Professional Documents
Culture Documents
ª*&&&
surface of these heatsinks, fins are provided to increase exposed Rth,i-a for plastic housing from simulation and experiment is
area of the housing. This increase in exposed area will result in shown in Fig 2. Rth,i-a is calculated as follows:
lower convective and radiative thermal resistance of the housing.
ȟ୧ିୟ
Plastic variants of the housing lack heatsinks and fins because of ୲୦ǡ୧ିୟ ൌ
poor thermal conductivity of plastic.
Since simulation results were found to be within 4% of the
B. Simulation model measurement results, it can be assumed that the model is
realistic.
(a)
(b)
Fig. 1 Simulation model: (a) Metallic housing with heatsink and fins III. ANALYSIS OF RESULTS
(b) Plastic housing
Lifetime of electronic components depends on the internal
Steady state thermal simulations were carried out in
air temperature (Ti) of the housings. This is why, the temperature
FloTHERMTM. All three modes of heat transfer, i.e. conduction, rise of internal air over ambient temperature i.e. temperature
convection and radiation were considered. PCB was modeled as difference between internal air and ambient (ΔTi-a) was chosen
a lumped cuboid with equivalent orthotropic thermal as the parameter for comparison of different orientations in the
conductivity of an automotive standard PCB. For simplicity of following studies. For the estimation of Ti one can use either of
the model, connector was not considered as part of the following two approaches. The first approach is to use an
geometry. The size of housings under study were similar to average value from temperature probes placed within the
those of typical electronic housings used in automotive internal volume of housing. The second approach is to estimate
applications. The length and breadth of housings were modeled Ti by generating iso-surfaces. For the results presented in the
to be equal. Metallic housings were considered to be made of following sections, the latter approach was used. However, the
standard aluminum die cast material. Plastic housings were conclusions remain the same irrespective of the approach used.
considered to be made of Polyamide-66 material. The value of For first study, forced convection airflow was considered.
emissivity for Polyamide-66 was considered significantly larger For rest of the studies, natural convection airflow is considered
as compared to that of Aluminum die cast material. Fig. 1 shows around the housing.
metallic and plastic housing models used for simulation. For
metallic housing, the two heatsinks were considered to be of A. Effect of orientation of metallic housings w.r.t. incident air
unequal surface areas. For plastic housing, the top cover was flow
considered to be of greater height than bottom cover.
In this section we study the effect of different airflow
An ambient temperature (Ta), which is typical in automotive
directions (as shown in Fig. 3) on ΔTi-a of metallic housings. This
application, was used for the simulation. In the study
study is applicable for electronic housings placed in forced
concerning incident airflow, velocity of incoming air was airflow environments e.g. ECUs placed behind radiator fans. In
assumed to be 2 m/s, which is as per automotive standard. this study, for all airflow directions, the plane of the housing is
C. Thermal loads on ECU assumed to be horizontal i.e. perpendicular to gravity as shown
in Fig. 3.
A total heat generation of 10 W caused by power losses in
components is spread evenly over PCB volume. Further, in one
of the studies, effect of solar radiation is considered. For worst-
case analysis, conditions of 12 noon of June 21, for latitude of
12.97 °N (Bangalore), were used to calculate solar load on ECU.
Orientation ΔTi-a, °C
A 7
(a) ΔTi-a = 7 (°C) (b) ΔTi-a = 7 (°C)
B 9
Fig. 7 Internal air temperature (Ti) of metallic housing for directions
C 9 A and E of airflow
D 20
B. Effect of orientation of metallic housings w.r.t. gravity
E 7
The effect on ΔTi-a of different orientations of metallic
F 8 housings w.r.t gravity direction (as shown in Fig. 8) is studied.
The temperature rise of internal air (ΔTi-a) for the three given
orientations of gravity is given in Table. III. It was observed that
ΔTi-a is minimum for direction C of gravity i.e. when the plane
of the housing is vertical. As shown in Fig 12 (a)-(b), for
direction C i.e. when plane of ECU is vertical, the column of
rising hot air near the PCB accelerates to gain higher velocity as
it comes in contact with the entire length of the PCB. Higher
momentum leads to better heat transfer by convection. For
(b) direction A, as shown in Fig 13 (a)-(b), the vertical movement of
Fig. 9 Direction B of gravity for metallic housing: (a) Velocity vector air is restricted. In addition, the rising hot air comes in contact
plot (b) Speed contour plot
with shorter length of PCB. This causes poor air movement, thus
leading to less effective heat transfer by convection. Similar
TABLE II. RISE OF INTERNAL AIR TEMPERATURE FOR DIFFERENT phenomenon is observed for direction B. The internal air
ORIENTATIONS OF METALLIC HOUSING W.R.T. GRAVITY temperature plot for direction C of gravity is shown in Fig. 14.
