Professional Documents
Culture Documents
Technical Catalogue FP
Technical Catalogue FP
Technical Catalogue
June
2019
Table of contents
Introduction ...................................................................................................... 2
Endhead configuration .................................................................................... 3
Power pack sections ...................................................................................... 7
i
Selection code ................................................................................................. 8
Endhead overall dimensions ....................................................................... 11
Cavities dimensions ...................................................................................... 12
Endhead choice ............................................................................................. 13
Examples ......................................................................................................... 90
© 2019 Dana Motion Systems Italia S.r.l. all rights reserved. Hydr-App, SAM Hydraulik, Aron, Brevini Hydraulics, BPE Electronics, VPS Brevini, OT Oiltechnology,
logos are trademarks or are registered trademarks of Dana Motion Systems Italia S.r.l. or other companies Dana in Italy and other countries.
The technical features supplied in this catalogue are non binding and no legal action can be taken against such material. Dana will not be held responsible
for information and specifications which may lead to error or incorrect interpretations. Given the continuous technical research aimed at improved technical
features of our products, Dana reserves the right to make change that are considered appropriate without any prior notice. This catalogue cannot be reproduced
(in while or in part) without the prior written consent of Dana. This catalogue supersedes all previous ones.
Use of the products in this catalogue must comply with the operating limits given in the technical specifications. The type of application and operating
conditions must be assessed as normal or in malfunction in order to avoid endangering the safety of people and/or items.
IE/FP-INTRO/04-2017 1
Introduction
Operating pressure is controlled by the maximum pressure valve
and the type of pump used (in terms of performance) may be deter-
mined by the maximum pressure valve. Therefore, it is essential not
i to change the maximum pressure valve. If neccessary, contact our
technical service department.
Installation
1) The power pack must be mounted using the M10 holes on the endhead.
2) The power pack must not come into contact with sheet metal, protective
guards or any parts that may vibrate and transmit noise.
3) The ports on the endhead have been identified by the letters A-B -C. The
hydraulic connection must be made with fittings with cylindrical thread
and with copper or rubber sealing gaskets (O-rings).
4) After the electrical connections have been made, check the direction of
motor rotation by executing short pulses of 1 second each (max.): the mo-
tor must turn anti-clockwise, as shown in the figure.
A B C
OI
L
The FP series power pack is an easy-to-assemble, compact, electro-hydraulic
unit. With its versatility and modularity, it offers many combinations of
hydraulic circuits to suit various requirements of plant design. This catalogue
has been written to help the user choose the components for the power pack M
required for the specific application. However, the catalogue cannot foresee
all the combinations that may be executed, so in some cases it may be
necessary to consult our commercial engineering department. 82
For applications with very complex circuits, standard modular blocks for Cetop M10
valves and other special blocks can be installed on the power pack, or blocks
built to order can be included.
The tank must be filled with new mineral-based, ISO 6743/4 fluid: it is
A few applications: important to filter the fluid while filling the tank.
• Fork lifts
• Lifting platforms and beds
• Automotive lifts Symbols used in this catalog:
• Cranes for small trucks
Important data/information
• Snowplows
• Industrial automation (machine tools, food industry, textile industry)
Mounting endhead side
You can chose from a wide variety of components with the following
specifications: Ground floor
• Gear pumps - Group 0.5 / 1 - from 0.25 to 9.8 cc. Electrical connection boxes on AC motors
• DC motors, 12/24 V, light-duty service, from 0.35 to 3 Kw
• Single and triple-phase motors with power ratings of up to 4 Kw - in a Poles and/or starting relays on DC motors
standard version or built to the customer's specifications (with minimum
overall dimensions) Fill plug with breather and level stick
• Tanks in sheet steel with capacities of up to 25 litres
• Tanks in plastic with capacities of up to 10 litres Fill plug with breather
A fundamental part of the power pack is the endhead, which is made of die-cast Standard plug (closed)
aluminum alloy. The parts and dimensions of this component are shown below.
Standard oil fill plug
Operating limits
• Intermittent peak pressure: 290 bar (depending on pump type)
Fill plug with breather
• Maximum flow rate: 20 l/min
• Maximum operating temperature: Fill plug
80°C (with sheet steel tank)
70°C (with polyethylene tank) Fill plug with check valve
60°C (with polypropylene tank)
• Mineral-based hydraulic fluid: ISO 6743-4 (DIN 51524) Fill plug with back check
Minimum viscosity: 12 mm²/s
Drain plug with magnet
Maximum viscosity: 80 mm²/s
Maximum viscosity at start-up: 500 mm²/s Plug (or level stick) with visual indicator
• Minimum ambient temperature -15°C
• Maximum ambient temperature 40°C (with peaks of 50°C) Drain plug
• The validation of the endhead follows a life-test with 250 bar pulsed pres-
sure repeated for 100.000 cycles * Fields to be completed
2 IE/FP-INTRO/04-2017
Endhead configuration
Power pack endhead configuration
FPA i
5TG 5TH
2DA
+
2DB
2DC
2DD
2C
A B 5
2H
A1-B1-C1-D1
2 2FA
2 A2-B2-C2-D2
2Z*
A3-B3-C3-D3
1 1
2TC
K1
2TD
7 6
X1
2TE
2TF 7 6
2TK
7 6
Flow control valves
IE/FP-INTRO/04-2017 3
Endhead configuration
Power pack endhead configuration
2DA 3DD
i 2DB
FPC 3H
2DC 3FA
2DD 3FB
5
2C 5TG 5TH 3A
2H + 3B
3
+
3TC
2 2FA
9
2Z* 3TD
2TC 3TE
2TD 3TF
A B 5 C
2TE 3TK
2TF
2 3
A1-B1-C1-D1
2TK
4 1
A2-B2-C2-D2
4DA
8 7 6 9 A3-B3-C3-D3
4DB
1
4DC K1
8 7 6 9 9TL
4DD X1
4C 8 7 6 9
4H
4 Flow control valves (or plug for cavity 9)
4FA
4Z
4TE
4TF
4TK
4 IE/FP-INTRO/04-2017
Endhead configuration
Power pack endhead configuration
2DA 3DA
2DB
FPL 3DB
i
2DC 2TC 3DC
2 2C 2TE 3H
2H 2TF 3FA
3A 3
2Z*
3B
3TD
4DA A D B C
3TE
4DB
2 3 3TF
4DC
3TK
4DD
4 1
4C
8 7
4H
4
4B
8 7
A1-B1-C1-D1
4FA
A2-B2-C2-D2
4Z 8 7
Flow control valves A3-B3-C3-D3
4TE
1
4TF K1
4TK X1
IE/FP-INTRO/04-2017 5
Endhead configuration
Power pack endhead configuration
i FPE
(for directional control valves)
22D(1A) 2 4
S2 S1
3 1
22D(1B) 2 4 4 3 2
S2 S1 S1 S2 1
3 1
22D(1C) 2 4
S2 S1
3 1
3FA
22D(1D) 2 4
S2 S1
3 1
A D B C 3FB
2D(2A) 2 4 3
+
3 1
3TC
2D(2B) 2 4
2 3 9
3 1
2D(2C) 2 4
A1-B1-C1-D1
2 1
3 1
2D(2D) 2 4
A2-B2-C2-D2
3 1
2D(2E)
4 3 2
2 4 1
3 1
9 A3-B3-C3-D3
2D(3A) 2 4 1
3 1
K1
2D(3B) 2 4 9
3 1
X1
2D(3C) 2 4
3 1
9
2D(3D) 2 4
Flow control valves
3 1
2D(3E) 2 4
3 1
6 IE/FP-INTRO/04-2017
Power pack sections
VIII (J-K-W) VI (M)
II VII (T)
I
IX (R)
IV (S)
With its great modularity, the FP series of power packs can create multiple SECTION IV - TANKS
configurations which satisfy requirements in a wide range of applications. This section is defined by the letter S.
To make it easier to choose components, the power pack is subdivided into Depending on the required features, select the reservoir from the list provided.
sections. If no Reservoir is required, and also no Suction / Return Kit is required, please
omit this section. If no Reservoir is required, but a Suction / Return Kit is
SECTION I - SERIE, FLANGE TYPE, VALVES ON CAVITY 1 required, please jump to Section V (defined by letter G).
FP Series Powerpacks are based on the Flange features.
The Flange is the core of the unit, on the flange are mounted all the valves, SECTION V - TUBES KIT (suction and return, only for tanks on the catalog)
the pump, the motor and the reservoir. This section is defined by the letter G.
The FP Flange is available in several Versions (with different tooling options). In order to define this Section, please select the Reservoir Type anyways.
