You are on page 1of 100

®

FP HYDRAULIC POWER PACK

Technical Catalogue
June
2019
Table of contents

Introduction ...................................................................................................... 2
Endhead configuration .................................................................................... 3
Power pack sections ...................................................................................... 7
i
Selection code ................................................................................................. 8
Endhead overall dimensions ....................................................................... 11
Cavities dimensions ...................................................................................... 12
Endhead choice ............................................................................................. 13

SELECTIONS FOR “FPA” POWER PACK ENDHEAD


Sect. I - FPA Cavity 1 ..................................................................................... 14
Sect. II - FPA Cavity 2 .................................................................................... 15
Sect. II - FPA Cavity 5 .................................................................................... 18
Sect. II - FPA Cavity 6-7 ................................................................................ 19
Sect. II - FPA Ports A-B ................................................................................. 20

SELECTIONS FOR “FPC” POWER PACK ENDHEAD


Sect. I - FPC Cavity 1 ..................................................................................... 21
Sect. II - FPC Cavity 2 .................................................................................... 22
Sect. II - FPC Cavity 3 .................................................................................... 25
Sect. II - FPC Cavity 4 .................................................................................... 28
Sect. II - FPC Cavity 5 .................................................................................... 31
Sect. II - FPC Cavity 6-7-8-9 .......................................................................... 32
Sect. II - FTC Ports A-B-C ............................................................................. 33

SELECTIONS FOR “FPL” POWER PACK ENDHEAD


Sect. I - FPL Cavity 1 ...................................................................................... 34
Sect. II - FPL Cavity 2 ..................................................................................... 35
Sect. II - FPL Cavity 3 ..................................................................................... 38
Sect. II - FPL Cavity 4 ..................................................................................... 41
Sect. II - FPL Cavity 7-8 ................................................................................. 44
Sect. II - FTL Ports A-B-C-D ......................................................................... 45

SELECTIONS FOR “FPE” POWER PACK ENDHEAD


Sect. I - FPE Cavity 1 ...................................................................................... 46
Sect. II - FPE Cavity 2 .................................................................................... 47
Sect. II - FPE Cavity 3 .................................................................................... 49
Sect. II - FPE Cavity 9 .................................................................................... 51
Sect. II - FTE Ports A-B-C-D ......................................................................... 52

ELECTIONS FOR ALL POWER PACK ENDHEADS


Sect. III - Pumps ............................................................................................. 53
Sect. IV - Tanks / Sect. V - Tubes kit .......................................................... 55
Sect. VI - DC Motors ...................................................................................... 71
Sect. VI - AC Motors ...................................................................................... 77
Sect. VII - Transmission kit DC motors ...................................................... 83
Sect. VIII - Blocks and CETOP valves ........................................................ 85
Sect. IX - Accessories .................................................................................. 89

Examples ......................................................................................................... 90

© 2019 Dana Motion Systems Italia S.r.l. all rights reserved. Hydr-App, SAM Hydraulik, Aron, Brevini Hydraulics, BPE Electronics, VPS Brevini, OT Oiltechnology,
logos are trademarks or are registered trademarks of Dana Motion Systems Italia S.r.l. or other companies Dana in Italy and other countries.
The technical features supplied in this catalogue are non binding and no legal action can be taken against such material. Dana will not be held responsible
for information and specifications which may lead to error or incorrect interpretations. Given the continuous technical research aimed at improved technical
features of our products, Dana reserves the right to make change that are considered appropriate without any prior notice. This catalogue cannot be reproduced
(in while or in part) without the prior written consent of Dana. This catalogue supersedes all previous ones.
Use of the products in this catalogue must comply with the operating limits given in the technical specifications. The type of application and operating
conditions must be assessed as normal or in malfunction in order to avoid endangering the safety of people and/or items.

IE/FP-INTRO/04-2017 1
Introduction
Operating pressure is controlled by the maximum pressure valve
and the type of pump used (in terms of performance) may be deter-
mined by the maximum pressure valve. Therefore, it is essential not
i to change the maximum pressure valve. If neccessary, contact our
technical service department.

Installation
1) The power pack must be mounted using the M10 holes on the endhead.
2) The power pack must not come into contact with sheet metal, protective
guards or any parts that may vibrate and transmit noise.
3) The ports on the endhead have been identified by the letters A-B -C. The
hydraulic connection must be made with fittings with cylindrical thread
and with copper or rubber sealing gaskets (O-rings).
4) After the electrical connections have been made, check the direction of
motor rotation by executing short pulses of 1 second each (max.): the mo-
tor must turn anti-clockwise, as shown in the figure.

A B C
OI
L
The FP series power pack is an easy-to-assemble, compact, electro-hydraulic
unit. With its versatility and modularity, it offers many combinations of
hydraulic circuits to suit various requirements of plant design. This catalogue
has been written to help the user choose the components for the power pack M
required for the specific application. However, the catalogue cannot foresee
all the combinations that may be executed, so in some cases it may be
necessary to consult our commercial engineering department. 82
For applications with very complex circuits, standard modular blocks for Cetop M10
valves and other special blocks can be installed on the power pack, or blocks
built to order can be included.
The tank must be filled with new mineral-based, ISO 6743/4 fluid: it is
A few applications: important to filter the fluid while filling the tank.
• Fork lifts
• Lifting platforms and beds
• Automotive lifts Symbols used in this catalog:
• Cranes for small trucks
Important data/information
• Snowplows
• Industrial automation (machine tools, food industry, textile industry)
Mounting endhead side
You can chose from a wide variety of components with the following
specifications: Ground floor

• Gear pumps - Group 0.5 / 1 - from 0.25 to 9.8 cc. Electrical connection boxes on AC motors
• DC motors, 12/24 V, light-duty service, from 0.35 to 3 Kw
• Single and triple-phase motors with power ratings of up to 4 Kw - in a Poles and/or starting relays on DC motors
standard version or built to the customer's specifications (with minimum
overall dimensions) Fill plug with breather and level stick
• Tanks in sheet steel with capacities of up to 25 litres
• Tanks in plastic with capacities of up to 10 litres Fill plug with breather

A fundamental part of the power pack is the endhead, which is made of die-cast Standard plug (closed)
aluminum alloy. The parts and dimensions of this component are shown below.
Standard oil fill plug
Operating limits
• Intermittent peak pressure: 290 bar (depending on pump type)
Fill plug with breather
• Maximum flow rate: 20 l/min
• Maximum operating temperature: Fill plug
80°C (with sheet steel tank)
70°C (with polyethylene tank) Fill plug with check valve
60°C (with polypropylene tank)
• Mineral-based hydraulic fluid: ISO 6743-4 (DIN 51524) Fill plug with back check
Minimum viscosity: 12 mm²/s
Drain plug with magnet
Maximum viscosity: 80 mm²/s
Maximum viscosity at start-up: 500 mm²/s Plug (or level stick) with visual indicator
• Minimum ambient temperature -15°C
• Maximum ambient temperature 40°C (with peaks of 50°C) Drain plug
• The validation of the endhead follows a life-test with 250 bar pulsed pres-
sure repeated for 100.000 cycles * Fields to be completed

2 IE/FP-INTRO/04-2017
Endhead configuration
Power pack endhead configuration

FPA i
5TG 5TH

2DA
+

2DB

2DC

2DD

2C

A B 5
2H
A1-B1-C1-D1

2 2FA
2 A2-B2-C2-D2

2Z*
A3-B3-C3-D3

1 1
2TC
K1

2TD
7 6
X1

2TE

2TF 7 6

2TK

7 6
Flow control valves

IE/FP-INTRO/04-2017 3
Endhead configuration
Power pack endhead configuration
2DA 3DD

i 2DB
FPC 3H

2DC 3FA

2DD 3FB

5
2C 5TG 5TH 3A

2H + 3B
3
+
3TC
2 2FA
9

2Z* 3TD

2TC 3TE

2TD 3TF
A B 5 C

2TE 3TK

2TF
2 3

A1-B1-C1-D1
2TK
4 1
A2-B2-C2-D2
4DA

8 7 6 9 A3-B3-C3-D3
4DB
1

4DC K1

8 7 6 9 9TL

4DD X1

4C 8 7 6 9

4H
4 Flow control valves (or plug for cavity 9)

4FA

4Z

4TE

4TF

4TK

4 IE/FP-INTRO/04-2017
Endhead configuration
Power pack endhead configuration
2DA 3DA

2DB
FPL 3DB
i
2DC 2TC 3DC

2DD 2TD 3DD

2 2C 2TE 3H

2H 2TF 3FA

2FA 2TK 3FB

3A 3
2Z*

3B

3TD
4DA A D B C

3TE
4DB

2 3 3TF
4DC

3TK
4DD
4 1

4C

8 7
4H

4
4B

8 7
A1-B1-C1-D1
4FA

A2-B2-C2-D2
4Z 8 7
Flow control valves A3-B3-C3-D3
4TE
1

4TF K1

4TK X1

IE/FP-INTRO/04-2017 5
Endhead configuration
Power pack endhead configuration

i FPE
(for directional control valves)

22D(1A) 2 4
S2 S1

3 1

22D(1B) 2 4 4 3 2

S2 S1 S1 S2 1

3 1

22D(1C) 2 4
S2 S1

3 1
3FA
22D(1D) 2 4
S2 S1

3 1
A D B C 3FB
2D(2A) 2 4 3
+
3 1
3TC

2D(2B) 2 4

2 3 9
3 1

2D(2C) 2 4

A1-B1-C1-D1

2 1
3 1

2D(2D) 2 4

A2-B2-C2-D2
3 1

2D(2E)
4 3 2
2 4 1

3 1
9 A3-B3-C3-D3

2D(3A) 2 4 1
3 1
K1
2D(3B) 2 4 9

3 1
X1
2D(3C) 2 4

3 1
9
2D(3D) 2 4
Flow control valves
3 1

2D(3E) 2 4

3 1

6 IE/FP-INTRO/04-2017
Power pack sections
VIII (J-K-W) VI (M)

II VII (T)
I

V (G) III (P)

IX (R)
IV (S)

With its great modularity, the FP series of power packs can create multiple SECTION IV - TANKS
configurations which satisfy requirements in a wide range of applications. This section is defined by the letter S.
To make it easier to choose components, the power pack is subdivided into Depending on the required features, select the reservoir from the list provided.
sections. If no Reservoir is required, and also no Suction / Return Kit is required, please
omit this section. If no Reservoir is required, but a Suction / Return Kit is
SECTION I - SERIE, FLANGE TYPE, VALVES ON CAVITY 1 required, please jump to Section V (defined by letter G).
FP Series Powerpacks are based on the Flange features.
The Flange is the core of the unit, on the flange are mounted all the valves, SECTION V - TUBES KIT (suction and return, only for tanks on the catalog)
the pump, the motor and the reservoir. This section is defined by the letter G.
The FP Flange is available in several Versions (with different tooling options). In order to define this Section, please select the Reservoir Type anyways.
The Flange Version must be chosen depending on the type of Hydraulic Circuit
Layout required. SECTION VI - MOTORS
Together with the Flange Version, it is required to select the Valves to be This section is defined by the letter M.
mounted in the Various Cavities. Depending on the Type of Hydraulic Circuit Layout to be realized, it is required
1 (Main Pressure Relief Valve). to Select the Motor Type. If no Motor is required, and no Transmission Kit is
required, please omit this section. If no Motor is required, but a Transmission
SECTION II - VALVES Kit is required, please jump to Section VII (defined by letter T).
Depending on the Type of Hydraulic Circuit Layout to be realized, it is required
to Select the Valves for each of the available Cavities. SECTION VII - TRANSMISSION KIT (only for motors on the catalog)
In order to correctly build up the Ordering Code, it is required to use the This section is defined by the letter T.
following procedure. Select the kit as per Table provided.
Peripheral Cavities (it is mandatory to mention all the Cavities in Numeral
Order): starting from Cavity 2, mention all the Cavities and the Valves, Plugs SECTION VIII - BLOCKS
or Fittings to be mounted in said Cavity. This section it is not mandatory, depending on the Type of auxiliary Block
Internal Cavities: normally connected to Tank (It is not mandatory to mention, required, definition Letter changes:
but if required it should be done in Numeral Order): starting from Cavity 6, J, Blocks with CETOP type of interface for Solenoid Valves;
mention all the Internal Cavities where a Valve (usually a Return Line Valve) is K, Bankable Valves Interface – Horizontal (Parallel to Unit Axis);
mounted, Selecting the Valve Type to be mounted in said Cavity. W, Bankable Valves Interface – Vertical (Perpendicular to Unit Axis);
Outputs, see description in the Table.
SECTION IX - ACCESSORIES
SECTION III - PUMPS His section it is not mandatory, is defined by the letter R
It is mandatory to mention this section, defined by the letter P. Check the available options in the list provided.
Depending on the required features, select the pump from the table provided. Accessories must be listed in Alphabetical Order.

IE/FP-INTRO/04-2017 7
Selection code
SECTION I - SERIE, ENDHEAD, VALVES ON CAVITY 1

i Power pack type


Endhead type
Thread ports
Pressure relief valve - Check valve - Plug
Setting type (or plug features)
Special setting pressure relief valve (omit if not required)

FP * * * * (...)

