOMB-AA2, EHYKOMB-AA3

Technical specifications EHYKOMB33AA2
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manufacturer Name or trademark Daikin Europe N.V.
details
Product
description
Model identifier
Condensing boiler
EHYKOMB33AA2
Yes
2
Low-temperature boiler No
B1 boiler No
Cogeneration space heater No
Combination heater Yes
Combination heater is able to work No
only during off-peak hours
LW(A) Sound Indoor dB(A) 50
power level
Domestic hot General Declared load profile XL
water heating Qelec (Daily electricity kWh 0.071
consumption)
ηwh (water heating % 84
efficiency)
Qfuel (Daily fuel kWh 22.573
consumption)
Water heating energy efficiency A
class
AEC (Annual electricity kWh 16
consumption)
AFC (Annual fuel Gj 18
consumption)
Qref (reference energy of kWh 19.070
the declared load profile)
Space heating General Prated kW 32
ηs (Seasonal space heating % 93
efficiency)
P1 (Usefull heat output at 30% of rated heat kW 10.7
output and low-temp regime)
η1 (Useful efficiency at 30% of rated heat % 98.2
output and low-temp regime)
η4 (Useful efficiency at rated heat output and % 88.0
high-temp regime)
P4 (Useful heat output at rated heat output kW 32.0
and high-temp regime)
Seasonal space heating eff. class A
Qhe Annual energy kWh 16,946
consumption (final energy)
Qhe Annual energy Gj 61
consumption (GCV)
Auxiliary elmax (at full load) kW 0.040
electricity
Other ηson (seasonal space heating energy eff. in % 96.670
active mode)
Auxiliary elmin (at part load) kW 0.015
electricity Psb (Standby mode) kW 0.002
consumption
Other NOx emission mg/ 36
kWh
Pign (ignition burner power kW 0.000
consumption)
Pstby (standby heat loss) kW 0.038
Control systems Class of temperature control II
Contribution to seasonal space heating % 2.0
efficiency

Electrical specifications EHYKOMB33AA2


Power supply Name IC3
Phase 1~
Frequency Hz 50
Voltage V 230
Voltage range % 85
% 110
IP class IP IPX4D
Electrical power Max. W 55
consumption Standby W 2
Sensor Feed temperature sensor NTC
Ambient temperature sensor NTC
For conversion to propane in Belgium: contact your dealer |
G20 |
G25 |

EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 9


Daikin Altherma hybrid heat pump

2 Specifications
1 - 3 EHYKOMB-AA2, EHYKOMB-AA3

G31 |
80/60 |
40/30 (30%) |
Refer to operation limits drawing for more details and restrictions |
Setpoint 60°C |
2 Setpoint 40°C |
C63 installations are not allowed in Belgium

Technical specifications EHYKOMB33AA3


CE approval number CE-0063BT3576
Gas Device category C13 / C33 / C43 / C53 / C63 / C83 / C93 / B23 / B33 / C13x / C33x / C43x / C53x / C63x / C83x / C93x
Supply Belgium G20 (20 mbar) / G25 (25 mbar)
pressure Bulgaria G20 (20 mbar) / G31 (37 mbar)
Czech Republic G20 (20 mbar) / G31 (37 mbar)
Denmark G20 (20 mbar) / G31 (30 mbar)
France G20 (20 mbar) / G25 (25 mbar) / G31 (37 mbar)
Germany G20 (20 mbar) / G25 (20 mbar) / G31 (37 mbar)
Greece G20 (20 mbar) / G31 (37 mbar)
Hungaria G20 (20 mbar) / G31 (50 mbar)
Ireland G20 (20 mbar) / G31 (37 mbar)
Italy G20 (20 mbar) / G31 (37 mbar)
Malta G20 (20 mbar)
Poland G20 (20 mbar) / G31 (37 mbar)
Portugal G20 (20 mbar) / G31 (37 mbar)
Slovakia G20 (20 mbar) / G31 (50 mbar)
Slovenia G20 (20 mbar) / G31 (37 mbar)
Spain G20 (20 mbar) / G31 (37 mbar)
Switzerland G20 (20 mbar)
United Kingdom G20 (20 mbar) / G31 (37 mbar)
Category Belgium I2E(S)
Bulgaria II2H3P
Czech Republic II2H3P
Denmark II2H3P
France II2EsI3P
Germany II2ELL3P
Greece II2H3P
Hungaria II2H3P
Ireland II2H3P
Italy II2H3P
Malta I2H
Poland II2E3P
Portugal II2H3P
United Kingdom II2H3P
Connection Diameter mm 15
Consumption Min m³/h 0.79
(G20)
Gas Consumption Max m³/h 3.39
(G20)
Consumption Min m³/h 0.89
(G25) Max m³/h 3.92
Consumption Min m³/h 0.30
(G31) Max m³/h 1.29
NOx class 6
NOx level (G20) mg/ 36
kWh