The Flange Version must be chosen depending on the type of Hydraulic Circuit
Layout required. SECTION VI - MOTORS
Together with the Flange Version, it is required to select the Valves to be This section is defined by the letter M.
mounted in the Various Cavities. Depending on the Type of Hydraulic Circuit Layout to be realized, it is required
1 (Main Pressure Relief Valve). to Select the Motor Type. If no Motor is required, and no Transmission Kit is
required, please omit this section. If no Motor is required, but a Transmission
SECTION II - VALVES Kit is required, please jump to Section VII (defined by letter T).
Depending on the Type of Hydraulic Circuit Layout to be realized, it is required
to Select the Valves for each of the available Cavities. SECTION VII - TRANSMISSION KIT (only for motors on the catalog)
In order to correctly build up the Ordering Code, it is required to use the This section is defined by the letter T.
following procedure. Select the kit as per Table provided.
Peripheral Cavities (it is mandatory to mention all the Cavities in Numeral
Order): starting from Cavity 2, mention all the Cavities and the Valves, Plugs SECTION VIII - BLOCKS
or Fittings to be mounted in said Cavity. This section it is not mandatory, depending on the Type of auxiliary Block
Internal Cavities: normally connected to Tank (It is not mandatory to mention, required, definition Letter changes:
but if required it should be done in Numeral Order): starting from Cavity 6, J, Blocks with CETOP type of interface for Solenoid Valves;
mention all the Internal Cavities where a Valve (usually a Return Line Valve) is K, Bankable Valves Interface – Horizontal (Parallel to Unit Axis);
mounted, Selecting the Valve Type to be mounted in said Cavity. W, Bankable Valves Interface – Vertical (Perpendicular to Unit Axis);
Outputs, see description in the Table.
SECTION IX - ACCESSORIES
SECTION III - PUMPS His section it is not mandatory, is defined by the letter R
It is mandatory to mention this section, defined by the letter P. Check the available options in the list provided.
Depending on the required features, select the pump from the table provided. Accessories must be listed in Alphabetical Order.
IE/FP-INTRO/04-2017 7
Selection code
SECTION I - SERIE, ENDHEAD, VALVES ON CAVITY 1
FP * * * * (...)
SECTION II - VALVES
Cavity 2
Type
Features
Optional flow control valve (omit if not required)
Cavity 3
Type
Features
Flow control valve can be combined with plug TC (omit if not required)
Cavity 4
Type
Features
Cavity 5
Plug
Features
Flow control valve can be combined with plug TG (omit if not required)
Return cavities 6-7-8-9
Optional flow control valve (or plug for cavity 9)
Combination plugs for ports
End section II
2 .. ** +* 3 .. ** +* 4 .. ** 5 T * +* 6 * 7 * 8 * 9 * - ** -
Pump
Pump group
Performance level
Nominal displacement
Accessories (omit if not required)
End section III
P * (*) ** / * -
8 IE/FP-INTRO/04-2017
Selection code
SECTION IV - TANKS / SECTION V - TUBES KIT
Section:
S = tank (with tubes kit) ; i
G = only with tubes kit, without tank;
OMIT if without tank and without tubes kit
Capacity liters
Features (material and construction)
Mounting position:
H = horizontal;
V = vertical
Variants
00 = standard, no variant;
OMIT if with tubes kit (section “G”)
Orientation
OMIT if with tubes kit in vertical mounting position (section “G”)
End section IV and V
* ** * (*) ** /* -
SECTION VI - MOTORS
DC motor
Voltage
Power / Size
Version
Accessories
0 = whitout accessories;
Orientation
End section VI
M * ** (*) * /* -
OR ..
AC motor
Phases
Poles
Size
Power range
Version
Orientation
End section VI
M * * * * (*) /* -
IE/FP-INTRO/04-2017 9
Selection code
SECTION VII - TRANSMISSION KIT (only for motors on the catalog)
i Transmission kit
Type
End section VII
Specify the transmission kit whether you requested the joint and
accessories assembly (without motor).
T ** -
Blocks
Mounting position
Accessory
Separation line
Block type
Accessory
Pressure relief valve setting on “A” line
Pressure relief valve setting on “B” line
CETOP valve
End section VIII
SECTION IX - ACCESSORIES
Accessories (optional)
First accessory
Second accessory
R * *
10 IE/FP-INTRO/04-2017
Endhead overall dimensions
Cavities on endhead: The number of cavities tooled identify the endhead type:
Endhead type
Cavity Thread There are three types of cavities:
A Ports
G1/4” (1)
FPA FPC FPL FPE
• • • •
- Peripheral cavities, which can be accessed externally
- Return cavities, inside of the tank.
i
G3/8” (2) - Ports
G1/4” (1)
B Ports • • • •
G3/8” (2)
G1/4” (1)
C Ports — • • •
G3/8” (2)
D Ports G1/4” (1) — — • • 82
22.5
1 Peripheral 3/4” 16 UNF • • • •
3 2
(FOR ATTACHING TANKS)
4 HOLES WITH Ø7
101.6
134
1 4
8
PORT SIDE
Ø 120
Ø 110
Ø 35
Ø 80
Ø30
118
Ø32
10°
The cavities (1-2-3-4-5) and the ports (A-B-C) are marked on the die-cast endhead. The dimensions on the drawing are the same for all endhead.
IE/FP-INTRO/04-2017 11
Cavities dimensions
Cavity Thread Drawing Cavity Filettatura Drawing
CD018013
i
Ø 16.4
Ø 26
1 Peripheral 3/4 16 UNF 5 Peripheral M16 x 1.5
Ø 14.5
Ø 15.8
Ø 12.7
M16x1.5
7.2
3/4-16 UNF
12
20.5
17.5
24.6
42.5
34 2
62.5 5
CD018009
G3/8
Ø 26
Peripheral
2 3/4 16 UNF 6 Return G 3/8
Ø 12.7
Ø 11.5
(FPA-FPC) 12 15
3/4-16 UNF
17.5 18.5
41
66.5
CD018001
Ø15.9
Ø27
G3/8
Peripheral
2 3/4 16 UNF 7 Return G 3/8
Ø 11.5
Ø 14.3
Ø 12.7
(FPE) 23
3/4-16 UNF
11.5
19.1 37
33.3
47.6
56
CD018014
G3/8
Ø 26
12 21
3/4-16 UNF
17.5 30
30.5
CD018014
G3/8
Ø 26
12 22
3/4-16 UNF
17.5 27
30.5
12 IE/FP-INTRO/04-2017
Endhead choice
Endhead type
Thread ports
FP * *
FP
A C L
A B 5 A B 5 C A D B C
2 2 3 2 3
1 4 1 4 1
7 6 8 7 6 9 8 7
A D B C
2 3
* Endhead type
* Thread ports
Endhead codes
G1/4” G3/8”
FPA 78013010.000 78013011.000
FPC 78013014.000 78013015.000
FPL 78013022.000
FPE 78013016.000
IE/FP/00-2016 13
Sect. I - FPA Cavity 1
A B 5
FPA** * * (...)
I 7 6
FPA A B 5
A1
B1
C1
D1
A2
2 B2
C2
D2
A3
B3
C3
1 D3
K1
7 6
X1
X 1 Plug R78150100
14 IE/FPA-1/04-2019
Sect. II - FPA Cavity 2
Cavity
Type
Features
Optional flow control valve (omit if not required)
FPA** ** (...) 2 .. ** +*
A B 5
2DA** +*
II
2
2DB** +* FPA
2DC** +*
1
2DD** +*
7 6
2C* +*
2H* +*
2FA*
2Z*
A B 5
2TC
2TD
2
G 1/4
2TE
2TF
G 1/4
7 6
2TK
G 1/4
IE/FPA-2/04-2019 15
Sect. II - FPA Cavity 2
2 DA ** +* Piloted solenoid valves normally closed, without emergency (1)
II
2 DB ** +* Piloted solenoid valves normally open, with rotary emergency (1)
FPA
** Description Code (valve + connector) Symbol Drawing
AA Voltage 12 Vdc CRP0418NCAEL003 + V8605002
AB Voltage 24 Vdc CRP0418NCAEM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCAEA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCAEJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCAEI003 + V86050002
2 DD ** +* Direct operated solenoid valve normally closed, with button emergency (1)
16 IE/FPA-2/04-2019
Sect. II - FPA Cavity 2
2 H * +* Button operated valves
2 Z * Hand pumps
A Cilindrata 1 cc CPM0410001
B Cilindrata 2 cc CPM0420001
IE/FPA-2/04-2019 17
Sect. II - FPA Cavity 5
Peripheral
Plug
Features
Flow control valve can be combined with plug TC
FPA** ** (...) 2 .. ** +* 5 T * +*
5TG 5TH
II
FPA
+*
A B 5
A B 5
2
2
1
7 6
1
7 6
5 T * +* Plugs
18 IE/FPA-2/04-2019
Sect. II - FPA Cavity 6-7
Return cavities
FPA** ** (...) 2 .. ** +* 5 T * +* 6 * 7 *
A B 5
II
2 FPA
7 6
A B 5
7* 6*
IE/FPA-2/04-2019 19
Sect. II - FPA Ports A-B
II
FPA
A B 5
2
A B 5
1
2
7 6
7 6
20 IE/FPA-2/04-2019
Sect. I - FPC Cavity 1
A B 5 C
FPC** * * (...)
