The COMMAND PULSE Check the controller's command Set the Servo Drive's pulse
mode (Pn007) selection is pulse type and the Servo Drive's type to match the controller's
incorrect. command pulse type. command pulse type.
The zero speed designation In MONITOR mode, check whether · Turn ON the VZERO signal.
(VZERO) is OFF. the VZERO signal is ON or OFF. · Wire correctly.
The internally set speeds are not set. Check the set value of Pn304 to Pn311. Set the desired speeds.
The No. 1 Torque Limit Check the set value of Pn013 and Return the set value to the
(Pn013) or No. 2 Torque Pn522. default setting.
Limit (Pn522) is set to 0.
The motor power cable is Check the wiring. Wire correctly.
11 wired incorrectly.
The encoder cable is wired
incorrectly.
Error and Maintenance
The control I/O connector Check the command pulse's wiring. Wire correctly.
(CN1) is wired incorrectly.
Check the command pulse type. Set the Servo Drive's pulse
type to match the controller's
command pulse type.
Check the command pulse's voltage. Connect a resistor that
matches the voltage.
The power supply is not ON. Check whether the power supply is Turn ON the power supply.
ON and check the PWR LED indicator.
Check the voltage across the power Wire the power supply's ON
supply terminals. circuit correctly.
The speed command is Check if the speed command · Set the external analog
disabled. method is correct. command correctly.
· Set the internal speed correctly.