SECTION II - VALVES

Cavity 2
Type
Features
Optional flow control valve (omit if not required)
Cavity 3
Type
Features
Flow control valve can be combined with plug TC (omit if not required)
Cavity 4
Type
Features
Cavity 5
Plug
Features
Flow control valve can be combined with plug TG (omit if not required)
Return cavities 6-7-8-9
Optional flow control valve (or plug for cavity 9)
Combination plugs for ports
End section II

2 .. ** +* 3 .. ** +* 4 .. ** 5 T * +* 6 * 7 * 8 * 9 * - ** -

SECTION III - PUMPS

Pump
Pump group
Performance level
Nominal displacement
Accessories (omit if not required)
End section III

P * (*) ** / * -

8 IE/FP-INTRO/04-2017
Selection code
SECTION IV - TANKS / SECTION V - TUBES KIT

Section:
S = tank (with tubes kit) ; i
G = only with tubes kit, without tank;
OMIT if without tank and without tubes kit
Capacity liters
Features (material and construction)
Mounting position:
H = horizontal;
V = vertical
Variants
00 = standard, no variant;
OMIT if with tubes kit (section “G”)
Orientation
OMIT if with tubes kit in vertical mounting position (section “G”)
End section IV and V

* ** * (*) ** /* -

SECTION VI - MOTORS

DC motor
Voltage
Power / Size
Version
Accessories
0 = whitout accessories;
Orientation
End section VI

M * ** (*) * /* -

OR ..

AC motor
Phases
Poles
Size
Power range
Version
Orientation
End section VI

M * * * * (*) /* -

IE/FP-INTRO/04-2017 9
Selection code
SECTION VII - TRANSMISSION KIT (only for motors on the catalog)

i Transmission kit
Type
End section VII
Specify the transmission kit whether you requested the joint and
accessories assembly (without motor).
T ** -

SECTION VIII - BLOCKS

Blocks
Mounting position
Accessory
Separation line
Block type
Accessory
Pressure relief valve setting on “A” line
Pressure relief valve setting on “B” line
CETOP valve
End section VIII

J * (00) - ** (00) (..) (..) /***/ -

SECTION IX - ACCESSORIES

Accessories (optional)
First accessory
Second accessory

R * *

10 IE/FP-INTRO/04-2017
Endhead overall dimensions
Cavities on endhead: The number of cavities tooled identify the endhead type:
Endhead type
Cavity Thread There are three types of cavities:

A Ports
G1/4” (1)
FPA FPC FPL FPE
• • • •
- Peripheral cavities, which can be accessed externally
- Return cavities, inside of the tank.
i
G3/8” (2) - Ports
G1/4” (1)
B Ports • • • •
G3/8” (2)
G1/4” (1)
C Ports — • • •
G3/8” (2)
D Ports G1/4” (1) — — • • 82

22.5
1 Peripheral 3/4” 16 UNF • • • •

2 HOLES M10 (18)


2 Peripheral 3/4” 16 UNF • • • •
3 Peripheral 3/4” 16 UNF — • • •
4 Peripheral 3/4” 16 UNF — • • —
5 Peripheral (3) M16x1.5 • • — —
6 Return G3/8” • • — — POWER PACK FIXING SIDE
7 Return G3/8” • • • —
134
8 Return G3/8” — • • —
101.6 PUMP/TANK SIDE
9 Return G3/8” — • — •
1) blocks interface
2) available only for FPA - FPC endhead
3) the cavity 5 is not accessible with blocks mounted (section IX).
7 6 9

3 2
(FOR ATTACHING TANKS)
4 HOLES WITH Ø7

101.6
134
1 4

8
PORT SIDE

GROOVE FOR TANK


SEALING GASKET
(O-RING, 3.53x110.72)
A D B 5 (1) C
52
48.5 2 - M6 HOLES (10) WITH CENTER
DISTANCE OF 101.5
MOTOR SIDE
45 15.5
20°
WITH CENTER DISTANCE OF 91
4 HOLES 1/4-20 UNC (12)
Ø 98.3

Ø 120
Ø 110

Ø 35
Ø 80

Ø30

118
Ø32

10°

14.1 15.4 118


4 HOLES M8

The cavities (1-2-3-4-5) and the ports (A-B-C) are marked on the die-cast endhead. The dimensions on the drawing are the same for all endhead.

IE/FP-INTRO/04-2017 11
Cavities dimensions
Cavity Thread Drawing Cavity Filettatura Drawing
CD018013
i

Ø 16.4
Ø 26
1 Peripheral 3/4 16 UNF 5 Peripheral M16 x 1.5

Ø 14.5
Ø 15.8

Ø 12.7
M16x1.5
7.2

3/4-16 UNF
12
20.5
17.5
24.6
42.5
34 2
62.5 5

CD018009

G3/8
Ø 26

Peripheral
2 3/4 16 UNF 6 Return G 3/8
Ø 12.7
Ø 11.5

(FPA-FPC) 12 15
3/4-16 UNF

17.5 18.5

41

66.5

CD018001
Ø15.9
Ø27

G3/8
Peripheral
2 3/4 16 UNF 7 Return G 3/8
Ø 11.5

Ø 14.3
Ø 12.7

(FPE) 23
3/4-16 UNF

11.5
19.1 37
33.3
47.6
56

CD018014
G3/8
Ø 26

3 Peripheral 3/4 16 UNF 8 Return G 3/8


Ø 12.7

12 21
3/4-16 UNF

17.5 30

30.5

CD018014
G3/8
Ø 26

4 Peripheral 3/4 16 UNF 9 Return G 3/8


Ø 12.7

12 22
3/4-16 UNF

17.5 27

30.5

12 IE/FP-INTRO/04-2017
Endhead choice

Endhead type
Thread ports

FP * *

FP
A C L
A B 5 A B 5 C A D B C

2 2 3 2 3

1 4 1 4 1

7 6 8 7 6 9 8 7

A D B C

2 3
* Endhead type

* Ports Peripheral Return


A n. 2 (A - B) n. 3 (1 - 2 - 5) n. 2 (6 - 7)
1
C n. 3 (A - B - C) n. 5 (1 - 2 - 3 - 4 - 5) n. 4 (6 - 7 - 8 - 9)
L n. 4 (A - B - C - D) n. 4 (1 - 2 - 3 - 4) n. 2 (7 - 8)
E n. 4 (A - B - C - D) n. 3 (1 - 2 - 3) n. 1 (9)
9

* Thread ports

Ports thread Blocks


*
G1/4” G3/8” interface
0 YES YES
1 YES NO

Endhead codes
G1/4” G3/8”
FPA 78013010.000 78013011.000
FPC 78013014.000 78013015.000
FPL 78013022.000
FPE 78013016.000

IE/FP/00-2016 13
Sect. I - FPA Cavity 1
A B 5

Pressure relief valve - Check valve - Plug


Setting type (or plug features)
Special setting pressure relief valve (omit if not required)
2

FPA** * * (...)

I 7 6

FPA A B 5
A1
B1
C1
D1
A2
2 B2
C2
D2
A3
B3
C3
1 D3
K1

7 6

X1

* * (...) Pressure relief valve with check valve

Pressure STD setting (...) Special


* * Setting type Code Symbol Drawing
(bar) (bar) setting (bar)
1 Detachable closing CMPR04S00002
15 ÷ 50
D 2 15 ÷ 50 30 Non removable closing (1) CMPR04P00002
(5 to 5)
3 Plastic knob CMPR04M00002 1
1 Detachable closing CMPR04S01002
35 ÷ 110
E 2 35 ÷ 110 50 Non removable closing (1) CMPR04P01002
(5 to 5)
3 Plastic knob CMPR04M01002
2
1 Detachable closing CMPR04S02002
75 ÷ 220
F 2 75 ÷ 220 150 Non removable closing (1) CMPR04P02002
(5 to 5)
3 Plastic knob CMPR04M02002 3
1 Detachable closing CMPR04S03002
160 ÷ 290
G 2 160 ÷ 290 180 Non removable closing (1) CMPR04P03002
(10 to 10)
3 Plastic knob CMPR04M03002
1 = Supplied assembled. Unassembled, see accessories page 89

* * Check valve and plug

* * Description Code Symbol Drawing

K 1 Check valve - Opening pressure 0.5 bar CRI0400001

X 1 Plug R78150100

14 IE/FPA-1/04-2019
Sect. II - FPA Cavity 2
Cavity
Type
Features
Optional flow control valve (omit if not required)

FPA** ** (...) 2 .. ** +*

A B 5

2DA** +*
II
2
2DB** +* FPA

2DC** +*
1

2DD** +*
7 6

2C* +*

2H* +*

2FA*

2Z*

A B 5

2TC

2TD
2
G 1/4
2TE

2TF

G 1/4
7 6
2TK

G 1/4

Flow control valves

IE/FPA-2/04-2019 15
Sect. II - FPA Cavity 2
2 DA ** +* Piloted solenoid valves normally closed, without emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCASL003 + V86050002
AB Voltage 24 Vdc CRP0418NCASM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCASA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCASJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCASI003 + V86050002

II
2 DB ** +* Piloted solenoid valves normally open, with rotary emergency (1)
FPA
** Description Code (valve + connector) Symbol Drawing
AA Voltage 12 Vdc CRP0418NCAEL003 + V8605002
AB Voltage 24 Vdc CRP0418NCAEM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCAEA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCAEJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCAEI003 + V86050002

2 DC ** +* Piloted solenoid valves normally open, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NAAEL003 + V86050002
AB Voltage 24 Vdc CRP0418NAAEM003 + V86050002
Voltage 24 Vac 50/60 Hz
AC CRP0418NAAE2003 + V86200002
(RAC with rectifier)
Voltage 115 Vac 50 - 120 Vac 60 Hz
AD CRP0418NAAEZ003 + V86200002
(RAC with rectifier)
Voltage 230 Vac 50 - 240 Vac 60 Hz
AE CRP0418NAAEX003 + V86200002
(RAC with rectifier)
AF Voltage 48 Vdc CRP0418NAAEN003 + V86050002

2 DD ** +* Direct operated solenoid valve normally closed, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing

AA Voltage 12 Vdc CRD0418NCAEL002 + V86050002

AB Voltage 24 Vdc CRD0418NCAEM002 + V86050002

2 C * +* Lever operated valve

* Description Code Symbol Drawing

A Without microswitch CMF04L001

B With microswitch CMF04M001

1 = Valves supplied with connector. Without connector see accessories page 89

16 IE/FPA-2/04-2019
Sect. II - FPA Cavity 2
2 H * +* Button operated valves

** Description Code Symbol Drawing

A Push-button control CPE04P000.1

2 .. ** +* Flow control valves (1)

* Flow Code Symbol Drawing


+B 1.4 l/min VSC040101 II
+C 2.3 l/min VSC040201 FPA
+E 2.8 l/min VSC040301
+G 4.3 l/min VSC040401
+J 5.2 l/min VSC040601
+L 6.5 l/min VSC040801
+N 8.0 l/min VSC041101 (1) The flow control valves can be installed with
solenoid valves, with manual controls and with
+Q 11.1 l/min VSC041601 push-button valves.

2 FA * Bidirectional flow control valves not compensated

* Description Code Symbol Drawing

A Screw adjustment CSB04C0000

B Plastic knob adjustment CSB04V0000

2 Z * Hand pumps

* Description Code Symbol Drawing

A Cilindrata 1 cc CPM0410001

B Cilindrata 2 cc CPM0420001

2 T * Plugs and fittings

* Description Code Symbol Drawing

C Plug 3/4 16 UNF R78150099

D Fitting 3/4 16 UNF - G1/4 20001700

E Long plug 3/4 16 UNF 20003800

F Fitting 3/4 16 UNF - G1/4 20009400

K Fitting 3/4 16 UNF DIN - G1/4 20018000

IE/FPA-2/04-2019 17
Sect. II - FPA Cavity 5
Peripheral
Plug
Features
Flow control valve can be combined with plug TC

FPA** ** (...) 2 .. ** +* 5 T * +*

5TG 5TH

II
FPA
+*

Flow control valves

A B 5

A B 5
2

2
1

7 6
1

7 6

5 T * +* Plugs

** Description Code Symbol Drawing

G Plug M16x1.5 (1) R78150104

H Long plug M16x1.5 R78150101

2 .. ** +* Flow control valves (1)

* Flow Code Symbol Drawing


+B 1.4 l/min VSC040101
+C 2.3 l/min VSC040201
+E 2.8 l/min VSC040301
+G 4.3 l/min VSC040401
+J 5.2 l/min VSC040601
+L 6.5 l/min VSC040801
+N 8.0 l/min VSC041101
(1) Flow control valves can be combined with plug
+Q 11.1 l/min VSC041601 TG.

