Professional Documents
Culture Documents
중요결함기록서 (SSR) 330 24 001
중요결함기록서 (SSR) 330 24 001
Contents
Engineer 조유석 Date 2012년 01월 27일 Team 정비기술팀 TelNo 032-742-3194
중요결함기록서
Doc No 중요결함기록서(SSR)-330-24-001 Doc Type AC Type 330
(SSR)
SUBJ (STN) HL7586 'ESS TR FAULT' Message
COMPONENT ITEM NO ATA 24 Effective Y
Effectivity A330 (All)
REF Doc
[ENGLISH VERSION]
On 10th AUG 2011, HL7586 (A330-300) Aircraft, KE9742 Flight was delayed due to 'ESS TR FAULT'
Message display on ECAM at HNL airport.
2. 결함원인
3. 조치 사항
4. 대 책
[고장 탐구 절차]
가. ELEC ESS TR Fault Message Display & ESS TR ~ DC ESS BUS 간 Green Line Disappeared 되는 경우
( * CMC 에서 ESS TR Reset 시도 시 No Message Memory )
☞ ESS TR Contactor Closed Input Signal Error (Open Signal) 경우이므로 해당 Contactor를 교환 할 것.
나. ELEC ESS TR Fault Message Display & ESS TR ~ DC ESS BUS 간 Green Line 정상 Display 되고
SD 상에 "ESS TR" Amber 지시되는 경우
(* CMC 에서 ESS TR Reset 시도 시 CMC Message 24-34-51, TR ESS (1PE) Memory)
☞ ESS TR "E" 단자 (ESS TR Fault Signal) Electrical Ground (Earth)이므로 TRU 작업을 진행 할 것.
5. 참고 사항
운항정비공장장
[ENGLISH VERSION]
2. Causes
ESS TR Contactor itself had a problem providing ESS TR CONACTOR Closed Input Signal to SDAC.
3. Taken Action
A. at HNL
- Same fault happened after ESS TR reset on the ESS TR page of MCDU.
- Same fault still remained after aircraft's all power reset.
- Same fault happened again after replacing ESS TRU.
B. at ICN
- Contact from Pin 19 to Pin 20 of ESS TR CONTACTOR (3PE) was abnormal that
provides ESS TR CONTACTOR CLOSED SIGNAL to SDAC.
* The main contact of the ESS TR contactor (3PE) was normal condition for connecting electrical power.
4. Counter Measure
[Trouble shooting]
A. In case of ELEC ESS TR Fault Message Displayed & Green Line Disappeared Between ESS TR ~ DC ESS BUS.
(* When resetting ESS TR on the CMC, No memorized message.)
☞ Replace the concerned Contactor since tthe root cause of the problem is ESS TR Contactor Closed
Input Signal Error (Open Signal)
B. In case of ELEC ESS TR Fault Message Displayed & Green Line displayed between ESS TR and DC ESS BUS
& "ESS TR" AMBER displayed on SD.
(* When resetting ESS TR on the CMC, TR ESS (1PE) MEMORY (MESSAGE 24-34-51) memorized.)
☞ Replace TRU since the root cause of the problem is ESS TR Fault Signal.
5. Reference
첨부파일