10 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

2 Specifications
1 - 3 EHYKOMB-AA2, EHYKOMB-AA3

Technical specifications EHYKOMB33AA3
Central heating Heat input Qn Nom Min kW 7.6
(net calorific Max kW 32.7
value)
Heat input Qn Nom Min kW 8.4
2
(gross calorific Max kW 36.3
value)
Output Pn Nom kW 32.0
at 80/60°C
Output at Nom kW 8.3
37/30°C
Factory Output Nom kW 32
setting
Setting Output Nom kW 8.3-32.0
range
Water pressure Max bar 3
(PMS)
Water Max °C 90
temperature
Efficiency Net calorific value % 98
full load Gross calorific value % 88
heat input
Efficiency Net calorific value % 109
part load Gross calorific value % 98
30% Qa
Operation Min °C 30
range Max °C 90
Domestic hot Heat input (net Nom Min kW 7.6
water calorific value) Max kW 32.7
Qnw
Heat input (gross Nom Min kW 8.4
calorific value) Max kW 36.3
Qnw
Comfort class (EN13203) XL
Domestic hot water threshold l/min 2.0
Water Flow rate D Max l/min 15.0
flow (EN13203)
Temperature Max °C 65
Factory setting °C 60
Operation Min °C 40
range Max °C 65
Heat losses Heat loss thermal downtime losses EN 15502-1 38
Supply air Concentric 60/100
Flue gas Temperature Max °C 70
Flue gas Connection mm 60
Length 2x Max m 100
DN80
Length Max m 10
DN60/100
Length Max m 29
DN80/125
Mass flow Max kg/h 15.1
(G20)
Mass flow Max kg/h 15.1
(G25)
Mass flow Max kg/h 14.9
(G31)
Available overpressure Pa 75.0
Condensate drain hose DN 25.0
Mounting Wall
Casing Colour RAL9010
Material Steel
Dimensions Unit Height Casing mm 710
Width mm 450
Depth mm 240
Packed Height mm 900
unit Width mm 500
Depth mm 300
Weight Unit Empty kg 36
Packed Empty kg 38
unit
Packing Material Carton
Weight kg 2
Boiler Water volume l 4.0

EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 11


Daikin Altherma hybrid heat pump

2 Specifications
1 - 3 EHYKOMB-AA2, EHYKOMB-AA3

Technical specifications EHYKOMB33AA3
Heat exchanger Quantity 1
Body material Aluminium
2 3-way valve
Fan motor
Type
Type
None
DC motor
Gas valve Type Siemens VGU76S.C0584
Water circuit - Piping connections diameter mm 22
Central heating Piping material Cu
Pressure Heating Max. bar 3
Air purge valve Yes (Manually)
Drain valve / fill valve No
flowswitch No
Manometer Digital
Sound power level Nom. dBA 50
Piping connections Water inlet heat exchanger diameter mm 22
Piping connections Water outlet heat exchanger diameter mm 22
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manufacturer Name or trademark Daikin Europe N.V.
details
Product Model identifier EHYKOMB33AA3
description Condensing boiler Yes
Low-temperature boiler No
B1 boiler No
Cogeneration space heater No
Combination heater Yes
Combination heater is able to work No
only during off-peak hours
LW(A) Sound Indoor dB(A) 50
power level
Domestic hot General Declared load profile XL
water heating ηwh (water heating % 84
efficiency)
Qelec (Daily electricity kWh 0.071
consumption)
Qfuel (Daily fuel kWh 22.573
consumption)
Water heating energy efficiency A
class
AEC (Annual electricity kWh 16
consumption)
AFC (Annual fuel Gj 18
consumption)
Qref (reference energy of kWh 19.070
the declared load profile)
Space heating General Prated kW 32
P1 (Usefull heat output at 30% of rated heat kW 10.7
output and low-temp regime)
P4 (Useful heat output at rated heat output kW 32.0
and high-temp regime)
ηs (Seasonal space heating % 93
efficiency)
η1 (Useful efficiency at 30% of rated heat % 98.2
output and low-temp regime)
η4 (Useful efficiency at rated heat output and % 88.0
high-temp regime)
Seasonal space heating eff. class A
Qhe Annual energy kWh 16,946
consumption (final energy)
Qhe Annual energy Gj 61
consumption (GCV)
Auxiliary elmax (at full load) kW 0.040
electricity elmin (at part load) kW 0.015
consumption Psb (Standby mode) kW 0.002
Other NOx emission mg/ 36
kWh
ηson (seasonal space heating energy eff. in % 96.670
active mode)
Pign (ignition burner power kW 0.000
consumption)
Pstby (standby heat loss) kW 0.038
Control systems Class of temperature control II
Contribution to seasonal space heating % 2.0
efficiency

12 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

2 Specifications
1 - 3 EHYKOMB-AA2, EHYKOMB-AA3

Electrical specifications EHYKOMB33AA3
Power supply Name IC3
Phase 1~
Frequency
Voltage
Hz
V
50
230
2
Voltage range % 85
% 110
IP class IP IPX4D
Electrical power Max. W 55
consumption Standby W 2
Sensor Feed temperature sensor NTC
Ambient temperature sensor NTC
For conversion to propane in Belgium: contact your dealer |
G20 |
G25 |
G31 |
80/60 |
40/30 (30%) |
Refer to operation limits drawing for more details and restrictions |
Setpoint 60°C |
Setpoint 40°C |
C63 installations are not allowed in Belgium

Technical specifications EHYHBH05AV32 EHYHBH08AV32


Outdoor unit EVLQ05CAV3 EVLQ08CAV3
Power input Nom. kW 0.08 (1)
Casing Colour White
Material Precoated sheet metal
Dimensions Unit Height mm 902
Width mm 450
Depth mm 164
Packed Height mm 1,240
unit Width mm 528
Depth mm 262
Weight Unit kg 30.0 31.2
Packed unit kg 33 34
Packing Material Carton / EPS / PP (Straps)
Weight kg 3
PED Category Art3§3 / Excluded from scope of PED due to article Category I
1, item 3.6 of 97/23/EC
Most Name - Plate heat exchanger
critical Ps*V Bar*l - 51
part
Pump Nr of speeds Inverter controlled
Nominal Heating kPa 51.8 (2) / 55.7 (3) 19.2 (2) / 26.0 (3)
ESP unit
Power input W 45
Water side Heat Type Brazed plate
exchanger Quantity 1
Water volume l 0.90 1.30
Water Min. l/min 7.0 (4) 8.0 (4)
flow rate Heating Nom. l/min 12.6 (2) / 11.6 (3) 21.2 (2) / 19.8 (3)
Max. l/min 23.0 (5) 23.5 (5)
Insulation material Elastomeric foam
Expansion vessel Volume l 10
Max. water pressure bar 3
Pre pressure bar 1
Water filter Diameter perforations mm 1.0
Material Copper - brass - stainless steel
Water circuit Piping connections diameter mm 22
Safety valve bar 3
Manometer No
Drain valve / fill valve No
Water circuit Shut off valve No
Air purge valve Yes
Refrigerant circuit Gas side diameter mm 15.9
Liquid side diameter mm 6.35
Sound power level Nom. dBA 42.0
Operation range Heating Ambient Min. °C -25 (6)
Max. °C 25 (6)
Water side Min. °C 25 (6)
Max. °C 55 (6)

EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 13


Daikin Altherma hybrid heat pump

2 Specifications
1 - 3 EHYKOMB-AA2, EHYKOMB-AA3

Electrical specifications EHYHBH05AV32 EHYHBH08AV32
Power supply Name V3
Phase 1~
2 Frequency
Voltage
Hz
V
50
230
Voltage Min. % 10
range Max. % 10
Wiring Communication Quantity 4G
connections cable Type of wires 1,5mm²
Electric Quantity 2
meter Remark Minimum 0.75 mm² (5VDC pulse detection)
Gas meter Quantity 2
Remark Minimum 0,75 mm² (5VDC pulse detection)
Preferential Quantity Power: 2 / Signal: 2
kWh rate power Remark Power 6.3A (Select diameter and type according to national and local regulations) / Signal: 0,75 mm² till
supply 1,25 mm² (max length 50m)
Domestic Quantity 2
hot water Remark Minimum 0.75 mm² (2A inrush, 1A continuous)
pump
For connection Quantity Wire included in option EKHWP*
with R5T Remark Wire included in option EKHWP*
For connection Quantity 2
with R6T Remark Minimum 0.75 mm²
For connection Quantity Depends on thermostat type, cf. installation manual
with A3P Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max. current: 100mA
/ Min. 0.75mm²
For connection Quantity 2
with M2S Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max. current: 100mA
/ Min. 0.75mm²
For connection Quantity 3
with M3S Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max. current: 100mA
/ Min. 0.75mm²
For connection Quantity 2
with user Remark 0.75 mm² till 1.25 mm² (max length 500m)
interface
For connection Quantity 4
with optional Remark 100 mA, minimum 0.75 mm²
FWXV* (demand
(1)Only for indoor unit |
(2)DB/WB 7°C/6°C - LWC 35°C (DT=5°C), boiler bypassed |
(3)DB/WB 7°C/6°C - LWC 45°C (DT=5°C), boiler bypassed |
(4)Min. required |
(5)Boiler bypassed |
(6)For operation range of *HYHB* and *HYKOMB33AA, see operation range drawing |
Tamb 35°C - LWE 7°C (DT=5°C), boiler bypassed |
Tamb 35°C - LWE 18°C (DT=5°C), boiler bypassed

Technical specifications EHYHBX08AV3


Outdoor unit EVLQ08CAV3
Power input Nom. kW 0.08 (1)
Casing Colour White
Material Precoated sheet metal
Dimensions Unit Height mm 902
Width mm 450
Depth mm 164
Packed Height mm 1,240
unit Width mm 528
Depth mm 262
Weight Unit kg 31.2
Packed unit kg 34
Packing Material Carton / EPS / PP (Straps)
Weight kg 3
PED Category Category I
Most Name Plate heat exchanger
critical Ps*V Bar*l 51
part
Pump Nr of speeds Inverter controlled
Nominal Heating kPa 19.2 (2) / 26.0 (3)
ESP unit Cooling kPa 26.5 (5) / 44.8 (4)
Power input W 45