18 IE/FPA-2/04-2019
Sect. II - FPA Cavity 6-7
Return cavities

FPA** ** (...) 2 .. ** +* 5 T * +* 6 * 7 *

ptional flow control valves

Return cavity, omit if not required flow control valves

A B 5

II
2 FPA

7 6
A B 5

7* 6*

Flow control valves


7 6

6 * Flow control valves for return cavities”6-7”


7
* Nominal flow at 120 bar Code Symbol Drawing
A 0.7 l/min VSC06100002
B 1.1 l/min VSC06120002
C 2.1 l/min VSC06130002
E 3.2 l/min VSC06150002
G 4.7 l/min VSC06190002
K 6.3 l/min VSC06220002
N 7.5 l/min VSC06240002
Q 10.0 l/min VSC06280002
U 13.2 l/min VSC06330002
V 15.7 l/min VSC06350002

IE/FPA-2/04-2019 19
Sect. II - FPA Ports A-B

Possible combinations plugs on ports


End section II

FPA** ** (...) 2 .. ** +* 5 T * +* 6 * 7 * -** -

II
FPA

A B 5

2
A B 5

1
2

7 6

7 6

-** Combinations plugs on ports A-B Symbols description

-** P T Type Description Thread Code Symbol Drawing


-00 n n G 1/4” 20024000
Port closed
-02 … n … Q26622255
with plug G 3/8”
(plug whith OR)
-03 n …
n Port open — — —
-06 … …
Combination -00 to use with the standard blocks (page 85)

20 IE/FPA-2/04-2019
Sect. I - FPC Cavity 1
A B 5 C

Pressure relief valve - Check valve - Plug


Setting type (or plug features)
Special setting pressure relief valve (omit if not required)
2 3

FPC** * * (...)

4 1

8 7 6 9

A B 5 C
A1
B1
C1
D1 I
A2
2 3 B2 FPC
C2
D2
A3
B3
C3
4 1 D3
K1

8 7 6 9

X1

* * (...) Pressure relief valve with check valve

Pressure STD setting (...) Special


* * Setting type Code Symbol Drawing
(bar) (bar) setting (bar)
1 Detachable closing CMPR04S00002
15 ÷ 50
D 2 15 ÷ 50 30 Non removable closing (1) CMPR04P00002
(5 to 5)
3 Plastic knob CMPR04M00002 1
1 Detachable closing CMPR04S01002
35 ÷ 110
E 2 35 ÷ 110 50 Non removable closing (1) CMPR04P01002
(5 to 5)
3 Plastic knob CMPR04M01002
2
1 Detachable closing CMPR04S02002
75 ÷ 220
F 2 75 ÷ 220 150 Non removable closing (1) CMPR04P02002
(5 to 5)
3 Plastic knob CMPR04M02002 3
1 Detachable closing CMPR04S03002
160 ÷ 290
G 2 160 ÷ 290 180 Non removable closing (1) CMPR04P03002
(10 to 10)
3 Plastic knob CMPR04M03002
1 = Supplied assembled. Unassembled, see accessories page 89

* * Check valve and plug

* * Description Code Symbol Drawing

K 1 Check valve - Opening pressure 0.5 bar CRI0400001

X 1 Plug R78150100

IE/FPC-1/04-2019 21
Sect. II - FPC Cavity 2
Cavity
Type
Features
Optional flow control valve (omit if not required)

FPC** ** (...) 2 .. ** +*

A B 5 C

2DA** +*

2DB** +* 2 3

II 2DC** +*
4 1

FPC
2DD** +*
8 7 6 9

2C* +*

2H* +*

2FA*

2Z*

A B 5 C

2TC

2TD
2 3

G 1/4
2TE

4 1

2TF

G 1/4
8 7 6 9
2TK

G 1/4

Flow control valves

22 IE/FPC-2/04-2019
Sect. II - FPC Cavity 2
2 DA ** +* Piloted solenoid valves normally closed, without emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCASL003 + V86050002
AB Voltage 24 Vdc CRP0418NCASM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCASA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCASJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCASI003 + V86050002

2 DB ** +* Piloted solenoid valves normally open, with rotary emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCAEL003 + V8605002
AB Voltage 24 Vdc CRP0418NCAEM003 + V86050002
II
AC Voltage 24 Vac 50 Hz CRP0418NCAEA003 + V86050002 FPC
AD Voltage 115 Vac 50 Hz CRP0418NCAEJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCAEI003 + V86050002

2 DC ** +* Piloted solenoid valves normally open, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NAAEL003 + V86050002
AB Voltage 24 Vdc CRP0418NAAEM003 + V86050002
Voltage 24 Vac 50/60 Hz
AC CRP0418NAAE2003 + V86200002
(RAC with rectifier)
Voltage 115 Vac 50 - 120 Vac 60 Hz
AD CRP0418NAAEZ003 + V86200002
(RAC with rectifier)
Voltage 230 Vac 50 - 240 Vac 60 Hz
AE CRP0418NAAEX003 + V86200002
(RAC with rectifier)
AF Voltage 48 Vdc CRP0418NAAEN003 + V86050002

2 DD ** +* Direct operated solenoid valve normally closed, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing

AA Voltage 12 Vdc CRD0418NCAEL002 + V86050002

AB Voltage 24 Vdc CRD0418NCAEM002 + V86050002

2 C * +* Lever operated valve

* Description Code Symbol Drawing

A Without microswitch CMF04L001

B With microswitch CMF04M001

1 = Valves supplied with connector. Without connector see accessories page 89

IE/FPC-2/04-2019 23
Sect. II - FPC Cavity 2
2 H * +* Button operated valves

** Description Code Symbol Drawing

A Push-button control CPE04P000.1

2 .. ** +* Flow control valves (1)

* Flow Code Symbol Drawing


+B 1.4 l/min VSC040101
+C 2.3 l/min VSC040201
+E 2.8 l/min VSC040301

II +G 4.3 l/min VSC040401


+J 5.2 l/min VSC040601
FPC
+L 6.5 l/min VSC040801
+N 8.0 l/min VSC041101 (1) The flow control valves can be installed with
solenoid valves, with manual controls and with
+Q 11.1 l/min VSC041601 push-button valves.

2 FA * Bidirectional flow control valves not compensated

* Description Code Symbol Drawing

A Screw adjustment CSB04C0000

B Plastic knob adjustment CSB04V0000

2 Z * Hand pumps

* Description Code Symbol Drawing

A Cilindrata 1 cc CPM0410001

B Cilindrata 2 cc CPM0420001

2 T * Plugs and fittings

* Description Code Symbol Drawing

C Plug 3/4 16 UNF R78150099

D Fitting 3/4 16 UNF - G1/4 20001700

E Long plug 3/4 16 UNF 20003800

F Fitting 3/4 16 UNF - G1/4 20009400

K Fitting 3/4 16 UNF DIN - G1/4 20018000

24 IE/FPC-2/04-2019
Sect. II - FPC Cavity 3
Cavity
Type
Features
Flow control valve can be combined with plug TC

FPC** ** (...) 2 .. ** +* 3 .. ** +*

A B 5 C
3DD*

3H*
2 3

3FA*
II
4 1

3FB* FPC
8 7 6 9

3A**

3B*

+* 3TC

3TD
A B 5 C

G 1/4
3TE

2 3
3TF

G 1/4

4 1 3TK

G 1/4

Flow control valves


8 7 6 9

IE/FPC-2/04-2019 25
Sect. II - FPC Cavity 3
3 DD ** Piloted solenoid valves normally closed, with emergency (1)

** Description Code (valve + connector) Symbol Drawing

AA Voltage 12 Vdc CRD0418NCAEL002 + V86050002

AB Voltage 24 Vdc CRD0418NCAEM002 + V86050002

3 H * Button operated valves

* Descrizione Codice (elettrovalvola + connettore) Simbolo Disegno

A Push-button control CPE04P000.1

II
FPC
3 FA * Bidirectional flow control valves not compensated

* Description Code (valve + connector) Symbol Drawing

A Screw adjustment CSB04C0000

B Plastic knob adjustment CSB04V0000

3 FB * Unidirectional flow control valves compensated

* Description Code (valve + connector) Symbol Drawing

A Screw adjustment CSC04C0000

B Plastic knob adjustment CSC04V0000

3 A ** Pressure relief valves

** Description Regolazione (bar) Code Symbol Drawing


AD Min 15 - Max 50 CMP04AS0002
AE Min 35 - Max 110 CMP04AS1002
Short screw adjustment
AF Min 75 - Max 220 CMP04AS2002
AG Min 160 - Max 290 CMP04AS3002
BD Min 15 - Max 50 CMP04AC0002
BE Min 35 - Max 110 CMP04AC1002
Screw adjustment
BF Min 75 - Max 220 CMP04AC2002
BG Min 160 - Max 290 CMP04AC3002
CD Min 15 - Max 50 CMP04AM0002
CE Min 35 - Max 110 CMP04AM1002
Plastic knob adjustment
CF Min 75 - Max 220 CMP04AM2002
CG Min 160 - Max 290 CMP04AM3002
DD Min 15 - Max 50 CMP04AP0002
DE Min 35 - Max 110 CMP04AP1002
Short screw + sealed cap
DF Min 75 - Max 220 CMP04AP2002
DG Min 160 - Max 290 CMP04AP3002

1 = Valves supplied with connector. Without connector see accessories page 89

26 IE/FPC-2/04-2019
Sect. II - FPC Cavity 3
3 B * One-way check valves

* Description Code (valve + connector) Symbol Drawing

A 0.7 bar (Standard) CRU0400002

B 4.5 bar CRU0404002

C 10 bar CRU0410002

3 T * +* Plugs and fittings

* Description Code Symbol Drawing

C Plug 3/4 16 UNF (1) R78150099


II
D Fitting 3/4 16 UNF - G1/4 20001700
FPC

E Long plug 3/4 16 UNF 20003800

F Fitting 3/4 16 UNF - G1/4 20009400

K Fitting 3/4 16 UNF - DIN G1/4 20018000

3 T C +* Flow control valves (1)

* Flow Code Symbol Drawing


+B 1.4 l/min VSC040101
+C 2.3 l/min VSC040201
+E 2.8 l/min VSC040301
+G 4.3 l/min VSC040401
+J 5.2 l/min VSC040601
+L 6.5 l/min VSC040801
+N 8.0 l/min VSC041101
(1) The flow control valves can be installed with the
+Q 11.1 l/min VSC041601 plug TC.

IE/FPC-2/04-2019 27
Sect. II - FPC Cavity 4
Cavity
Type
Features

FPC** ** (...) 2 .. ** +* 3 .. ** +* 4 .. **

A B 5 C
4DA**

4DB**
2 3

II 4DC**

4 1
FPC
4DD**

8 7 6 9

4C*

4H*

4FA*

4Z* A B 5 C

4TE

2 3
4TF

G 1/4
4TK 4 1

G 1/4

8 7 6 9

28 IE/FPC-2/04-2019
Sect. II - FPC Cavity 4
4 DA ** Piloted solenoid valves normally closed, without emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCASL003 + V86050002
AB Voltage 24 Vdc CRP0418NCASM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCASA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCASJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCASI003 + V86050002

4 DB ** Piloted solenoid valves normally open, with rotary emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCAEL003 + V8605002
AB Voltage 24 Vdc CRP0418NCAEM003 + V86050002
II
AC Voltage 24 Vac 50 Hz CRP0418NCAEA003 + V86050002 FPC
AD Voltage 115 Vac 50 Hz CRP0418NCAEJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCAEI003 + V86050002

4 DC ** Piloted solenoid valves normally open, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NAAEL003 + V86050002
AB Voltage 24 Vdc CRP0418NAAEM003 + V86050002
Voltage 24 Vac 50/60 Hz
AC CRP0418NAAE2003 + V86200002
(RAC with rectifier)
Voltage 115 Vac 50 - 120 Vac 60 Hz
AD CRP0418NAAEZ003 + V86200002
(RAC with rectifier)
Voltage 230 Vac 50 - 240 Vac 60 Hz
AE CRP0418NAAEX003 + V86200002
(RAC with rectifier)
AF Voltage 48 Vdc CRP0418NAAEN003 + V86050002

4 DD ** Direct operated solenoid valve normally closed, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing

AA Voltage 12 Vdc CRD0418NCAEL002 + V86050002

AB Voltage 24 Vdc CRD0418NCAEM002 + V86050002

1 = Valves supplied with connector. Without connector see accessories page 89

IE/FPC-2/04-2019 29
Sect. II - FPC Cavity 4
4 C * Lever operated valve

* Description Code Symbol Drawing

A Without microswitch CMF04L001

B With microswitch CMF04M001

4 H * Button operated valves

** Description Code Symbol Drawing

II A Push-button control CPE04P000.1

FPC
4 FA * Bidirectional flow control valves not compensated

* Description Code Symbol Drawing

A Screw adjustment CSB04C0000

B Plastic knob adjustment CSB04V0000

4 Z * Hand pumps

* Description Code Symbol Drawing

A Cilindrata 1 cc CPM0410001

B Cilindrata 2 cc CPM0420001

4 T * Plugs and fittings

* Description Code Symbol Drawing

E Long plug 3/4 16 UNF 20003800

F Fitting 3/4 16 UNF - G1/4 20009400

K Fitting 3/4 16 UNF DIN - G1/4 20018000

30 IE/FPC-2/04-2019
Sect. II - FPC Cavity 5
Peripheral
Plug
Features
Flow control valve can be combined with plug TG

FPC** ** (...) 2 .. ** +* 3 .. ** +* 4 .. ** 5 T * +*

5TG 5TH

+*

Flow control valve


II
A B 5 C FPC

A B 5 C
2 3

4 1 2 3

8 7 6 9
4 1

8 7 6 9

5 T * +* Plugs

* Description Code Symbol Drawing

G Plug M16x1.5 (1) R78150104

H Long plug M16x1.5 R78150101

5 T G +* Flow control valves (1)

* Flow Code Symbol Drawing


+B 1.4 l/min VSC040101
+C 2.3 l/min VSC040201
+E 2.8 l/min VSC040301
+G 4.3 l/min VSC040401
+J 5.2 l/min VSC040601
+L 6.5 l/min VSC040801
+N 8.0 l/min VSC041101
(1) The flow control valves can be installed with the
+Q 11.1 l/min VSC041601 plug TG.

