You are on page 1of 5

METHOD STATEMENT

SYARIKAT Water Tightness Test for Aluminium Door


PEMBINAAN and Window Frame
Page No. : 1 of 5
ANGGERIK SDN. Revision No. : 00
BHD. Date Issued : 10 December 2020

REF : WMS/SPASB/PHOMES/ARC/35

AUTHORIZATION AND RECORD

PROJECT TITLE: THE PROPOSED CONSTRUCTION AND COMPLETION OF 107 UNITS 2 ½


STOREY HYPERLINK TERRACE HOUSE AT SUB-PRECINCT 14-2 (PHASE 2),
PRECINCT 14, PUTRAJAYA

Prepared by Reviewed by Approved by


Rev. Description Date
(Contractor) (Consultant)

Water
Tightness Test
Muhammad Architect
R02 for Aluminium
Azammuddin Coordinator
Door and
Frame

TABLE OF CONTENTS

Ref. Description

1.0 OBJECTIVE

2.0 SCOPE OF WORKS

3.0 RESPONSIBILITIES

4.0 MATERIALS

5.0 EQUIPMENT

6.0 TEST METHODOLOGY

7.0 TEST PROCEDURE

8.0 CHECKLIST OR INSPECTION FORM

ISSUED DATE: 10/12/2020 SYARIKAT PEMBINAAN ANGGERIK SDN. BHD.


PAGE 1 OF 5 WATER TIGHTNESS TEST FOR ALUMINIUM DOOR
REV 00
AND WINDOW FRAME
METHOD STATEMENT
SYARIKAT Water Tightness Test for Aluminium Door
PEMBINAAN and Window Frame
Page No. : 2 of 5
ANGGERIK SDN. Revision No. : 00
BHD. Date Issued : 10 December 2020

REF : WMS/SPASB/PHOMES/ARC/35

1.0 OBJECTIVE
The objective of the test is to determine of joints on the aluminium windows and doors of the
building.

2.0 SCOPE OF WORK


The scope of works to perform watertightness test at installed aluminum door and frame.

3.0 RESPONSIBILITIES
Architecture Coordinator
Architecture Supervisor
Project Engineer
Site supervisor (Mr Najib)

4.0 MATERIALS

4.1 Indoor Sealant : Pantable 995 Silicone Sealant


4.2 Outdoor Sealant : SG-30 Neautral Silicone Sealent

5.0 EQUIPMENT

Water pipe hose.


Water Spray Nozzle Gun
Pipe Connector

6.0 TEST METHODOLOGY


A steady spray test pressure gusting to simulate wind-driven rain is applied on the windows and
doors joints. The water spray is directed at the joint and perpendicular to the face of the window
and door. All joints and gaps are seal by approve sealant for indoor and outdoor. The test are
check around 5 minutes.

ISSUED DATE: 10/12/2020 SYARIKAT PEMBINAAN ANGGERIK SDN. BHD.


PAGE 2 OF 5 WATER TIGHTNESS TEST FOR ALUMINIUM DOOR
REV 00
AND WINDOW FRAME
METHOD STATEMENT
SYARIKAT Water Tightness Test for Aluminium Door
PEMBINAAN and Window Frame
Page No. : 3 of 5
ANGGERIK SDN. Revision No. : 00
BHD. Date Issued : 10 December 2020

REF : WMS/SPASB/PHOMES/ARC/35

7.0 TEST PROCEDURE


1. The hose is connected to nearest water sourse.
2. The water is spray to the aluminium door and window for 5 minutes. The water spray
will cover all joints of the aluminium door and window.
3. The test is considered failed when there is a leakage detected after all joints have be
spray.
*Leakage is defined as any appearance of uncontrolled water seeping through inside of
window and door.

8.0 CHECKLIST OR INSPECTION FORM

The attached checklist form to be used to verify the quality of the work.
(Please refer to attachment)

Attachment 1: Request for Work Inspection (RFWI)


Attachment 2: Inspection Checklist For Watertightness

ISSUED DATE: 10/12/2020 SYARIKAT PEMBINAAN ANGGERIK SDN. BHD.


PAGE 3 OF 5 WATER TIGHTNESS TEST FOR ALUMINIUM DOOR
REV 00
AND WINDOW FRAME
METHOD STATEMENT
SYARIKAT Water Tightness Test for Aluminium Door
PEMBINAAN and Window Frame
Page No. : 4 of 5
ANGGERIK SDN. Revision No. : 00
BHD. Date Issued : 10 December 2020

REF : WMS/SPASB/PHOMES/ARC/35

ATTACHMENT 1

ISSUED DATE: 10/12/2020 SYARIKAT PEMBINAAN ANGGERIK SDN. BHD.


PAGE 4 OF 5 WATER TIGHTNESS TEST FOR ALUMINIUM DOOR
REV 00
AND WINDOW FRAME
METHOD STATEMENT
SYARIKAT Water Tightness Test for Aluminium Door
PEMBINAAN and Window Frame
Page No. : 5 of 5
ANGGERIK SDN. Revision No. : 00
BHD. Date Issued : 10 December 2020

REF : WMS/SPASB/PHOMES/ARC/35

ATTACHMENT 2

ISSUED DATE: 10/12/2020 SYARIKAT PEMBINAAN ANGGERIK SDN. BHD.


PAGE 5 OF 5 WATER TIGHTNESS TEST FOR ALUMINIUM DOOR
REV 00
AND WINDOW FRAME

You might also like