14 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

2 Specifications
1 - 3 EHYKOMB-AA2, EHYKOMB-AA3

Technical specifications EHYHBX08AV3
Water side Heat Type Brazed plate
exchanger Quantity 1
Water volume
Water Min.
l
l/min
1.30
8.0 (6)
2
flow rate Heating Nom. l/min 21.2 (2) / 19.8 (3)
Max. l/min 23.5 (7)
Cooling Nom. l/min 15.4 (4) / 19.7 (5)
Insulation material Elastomeric foam
Expansion vessel Volume l 10
Max. water pressure bar 3
Pre pressure bar 1
Water filter Diameter perforations mm 1.0
Material Copper - brass - stainless steel
Water circuit Piping connections diameter mm 22
Safety valve bar 3
Water circuit Manometer No
Drain valve / fill valve No
Shut off valve No
Air purge valve Yes
Refrigerant circuit Gas side diameter mm 15.9
Liquid side diameter mm 6.35
Sound power level Nom. dBA 42.0
Operation range Heating Ambient Min. °C -25 (8)
Max. °C 25 (8)
Water side Min. °C 25 (8)
Max. °C 55 (8)
Cooling Ambient Min. °CDB 10 (8)
Max. °CDB 43 (8)
Water side Min. °C 5 (8)
Max. °C 22 (8)

Electrical specifications EHYHBX08AV3


Power supply Name V3
Phase 1~
Frequency Hz 50
Voltage V 230
Voltage Min. % 10
range Max. % 10
Wiring Communication Quantity 4G
connections cable Type of wires 1,5mm²
Electric Quantity 2
meter Remark Minimum 0.75 mm² (5VDC pulse detection)
Gas meter Quantity 2
Remark Minimum 0,75 mm² (5VDC pulse detection)
Preferential Quantity Power: 2 / Signal: 2
kWh rate power Remark Power 6.3A (Select diameter and type according to national and local regulations) / Signal: 0,75 mm² till
supply 1,25 mm² (max length 50m)
Domestic Quantity 2
hot water Remark Minimum 0.75 mm² (2A inrush, 1A continuous)
pump
For connection Quantity Wire included in option EKHWP*
with R5T Remark Wire included in option EKHWP*
For connection Quantity 2
with R6T Remark Minimum 0.75 mm²
For connection Quantity Depends on thermostat type, cf. installation manual
with A3P Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max. current: 100mA
/ Min. 0.75mm²
For connection Quantity 2
with M2S Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max. current: 100mA
/ Min. 0.75mm²
For connection Quantity 3
with M3S Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max. current: 100mA
/ Min. 0.75mm²
For connection Quantity 2
with user Remark 0.75 mm² till 1.25 mm² (max length 500m)
interface
For connection Quantity 4
with optional Remark 100 mA, minimum 0.75 mm²
FWXV* (demand
(1)Only for indoor unit | (6)Min. required |
(2)DB/WB 7°C/6°C - LWC 35°C (DT=5°C), boiler bypassed | (7)Boiler bypassed |
(3)DB/WB 7°C/6°C - LWC 45°C (DT=5°C), boiler bypassed | (8)For operation range of *HYHB* and *HYKOMB33AA, see operation range drawing
(4)Tamb 35°C - LWE 7°C (DT=5°C), boiler bypassed |
(5)Tamb 35°C - LWE 18°C (DT=5°C), boiler bypassed |

EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 15


Daikin Altherma hybrid heat pump

3 Combination table
3-1 Combination Table

EHYHBH(X)‐AV3(2)
EHYKOMB‐AA()
Outdoor combination table for *HYHB*AAV3*
*VLQ05CAV3 *VLQ08CAV3

3
*HYHBH05AAV3 Heating only o
EHYHBH05AAV32 Heating only o
*HYHBH08AAV3 Heating only o
EHYHBH08AAV32 Heating only o
*HYHBX08AAV3 Reversible type o

*HYKOMB33AA
*HYKOMB33AA2 Kit availability for *HYKOMB33AA* *HYKOMB33AA
*HYKOMB33AA3 *HYKOMB33AA2
*HYHBH05AAV3 Heating only o Reference Description *HYKOMB33AA3
EHYHBH05AAV32 Heating only o EKHY075787 Propane set (G30, G31) o
*HYHBH08AAV3 Heating only o EKHY090717 Concentric connection set 80/125 o
EHYHBH08AAV32 Heating only o EKHY093467 Boiler cover o
*HYHBX08AAV3 Reversible type o EKHY090707 Excentric connection set o