IE/FPC-2/04-2019 31
Sect. II - FPC Cavity 6-7-8-9
Return cavities

FPC** ** (...) 2 .. ** +* 3 .. ** +* 4 .. ** 5 T * +* 6 * 7 * 8 * 9 *

Return cavity, omit if not required flow control valves or caps. Optional flow control valves (or plug on cavity 9)

A B 5 C

2 3

II 4 1

FPC A B 5 C

8 7 6 9

2 3

4 1
8* 7* 6* 9* 9L

8 7 6 9
Optional flow control valves (or plug on cavity 9).

6 * Flow control valves for return cavities 6-7-8-9”


7
* Nominal flow at 120 bar Code Symbol Drawing
8
A 0.7 l/min VSC06100002
9
B 1.1 l/min VSC06120002
C 2.1 l/min VSC06130002
E 3.2 l/min VSC06150002
G 4.7 l/min VSC06190002
K 6.3 l/min VSC06220002
N 7.5 l/min VSC06240002
Q 10.0 l/min VSC06280002
U 13.2 l/min VSC06330002
V 15.7 l/min VSC06350002

9T * Plugs for return cavity “9”


* Description Code Symbol Drawing

M Conical plug G3/8 Q26620350

32 IE/FPC-2/04-2019
Sect. II - FTC Ports A-B-C

Combinations plugs on ports


End section II

FPC** ** (...) 2 .. ** +* 3 .. ** +* 4 .. ** 5 T * +* 6 * 7 * 8 * 9 * -** -

A B 5 C
II
A B 5 C FPC
2 3

2 3
4 1

8 7 6 9
4 1

8 7 6 9

-** Combinations plugs on ports A-B-C

-** A B C
-00 n n …
-01 n n n
-02 … n n
-03 n … n Symbols description

-05 n … … Type Description Thread Code Symbol Drawing


G 1/4” 20024000
-06 … … n Port closed
… Q26630006
with plug G 3/8”
-07 … n … (plug with OR)
-08 … … … n Port open — — —
Combination -00 to use with the standard blocks (page 85)

IE/FPC-2/04-2019 33
Sect. I - FPL Cavity 1
A D B C

Pressure relief valve - Check valve - Plug


Setting type (or plug features)
Special setting pressure relief valve (omit if not required)
2 3

FPL** * * (...)

4 1

8 7

A B D C
A1
B1
C1
D1
A2
2 3 B2
C2
D2
A3
I B3
C3
4 1 D3
FPL K1

8 7

X1

* * (...) Pressure relief valve with check valve

Pressure STD setting (...) Special


* * Setting type Code Symbol Drawing
(bar) (bar) setting (bar)
1 Detachable closing CMPR04S00002
15 ÷ 50
D 2 15 ÷ 50 30 Non removable closing (1) CMPR04P00002
(5 to 5)
3 Plastic knob CMPR04M00002 1
1 Detachable closing CMPR04S01002
35 ÷ 110
E 2 35 ÷ 110 50 Non removable closing (1) CMPR04P01002
(5 to 5)
3 Plastic knob CMPR04M01002
2
1 Detachable closing CMPR04S02002
75 ÷ 220
F 2 75 ÷ 220 150 Non removable closing (1) CMPR04P02002
(5 to 5)
3 Plastic knob CMPR04M02002 3
1 Detachable closing CMPR04S03002
160 ÷ 290
G 2 160 ÷ 290 180 Non removable closing (1) CMPR04P03002
(10 to 10)
3 Plastic knob CMPR04M03002
1 = Supplied assembled. Unassembled, see accessories page 89

* * Check valve and plug

* * Description Code Symbol Drawing

K 1 Check valve - Opening pressure 0.5 bar CRI0400001

X 1 Plug R78150100

34 IE/FPL-1/01-2019
Sect. II - FPL Cavity 2
Cavity
Type
Features

FPL** ** (...) 2 .. **

A B D C

2DA**

2DB** 2 3

2DC**
4 1

2DD**
8 7

II
2C*
FPL
2H*

2FA*

2Z*

A D B C

2TC

2TD
2 3

G 1/4
2TE

4 1

2TF

G 1/4
8 7
2TK

G 1/4

IE/FPL-2/01-2019 35
Sect. II - FPL Cavity 2
2 DA ** Piloted solenoid valves normally closed, without emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCASL003 + V86050002
AB Voltage 24 Vdc CRP0418NCASM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCASA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCASJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCASI003 + V86050002

2 DB ** Piloted solenoid valves normally open, with rotary emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCAEL003 + V8605002
AB Voltage 24 Vdc CRP0418NCAEM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCAEA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCAEJ003 + V86050002

II AE Voltage 230 Vac 50 Hz CRP0418NCAEI003 + V86050002

FPL
2 DC ** Piloted solenoid valves normally open, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NAAEL003 + V86050002
AB Voltage 24 Vdc CRP0418NAAEM003 + V86050002
Voltage 24 Vac 50/60 Hz
AC CRP0418NAAE2003 + V86200002
(RAC with rectifier)
Voltage 115 Vac 50 - 120 Vac 60 Hz
AD CRP0418NAAEZ003 + V86200002
(RAC with rectifier)
Voltage 230 Vac 50 - 240 Vac 60 Hz
AE CRP0418NAAEX003 + V86200002
(RAC with rectifier)
AF Voltage 48 Vdc CRP0418NAAEN003 + V86050002

2 DD ** Direct operated solenoid valve normally closed, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing

AA Voltage 12 Vdc CRD0418NCAEL002 + V86050002

AB Voltage 24 Vdc CRD0418NCAEM002 + V86050002

2 C * Lever operated valve

* Description Code Symbol Drawing

A Without microswitch CMF04L001

B With microswitch CMF04M001

1 = Valves supplied with connector. Without connector see accessories page 89

36 IE/FPL-2/01-2019
Sect. II - FPL Cavity 2
2 H * Button operated valves

** Description Code Symbol Drawing

A Push-button control CPE04P000.1

2 FA * Bidirectional flow control valves not compensated

* Description Code Symbol Drawing

A Screw adjustment CSB04C0000

B Plastic knob adjustment CSB04V0000

2 Z * Hand pumps
II
* Description Code Symbol Drawing
FPL
A Cilindrata 1 cc CPM0410001

B Cilindrata 2 cc CPM0420001

2 T * Plugs and fittings

* Description Code Symbol Drawing

C Plug 3/4 16 UNF R78150099

D Fitting 3/4 16 UNF - G1/4 20001700

E Long plug 3/4 16 UNF 20003800

F Fitting 3/4 16 UNF - G1/4 20009400

K Fitting 3/4 16 UNF DIN - G1/4 20018000

IE/FPL-2/01-2019 37
Sect. II - FPL Cavity 3
Cavity
Type
Features

FPL** ** (...) 2 .. ** 3 .. **

A B D C
3DA*

3DB*
2 3

3DC*

4 1

3DD*

8 7

II 3H*

FPL
3FA*

3FB*

A D B C 3A**

3B*

2 3
3TD

G 1/4
4 1
3TE

3TF
8 7
G 1/4
3TK

G 1/4

38 IE/FPL-2/01-2019
Sect. II - FPL Cavity 3
3 DA ** Piloted solenoid valves normally closed, without emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCASL003 + V86050002
AB Voltage 24 Vdc CRP0418NCASM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCASA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCASJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCASI003 + V86050002

3 DB ** Piloted solenoid valves normally open, with rotary emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCAEL003 + V8605002
AB Voltage 24 Vdc CRP0418NCAEM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCAEA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCAEJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCAEI003 + V86050002
II
3 DC ** Piloted solenoid valves normally open, with button emergency (1)
FPL
** Description Code (valve + connector) Symbol Drawing
AA Voltage 12 Vdc CRP0418NAAEL003 + V86050002
AB Voltage 24 Vdc CRP0418NAAEM003 + V86050002
Voltage 24 Vac 50/60 Hz
AC CRP0418NAAE2003 + V86200002
(RAC with rectifier)
Voltage 115 Vac 50 - 120 Vac 60 Hz
AD CRP0418NAAEZ003 + V86200002
(RAC with rectifier)
Voltage 230 Vac 50 - 240 Vac 60 Hz
AE CRP0418NAAEX003 + V86200002
(RAC with rectifier)
AF Voltage 48 Vdc CRP0418NAAEN003 + V86050002

3 DD ** Direct operated solenoid valve normally closed, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing

AA Voltage 12 Vdc CRD0418NCAEL002 + V86050002

AB Voltage 24 Vdc CRD0418NCAEM002 + V86050002

3 H * Button operated valves

* Descrizione Codice (elettrovalvola + connettore) Simbolo Disegno

A Push-button control CPE04P000.1

3 FA * Bidirectional flow control valves not compensated

* Description Code (valve + connector) Symbol Drawing

A Screw adjustment CSB04C0000

B Plastic knob adjustment CSB04V0000

1 = Valves supplied with connector. Without connector see accessories page 89

IE/FPL-2/01-2019 39
Sect. II - FPL Cavity 3
3 FB * Unidirectional flow control valves compensated

* Description Code (valve + connector) Symbol Drawing

A Screw adjustment CSC04C0000

B Plastic knob adjustment CSC04V0000

3 A ** Pressure relief valves

** Description Regolazione (bar) Code Symbol Drawing


AD Min 15 - Max 50 CMPAS0002
AE Min 35 - Max 110 CMPAS1002
Short screw adjustment
AF Min 75 - Max 220 CMPAS2002
AG Min 160 - Max 290 CMPAS3002
BD Min 15 - Max 50 CMPAC0002
BE Min 35 - Max 110 CMPAC1002
Screw adjustment
BF Min 75 - Max 220 CMPAC2002
BG Min 160 - Max 290 CMPAC3002
II CD Min 15 - Max 50 CMPAM0002
FPL CE Min 35 - Max 110 CMPAM1002
Plastic knob adjustment
CF Min 75 - Max 220 CMPAM2002
CG Min 160 - Max 290 CMPAM3002
DD Min 15 - Max 50 CMPAP0002
DE Min 35 - Max 110 CMPAP1002
Short screw + sealed cap
DF Min 75 - Max 220 CMPAP2002
DG Min 160 - Max 290 CMPAP3002

3 B * One-way check valves

* Description Code (valve + connector) Symbol Drawing

A 0.7 bar (Standard) CRU0400002

B 4.5 bar CRU0404002

C 10 bar CRU0410002

3 T * Plugs and fittings

* Description Code Symbol Drawing

D Fitting 3/4 16 UNF - G1/4 20001700

E Long plug 3/4 16 UNF 20003800

F Fitting 3/4 16 UNF - G1/4 20009400

K Fitting 3/4 16 UNF - DIN G1/4 20018000

40 IE/FPL-2/01-2019
Sect. II - FPL Cavity 4
Cavity
Type
Features

FPL** ** (...) 2 .. ** 3 .. ** 4 .. **

A B D C
4DA**

4DB**
2 3

4DC**

4 1

4DD**

8 7

4C*
II
FPL
4H*

4B*

4FA*

4Z* A D B C

4TE

2 3

4TF

G 1/4
4TK 4 1

G 1/4

8 7

IE/FPL-2/01-2019 41
Sect. II - FPL Cavity 4
4 DA ** Piloted solenoid valves normally closed, without emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCASL003 + V86050002
AB Voltage 24 Vdc CRP0418NCASM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCASA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCASJ003 + V86050002
AE Voltage 230 Vac 50 Hz CRP0418NCASI003 + V86050002

4 DB ** Piloted solenoid valves normally open, with rotary emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NCAEL003 + V8605002
AB Voltage 24 Vdc CRP0418NCAEM003 + V86050002
AC Voltage 24 Vac 50 Hz CRP0418NCAEA003 + V86050002
AD Voltage 115 Vac 50 Hz CRP0418NCAEJ003 + V86050002

II AE Voltage 230 Vac 50 Hz CRP0418NCAEI003 + V86050002

FPL
4 DC ** Piloted solenoid valves normally open, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing


AA Voltage 12 Vdc CRP0418NAAEL003 + V86050002
AB Voltage 24 Vdc CRP0418NAAEM003 + V86050002
Voltage 24 Vac 50/60 Hz
AC CRP0418NAAE2003 + V86200002
(RAC with rectifier)
Voltage 115 Vac 50 - 120 Vac 60 Hz
AD CRP0418NAAEZ003 + V86200002
(RAC with rectifier)
Voltage 230 Vac 50 - 240 Vac 60 Hz
AE CRP0418NAAEX003 + V86200002
(RAC with rectifier)
AF Voltage 48 Vdc CRP0418NAAEN003 + V86050002