4 1
8 7 6 9
A B 5 C
A1
B1
C1
D1 I
A2
2 3 B2 FPC
C2
D2
A3
B3
C3
4 1 D3
K1
8 7 6 9
X1
X 1 Plug R78150100
IE/FPC-1/04-2019 21
Sect. II - FPC Cavity 2
Cavity
Type
Features
Optional flow control valve (omit if not required)
FPC** ** (...) 2 .. ** +*
A B 5 C
2DA** +*
2DB** +* 2 3
II 2DC** +*
4 1
FPC
2DD** +*
8 7 6 9
2C* +*
2H* +*
2FA*
2Z*
A B 5 C
2TC
2TD
2 3
G 1/4
2TE
4 1
2TF
G 1/4
8 7 6 9
2TK
G 1/4
22 IE/FPC-2/04-2019
Sect. II - FPC Cavity 2
2 DA ** +* Piloted solenoid valves normally closed, without emergency (1)
2 DD ** +* Direct operated solenoid valve normally closed, with button emergency (1)
IE/FPC-2/04-2019 23
Sect. II - FPC Cavity 2
2 H * +* Button operated valves
2 Z * Hand pumps
A Cilindrata 1 cc CPM0410001
B Cilindrata 2 cc CPM0420001
24 IE/FPC-2/04-2019
Sect. II - FPC Cavity 3
Cavity
Type
Features
Flow control valve can be combined with plug TC
FPC** ** (...) 2 .. ** +* 3 .. ** +*
A B 5 C
3DD*
3H*
2 3
3FA*
II
4 1
3FB* FPC
8 7 6 9
3A**
3B*
+* 3TC
3TD
A B 5 C
G 1/4
3TE
2 3
3TF
G 1/4
4 1 3TK
G 1/4
IE/FPC-2/04-2019 25
Sect. II - FPC Cavity 3
3 DD ** Piloted solenoid valves normally closed, with emergency (1)
II
FPC
3 FA * Bidirectional flow control valves not compensated
26 IE/FPC-2/04-2019
Sect. II - FPC Cavity 3
3 B * One-way check valves
C 10 bar CRU0410002
IE/FPC-2/04-2019 27
Sect. II - FPC Cavity 4
Cavity
Type
Features
FPC** ** (...) 2 .. ** +* 3 .. ** +* 4 .. **
A B 5 C
4DA**
4DB**
2 3
II 4DC**
4 1
FPC
4DD**
8 7 6 9
4C*
4H*
4FA*
4Z* A B 5 C
4TE
2 3
4TF
G 1/4
4TK 4 1
G 1/4
8 7 6 9
28 IE/FPC-2/04-2019
Sect. II - FPC Cavity 4
4 DA ** Piloted solenoid valves normally closed, without emergency (1)
4 DD ** Direct operated solenoid valve normally closed, with button emergency (1)
IE/FPC-2/04-2019 29
Sect. II - FPC Cavity 4
4 C * Lever operated valve
FPC
4 FA * Bidirectional flow control valves not compensated
4 Z * Hand pumps
A Cilindrata 1 cc CPM0410001
B Cilindrata 2 cc CPM0420001
30 IE/FPC-2/04-2019
Sect. II - FPC Cavity 5
Peripheral
Plug
Features
Flow control valve can be combined with plug TG
FPC** ** (...) 2 .. ** +* 3 .. ** +* 4 .. ** 5 T * +*
5TG 5TH
+*
A B 5 C
2 3
4 1 2 3
8 7 6 9
4 1
8 7 6 9
5 T * +* Plugs
IE/FPC-2/04-2019 31
Sect. II - FPC Cavity 6-7-8-9
Return cavities
FPC** ** (...) 2 .. ** +* 3 .. ** +* 4 .. ** 5 T * +* 6 * 7 * 8 * 9 *
Return cavity, omit if not required flow control valves or caps. Optional flow control valves (or plug on cavity 9)
A B 5 C
2 3
II 4 1
FPC A B 5 C
8 7 6 9
2 3
4 1
8* 7* 6* 9* 9L
8 7 6 9
Optional flow control valves (or plug on cavity 9).
32 IE/FPC-2/04-2019
Sect. II - FTC Ports A-B-C
A B 5 C
II
A B 5 C FPC
2 3
2 3
4 1
8 7 6 9
4 1
8 7 6 9
-** A B C
-00 n n
-01 n n n
-02
n n
-03 n
n Symbols description
IE/FPC-2/04-2019 33
Sect. I - FPL Cavity 1
A D B C
FPL** * * (...)
4 1
8 7
A B D C
A1
B1
C1
D1
A2
2 3 B2
C2
D2
A3
I B3
C3
4 1 D3
FPL K1
8 7
X1
X 1 Plug R78150100
34 IE/FPL-1/01-2019
Sect. II - FPL Cavity 2
Cavity
Type
Features
FPL** ** (...) 2 .. **
A B D C
2DA**
2DB** 2 3
2DC**
4 1
2DD**
8 7
II
2C*
FPL
2H*
2FA*
2Z*
A D B C
2TC
2TD
2 3
G 1/4
2TE
4 1
2TF
G 1/4
8 7
2TK
G 1/4
IE/FPL-2/01-2019 35
Sect. II - FPL Cavity 2
2 DA ** Piloted solenoid valves normally closed, without emergency (1)
FPL
2 DC ** Piloted solenoid valves normally open, with button emergency (1)
2 DD ** Direct operated solenoid valve normally closed, with button emergency (1)
36 IE/FPL-2/01-2019
Sect. II - FPL Cavity 2
2 H * Button operated valves
2 Z * Hand pumps
II
* Description Code Symbol Drawing
FPL
A Cilindrata 1 cc CPM0410001
B Cilindrata 2 cc CPM0420001
IE/FPL-2/01-2019 37
Sect. II - FPL Cavity 3
Cavity
Type
Features
FPL** ** (...) 2 .. ** 3 .. **
A B D C
3DA*
3DB*
2 3
3DC*
4 1
3DD*
8 7
II 3H*
FPL
3FA*
3FB*
A D B C 3A**
3B*
2 3
3TD
G 1/4
4 1
3TE
3TF
8 7
G 1/4
3TK
G 1/4
38 IE/FPL-2/01-2019
Sect. II - FPL Cavity 3
3 DA ** Piloted solenoid valves normally closed, without emergency (1)
3 DD ** Direct operated solenoid valve normally closed, with button emergency (1)
IE/FPL-2/01-2019 39
Sect. II - FPL Cavity 3
3 FB * Unidirectional flow control valves compensated
C 10 bar CRU0410002
40 IE/FPL-2/01-2019
Sect. II - FPL Cavity 4
Cavity
Type
Features
FPL** ** (...) 2 .. ** 3 .. ** 4 .. **
A B D C
4DA**
4DB**
2 3
4DC**
4 1
4DD**
8 7
4C*
II
FPL
4H*
4B*
4FA*
4Z* A D B C
4TE
2 3
4TF
G 1/4
4TK 4 1
G 1/4
8 7
IE/FPL-2/01-2019 41
Sect. II - FPL Cavity 4
4 DA ** Piloted solenoid valves normally closed, without emergency (1)
FPL
4 DC ** Piloted solenoid valves normally open, with button emergency (1)
4 DD ** Direct operated solenoid valve normally closed, with button emergency (1)
42 IE/FPL-2/01-2019
Sect. II - FPL Cavity 4
4 B * One-way check valves
C 10 bar CRU0410002
4 Z * Hand pumps
A Cilindrata 1 cc CPM0410001
B Cilindrata 2 cc CPM0420001
IE/FPL-2/01-2019 43
Sect. II - FPL Cavity 7-8
Return cavities
FPL** ** (...) 2 .. ** 3 .. ** 4 .. ** 7 * 8 *
A B D C
2 3
4 1
A D B C
8 7
II
2 3
FPL
4 1
8* 7*
8 7
Optional flow control valves.
44 IE/FPL-2/01-2019
Sect. II - FTL Ports A-B-C-D
A B 5 C
A B 5 C
2 3
II
2 3 FPL
4 1
8 7 6 9
4 1
8 7 6 9
IE/FPL-2/01-2019 45
Sect. I - FPE Cavity 1
A D B C
FPE** * * (...)