Kit availability for outdoor units
*VLQ05CAV3 *VLQ08CAV3
EKDP008CA Drain pan kit o o
EKDPH008CA Heater tape kit o o
EKFT008CA U‐beams for outdoor unit o o

Kit availability for *HYHB*AAV3*
Reference Description *HYHBH05AAV3 EHYHB05AAV32 *HYHBH08AAV3 EHYHBH08AAV32 *HYHBX08AAV3

EKRSCA1 (1) Remote sensor for outdoor o o o o o
KRCS01‐1 (1) Remote sensor for indoor o o o o o
*KRUCBL1 User interface language group 1 o o o o o
*KRUCBL2 User interface language group 2 o o o o o
EKRP1HBAA (2) Digital I/O PCB o o o o o
KRP1AHTA (3) Demand PCB o o o o o
*KRTWA Wired room thermostat o o o o o
*KRTR1 Wireless room thermostat o o o o o
*KRTETS (4) External temperature sensor option kit o o o o o
(R)FWXV15AVEB (5) Heat pump convector o o o o o
(R)FWXV20AVEB (5) Heat pump convector o o o o o
*KVKHPC (5) Valve kit Heat pump convector o o o o o
EKPCCAB1 (6) PC cable kit o o o o o
EKPCCAB2 (6) PC cable kit o o o o o
EKHYDP1 Drain pan kit ‐ ‐ ‐ ‐ o
EKHWP300 (7) Domestic hot water tank o o o o o
EKHWP500 (7) Domestic hot water tank o o o o o
K.HEATMET Energy measuring kit ‐ o ‐ o ‐
EKVK1A Valve kit o o o o o
EKVK2A Valve kit o o o o o
EKVK3A Valve kit o o o o o
EKHYMNT1A Mounting jig o o o o o
EKHYMNT2A Mounting jig Only for BE, FR o o o o o
EKHYMNT3A Mounting jig Only for UK o o o o o
EKTH2 (8) Thermistor for recirculation without tank o o o o o
EKHY3PART (8) Third‐party tank connection kit for thermistor pocket o o o o o
EKHY3PART2 (8) Third‐party tank connection kit for thermostat contact o o o o o
(1) Only 1 remote sensor can be connected: indoor OR outdoor sensor.
(2) PCB that provides additional output connections:
(a) Control external heat source (bivalent operation).
(b) Output remote ON/OFF signal space heating/cooling
(c) Remote alarm output
(d) Solar pump connection
(3) PCB to receive up to 4 digital inputs for power limitation
(4) Can only be used in combination with the wireless room thermostat.
(5) The valve kit is mandatory if a heat pump convector is installed on a reversible model (not mandatory for heating only models).
(6) Data cable for connection with PC.
(7) To connect, use EKEPHT3H.
Remark Other combinations than mentioned in this combination table are prohibited.
(8) From software version MiconID 42F1 onwards.
Use the Updater tool to upgrade the Hydro PCB.

3D082251E

16 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

Dimensional drawings
Dimensional Drawings

EH YH B H- AV 32
EH YK OM B-A A*

350
4
14

13 105
450 405
4

55
139 200
1 Gas pipe connection ·Ø15.9 flare·
2 Liquid pipe connection ·Ø6.35 flare·
186

3 Safety valve
4 Air purge
5 Water filter
6 Water in connection ·(Ø22mm)·
7 Water out connection ·(Ø22mm)·

899
8 Domestic hot water: cold water in ·(Ø15mm)·

9 Domestic hot water: hot water out ·(Ø15mm)·

10 Gas pipe connection ·(1/2")·


15 15 11 Control wiring intake ··
Power supply wiring intake ··
12 Drain outlet ·(Ø25mm)·
121

16 13 Flue pipe / air supply ·(Ø60/100mm)·


3
65

76

14 Air purge
121

15 Copper clamp connection ·(22mm)·


7 17 6 5
16 Boiler cover
178 130
17 Screw connection ·(G1/4")·
243
9 Only for ·EHYHBH*V32·
63 10

8
12

The typical field installation has to be done according to the applicable legislation.