4 DD ** Direct operated solenoid valve normally closed, with button emergency (1)

** Description Code (valve + connector) Symbol Drawing

AA Voltage 12 Vdc CRD0418NCAEL002 + V86050002

AB Voltage 24 Vdc CRD0418NCAEM002 + V86050002

4 C * Lever operated valve

* Description Code Symbol Drawing

A Without microswitch CMF04L001

B With microswitch CMF04M001

1 = Valves supplied with connector. Without connector see accessories page 89

42 IE/FPL-2/01-2019
Sect. II - FPL Cavity 4
4 B * One-way check valves

* Description Code (valve + connector) Symbol Drawing

A 0.7 bar (Standard) CRU0400002

B 4.5 bar CRU0404002

C 10 bar CRU0410002

4 H * Button operated valves

** Description Code Symbol Drawing

A Push-button control CPE04P000.1

4 FA * Bidirectional flow control valves not compensated

* Description Code Symbol Drawing II


A Screw adjustment CSB04C0000 FPL

B Plastic knob adjustment CSB04V0000

4 Z * Hand pumps

* Description Code Symbol Drawing

A Cilindrata 1 cc CPM0410001

B Cilindrata 2 cc CPM0420001

4 T * Plugs and fittings

* Description Code Symbol Drawing

E Long plug 3/4 16 UNF 20003800

F Fitting 3/4 16 UNF - G1/4 20009400

K Fitting 3/4 16 UNF DIN - G1/4 20018000

IE/FPL-2/01-2019 43
Sect. II - FPL Cavity 7-8

Return cavities

FPL** ** (...) 2 .. ** 3 .. ** 4 .. ** 7 * 8 *

Optional flow control valves


Return cavity, omit if not required flow control valves.

A B D C

2 3

4 1

A D B C

8 7

II
2 3
FPL

4 1
8* 7*

8 7
Optional flow control valves.

7 * Flow control valves for return cavities “7-8”


8
* Nominal flow at 120 bar Code Symbol Drawing
A 0.7 l/min VSC06100002
B 1.1 l/min VSC06120002
C 2.1 l/min VSC06130002
E 3.2 l/min VSC06150002
G 4.7 l/min VSC06190002
K 6.3 l/min VSC06220002
N 7.5 l/min VSC06240002
Q 10.0 l/min VSC06280002
U 13.2 l/min VSC06330002
V 15.7 l/min VSC06350002

44 IE/FPL-2/01-2019
Sect. II - FTL Ports A-B-C-D

Combinations plugs on ports


End section II

FPL** ** (...) 2 .. ** 3 .. ** 4 .. ** 7 * 8 * -** -

A B 5 C

A B 5 C
2 3

II
2 3 FPL
4 1

8 7 6 9
4 1

8 7 6 9

-** Combinations plugs on ports A-B-C-D

-** A B C D Symbols description


-00 n … n … Type Description Thread Code Symbol Drawing
-01 n n n n Port closed
… G 1/4” 20024000
-03 n … n n with plug

-04 n n n … n Port open — — —

IE/FPL-2/01-2019 45
Sect. I - FPE Cavity 1
A D B C

Pressure relief valve - Check valve - Plug


Setting type (or plug features)
Special setting pressure relief valve (omit if not required)
2 3

FPE** * * (...)

A B D C
A1
B1
C1

A2
3 B2
C2
2

A3
B3
C3
1

K1

9
I X1

FPE

* * (...) Pressure relief valve with check valve

Pressure STD setting (...) Special


* * Setting type Code Symbol Drawing
(bar) (bar) setting (bar)
1 Detachable closing CMPR04S00002
15 ÷ 50
D 2 15 ÷ 50 30 Non removable closing (1) CMPR04P00002
(5 to 5)
3 Plastic knob CMPR04M00002
1
1 Detachable closing CMPR04S01002
35 ÷ 110
E 2 35 ÷ 110 50 Non removable closing (1) CMPR04P01002
(5 to 5)
3 Plastic knob CMPR04M01002
2
1 Detachable closing CMPR04S02002
75 ÷ 220
F 2 75 ÷ 220 150 Non removable closing (1) CMPR04P02002
(5 to 5)
3 Plastic knob CMPR04M02002 3
1 Detachable closing CMPR04S03002
160 ÷ 290
G 2 160 ÷ 290 180 Non removable closing (1) CMPR04P03002
(10 to 10)
3 Plastic knob CMPR04M03002
1 = Supplied assembled. Unassembled, see accessories page 89

* * Check valve and plug

* * Description Code Symbol Drawing

K 1 Check valve - Opening pressure 0.5 bar CRI0400001

X 1 Plug R78150100

46 IE/FPL-1/03-2019
Sect. II - FPE Cavity 2
Cavity
Type
Features

FPE** ** (...) 2 D(**) **

A B D C
22D(1A)** 2 4
S2 S1

3 1

22D(1B)** 2 4
S2
3
S1
2
3 1
4 3 2

22D(1C)**
1
S1 S2 2 4
S2 S1
1
3 1

22D(1D)** 2 4
S2 S1
9
3 1

2D(2A)** 2 4

3 1

2D(2B)** 2 4
II
3 1
FPE
2D(2C)** 2 4

4 3 2
1

3 1

2D(2D)** 2 4

3 1

2D(2E)** 2 4
A D B C

3 1

2D(3A)** 2 4

2 3
3 1

2D(3B)** 2 4

3 1 1
2D(3C)** 2 4

4 3 2
1

3 1

2D(3D)** 2 4 9

3 1

2D(3E)** 2 4

3 1

IE/FPL-2/04-2019 47
Sect. II - FPE Cavity 2
2 D(**) ** Solenoid valves 4 way 3 positions with emergency (1)

(**) ** Description Code (valve + connectors) Symbol Drawing


2 4
(1A)AA Voltage 12 Vdc (closed centre “C” spool) C4V0422C3FEL001 + V86050002 (x2)
S2 S1

(1A)AB Voltage 24 Vdc (closed centre “C” spool) C4V0422C3FEM001 + V86050002 (x2) 3 1

2 4
(1B)AA Voltage 12 Vdc (open centre “A” spool) C4V0422A3FEL001 + V86050002 (x2) S2 S1

(1B)AB Voltage 24 Vdc (open centre “A” spool) C4V0422A3FEM001 + V86050002 (x2) 3 1
4 3 2
1
S1 S2
2 4
(1C)AA Voltage 12 Vdc (centre “H” spool) C4V0422H3FEL001 + V86050002 (x2)
S2 S1

(1C)AB Voltage 24 Vdc (centre “H” spool) C4V0422H3FEM001 + V86050002 (x2) 3 1

2 4
(1D)AA Voltage 12 Vdc (centre “Y” spool) C4V0422Y3FEL001 + V86050002 (x2) S2 S1

(1D)AB Voltage 24 Vdc (centre “Y” spool) C4V0422Y3FEM001 + V86050002 (x2) 3 1

2 D(**) ** Solenoid valves 4 way 2 positions without emergency (1)

(**) ** Description Code (valve + connector) Symbol Drawing


(2A)AA Voltage 12 Vdc (closed centre “C” spool) C4V0422C2FSL001 + V86050002 2 4

(2A)AB Voltage 24 Vdc (closed centre “C” spool) C4V0422C2FSM001 + V86050002 3 1

2 4
(2B)AA Voltage 12 Vdc (open centre “A” spool) C4V0422A2FSL001 + V86050002
(2B)AB Voltage 24 Vdc (open centre “A” spool) C4V0422A2FSM001 + V86050002 3 1

II (2C)AA Voltage 12 Vdc (centre “H” spool) C4V0422H2FSL001 + V86050002 2 4

4 3 2
1

(2C)AB Voltage 24 Vdc (centre “H” spool) C4V0422H2FSM001 + V86050002 3 1


FPE 2 4
(2D)AA Voltage 12 Vdc (centre “Y” spool) C4V0422Y2FSL001 + V86050002
(2D)AB Voltage 24 Vdc (centre “Y” spool) C4V0422Y2FSM001 + V86050002 3 1

2 4
(2E)AA Voltage 12 Vdc (direct “D” spool) C4V0422D2FSL001 + V86050002
(2E)AB Voltage 24 Vdc (direct “D” spool) C4V0422D2FSM001 + V86050002 3 1

2 D(**) ** Solenoid valves 4 way 2 positions with emergency (1)

(**) ** Description Code (valve + connector) Symbol Drawing


2 4
(3A)AA Voltage 12 Vdc (closed centre “C” spool) C4V0422C2FEL001 + V86050002
(3A)AB Voltage 24 Vdc (closed centre “C” spool) C4V0422C2FEM001 + V86050002 3 1

2 4
(3B)AA Voltage 12 Vdc (open centre “A” spool) C4V0422A2FEL001 + V86050002
(3B)AB Voltage 24 Vdc (open centre “A” spool) C4V0422A2FEM001 + V86050002 3 1

2 4
(3C)AA Voltage 12 Vdc (centre “H” spool) C4V0422H2FEL001 + V86050002
4 3 2

(3C)AB Voltage 24 Vdc (centre “H” spool) C4V0422H2FEM001 + V86050002 3 1


1

(3D)AA Voltage 12 Vdc (centre “Y” spool) C4V0422Y2FEL001 + V86050002 2 4

(3D)AB Voltage 24 Vdc (centre “Y” spool) C4V0422Y2FEM001 + V86050002 3 1

2 4
(3E)AA Voltage 12 Vdc (direct “D” spool) C4V0422D2FEL001 + V86050002
(3E)AB Voltage 24 Vdc (direct “D” spool) C4V0422D2FEM001 + V86050002 3 1

1 = Valves supplied with connector. Without connector see accessories page 89

48 IE/FPL-2/04-2019
Sect. II - FPE Cavity 3
Cavity
Type
Features
Flow control valve can be combined with plug TC

FPE** ** (...) 2 D(**) ** 3 .. ** +*

A B D C
3FA*

3FB*
3
2

+* 3TC

Optional flow control valve.


9

II
FPE

A D B C

2 3

IE/FPL-2/04-2019 49
Sect. II - FPE Cavity 3
3 FA * Bidirectional flow control valves not compensated

* Description Code (valve + connector) Symbol Drawing

A Screw adjustment CSB04C0000

B Plastic knob adjustment CSB04V0000

3 FB * Unidirectional flow control valves compensated

* Description Code (valve + connector) Symbol Drawing

A Screw adjustment CSC04C0000

B Plastic knob adjustment CSC04V0000

3 T * +* Plug

** Description Code Symbol Drawing

C Plug 3/4 16 UNF (1) R78150099


II
FPE
3 T C +* Flow control valves (1)

* Flow Code Symbol Drawing


+B 1.4 l/min VSC040101
+C 2.3 l/min VSC040201
+E 2.8 l/min VSC040301
+G 4.3 l/min VSC040401
+J 5.2 l/min VSC040601
+L 6.5 l/min VSC040801
+N 8.0 l/min VSC041101
(1) The flow control valves can be installed with the
+Q 11.1 l/min VSC041601 plug TC.

50 IE/FPL-2/04-2019
Sect. II - FPE Cavity 9

Return cavities

FPE** ** (...) 2 D(**) ** 3 .. ** +* 9 *

Optional flow control valve


Return cavity, omit if not required flow control valves.

A B D C

3
2

A D B C

2 3

1 II
Optional flow control valve. 9*
FPE

9 * Flow control valves


* Nominal flow at 120 bar Code Symbol Drawing
A 0.7 l/min VSC06100002
B 1.1 l/min VSC06120002
C 2.1 l/min VSC06130002
E 3.2 l/min VSC06150002
G 4.7 l/min VSC06190002
K 6.3 l/min VSC06220002
N 7.5 l/min VSC06240002
Q 10.0 l/min VSC06280002
U 13.2 l/min VSC06330002
V 15.7 l/min VSC06350002

IE/FPL-2/04-2019 51
Sect. II - FTE Ports A-B-C-D

Combinations plugs on ports


End section II

FPE** ** (...) 2 D(**) ** 3 .. ** +* 9 * -** -

D C
A B D C
A B

3
2 3
2

1 1

II 9

FPE 9

-** Combinations plugs on ports A-B-C-D

-** A B C D Symbols description


-00 n n … n Type Description Thread Code Symbol Drawing
-01 n n n … Port closed
… G 1/4” 20024000
-03 n … n … with plug

-04 n n … … n Port open — — —


With the FPE hydraulic power pack, cannot be mounted the standard blocks.