Orientation ΔTi-a, °C
TABLE III. RISE OF INTERNAL AIR TEMPERATURE FOR DIFFERENT
A 21 ORIENTATIONS OF PLASTIC HOUSING W.R.T. GRAVITY
B 19 Orientation ΔTi-a, °C
C 21 A 18
D 20 B 18
E 20 C 14
F 21
(a)
ΔTi-a = 19 (°C)
Fig. 10 Internal air temperature (Ti) of metallic housing for direction
B of gravity
IV. CONCLUSION
The internal air temperature (Ti) of an electronic housing is
a critical indicator of the lifetime of that electronic product.
Certain orientations of the housing result in lower ΔTi-a as
compared to others. For metallic housings under incident
airflow, least ΔTi-a is achieved either when airflow direction is
(b)
Fig. 13 Direction A of gravity for plastic housing: (a) Velocity vector
aligned with the length of the fins or when airflow is directed
plot (b) Speed contour plot towards top of the fins. For metallic and plastic housings under
natural convection airflow, ΔTi-a is minimum when the plane of
the housing is vertical. Moreover, for metallic housings ΔTi-a is
minimum when the fins are vertical and heatsink areas lie
towards the top. In addition, when solar radiation acts on plastic
housings least ΔTi-a is observed when the plane of the ECU is
vertical.
For same orientation of plastic housing w.r.t. gravity, it was
observed that ΔTi-a increases by 17 °C with addition of solar load
on the housing. This shows that it is important to consider the
effect of solar radiation for relevant applications.
ΔTi-a = 14 (°C) For natural convection airflow, ratio of heat transfer by
Fig. 14 Internal air temperature (Ti) of plastic housing for direction C
of gravity convection to heat transfer by radiation (Rc-r) is studied. For
metallic housings, Rc-r is observed to be approximately 2:1. For
plastic housings, Rc-r is found to be approximately 1:3. This
D. Effect of orientation of plastic housings w.r.t. solar shows that radiation is a major mode of heat transfer in case of
radiation plastic housings. Therefore, surroundings of the mounting
The effect on ΔTi-a of different orientations of plastic location also play a critical role in case of plastic housing.
housings w.r.t solar radiation (as shown in Fig. 15) is studied. In Whereas, for metallic housings, the airflow around the
addition to heat generation of 10 W, solar radiation is considered, electronics plays a critical role.
details of which are mentioned in section I-C. This study is
The studies carried out in this paper can help design
applicable for electronic housings mounted in environments
engineers in choosing an optimum orientation for their electronic
exposed to solar radiation e.g. ECUs mounted on outer body of
products.
an off-road automotive.
ACKNOWLEDGMENT
We are very grateful to our organization, Robert Bosch
Engineering and Business Solution Pvt. Ltd., for giving us an
opportunity to conduct this research. We are also grateful for the
assistance provided by our family, friends and colleagues
towards writing this paper. Special thanks to Sarvesh Talaulicar,
(a) (b) Vipindas Othiyil and Lakshmikanth G for giving us necessary
Fig. 15 Different orientations of plastic housing w.r.t. solar radiation
approvals to present this paper in the conference.
For given two orientations the temperature rise of internal air
(ΔTi-a) is given in Table II. It was observed that ΔTi-a is minimum
for case (b) of Fig. 15 i.e. when the plane of the housing is
vertical. This is a result of lesser projected-area perpendicular to
REFERENCES Conference on Engineering Analysis, Modeling, Simulation and 3D-
Printing (NAFEMS-3D) – 2016
[1] Nitesh Kumar Sardana, Susyamala Pavan Kumar Busam, Dr. Laxmidhar
Biswal, “Simulation Driven Design Optimization for Reduction of [2] Nitesh Kumar Sardana, Ritwik Alok Pattnayak, Susyamala Pavan Kumar
Temperature on a High Current Density PCB,” International NAFEMS Busam, Chandan Kumar Ghosh ,and Laxmidhar Biswal, “Thermal
Analysis of a battery in an electronic device for an outdoor application,”
ICEP 2016 Proceedings