A B D C
A1
B1
C1
A2
3 B2
C2
2
A3
B3
C3
1
K1
9
I X1
FPE
X 1 Plug R78150100
46 IE/FPL-1/03-2019
Sect. II - FPE Cavity 2
Cavity
Type
Features
A B D C
22D(1A)** 2 4
S2 S1
3 1
22D(1B)** 2 4
S2
3
S1
2
3 1
4 3 2
22D(1C)**
1
S1 S2 2 4
S2 S1
1
3 1
22D(1D)** 2 4
S2 S1
9
3 1
2D(2A)** 2 4
3 1
2D(2B)** 2 4
II
3 1
FPE
2D(2C)** 2 4
4 3 2
1
3 1
2D(2D)** 2 4
3 1
2D(2E)** 2 4
A D B C
3 1
2D(3A)** 2 4
2 3
3 1
2D(3B)** 2 4
3 1 1
2D(3C)** 2 4
4 3 2
1
3 1
2D(3D)** 2 4 9
3 1
2D(3E)** 2 4
3 1
IE/FPL-2/04-2019 47
Sect. II - FPE Cavity 2
2 D(**) ** Solenoid valves 4 way 3 positions with emergency (1)
(1A)AB Voltage 24 Vdc (closed centre “C” spool) C4V0422C3FEM001 + V86050002 (x2) 3 1
2 4
(1B)AA Voltage 12 Vdc (open centre “A” spool) C4V0422A3FEL001 + V86050002 (x2) S2 S1
(1B)AB Voltage 24 Vdc (open centre “A” spool) C4V0422A3FEM001 + V86050002 (x2) 3 1
4 3 2
1
S1 S2
2 4
(1C)AA Voltage 12 Vdc (centre “H” spool) C4V0422H3FEL001 + V86050002 (x2)
S2 S1
2 4
(1D)AA Voltage 12 Vdc (centre “Y” spool) C4V0422Y3FEL001 + V86050002 (x2) S2 S1
2 4
(2B)AA Voltage 12 Vdc (open centre “A” spool) C4V0422A2FSL001 + V86050002
(2B)AB Voltage 24 Vdc (open centre “A” spool) C4V0422A2FSM001 + V86050002 3 1
4 3 2
1
2 4
(2E)AA Voltage 12 Vdc (direct “D” spool) C4V0422D2FSL001 + V86050002
(2E)AB Voltage 24 Vdc (direct “D” spool) C4V0422D2FSM001 + V86050002 3 1
2 4
(3B)AA Voltage 12 Vdc (open centre “A” spool) C4V0422A2FEL001 + V86050002
(3B)AB Voltage 24 Vdc (open centre “A” spool) C4V0422A2FEM001 + V86050002 3 1
2 4
(3C)AA Voltage 12 Vdc (centre “H” spool) C4V0422H2FEL001 + V86050002
4 3 2
2 4
(3E)AA Voltage 12 Vdc (direct “D” spool) C4V0422D2FEL001 + V86050002
(3E)AB Voltage 24 Vdc (direct “D” spool) C4V0422D2FEM001 + V86050002 3 1
48 IE/FPL-2/04-2019
Sect. II - FPE Cavity 3
Cavity
Type
Features
Flow control valve can be combined with plug TC
A B D C
3FA*
3FB*
3
2
+* 3TC
II
FPE
A D B C
2 3
IE/FPL-2/04-2019 49
Sect. II - FPE Cavity 3
3 FA * Bidirectional flow control valves not compensated
3 T * +* Plug
50 IE/FPL-2/04-2019
Sect. II - FPE Cavity 9
Return cavities
A B D C
3
2
A D B C
2 3
1 II
Optional flow control valve. 9*
FPE
IE/FPL-2/04-2019 51
Sect. II - FTE Ports A-B-C-D
D C
A B D C
A B
3
2 3
2
1 1
II 9
FPE 9
52 IE/FPL-2/04-2019
Sect. III - Pumps
Pump
Pump group
Performance level
Nominal displacement
Accessories (omit if not required)
End section III
FP ........ P * (*) ** / * -
14
5
P 0 (1) ** Pumps group 05 - Performance level 1
G1/4
Ø 32
Ø 22
L1
G3/8
Ø 32
L1
IE/FP-3/01-2017 53
Sect. III - Pumps
P 1 (1) ** /* Accessories for pumps group 1
Ø 5.5
Soft start valve - on hole
/D VAMS0404001 T
auxiliary outlet Ø 0.4 mm P T
12.5
54 IE/FP-3/01-2017
Sect. IV - Tanks / Sect. V - Tubes kit
Tank (S = with tank and tubes kit; G = only tubes kit, without tank; OMIT if without tank and without tubes kit)
Capacity liters
Features (material and construction)
Mounting position: (H = horizontal; V = vertical)
Variants (00 = standard, no variant) - OMIT if with tubes kit
Orientation - OMIT if with tubes kit in vertical mounting position
End section IV and V
FP ........ * ** * (*) ** /* -
(*) ** *
** Liters * Dimensions (mm) Material Page Page
Mounting Variants Orientation
(H) 00
01 1 A Ø 123 - L 141 Sheet steel 56
(V) 00
(H) 00
1,5 G 130x140 - L 135 Polyethylene 65
(V) 00
02
(H) 00
2 A Ø 123 - L 200 Sheet steel 56
(V) 00
(H) 00
2,5 G 130x140 - L 235 Polyethylene 65
(V) 00
03
(H) 00
3 A Ø 123 - L 330 Sheet steel 56
(V) 00
(H) 00
4 G 130x140 - L 295 Polyethylene 65
(V) 00
04
(H) 00
4 L 180 - L 210 Polyethylene 66
(V) 00
(H) 00-01-02-03-04
5 B Ø 175 - L 246 Sheet steel 57
(V) 00
(H) 00
05 5 C Ø 200 - L 210 Sheet steel 58
(V) 00
(H) 00
5 F 180 - L 240 Polypropylene 64
(V) 00
(H) 00-04
06 6 B Ø 175 - L 308 Sheet steel 57
(V) 00
/1(std)
IV
7 E 154x188 - L 299 Sheet steel (V) 00-01 60
(H) 00
/2
69 V
7 F 180 - L 308 Polypropylene 64 /3
(V) 00
/4
07 (H) 00
7 L 180 - L 310 Polyethylene 67
(V) 00
(H) 00
7 M 180 - L 335 Polietilene 68
(V) 00
(H) 00-04
8 B Ø 175 - L 370 Sheet steel 57
(V) 00
08
(H) 00
8 C Ø 200 - L 306 Sheet steel 58
(V) 00
(H) 00
E 230x130 - L 350 Sheet steel 61
09 9 (V) 00
L 180 - L 370 Polietilene (V) 00 67
(H) 00
10 C Ø 200 - L 373 Sheet steel 58
(V) 00
(H) 00
10 10 D Ø 217 - L 273 Sheet steel 59
(V) 00
(H) 00
10 L 180 - L 410 Polyethylene 67
(V) 00
(H) 00
12 12 D Ø 217 - L 370 Sheet steel 59
(V) 00
14 14 E 255x193 - L 366 Sheet steel (V) 00-01 62
(H) 00-01
25 25 E 250x255 - L 436 Sheet steel 63
(V) 00-01
IE/FP-4-5/06-2017 55
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Tanks Ø 123 - Sheet steel, capacity 1-2-3 liters - Horizontal mounting (black painted)
Capacity (liters) 37
Tank fixing (49149800)
Variant (1) L Tank
Mounting
Capacity
Features
Nominal
kit
Usable
(mm) (with plug)
(screws and O-Ring)
Full
Ø 123
01 141 1 1.0 0.7 90310000
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
* ** * (V) ** * - Tanks Ø 123 - Sheet steel, capacity 1-2-3 liters - Vertical mounting (black painted)
(49149800)
Capacity (liters)
101
Tank fixing
L Tank
Variant (1)
Mounting
Capacity
Features
Nominal
IV kit
Usable
V
01 141 1 0.9 0.7 90310009 (60502700)
L
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
56 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Tanks Ø 175 - Sheet steel, capacity 5-6-8 liters - Horizontal mounting (black painted)
Capacity (liters)
51 (49149800)
Tank fixing
Variant (1) L Tank
Mounting
Capacity
Features
Nominal
kit
Usable
(mm) (with plugs)
(screws and O-Ring)
Full
Ø 175
05 246 5 4.7 4.5 90310003
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
05 90310003 05 90310149 05 90310134 05 90310176
06 B (H) 01 06 B (H) 02 06 B (H) 03 90310062 06 B (H) 04
08 08 08 90310069 08
* ** * (V) ** * - Tanks Ø 175 - Sheet steel, capacity 5-6-8 liters - Vertical mounting (black painted)
IV
Features
Nominal
kit
Usable
V
05 246 5 4.3 4.1 90310012
L
(60502700)
06 B (V) 00 308 6 5.8 5.5 90310013 17010080
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
IE/FP-4-5/06-2017 57
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Tanks Ø 200 - Sheet steel, capacity 5-8-10 liters - Horizontal mounting (black painted)
Capacity (liters)
Tank fixing (49149800)
Variant (1) L Tank
Mounting
Capacity
L
Features
Nominal
kit
Usable
(mm) (with plugs)
(screws and O-Ring)
Full
Ø 200
05 205 5 5.3 5.0 90310425
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
05 90310453
08 C (H) 03 90310443
10 90310483
(49107500)
(R78100021)
* ** * (V) ** * - Tanks Ø 200 - Sheet steel, capacity5-8-10 liters - Vertical mounting (black painted)
Capacity (liters)
(49149800)
Tank fixing
L Tank
Variant (1)
Mounting
Capacity
IV
Features
Nominal
kit
Usable
(R78100021)
V
L
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
58 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Tanks Ø 217 - Sheet steel, capacity10-12 liters - Horizontal mounting (black painted)
220 (12 liters)
Capacity (liters) Ø 11
(12 liters)
Tank fixing
Variant (1) L Tank
Mounting
Capacity
Features
Nominal
kit
(12 liters)
Usable
(mm) (with plugs)
(screws and O-Ring)
150
Full
10 273 10 8 7.6 90310006
D (H) 00 17010080 72
(49105800)
12 370 12 12 11 90310058
(1 ) Variant - OMIT if without tank but with tubes kit
Ø 217
81
L
* ** * (V) ** * - Tanks Ø 217 - Sheet steel, capacity10-12 liters - Vertical mounting (black painted)
(491105800)
Capacity (liters) 167
Tank fixing
L Tank
Variant (1)
Mounting
Capacity
IV
Features
Nominal
kit
Usable
V
10 273 10 7 6.8 90310029 (MEG5121200)
L
D (V) 00 17010080
12 370 12 10.3 10.1 90310100