52 IE/FPL-2/04-2019
Sect. III - Pumps
Pump
Pump group
Performance level
Nominal displacement
Accessories (omit if not required)
End section III

FP ........ P * (*) ** / * -

14
5
P 0 (1) ** Pumps group 05 - Performance level 1

G1/4
Ø 32
Ø 22
L1

Tolerance on Tanks not compatible (•)


Nominal P2 P3 Code L1 Motors
** geometric S01A S09E S02G All
displacement bar bar complete kit mm not compatible
displacement (H) (V) (H) (V) (H) (V) (H) (V)
02 0.25 cc 0.25 ÷ 0.33 230 270 17050037.035 54 M4FB(1) - M4GJ(1)
04 0.45 cc 0.45 ÷ 0.55 230 270 17050036.035 55.7 MM*PA(1)
M*AA(1)D - M*AA(1)G
05 0.56 cc 0.56 ÷ 0.68 230 270 17050039.035 56.7 • •
M*AA(1)H
07 0.75 cc 0.69÷ 0.82 230 270 17050038.035 58.5 • • M*AB(1)D - M*AB(1)G
09 0.92 cc 0.83 ÷ 0.95 230 270 17050053.035 59.8 • • M*AB(1)H
P2 = Intermittent operating pressure Tanks not compatible (as dimensions, see page 55)
P3 = Intermittent peak pressure (20 sec. max) Motors not compatible (interface and transmission not supplied, see
pages 71 - 77)

P 1 (1) ** /* Pumps group 1 - Performance level 1 5 III

G3/8
Ø 32

L1

Tolerance on Tanks not compatible (•)


Nominal P2 P3 Code L1
** geometric S01A S09E S02G All
displacement bar bar complete kit mm
displacement (H) (V) (H) (V) (H) (V) (H) (V)
07 0.80 cc 0.69 ÷ 0.82 170 210 17050107.018 72.4 •
10 1.00 cc 0.96 ÷ 1.09 170 210 17050088.018 73.5 •
12 1.20 cc 1.10 ÷ 1.30 250 290 17050005.018 74.8 •
17 1.70 cc 1.50 ÷ 1.70 250 290 17050006.018 76.2 •
22 2.20 cc 2.10 ÷ 2.30 250 290 17050007.018 78.2 •
26 2.60 cc 2.50 ÷ 2.70 250 290 17050008.018 79.7 • •
32 3.20 cc 3.10 ÷ 3.32 250 290 17050009.018 82.0 • •
38 3.80 cc 3.60 ÷ 3.99 250 290 17050010.018 84.0 • •
43 4.30 cc 4.00 ÷ 4.35 250 290 17050011.018 86.6 • •
48 4.80 cc 4.85 ÷ 4.95 225 260 17050033.018 88.1 • •
60 6.00 cc 5.62 ÷ 6.02 185 215 17050012.018 92.2 • • • • •
78 7.80 cc 7.48 ÷ 7.90 140 160 17050013.018 98.9 • • • • • •
98 9.80 cc 9.60 ÷ 10.00 110 125 17050054.018 107.2 • • • • • •
P2 = Intermittent operating pressure Tanks not compatible (as dimensions,
P3 = Intermittent peak pressure (20 sec. max) see page 55) .

IE/FP-3/01-2017 53
Sect. III - Pumps
P 1 (1) ** /* Accessories for pumps group 1

* Description Type Code Symbol


60.5
0.8 ÷ 2.5
/A VAM0400L
l/min
Single-phase motor start > 2.5 ÷ 8.0 P T T
/B VAM0400M
valve - on auxiliary outlet l/min
> 8.0 ÷ 14
/C VAM0400H
l/min
69
Displacement

Ø 5.5
Soft start valve - on hole
/D VAMS0404001 T
auxiliary outlet Ø 0.4 mm P T

12.5

With Tanks not compatible (•)


**
accessory S01A S09E S02G All
/A /B /C
09
/D • • •
/A /B /C
12
/D • • •
III /A /B /C
17
/D • • •
/A /B /C
22
/D • • •
/A /B /C
26
/D • • •
/A /B /C • •
32
/D • • •
/A /B /C • • •
38
/D • • •
/A /B /C • • •
43
/D • • •
Tanks not compatible (as dimensions, see page 55) .

54 IE/FP-3/01-2017
Sect. IV - Tanks / Sect. V - Tubes kit
Tank (S = with tank and tubes kit; G = only tubes kit, without tank; OMIT if without tank and without tubes kit)
Capacity liters
Features (material and construction)
Mounting position: (H = horizontal; V = vertical)
Variants (00 = standard, no variant) - OMIT if with tubes kit
Orientation - OMIT if with tubes kit in vertical mounting position
End section IV and V

FP ........ * ** * (*) ** /* -

(*) ** *
** Liters * Dimensions (mm) Material Page Page
Mounting Variants Orientation
(H) 00
01 1 A Ø 123 - L 141 Sheet steel 56
(V) 00
(H) 00
1,5 G 130x140 - L 135 Polyethylene 65
(V) 00
02
(H) 00
2 A Ø 123 - L 200 Sheet steel 56
(V) 00
(H) 00
2,5 G 130x140 - L 235 Polyethylene 65
(V) 00
03
(H) 00
3 A Ø 123 - L 330 Sheet steel 56
(V) 00
(H) 00
4 G 130x140 - L 295 Polyethylene 65
(V) 00
04
(H) 00
4 L 180 - L 210 Polyethylene 66
(V) 00
(H) 00-01-02-03-04
5 B Ø 175 - L 246 Sheet steel 57
(V) 00
(H) 00
05 5 C Ø 200 - L 210 Sheet steel 58
(V) 00
(H) 00
5 F 180 - L 240 Polypropylene 64
(V) 00
(H) 00-04
06 6 B Ø 175 - L 308 Sheet steel 57
(V) 00
/1(std)
IV
7 E 154x188 - L 299 Sheet steel (V) 00-01 60
(H) 00
/2
69 V
7 F 180 - L 308 Polypropylene 64 /3
(V) 00
/4
07 (H) 00
7 L 180 - L 310 Polyethylene 67
(V) 00
(H) 00
7 M 180 - L 335 Polietilene 68
(V) 00
(H) 00-04
8 B Ø 175 - L 370 Sheet steel 57
(V) 00
08
(H) 00
8 C Ø 200 - L 306 Sheet steel 58
(V) 00
(H) 00
E 230x130 - L 350 Sheet steel 61
09 9 (V) 00
L 180 - L 370 Polietilene (V) 00 67
(H) 00
10 C Ø 200 - L 373 Sheet steel 58
(V) 00
(H) 00
10 10 D Ø 217 - L 273 Sheet steel 59
(V) 00
(H) 00
10 L 180 - L 410 Polyethylene 67
(V) 00
(H) 00
12 12 D Ø 217 - L 370 Sheet steel 59
(V) 00
14 14 E 255x193 - L 366 Sheet steel (V) 00-01 62
(H) 00-01
25 25 E 250x255 - L 436 Sheet steel 63
(V) 00-01

IE/FP-4-5/06-2017 55
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Tanks Ø 123 - Sheet steel, capacity 1-2-3 liters - Horizontal mounting (black painted)

Capacity (liters) 37
Tank fixing (49149800)
Variant (1) L Tank
Mounting
Capacity
Features

Nominal
kit

Usable
(mm) (with plug)
(screws and O-Ring)

Full

Ø 123
01 141 1 1.0 0.7 90310000

02 A (H) 00 200 2 1.6 1.5 90310001 17010080 L

(..) spare parts


03 330 3 3 2.8 90310002
(1 ) Variant - OMIT if without tank but with tubes kit

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

* ** * (V) ** * - Tanks Ø 123 - Sheet steel, capacity 1-2-3 liters - Vertical mounting (black painted)
(49149800)
Capacity (liters)
101
Tank fixing
L Tank
Variant (1)
Mounting
Capacity
Features

Nominal

IV kit
Usable

(mm) (with plug)


(screws and O-Ring)
Full

V
01 141 1 0.9 0.7 90310009 (60502700)
L

02 A (V) 00 200 2 1.6 1.5 90310010 17010080

03 330 3 2.9 2.9 90310011


Ø 123
(1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

56 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Tanks Ø 175 - Sheet steel, capacity 5-6-8 liters - Horizontal mounting (black painted)

Capacity (liters)
51 (49149800)
Tank fixing
Variant (1) L Tank
Mounting
Capacity
Features

Nominal
kit

Usable
(mm) (with plugs)
(screws and O-Ring)

Full

Ø 175
05 246 5 4.7 4.5 90310003

06 B (H) 00 308 6 6 5.9 90310004 17010080 25


L (R78100021)
08 370 8 8 7.3 90310005
(..) spare parts
(1 ) Variant - OMIT if without tank but with tubes kit

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
05 90310003 05 90310149 05 90310134 05 90310176
06 B (H) 01 06 B (H) 02 06 B (H) 03 90310062 06 B (H) 04
08 08 08 90310069 08

(49149800) (60306400) (49107500) (49121900)

(R78100021) (R78100021) (R78100021) (R78100021)

* ** * (V) ** * - Tanks Ø 175 - Sheet steel, capacity 5-6-8 liters - Vertical mounting (black painted)

Capacity (liters) (49149800)


Tank fixing 127
L Tank
Variant (1)
Mounting
Capacity

IV
Features

Nominal

kit
Usable

(mm) (with plugs)


(screws and O-Ring)
Full

V
05 246 5 4.3 4.1 90310012
L

(60502700)
06 B (V) 00 308 6 5.8 5.5 90310013 17010080

08 370 8 7.5 7.2 90310015


Ø 175
(1 ) Variant - OMIT if without tank but with tubes kit
(R78100021) (..) spare parts

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

IE/FP-4-5/06-2017 57
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Tanks Ø 200 - Sheet steel, capacity 5-8-10 liters - Horizontal mounting (black painted)

Capacity (liters)
Tank fixing (49149800)
Variant (1) L Tank
Mounting
Capacity

L
Features

Nominal
kit

Usable
(mm) (with plugs)
(screws and O-Ring)

Full

Ø 200
05 205 5 5.3 5.0 90310425

08 C (H) 00 301 8 8.0 7.7 90310428 17010080

10 368 10 10 9.3 90310431 (..) spare parts (R78100021)


(1 ) Variant - OMIT if without tank but with tubes kit

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
05 90310453
08 C (H) 03 90310443
10 90310483

(49107500)

(R78100021)

* ** * (V) ** * - Tanks Ø 200 - Sheet steel, capacity5-8-10 liters - Vertical mounting (black painted)

Capacity (liters)
(49149800)
Tank fixing
L Tank
Variant (1)
Mounting
Capacity

IV
Features

Nominal

kit
Usable

(mm) (with plugs)


(screws and O-Ring)
Full

(R78100021)
V
L

05 205 5 4.6 4.3 90310444

08 C (V) 00 301 8 7.5 7.1 90310437 17010080


Ø 200
10 368 10 9.5 9.1 90310439
(..) spare parts
(1 ) Variant - OMIT if without tank but with tubes kit

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

58 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Tanks Ø 217 - Sheet steel, capacity10-12 liters - Horizontal mounting (black painted)
220 (12 liters)
Capacity (liters) Ø 11
(12 liters)
Tank fixing
Variant (1) L Tank
Mounting
Capacity
Features

Nominal
kit

(12 liters)
Usable
(mm) (with plugs)
(screws and O-Ring)

150
Full
10 273 10 8 7.6 90310006
D (H) 00 17010080 72
(49105800)
12 370 12 12 11 90310058
(1 ) Variant - OMIT if without tank but with tubes kit

Ø 217
81
L

Other variants (..) spare parts (20018500)


Variant Tank Variant Tank Variant Tank Variant Tank

* ** * (V) ** * - Tanks Ø 217 - Sheet steel, capacity10-12 liters - Vertical mounting (black painted)
(491105800)
Capacity (liters) 167
Tank fixing
L Tank
Variant (1)
Mounting
Capacity

IV
Features

Nominal

kit
Usable

(mm) (with plugs)


(screws and O-Ring)
Full

V
10 273 10 7 6.8 90310029 (MEG5121200)
L

D (V) 00 17010080
12 370 12 10.3 10.1 90310100
(1 ) Variant - OMIT if without tank but with tubes kit

(20018500) (..) spare parts

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

IE/FP-4-5/06-2017 59
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (V) ** * - Rectangular tanks - Sheet steel, capacity 7 liters - Vertical mounting (black painted)
(49154200)
Capacity (liters)
Tank fixing

112
Variant (1) L Tank
Mounting

97
Capacity
Features

Nominal
kit

Usable
(mm) (with plugs)

200
(screws and O-Ring)

Full

88
22
07 E (V) 00 299 7 5.5 5.1 90310014 17010080 (49154200)
215,5
11 N°4
(1 ) Variant - OMIT if without tank but with tubes kit

37

178
154
45
62,5
7 80 183
L
(..) spare parts
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
07 E (V) 01 90310036

(49107500)

(49154200)

IV
V

60 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Rectangular tanks - Sheet steel, capacity 9 liters - Horizontal mounting (black painted)

Capacity (liters) (49149800)

12
Tank fixing
Variant (1) L Tank (R78100021)
Mounting
Capacity
Features

Nominal
kit

Usable
(mm) (with plugs)
(screws and O-Ring)

Full

230
93
09 E (H) 00 350 9 9 8 90310142 17010080
25 211

22
(1 ) Variant - OMIT if without tank but with tubes kit

130

133
22
L
(..) spare parts
Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

* ** * (V) ** * - Rectangular tanks - Sheet steel, capacity 9 liters - Vertical mounting (black painted)