11
215
195

35 127
33
45
55

2 1
79
251 48
3 D 0 82 2 33 A

EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 17


Daikin Altherma hybrid heat pump

Centre of gravity
Centre of Gravity


18 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

Piping diagrams
Piping Diagrams

EHYHBH(X)-AV3(2)
EHYKOMB-AA*
Water side Refrigerant side
1 Space heating/cooling water IN
2 Space heating/cooling water OUT 6
3 Shut-off valve with drain/fill valve
4 Expansion vessel
12 5 Filter
6 Pump
7 Plate heat exchanger
8 Air purge
9 Flow sensor
13
10 3-way valve
14 11 Safety valve
12 Gas boiler
15
9 8 13 Domestic hot water: hot water out
14 Gas pipe
11
15 Domestic hot water: cold water in
16
16 R1T - PHE Outlet water thermistor
17 17 R2T - Outlet water thermistor
1
M 18 R3T - Liquid
10 19 R4T - Inlet water thermistor
20 Screw connection

3 20 Only for ·EHYHBH*V32·

7
4

6
5 19 18

Screw connection

Quick coupling

Brazed connection

Flare connection
3D082238A

EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 19


Daikin Altherma hybrid heat pump

Wiring diagrams
Wiring Diagrams - Single Phase


20 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

Wiring diagrams
Wiring Diagrams - Single Phase


EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 21


Daikin Altherma hybrid heat pump

Wiring diagrams
Wiring Diagrams - Single Phase


22 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

External connection diagrams


External Connection Diagrams


EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 23


Daikin Altherma hybrid heat pump

Installation
Installation Method

EHYHBH-AV32
EHYKOMB-AA*
9

Required space for service and installation

300
350

500

> 500 *

* In combination with the mounting- and/or valve kit, 800mm is required.

4D084025C

24 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3


Daikin Altherma hybrid heat pump

Installation
Installation Method


EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3 25


Daikin Altherma hybrid heat pump

Hydraulic performance
Static Pressure Drop Unit

EHYHBH(X)-AV3(2)

External static pressure [kPa] *HYHBH05AAV3*


10

External static
pressure [kPa]

(*)

Minimum flow: 5l/min

Water flow rate [l/min]


The boiler is bypassed. (*) Heating capacity: 20kW
The boiler is not bypassed. ΔT: 20K

External static pressure [kPa] *HYHBH08AAV3*, *HYHBX08AAV3

External static
pressure [kPa]

(*)

Minimum flow: 5l/min

Water flow rate [l/min]


The boiler is bypassed. (*) Heating capacity: 22,3kW
The boiler is not bypassed. ΔT: 20K

Notes
(1) Selecting a flow outside the operating area can damage the unit or cause the unit to malfunction.
See also the minimum and maximum allowed water flow range in the technical specifications.
(2) Water quality must be according to EU directive 98/83 EC.

4D082239B
26 EHYKOMB-AA2 / EHYKOMB-AA3 / EHYHBH-AV32 / EHYHBX-AV3
Daikin Europe N.V.  Naamloze Vennootschap · Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)

The present leaflet is drawn up by way of information only and does not constitute an
offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of
this leaflet to the best of its knowledge. No express or implied warranty is given for the
completeness, accuracy, reliability or fitness for particular purpose of its content and the
products and services presented therein. Specifications are subject to change without prior
notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in
EEDEN20 10/2020
the broadest sense, arising from or related to the use and/or interpretation of this leaflet.
All content is copyrighted by Daikin Europe N.V.

You might also like