(1 ) Variant - OMIT if without tank but with tubes kit
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
IE/FP-4-5/06-2017 59
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (V) ** * - Rectangular tanks - Sheet steel, capacity 7 liters - Vertical mounting (black painted)
(49154200)
Capacity (liters)
Tank fixing
112
Variant (1) L Tank
Mounting
97
Capacity
Features
Nominal
kit
Usable
(mm) (with plugs)
200
(screws and O-Ring)
Full
88
22
07 E (V) 00 299 7 5.5 5.1 90310014 17010080 (49154200)
215,5
11 N°4
(1 ) Variant - OMIT if without tank but with tubes kit
37
178
154
45
62,5
7 80 183
L
(..) spare parts
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
07 E (V) 01 90310036
(49107500)
(49154200)
IV
V
60 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Rectangular tanks - Sheet steel, capacity 9 liters - Horizontal mounting (black painted)
12
Tank fixing
Variant (1) L Tank (R78100021)
Mounting
Capacity
Features
Nominal
kit
Usable
(mm) (with plugs)
(screws and O-Ring)
Full
230
93
09 E (H) 00 350 9 9 8 90310142 17010080
25 211
22
(1 ) Variant - OMIT if without tank but with tubes kit
130
133
22
L
(..) spare parts
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
* ** * (V) ** * - Rectangular tanks - Sheet steel, capacity 9 liters - Vertical mounting (black painted)
12
Tank fixing
L Tank
Variant (1)
Mounting
Capacity
IV
Features
Nominal
kit
130
133
Usable
22
(screws and O-Ring)
Full
V
(R78100021)
211 25
22
236
IE/FP-4-5/06-2017 61
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (*) ** * - Rectangular tanks - Sheet steel, capacity 14 liters - Vertical mounting (black painted)
Capacity (liters)
(49149800)
12
Tank fixing
Variant (1) L Tank
Mounting
Capacity
Features
Nominal
kit
Usable
(mm) (with plugs)
(screws and O-Ring)
Full
219
193
22
14 E (V) 00 366 14 14 13 90310045 17010080
(49154200)
L
(1 ) Variant - OMIT if without tank but with tubes kit
265
220
37
91
277.5
300
94
20
11
(..) spare parts 75 73
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
14 E (V) 01 90310046
(49107500)
(49154200)
IV
V
62 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (*) ** * - Rectangular tanks - Sheet steel, capacity 25 liters - Horizontal mounting (black painted)
19 46 (49118000)
Capacity (liters)
Tank fixing (20022600)
Variant (1) L Tank
105 183.5
Mounting
Capacity
Features
Nominal
kit
Usable
(mm) (with plugs)
(screws and O-Ring)
255
Full
35
(25)
25 E (H) 00 436 25 22 21 90310060 17010080 16.5 n°4
46
200
250
(1 ) Variant - OMIT if without tank but with tubes kit
60
L (25)
(16)
474 (16)
506
(49120600)
(20022600)
* ** * (*) ** * - Rectangular tanks - Sheet steel, capacity 25 liters - Vertical mounting (black painted)
(49118000) 46
33.5
100
26
Capacity (liters)
Tank fixing
L Tank
Variant (1)
Mounting
Capacity
IV
Features
Nominal
kit
Usable
255
(screws and O-Ring)
Full
35
V
(25)
90310071 16.5 n°4
25 E (V) 00 436 25 25 22 17010080 (20022600)
46
200
250
L (25)
(16)
474 (16)
506
(49120600)
(20022600)
IE/FP-4-5/06-2017 63
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Square polypropylene tanks capacity 5-7 liters - Horizontal mounting
Capacity (liters)
Tank fixing
Variant (1) L Tank (49138700)
Mounting
Capacity
Features
Nominal
kit
Usable
(mm) (with plug, brackets, nuts)
(screws and O-Ring)
Full
105
180
190
05 242 5 5.4 4.5 90310313
90
F (H) 00 17010083
L
Operating temperature -10°C ÷ +60°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts
(49138700)
Capacity
Features
Nominal
kit
Usable
L
05 242 5 5.4 4.5 90310313
F (V) 00 17010083
07 306 7 7.4 6.5 90310289
(..) spare parts
Operating temperature -10°C ÷ +60°C - (1 ) Variant - OMIT if without tank but with tubes kit
IV
V
64 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Square polyethylene tanks capacity 1.5-2.5-4 liters - Horizontal mounting
Nominal
kit collar Ø123
Usable
(mm) (with plugs, clamp, nuts)
(screws and O-Ring)
104.5
Full
94
MAX
140
02 135 1.5 1.3 1 90310491
70
MIN
MAX
MIN
03 G (H) 00 235 2.5 2.5 2 90310484 17010081
L 130
04 295 4 3.4 2.5 90310422
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
IV
Features
Nominal
V
MAX
MIN
MAX
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
IE/FP-4-5/06-2017 65
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Square polyethylene tanks capacity 4 liters - Horizontal mounting
Nominal
kit collar Ø123 (V60513005)
Usable
(mm) (with plugs, clamp, nuts)
(screws and O-Ring)
Full
119
104.5
MAX
95
MAX
180
90.5
85
MIN
MAX
MIN
MIN
L 180
(49154200)
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
Capacity (liters)
(49153500)
Tank fixing
L Tank
Variant (1)
Mounting
Capacity
IV
Features
Nominal
MAX
V
MIN
MAX
L
MIN
MAX
MIN
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
04 L (V) 01 90310433
(49138700)
MAX
MIN
MAX
MIN
MAX
MIN
66 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (*) ** * - Square polyethylene tanks capacity 7-10 liters - Horizontal mounting
Nominal
kit collar Ø123 35
Usable
(mm) (with plugs, clamp, nuts)
(screws and O-Ring)
Full
102.5
119
MAX
95
MAX
180
67
07 310 7 6.7 5.5 90310330
85
MIN
MAX
MIN
MIN
L (H) 00 17010081 L 20 180
10 410 10 8.7 7.5 90310339
(V60513005)
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts
Nominal
MIN
MAX
Usable
MIN
MAX
07 310 7 6.7 6 90310403
MIN
L (V) 00 17010081
10 410 10 9.8 9 90310338
(V60513005) (49154200)
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts
IV
V
(49153500)
* ** * (*) ** * - Square polyethylene tanks capacity 9 liters - Vertical mounting 102
Capacity (liters)
Tank fixing
L Tank
Variant (1)
Mounting
Capacity
Features
Nominal
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (V60513005)
180
85 95
180
IE/FP-4-5/06-2017 67
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Special square polyethylene tanks capacity 7 liters - Horizontal mounting
Capacity (liters)
Tank fixing
Variant (1) L Tank
Mounting
(49155600)
Capacity
Features
Nominal
kit collar Ø123
Usable
(mm) (with plugs, clamp, nuts)
(screws and O-Ring)
Full
MAX
MIN
113
122
MAX
180
07 M (H) 00 335 7 7.3 6.6 90310380 17010081
67
MIN
L 180
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
IV
Features
Nominal
V
MAX
MIN
MAX
L
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
68 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (*) ** /* - Tanks orientation according to the mounting position
/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Horizontal
A A
B
S ** (H)
C A
D
A
(1)
/* Orientation
For tanks (*) Mounting position
/1 (standard)
Horizontal
S 09 E (H)
/* Orientation
For tanks (*) Mounting position
/1 (standard)
Horizontal
IV
A
V
S 25 E (H)
/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Horizontal
F A
S ** G (H)
L A
(1)
IE/FP-4-5/06-2017 69
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (*) ** /* - Tanks orientation according to the mounting position
/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Vertical
A
B
C
S ** D (V)
F A A A A
G
L
(2)
/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Vertical
S 07 E (V)
A A A A
(1)
/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Vertical
IV
V
09
S E (V)
25 A A A A
(1)
/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Vertical
S 14 E (V)
A A A A
(1)
70 IE/FP-4-5/06-2017
Sect. VI - DC Motors
Motor
Voltage
Power / Size
Version
Accessories
Orientation
End section VI
All motors are equipped with a transmission kit
(coupling and components for the assembly)
FP ........ M * ** (*) * /* -
For more details, features and performances DC motors, see catalog Dana code DOC00053.