Capacity (liters) (49149800)

12
Tank fixing
L Tank
Variant (1)
Mounting
Capacity

IV
Features

Nominal

kit

130
133
Usable

(mm) (with plugs)

22
(screws and O-Ring)
Full

V
(R78100021)
211 25
22

09 E (V) 00 350 9 8.6 7.5 90310142 17010080


93

(1 ) Variant - OMIT if without tank but with tubes kit


230

236

(..) spare parts L


Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

IE/FP-4-5/06-2017 61
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (*) ** * - Rectangular tanks - Sheet steel, capacity 14 liters - Vertical mounting (black painted)

Capacity (liters)
(49149800)

12
Tank fixing
Variant (1) L Tank
Mounting
Capacity
Features

Nominal
kit

Usable
(mm) (with plugs)
(screws and O-Ring)

Full

219
193
22
14 E (V) 00 366 14 14 13 90310045 17010080
(49154200)
L
(1 ) Variant - OMIT if without tank but with tubes kit
265
220
37

91
277.5

300
94
20

11
(..) spare parts 75 73

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
14 E (V) 01 90310046

(49107500)

(49154200)

IV
V

62 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (*) ** * - Rectangular tanks - Sheet steel, capacity 25 liters - Horizontal mounting (black painted)
19 46 (49118000)
Capacity (liters)
Tank fixing (20022600)
Variant (1) L Tank

105 183.5
Mounting
Capacity
Features

Nominal
kit

Usable
(mm) (with plugs)
(screws and O-Ring)

255
Full

35
(25)
25 E (H) 00 436 25 22 21 90310060 17010080 16.5 n°4

46

200
250
(1 ) Variant - OMIT if without tank but with tubes kit

60
L (25)

(16)
474 (16)

506

Other variants (..) spare parts

Variant Tank Variant Tank Variant Tank Variant Tank


25 E (H) 01 90310083

(49120600)

(20022600)

* ** * (*) ** * - Rectangular tanks - Sheet steel, capacity 25 liters - Vertical mounting (black painted)
(49118000) 46

33.5
100
26

Capacity (liters)
Tank fixing
L Tank
Variant (1)
Mounting
Capacity

IV
Features

Nominal

kit
Usable

(mm) (with plugs)


281

255
(screws and O-Ring)
Full

35

V
(25)
90310071 16.5 n°4
25 E (V) 00 436 25 25 22 17010080 (20022600)
46

200
250

(1 ) Variant - OMIT if without tank but with tubes kit


125
60

L (25)
(16)

474 (16)

506

Other variants (..) spare parts

Variant Tank Variant Tank Variant Tank Variant Tank


25 E (V) 01 90310124

(49120600)

(20022600)

IE/FP-4-5/06-2017 63
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Square polypropylene tanks capacity 5-7 liters - Horizontal mounting

Capacity (liters)
Tank fixing
Variant (1) L Tank (49138700)
Mounting
Capacity
Features

Nominal
kit

Usable
(mm) (with plug, brackets, nuts)
(screws and O-Ring)

Full

105

180

190
05 242 5 5.4 4.5 90310313

90
F (H) 00 17010083
L

07 308 7 7.4 6.5 90310289

Operating temperature -10°C ÷ +60°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts

* ** * (V) ** * - Square polypropylene tanks capacity 5-7 liters - Vertical mounting


90 105
Capacity (liters)
Tank fixing
L Tank
Variant (1)
Mounting

(49138700)
Capacity
Features

Nominal

kit
Usable

(mm) (with plug, brackets, nuts)


(screws and O-Ring)
Full

L
05 242 5 5.4 4.5 90310313
F (V) 00 17010083
07 306 7 7.4 6.5 90310289
(..) spare parts

Operating temperature -10°C ÷ +60°C - (1 ) Variant - OMIT if without tank but with tubes kit

IV
V

64 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Square polyethylene tanks capacity 1.5-2.5-4 liters - Horizontal mounting

Capacity (liters) (V60513005) (C86100001)


Tank fixing
Variant (1) L Tank
Mounting
35
Capacity
Features

Nominal
kit collar Ø123

Usable
(mm) (with plugs, clamp, nuts)
(screws and O-Ring)

104.5
Full

94
MAX

140
02 135 1.5 1.3 1 90310491

70
MIN

MAX

MIN
03 G (H) 00 235 2.5 2.5 2 90310484 17010081
L 130
04 295 4 3.4 2.5 90310422
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

* ** * (V) ** * - Square polyethylene tanks capacity 1.5-2.5-4 liters - Vertical mounting

Capacity (liters) 02 = 49153500


Tank fixing 03-04 = 49138700
L Tank
Variant (1)
Mounting
Capacity

IV
Features

Nominal

kit collar Ø123


Usable

(mm) (with plugs, clamp, nuts)


(screws and O-Ring)
Full

V
MAX
MIN

MAX

02 135 1.5 1.1 0.7 90310486


L

03 G (V) 00 235 2.5 2.7 2.3 90310419 17010081 MIN

04 296 4 3.5 3.1 90310402


Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (49154200)

(..) spare parts

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

IE/FP-4-5/06-2017 65
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Square polyethylene tanks capacity 4 liters - Horizontal mounting

Capacity (liters) (C86100001)


Tank fixing 35
Variant (1) L Tank
Mounting
Capacity
Features

Nominal
kit collar Ø123 (V60513005)

Usable
(mm) (with plugs, clamp, nuts)
(screws and O-Ring)

Full

119
104.5
MAX

95
MAX

180
90.5

85
MIN

MAX
MIN

04 L (H) 00 210 4 3.6 3 90310331 17010081

MIN
L 180
(49154200)
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

* ** * (V) ** * - Square polyethylene tanks capacity 4 liters - Vertical mounting

Capacity (liters)
(49153500)
Tank fixing
L Tank
Variant (1)
Mounting
Capacity

IV
Features

Nominal

kit collar Ø123


Usable

(mm) (with plugs, clamp, nuts)


(screws and O-Ring)
Full

MAX

V
MIN

MAX
L

MIN

MAX

MIN

04 L (V) 00 210 4 3.7 3 90310332 17010081


(49154200)

Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank
04 L (V) 01 90310433

(49138700)

MAX
MIN

MAX
MIN

MAX

MIN

66 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (*) ** * - Square polyethylene tanks capacity 7-10 liters - Horizontal mounting

Capacity (liters) (C86100001)


Tank fixing
Variant (1) L Tank (V60513005)
Mounting
Capacity
Features

Nominal
kit collar Ø123 35

Usable
(mm) (with plugs, clamp, nuts)
(screws and O-Ring)

Full

102.5

119
MAX

95
MAX

180
67
07 310 7 6.7 5.5 90310330

85
MIN

MAX
MIN

MIN
L (H) 00 17010081 L 20 180
10 410 10 8.7 7.5 90310339
(V60513005)
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts

* ** * (*) ** * - Square polyethylene tanks capacity 7-10 liters - Vertical mounting


07= 49138700
Capacity (liters) 10= 49153500
Tank fixing
L Tank
Variant (1)
Mounting
Capacity
Features

Nominal

kit collar Ø123 MAX

MIN

MAX
Usable

(mm) (with plugs, clamp, nuts)


(screws and O-Ring)
Full

MIN

MAX
07 310 7 6.7 6 90310403
MIN

L (V) 00 17010081
10 410 10 9.8 9 90310338
(V60513005) (49154200)
Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit
(..) spare parts

IV
V

(49153500)
* ** * (*) ** * - Square polyethylene tanks capacity 9 liters - Vertical mounting 102

Capacity (liters)
Tank fixing
L Tank
Variant (1)
Mounting
Capacity
Features

Nominal

kit collar Ø123


Usable

(mm) (with plugs, clamp, nuts)


L

(screws and O-Ring)


Full

09 L (V) 00 370 9 8.6 8 90310371 17010081


21

Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (V60513005)
180

85 95
180

(..) spare parts

IE/FP-4-5/06-2017 67
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (H) ** * - Special square polyethylene tanks capacity 7 liters - Horizontal mounting

Capacity (liters)
Tank fixing
Variant (1) L Tank
Mounting
(49155600)
Capacity
Features

Nominal
kit collar Ø123

Usable
(mm) (with plugs, clamp, nuts)
(screws and O-Ring)

Full

MAX

MIN

113
122
MAX

180
07 M (H) 00 335 7 7.3 6.6 90310380 17010081

67
MIN

L 180

Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

* ** * (V) ** * - Special square polyethylene tanks capacity 7 liters - Vertical mounting

Capacity (liters) (49155600)


Tank fixing
L Tank
Variant (1)
Mounting
Capacity

IV
Features

Nominal

kit collar Ø123


Usable

(mm) (with plugs, clamp, nuts)


(screws and O-Ring)
Full

V
MAX
MIN

MAX
L

07 M (V) 00 335 7 7.2 6.4 90310380 17010081


MIN

Operating temperature -10°C ÷ +70°C - (1 ) Variant - OMIT if without tank but with tubes kit (..) spare parts

Other variants
Variant Tank Variant Tank Variant Tank Variant Tank

68 IE/FP-4-5/06-2017
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (*) ** /* - Tanks orientation according to the mounting position

/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Horizontal

A A
B
S ** (H)
C A
D
A

(1)

/* Orientation
For tanks (*) Mounting position
/1 (standard)
Horizontal

S 09 E (H)

/* Orientation
For tanks (*) Mounting position
/1 (standard)
Horizontal

IV
A
V
S 25 E (H)

/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Horizontal

F A
S ** G (H)
L A

(1)

(1) Orientation TO BE USED with blocks

IE/FP-4-5/06-2017 69
Sect. IV - Tanks / Sect. V - Tubes kit
* ** * (*) ** /* - Tanks orientation according to the mounting position

/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Vertical

A
B
C
S ** D (V)
F A A A A
G
L
(2)

/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Vertical

S 07 E (V)
A A A A

(1)

/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Vertical

IV
V
09
S E (V)
25 A A A A

(1)

/* Orientation
For tanks (*) Mounting position
/1 (standard) /2 /3 /4
Vertical

S 14 E (V)
A A A A

(1)

(1) Orientation TO BE USED with blocks


(2) D Orientation DO NOT USE with blocks

70 IE/FP-4-5/06-2017
Sect. VI - DC Motors
Motor
Voltage
Power / Size
Version
Accessories
Orientation
End section VI
All motors are equipped with a transmission kit
(coupling and components for the assembly)
FP ........ M * ** (*) * /* -

* Voltage ** Power Size (*) Version Page * Accessories /* Orientation Page


GA 350 W Ø 80 (1) Std 72 0-B
GC 700 W Ø 80 (1) Std 72 0-B
2 12 VDC AA 1500 W Ø 115 (1) Std 73 0-B-C-D-F-G-H
EN 1600 W Ø 115 (1) Std 73 0-B-C-E
GN 1600 W Ø 115 (1) Std 74 0-B-C-E /1
GB 400 W Ø 80 (1) Std 72 0-B /2 Std
76
GD 800 W Ø 80 (1) Std 72 0-B /3
AB 2000 W Ø 115 (1) Std 73 0-B-C-D-F-G-H /4
4 24 VDC ES 2200 W Ø 115 (1) Std 73 0-B-C-E
GP 2200 W Ø 115 (1) Std 74 0-B-C-E
GJ 3000 W Ø 125 (1) Std 74 0-B-C-E
FB 3000 W Ø 125 (1) Std 74 0-B-C-E

* Accessories description Page


0 Without accessories —
B Starting switch 75
C Thermal protection —
D (•) Ventilation 75 VI
E Starting switch + thermal protection —
F (•) Starting switch + ventilation —
DC
G Thermal protection + ventilation —
H (•) Starting switch + thermal protection + ventilation —
(•)= IP protection level becomes effective after installationon on power pack.
Acquires IP 10 level with “ventilation” accessory.

For more details, features and performances DC motors, see catalog Dana code DOC00053.

IE/FP-6DC/04-2017 71
Sect. VI - DC Motors
Motors: 12 VDC 350 W / 24 VDC 400 W (permanent magnets)
Voltage W A rpm Nm S2 min S3% IP IC Ø mm Code (…)
M 2 GA (1) * /* 12 VDC 350 40 3300 1.0 10 35 54 F 80 25021400
M 4 GB (1) * /* 24 VDC 400 30 3100 1.2 5 20 54 F 80 25021500
IP protection level becomes effective after installationon on power pack.
(…) Motor without accessories

7 n.2

M * ** (*) * /* - Accessories (page 75)

* Description
Ø 80
101

Ø 80
0 Without accessories

6.40
M6 n.2

B Starting switch 120A fixing with clamp


143.5 13.80 MAX

Code trasmission kit: page 83

Motors: 12 VDC 700 W / 24 VDC 800 W (permanent magnets)


Voltage W A rpm Nm S2 min S3% IP IC Ø mm Code (…)
M 2 GC (1) * /* 12 VDC 700 90 3300 2.0 2.5 10 54 F 80 25021600
M 4 GD (1) * /* 24 VDC 800 70 3000 2.5 2 5 54 F 80 25021700
IP protection level becomes effective after installationon on power pack.
(…) Motor without accessories

7 n.2
M * ** (*) * /* - Accessories (page 75)
VI * Description
Ø 80
101

Ø 80

DC 0 Without accessories
6.40

B Starting switch 120A

M6 n.2 162 13.80 MAX


Code trasmission kit: page 83

For more details, features and performances DC motors, see catalog Dana code DOC00053.