IE/FP-6DC/04-2017 71
Sect. VI - DC Motors
Motors: 12 VDC 350 W / 24 VDC 400 W (permanent magnets)
Voltage W A rpm Nm S2 min S3% IP IC Ø mm Code (
)
M 2 GA (1) * /* 12 VDC 350 40 3300 1.0 10 35 54 F 80 25021400
M 4 GB (1) * /* 24 VDC 400 30 3100 1.2 5 20 54 F 80 25021500
IP protection level becomes effective after installationon on power pack.
(
) Motor without accessories
7 n.2
* Description
Ø 80
101
Ø 80
0 Without accessories
6.40
M6 n.2
7 n.2
M * ** (*) * /* - Accessories (page 75)
VI * Description
Ø 80
101
Ø 80
DC 0 Without accessories
6.40
For more details, features and performances DC motors, see catalog Dana code DOC00053.
72 IE/FP-6DC/04-2017
Sect. VI - DC Motors
Motors: 12 VDC 1500 W / 24 VDC 2000 W (wound field compound)
Voltage W A rpm Nm S2 min S3% IP IC Ø mm Code (
)
M 2 AA (1) * /* 12 VDC 1500 225 2500 5.5 1 5 54 F 115 25022200
M 4 AB (1) * /* 24 VDC 2000 150 2250 8 2 5 54 F 115 25022300
IP protection level becomes effective after installationon on power pack.
(
) Motor without accessories
0 Without accessories
Ø98.3
Ø15
6.4
Ø112
Ø35
D Ventilation
12.3 MAX 173
1/4-20 UNC-2A
91
F Ventilation + Starting switch
9.1 133
VI
Ø15
M8
6.4
DC
D1E1
90.4
* Description
A2E2
C Thermal protection
For more details, features and performances DC motors, see catalog Dana code DOC00053.
IE/FP-6DC/04-2017 73
Sect. VI - DC Motors
Motors: 12 VDC 1600 W / 24 VDC 2200 W (wound field serie)
Voltage W A rpm Nm S2 min S3% IP IC Ø mm Code (
)
M 2 GN (1) * /* 12 VDC 1600 220 2600 6 4 8 54 F 115 25022600
M 4 GP (1) * /* 24 VDC 2200 140 2600 6 2 7.5 54 F 115 25022700
IP protection level becomes effective after installationon on power pack.
(
) Motor without accessories
8.4 121.2
M * ** (*) * /* - Accessories (page 75)
M8
* Description
6.43
Ø15
M5 n°2
Ø114.3
Ø35
0 Without accessories
90.4
M5 n°2
Ø125
102
FB
GJ
8
D Ventilation
28.5 207.5 (M4FB) M6
43 200 (M4GJ) F Ventilation + Starting switch
For more details, features and performances DC motors, see catalog Dana code DOC00053.
74 IE/FP-6DC/04-2017
Sect. VI - DC Motors
M * ** (*) C /* - Accessory: Thermal protection
Thermal protection Ø
Code Ø mm For motors
90340009 16 M2EN - M4ES
182.5
72
64.5
57.3 Female Faston 5
Female Faston 5 29
6.3-08 N.2
M8 N.2
6.3-08 N.2 20
M6 N.2
Ø 54.5
Ø 40
26
21
For more details, features and performances DC motors, see catalog Dana code DOC00053.
9 (N°4) 9 (N°4)
VI
5
118
118
DC
5
* Code (•) VDC For motors * Code (•) VDC For motors
D KIT09008.061 12 M2AA D KIT09008.029 24 M4FB
G KIT09008.062 12 M2AA + thermal protecion (•) Complete kit with all assembly components (motor, transmission kit, etc).
D KIT09008.031 24 M4AB
G KIT09008.063 24 M4AB + thermal protecion
For more details, features and performances DC motors, see catalog Dana code DOC00053.
IE/FP-6DC/04-2017 75
Sect. VI - DC Motors
M * ** (*) * /* - Motor orientation
Std
/4 /2
/3
VI
DC
76 IE/FP-6DC/04-2017
Sect. VI - AC Motors
Motor
Phases
Poles
Size
Power range
Version
Orientation
End section VI
FP ........ M * * * * (*) /* -
Power range
* Phases * Poles * Size * Page (*) Version /* Orientation Page
Power Voltage
L 71 A 0.37 kW 230 Vac 50 Hz 78
L 71 B 0.55 kW 230 Vac 50 Hz 78
S 71 A 0.75 kW 230 Vac 50 Hz 80
S 71 B 1.10 kW 230 Vac 50 Hz 80
2 M 80 A 0.75 kW 230 Vac 50 Hz 78
M 80 B 1.10 kW 230 Vac 50 Hz 78
N 90 A 1.50 kW 230 Vac 50 Hz 78
N 90 B 2.20 kW 230 Vac 50 Hz 78
P 100 A 3.00 kW 230 Vac 50 Hz 78
Single
M L 71 A 0.25 kW 230 Vac 50 Hz 78
phase
L 71 B 0.37 kW 230 Vac 50 Hz 78
S 71 C 0.85 kW 230 Vac 50 Hz 80
M 80 A 0.55 kW 230 Vac 50 Hz 78
M 80 B 0.75 kW 230 Vac 50 Hz 78
4
N 90 A 1.10 kW 230 Vac 50 Hz 78
N 90 B 1.50 kW 230 Vac 50 Hz 78
V 90 A 1.80 kW 230 Vac 50 Hz 81
V 90 B 3.00 kW 230 Vac 50 Hz 81
P 100 A 2.20 kW 230 Vac 50 Hz 78
R 63 A 0.18 kW 230/400 Vac 50 Hz 79
R 63 B 0.25 kW 230/400 Vac 50 Hz 79
L 71 A 0.37 kW 230/400 Vac 50 Hz 79
L 71 B 0.55 kW 230/400 Vac 50 Hz 79
/1
S 71 A 0.75 kW 230/400 Vac 50 Hz 80
/2
S 71 B 1.10 kW 230/400 Vac 50 Hz 80 (1) Std Std 82
/3
M 80 A 0.75 kW 230/400 Vac 50 Hz 79
2 /4
M 80 B 1.10 kW 230/400 Vac 50 Hz 79
T 80 A 2.70 kW 230/400 Vac 50 Hz 81
T 80 B 2.70 kW 230/400 Vac 50 Hz 81
79
N
N
90
90
A
B
1.50 kW 230/400 Vac 50 Hz
2.20 kW 230/400 Vac 50 Hz 79
VI
P 100 A 3.00 kW 230/400 Vac 50 Hz 79
AC
P 112 B 4.00 kW 230/400 Vac 50 Hz 79
Three R 63 A 0.12 kW 230/400 Vac 50 Hz 79
T
phase R 63 B 0.18 kW 230/400 Vac 50 Hz 79
L 71 A 0.25 kW 230/400 Vac 50 Hz 79
L 71 B 0.37 kW 230/400 Vac 50 Hz 79
S 71 A 0.75 kW 230/400 Vac 50 Hz 80
M 80 A 0.55 kW 230/400 Vac 50 Hz 79
M 80 B 0.75 kW 230/400 Vac 50 Hz 79
T 80 A 2.20 kW 230/400 Vac 50 Hz 81
4
T 80 B 2.20 kW 230/400 Vac 50 Hz 81
T 80 C 2.20 kW 230/400 Vac 50 Hz 81
T 80 D 3.00 kW 230/400 Vac 50 Hz 81
N 90 A 1.10 kW 230/400 Vac 50 Hz 79
N 90 B 1.50 kW 230/400 Vac 50 Hz 79
P 100 A 2.20 kW 230/400 Vac 50 Hz 79
P 100 B 3.00 kW 230/400 Vac 50 Hz 79
P 112 C 4.00 kW 230/400 Vac 50 Hz 79
Motors supplied with all assembly components (transmission kit, coupling, etc).
IE/FP-6AC/04-2017 77
Sect. VI - AC Motors
L2
H1
D1
D2
L1
Cable gland
Power range Adapter
metric thred
D1 D2 H1 L1 Screw Single Transmission kit
Phases
Power
UNI L2
Poles
kW 5931
M M 2 L A (1) 2 2 71 14 148 115 208 0.37 230 Vac 50 Hz 54 F Si 20-25 61000700 M6x20 19.5 M12E2000 KIT08019.011 (Gr.05)
M M 2 L B (1) 2 2 71 14 148 115 208 0.55 230 Vac 50 Hz 54 F Si 20-25 61000700 M6x20 19.5 M12F2000 KIT08019.012 (Gr.1)
M M 2 M A (1) 2 2 80 19 170 126 234 0.75 230 Vac 50 Hz 54 F Si 20-25 61000800 M6x20 30.4 M13G2000 KIT08019.013 (Gr.05)
M M 2 M B (1) 2 2 80 19 170 126 234 1.10 230 Vac 50 Hz 54 F Si 20-25 61000800 M6x20 30.4 M13H2000 KIT08019.014 (Gr.1)
M M 2 N A (1) 2 2 90 24 185 142 247 1.50 230 Vac 50 Hz 54 F Si 20-25 61000900 M8x21 40.4 M14L2000 KIT08019.015 (Gr.05)
M M 2 N B (1) 2 2 90 24 185 142 272 2.20 230 Vac 50 Hz 54 F Si 20-25 61000900 M8x21 40.4 M14N2000 KIT08019.016 (Gr.1)
KIT08019.017 (Gr.05)
M M 2 P A (1) 2 2 100 28 210 155 310 3.00 230 Vac 50 Hz 54 F Si 25-32 61001000 M8x28 75 M15P2000
KIT08019.018 (Gr.1)
M M 4 L A (1) 2 4 71 14 148 115 208 0.25 230 Vac 50 Hz 54 F Si 20-25 61000700 M6x20 19.5 M12D4000 KIT08019.011 (Gr.05)
M M 4 L B (1) 2 4 71 14 148 115 208 0.37 230 Vac 50 Hz 54 F Si 20-25 61000700 M6x20 19.5 M12E4000 KIT08019.012 (Gr.1)
M M 4 M A (1) 2 4 80 19 170 126 234 0.55 230 Vac 50 Hz 54 F Si 20-25 61000800 M6x20 30.4 M13F4000 KIT08019.013 (Gr.05)
M M 4 M B (1) 2 4 80 19 170 126 234 0.75 230 Vac 50 Hz 54 F Si 20-25 61000800 M6x20 30.4 M13G4000 KIT08019.014 (Gr.1)
M M 4 N A (1) 2 4 90 24 185 142 247 1.10 230 Vac 50 Hz 54 F Si 20-25 61000900 M8x21 40.4 M14H4000 KIT08019.015 (Gr.05)
M M 4 N B (1) 2 4 90 24 185 142 272 1.50 230 Vac 50 Hz 54 F Si 20-25 61000900 M8x21 40.4 M14L4000 KIT08019.016 (Gr.1)
VI
KIT08019.017 (Gr.05)
M M 4 P A (1) 2 4 100 28 210 155 310 2.20 230 Vac 50 Hz 54 F Si 25-32 61001000 M8x28 75 M15N4000
KIT08019.018 (Gr.1)
AC
(•)= Approximate dimensions
78 IE/FP-6AC/04-2017
Sect. VI - AC Motors
L2
H1
D1
D2
L1
Cable gland
Power range Adapter
metric thred
D1 D2 H1 L1 Power Screw Single Transmission kit
Phases
UNI L2
Poles
kW 5931
M T 2 R A (1) 3 2 63 11 125 95 189 0.18 230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31C2000 KIT08019.009 (Gr.05)
M T 2 R B (1) 3 2 63 11 125 95 189 0.25 230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31D2000 KIT08019.010 (Gr.1)
M T 2 L A (1) 3 2 71 14 148 115 208 0.37 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32E2000 KIT08019.011 (Gr.05)
M T 2 L B (1) 3 2 71 14 148 115 208 0.55 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32F2000 KIT08019.012 (Gr.1)
M T 2 M A (1) 3 2 80 19 170 126 234 0.75 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33G2000 KIT08019.013 (Gr.05)
M T 2 M B (1) 3 2 80 19 170 126 234 1.10 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33H2000 KIT08019.014 (Gr.1)
M T 2 N A (1) 3 2 90 24 185 142 247 1.50 230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34L2000 KIT08019.015 (Gr.05)
M T 2 N B (1) 3 2 90 24 185 142 272 2.20 230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34N2000 KIT08019.016 (Gr.1)
M T 2 P A (1) 3 2 100 28 210 155 310 3.00 230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75 M35P2000 KIT08019.017 (Gr.05)
M T 2 P B (1) 3 2 112 28 225 182 325 4.00 230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75 M36Q2000 KIT08019.018 (Gr.1)
M T 4 R A (1) 3 4 63 11 125 95 189 0.12 230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31B4000 KIT08019.009 (Gr.05)
M T 4 R B (1) 3 4 63 11 125 95 189 0.18 230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31C4000 KIT08019.010 (Gr.1)
M T 4 L A (1) 3 4 71 14 148 115 208 0.25 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32D4000 KIT08019.011 (Gr.05)
M T 4 L B (1) 3 4 71 14 148 115 208 0.37 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32E4000 KIT08019.012 (Gr.1)
M T 4 M A (1) 3 4 80 19 170 126 234 0.55 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33F4000 KIT08019.013 (Gr.05)
VI
M T 4 M B (1) 3 4 80 19 170 126 234 0.75 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33G4000 KIT08019.014 (Gr.1) AC
M T 4 N A (1) 3 4 90 24 185 142 247 1.10 230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34H4000 KIT08019.015 (Gr.05)
M T 4 N B (1) 3 4 90 24 185 142 272 1.50 230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34L4000 KIT08019.016 (Gr.1)
M T 4 P A (1) 3 4 100 28 210 155 310 2.20 230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75 M35N4000
KIT08019.017 (Gr.05)
M T 4 P B (1) 3 4 100 28 210 155 310 3.00 230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75 M35P4000
KIT08019.018 (Gr.1)
M T 4 P C (1) 3 4 112 28 225 182 325 4.00 230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75 M36Q4000
(•)= Approximate dimensions
IE/FP-6AC/04-2017 79
Sect. VI - AC Motors
8.25 max
5.32 max
(126)
Ø35
6.40
(Ø115)
118
10
Ø1
n°4 - Ø9
118 (175)
Cable gland
Power range
metric thred
Single
Phases
kW
8.25 max
3.15 max
(117)
Ø35
6.40
(Ø115)
118
0
Ø 11
VI
n°4 - Ø9
118 (175)
AC
Three-phase motors 2-4 Poles - 230/400 Vac 50Hz - Direct fixing
Cable gland
Power range
metric thred
Single
Phases
kW
80 IE/FP-6AC/04-2017
Sect. VI - AC Motors
With fan Without fan
(126)
(126)
Ø20
Ø20
7.5 7.5
(Ø154)
(Ø154)
118
118
0 0
Ø 11 Ø 11
9.5
n°4 - Ø9
9.5
n°4 - Ø9
Cable gland
Power range
metric thred
Single
Phases
kW
Ø25
7.5
(Ø175)
VI
Ø110
118
AC
n°4 - Ø9
9.5
118 (280) max
Power range
metric thred
Single
Phases
kW
IE/FP-6AC/04-2017 81
Sect. VI - AC Motors
M * * * * (*) /* - Motor orientation
/3
VI
AC
82 IE/FP-6AC/04-2017
Sect. VII - Transmission kit DC motors
Transmission kit (only for motors on the catalog)
Type
End section VII
Specify the transmission kit whether you requested the joint and
accessories assembly (without motor).
FP ........ T ** -
Transmission kit
** For DC motors
Code Pump L Ø
Ø
KIT08019.000 Gr. 0.5 63.3 14 GA (350 W - Ø 80 - Page 72)
GC (700 W - Ø 80 - Page 72) L
01
GB (400 W - Ø 80 - Page 72)
KIT08019.001 Gr. 1 46.9 14 GD (800 W - Ø 80 - Page 72)
Transmission kit
** For DC motors
Code Pump L Ø
AA (1500 W - Ø 115 - Page 73)
Ø
KIT08019.002 Gr. 0.5 64.5 14 EN (1600 W - Ø 115 - Page 73)
AB (2000 W - Ø 115 - Page 73) L
02
ES (2200 W - Ø 115 - Page 73)
KIT08019.003 Gr. 1 48.2 14 GN (1600 W - Ø 115 - Page 74)
GP (2200 W - Ø 115 - Page 74)
32
Transmission kit
Ø
** For DC motors
Code Pump L Ø
GJ (3000 W - Ø 125 - Page 74) L
03 KIT08019.004 Gr. 1 45.4 20
FB (3000 W - Ø 125 - Page 74)
28.5
Note: in ventilated motors (accessory “D” page 74) the transmission is included
in the kit ventilation
VII
IE/FP-7/00-2017 83
Sect. VII - Transmission kit AC motors
Transmission kit (only for motors on the catalog)
Type
End section VII
Specify the transmission kit whether you requested the joint and
accessories assembly (without motor).
FP ........ T ** -
19.5
Transmission kit For AC motors
** Page
Code Pump L Ø L1 Z Ref. Size
Ø 11
Ø
KIT08019.009 Gr. 0.5 47.1 14 30 62.7
63 L
1R R 79 L1
(B14) Z
KIT08019.010 Gr. 1 30.6 20 30 42.8
19.5
Ø 14
Code Pump L Ø L1 Z Ref. Size
Ø
KIT08019.011 Gr. 0.5 47.1 14 26.5 42 78
71 L L1
1L L
(B14) Z
KIT08019.012 Gr. 1 30.7 20 26.5 42 79
30.4
Ø 19
Code Pump L Ø L1 Z Ref. Size Ø
40.4
75
Transmission kit For AC motors
** Page
Ø 28
84 IE/FP-7/00-2017
Sect. VIII - Blocks and CETOP valves
Standard blocks
Mounting position
Accessory
Separation line
In the order confirmation the code of the “Blocks and CETOP valves”
will be converted into a type Jxxxx (xxxx = sequential number).
4 (V60403005)
136.5
4
108.5
3
3 (V60403005)
2 (V60403004) 4 3 2 1 (V60403004)
95
2 4 3 2 1
1
1
Blocks orthogonal to the axis Blocks orthogonal to the axis with Blocks parallel to the axis with Blocks parallel to the axis with
Except AC motors ref. size M-N-P heighten interface 90° heighten and interface 90°
For AC motors ref. size M-N-P Except AC motors ref. size P For AC motors ref. size P
The blocks can not be mounted with motors oriented in position “1” (DC motors, see page 76. AC motors, see page 82).
4 4
3 3
2 2
1 1
1 2 3 4 1 2 3 4
4
(V60403004)
VIII
Blocks orthogonal to the axis Blocks orthogonal to the axis with Blocks parallel to the axis with Blocks parallel to the axis with
Except AC motors ref. size M-N-P heighten interface 90° heighten and interface 90°
For AC motors ref. size M-N-P Except AC motors ref. size P For AC motors ref. size P
The blocks can not be mounted with motors oriented in position “1” - DC motors, see page 76. AC motors, see page 82.
IE/FP-9/04-2019 85
Sect. VIII - Blocks and CETOP valves
Block type
Accessory
Pressure relief valve setting on “A” line
Pressure relief valve setting on “B”line
CETOP valve
End section VIII
A
A2 (00) (0) (0) Middle parallel - Lateral ports G3/8” V60403010
49
P1 T1
80 A B
B
T1
.5 A
39
B
P1 P T
A3 (00) (0) (0) Middle parallel - Rear ports G3/8” V60403001
80 49
T1
55 P1
A
B2 (00) (0) (0) Middle series - Lateral ports G3/8” V60403011
49
P1 T1
80 A B
B
T1
.5 A
39
B P T
P1
B3 (00) (0) (0) Middle series - Rear ports G3/8” V60403003
49
80
P1 T1
A B
With pilot check valve on ”A” port .
E1 (00) (0) (0) Rear ports G1/4”
V60413002
P T
T1 P1 T1
55 P1
A B
With pilot check valve on ”B” port. A
E2 (00) (0) (0) V60413003
49
VIII 80
B P T
P1 T1
A B
With pilot check valve on ”A” and “B” ports.
E3 (00) (0) (0) Rear ports G1/4”
V60413001
P T
P1 - T1: thread, closing with plug G1/8” (Plug Q26622251 + Washer Q51435012)
86 IE/FP-9/04-2019
Sect. VIII - Blocks and CETOP valves
** (00) (..) (..) /***/ - Block type
49
With pressure relief valve on “A” port
(F) (0) Setting 110 ÷ 220 bar - Lateral ports G1/4”
1318830
80
B P T
With pressure relief valve on “A” port
(G) (0) Setting 220 ÷ 290 bar - Lateral ports G1/4”
1318831
49
A
With pressure relief valve on “B” port
(0) (F) Setting 110 ÷ 220 bar - Lateral ports G1/4”
1318834 80
B P T
With pressure relief valve on “B” port
(0) (G) Setting 220 ÷ 290 bar - Lateral ports G1/4”
1318835
49
A
With pressure relief valve on “A” and “B”
(F) (F) Setting 110 ÷ 220 bar - Lateral ports G1/4”
1318838 80
B P T
With pressure relief valve on “A” and “B”
(G) (G) Setting 220 ÷ 290 bar - Lateral ports G1/4”
1318839
P1 - T1: thread, closing with plug G1/8” (Plug Q26622251 + Washer Q51435012)
VIII
IE/FP-9/04-2019 87
Sect. VIII - Blocks and CETOP valves
Mounting kits
Mounting kit: blocks For No. blocks Code
1 V60513007
2 V60513008
Mounting position 0-2-3
3 V60513009
4 V60513010
1 V60513011
Mounting position 1 2 V60513012
(with heighten) 3 V60513013
4 V60513014
connectors supplied
with the valve (1)
01 C a b
P T
/002/ 12 VDC (L) ADC3E01CL001
02 C
a b
/004/ 12 VDC (L) ADC3E02CL001 P T
V60513015
/005/ 24 VDC (M) ADC3E03CM001 A B
03 C
VIII /006/ 12 VDC (L) ADC3E03CL001
a
P T
b
04 C a b
P T
/008/ 12 VDC (L) ADC3E04CL001
88 IE/FP-9/04-2019
Sect. IX - Accessories
Accessories (optional)
First accessory
Second accessory
FP ........ R * *
45,5
except orientation / 3
Tanks compatible
Kit
Standard foot, (galvanized sheet steel) (except for orientation / 3)
A (foot and screws):
thickness 2.5 mm (unassembled) S**A
n°4 Ø 9,5 17010075
S**B
S**C
S**G
S**L
For motors:
Kit M2EN
Protection device for DC motors (protectin, nut, M4ES
C (supplied assembled) tierods, washers):
17010048 With blocks, please add the
block code 91006000.000
Tanks compatible
(except for orientation / 3)
Kit
High foot, (galvanized sheet steel) thickness S**A
D (foot and screws):
2 mm (unassembled) S**B
n°4 Ø 9 17010053
S**C
S**D
S**F
S**G
S**L
101.6
Collar:
Ø 25000300
11
4
101.6
Ø 121
4 FORI M6 26
IX
F Without valves connectors
IE/FP-9/03-2017 89
Examples
Examples with FPA endhead
A B 5
A B 5TG FPA 0 F1 2DAAA+B 5TG -03 - ..
Cavity Code Description Page
Thread ports P-T G1/4”
- 0 13
(blocks interface)
2DAAA +B Pressure relief valve with check
2 valve (75 ÷ 220 bar) with screw
1 F1 14
and detachable closing, standard
1 setting 150 bar
B Piloted solenoid valve normally closed,
2DAAA
2 without emergency. Voltage 12 16
+B
VDC + Flow control valve 1.4 l/min
7 6 5 5TG Plug 18
7 6 6-7
Not specified, return lines 6 and 7
—
open
Combinations plugs on ports
A-B -03 20
(A= open; B= with plug)
- - End section —
90
Examples
Examples with FPC endhead
91
Examples
92
Examples
Examples with FPL endhead
93
Examples
Examples with FPE endhead
94
Note
95
Note
96
®
Sede legale: Via Luciano Brevini 1/A, 42124 Reggio Emilia - Italy
Tel: +39.0522.9281 - Fax: +39.0522.928300
www.dana.com/brevini - dana.re@dana.com