72 IE/FP-6DC/04-2017
Sect. VI - DC Motors
Motors: 12 VDC 1500 W / 24 VDC 2000 W (wound field compound)
Voltage W A rpm Nm S2 min S3% IP IC Ø mm Code (…)
M 2 AA (1) * /* 12 VDC 1500 225 2500 5.5 1 5 54 F 115 25022200
M 4 AB (1) * /* 24 VDC 2000 150 2250 8 2 5 54 F 115 25022300
IP protection level becomes effective after installationon on power pack.
(…) Motor without accessories

M * ** (*) * /* - Accessories (page 75)


M8
9.1 MAX * Description

0 Without accessories

Ø98.3
Ø15
6.4
Ø112
Ø35

B Starting switch 120A


11 MAX

D Ventilation
12.3 MAX 173
1/4-20 UNC-2A
91
F Ventilation + Starting switch

G Ventilation + Thermal protection

H Ventilation + Thermal protection + Starting switch


Code trasmission kit: page 83
Acquires IP 10 protection level with “ventilation” accessory.

Motors: 12 VDC 1600 W / 24 VDC 2200 W (wound field compound)


Voltage W A rpm Nm S2 min S3% IP IC Ø mm Code (…)
M 2 EN (1) * /* 12 VDC 1600 230 2600 5 2 10 54 F 115 25021100
M 4 ES (1) * /* 24 VDC 2200 140 2700 8 1.2 5 54 F 115 25021200
IP protection level becomes effective after installationon on power pack.
( ) Motor without accessories

9.1 133
VI
Ø15

M8
6.4

DC
D1E1

M5 n°2 M * ** (*) * /* - Accessories (page 75)


Ø114
Ø35

90.4

* Description
A2E2

1/4-20UNC 0 Without accessories


11 max
12.3 158 Ø98.32 B Starting switch 120A

C Thermal protection

Code trasmission kit: page 83


E Starting switch + thermal protection

For more details, features and performances DC motors, see catalog Dana code DOC00053.

IE/FP-6DC/04-2017 73
Sect. VI - DC Motors
Motors: 12 VDC 1600 W / 24 VDC 2200 W (wound field serie)
Voltage W A rpm Nm S2 min S3% IP IC Ø mm Code (…)
M 2 GN (1) * /* 12 VDC 1600 220 2600 6 4 8 54 F 115 25022600
M 4 GP (1) * /* 24 VDC 2200 140 2600 6 2 7.5 54 F 115 25022700
IP protection level becomes effective after installationon on power pack.
(…) Motor without accessories

8.4 121.2
M * ** (*) * /* - Accessories (page 75)

M8
* Description
6.43
Ø15

M5 n°2
Ø114.3
Ø35

0 Without accessories
90.4

B Starting switch 120A


1/4-20UNC
9.1
11.8 161.8 Ø98.32 Code trasmission kit: page 83

Motors: 24 VDC 3000 W (wound field compound)


Voltage W A rpm Nm S2 min S3% IP IC Ø mm Code (…)
M 4 FB (1) * /* 24 VDC 3000 200 3300 8.5 4 15 20 F 125 25021300
M 4 GJ (1) * /* 24 VDC 3000 180 3500 8.5 3.5 15 20 F 125 25022400
IP protection level becomes effective after installationon on power pack.
(…) Motor without accessories

M * ** (*) * /* - Accessories (page 75)


VI Adapter: supplied with the transmission kit
** * Description
DC 0 Without accessories
M8

M5 n°2
Ø125

B Starting switch 150A


Ø42

102

FB
GJ
8

D Ventilation
28.5 207.5 (M4FB) M6
43 200 (M4GJ) F Ventilation + Starting switch

G Ventilation + Thermal protection


FB
H Ventilation + Thermal protection + Starting switch

Code trasmission kit: page 83

For more details, features and performances DC motors, see catalog Dana code DOC00053.

74 IE/FP-6DC/04-2017
Sect. VI - DC Motors
M * ** (*) C /* - Accessory: Thermal protection

Thermal protection Ø
Code Ø mm For motors
90340009 16 M2EN - M4ES

M * ** (*) B /* - Accessory: Starting switch

182.5
72
64.5
57.3 Female Faston 5
Female Faston 5 29
6.3-08 N.2

M8 N.2
6.3-08 N.2 20
M6 N.2

Ø 54.5
Ø 40

26
21

120A starting switch 150A starting switch


Code (•) VDC For motors Code (•) VDC For motors
KIT07012.027 12 M2GA - M2GC KIT07012.019 24 M4FB - M4GJ
KIT07012.032 24 M4GB - M4GD
KIT07012.033 12 M2AA (•) Complete kit with all assembly components.
KIT07012.034 24 M4AB
KIT07012.025 12 M2EN - M2GN
KIT07012.026 24 M4ES - M2GP

For more details, features and performances DC motors, see catalog Dana code DOC00053.

M * ** (*) * /* - Accessory: Ventilation (motor included)

9 (N°4) 9 (N°4)

VI
5
118
118

DC
5

118 52.6 46 173 118 53.2 55.9 207.5


IP 10 protection IP 10 protection

* Code (•) VDC For motors * Code (•) VDC For motors
D KIT09008.061 12 M2AA D KIT09008.029 24 M4FB
G KIT09008.062 12 M2AA + thermal protecion (•) Complete kit with all assembly components (motor, transmission kit, etc).
D KIT09008.031 24 M4AB
G KIT09008.063 24 M4AB + thermal protecion

For more details, features and performances DC motors, see catalog Dana code DOC00053.

IE/FP-6DC/04-2017 75
Sect. VI - DC Motors
M * ** (*) * /* - Motor orientation

Starting switch and poles position.

Do not use “orientation 1”


/1 with blocks.

Std
/4 /2

/3

VI
DC

76 IE/FP-6DC/04-2017
Sect. VI - AC Motors
Motor
Phases
Poles
Size
Power range
Version
Orientation
End section VI
FP ........ M * * * * (*) /* -

Power range
* Phases * Poles * Size * Page (*) Version /* Orientation Page
Power Voltage
L 71 A 0.37 kW 230 Vac 50 Hz 78
L 71 B 0.55 kW 230 Vac 50 Hz 78
S 71 A 0.75 kW 230 Vac 50 Hz 80
S 71 B 1.10 kW 230 Vac 50 Hz 80
2 M 80 A 0.75 kW 230 Vac 50 Hz 78
M 80 B 1.10 kW 230 Vac 50 Hz 78
N 90 A 1.50 kW 230 Vac 50 Hz 78
N 90 B 2.20 kW 230 Vac 50 Hz 78
P 100 A 3.00 kW 230 Vac 50 Hz 78
Single
M L 71 A 0.25 kW 230 Vac 50 Hz 78
phase
L 71 B 0.37 kW 230 Vac 50 Hz 78
S 71 C 0.85 kW 230 Vac 50 Hz 80
M 80 A 0.55 kW 230 Vac 50 Hz 78
M 80 B 0.75 kW 230 Vac 50 Hz 78
4
N 90 A 1.10 kW 230 Vac 50 Hz 78
N 90 B 1.50 kW 230 Vac 50 Hz 78
V 90 A 1.80 kW 230 Vac 50 Hz 81
V 90 B 3.00 kW 230 Vac 50 Hz 81
P 100 A 2.20 kW 230 Vac 50 Hz 78
R 63 A 0.18 kW 230/400 Vac 50 Hz 79
R 63 B 0.25 kW 230/400 Vac 50 Hz 79
L 71 A 0.37 kW 230/400 Vac 50 Hz 79
L 71 B 0.55 kW 230/400 Vac 50 Hz 79
/1
S 71 A 0.75 kW 230/400 Vac 50 Hz 80
/2
S 71 B 1.10 kW 230/400 Vac 50 Hz 80 (1) Std Std 82
/3
M 80 A 0.75 kW 230/400 Vac 50 Hz 79
2 /4
M 80 B 1.10 kW 230/400 Vac 50 Hz 79
T 80 A 2.70 kW 230/400 Vac 50 Hz 81
T 80 B 2.70 kW 230/400 Vac 50 Hz 81
79
N
N
90
90
A
B
1.50 kW 230/400 Vac 50 Hz
2.20 kW 230/400 Vac 50 Hz 79
VI
P 100 A 3.00 kW 230/400 Vac 50 Hz 79
AC
P 112 B 4.00 kW 230/400 Vac 50 Hz 79
Three R 63 A 0.12 kW 230/400 Vac 50 Hz 79
T
phase R 63 B 0.18 kW 230/400 Vac 50 Hz 79
L 71 A 0.25 kW 230/400 Vac 50 Hz 79
L 71 B 0.37 kW 230/400 Vac 50 Hz 79
S 71 A 0.75 kW 230/400 Vac 50 Hz 80
M 80 A 0.55 kW 230/400 Vac 50 Hz 79
M 80 B 0.75 kW 230/400 Vac 50 Hz 79
T 80 A 2.20 kW 230/400 Vac 50 Hz 81
4
T 80 B 2.20 kW 230/400 Vac 50 Hz 81
T 80 C 2.20 kW 230/400 Vac 50 Hz 81
T 80 D 3.00 kW 230/400 Vac 50 Hz 81
N 90 A 1.10 kW 230/400 Vac 50 Hz 79
N 90 B 1.50 kW 230/400 Vac 50 Hz 79
P 100 A 2.20 kW 230/400 Vac 50 Hz 79
P 100 B 3.00 kW 230/400 Vac 50 Hz 79
P 112 C 4.00 kW 230/400 Vac 50 Hz 79
Motors supplied with all assembly components (transmission kit, coupling, etc).

IE/FP-6AC/04-2017 77
Sect. VI - AC Motors

L2

Adapter: supplied with the transmission kit

H1

D1
D2
L1

Single-phase motors 2-4 Poles - 230 Vac 50Hz - Version B14

Cable gland
Power range Adapter

metric thred
D1 D2 H1 L1 Screw Single Transmission kit
Phases

Power
UNI L2
Poles

(•) (•) (•) (•) Voltage IP IC S1 Code Motor (for pump)


Size

kW 5931

M M 2 L A (1) 2 2 71 14 148 115 208 0.37 230 Vac 50 Hz 54 F Si 20-25 61000700 M6x20 19.5 M12E2000 KIT08019.011 (Gr.05)
M M 2 L B (1) 2 2 71 14 148 115 208 0.55 230 Vac 50 Hz 54 F Si 20-25 61000700 M6x20 19.5 M12F2000 KIT08019.012 (Gr.1)

M M 2 M A (1) 2 2 80 19 170 126 234 0.75 230 Vac 50 Hz 54 F Si 20-25 61000800 M6x20 30.4 M13G2000 KIT08019.013 (Gr.05)
M M 2 M B (1) 2 2 80 19 170 126 234 1.10 230 Vac 50 Hz 54 F Si 20-25 61000800 M6x20 30.4 M13H2000 KIT08019.014 (Gr.1)

M M 2 N A (1) 2 2 90 24 185 142 247 1.50 230 Vac 50 Hz 54 F Si 20-25 61000900 M8x21 40.4 M14L2000 KIT08019.015 (Gr.05)
M M 2 N B (1) 2 2 90 24 185 142 272 2.20 230 Vac 50 Hz 54 F Si 20-25 61000900 M8x21 40.4 M14N2000 KIT08019.016 (Gr.1)

KIT08019.017 (Gr.05)
M M 2 P A (1) 2 2 100 28 210 155 310 3.00 230 Vac 50 Hz 54 F Si 25-32 61001000 M8x28 75 M15P2000
KIT08019.018 (Gr.1)

M M 4 L A (1) 2 4 71 14 148 115 208 0.25 230 Vac 50 Hz 54 F Si 20-25 61000700 M6x20 19.5 M12D4000 KIT08019.011 (Gr.05)
M M 4 L B (1) 2 4 71 14 148 115 208 0.37 230 Vac 50 Hz 54 F Si 20-25 61000700 M6x20 19.5 M12E4000 KIT08019.012 (Gr.1)

M M 4 M A (1) 2 4 80 19 170 126 234 0.55 230 Vac 50 Hz 54 F Si 20-25 61000800 M6x20 30.4 M13F4000 KIT08019.013 (Gr.05)
M M 4 M B (1) 2 4 80 19 170 126 234 0.75 230 Vac 50 Hz 54 F Si 20-25 61000800 M6x20 30.4 M13G4000 KIT08019.014 (Gr.1)

M M 4 N A (1) 2 4 90 24 185 142 247 1.10 230 Vac 50 Hz 54 F Si 20-25 61000900 M8x21 40.4 M14H4000 KIT08019.015 (Gr.05)
M M 4 N B (1) 2 4 90 24 185 142 272 1.50 230 Vac 50 Hz 54 F Si 20-25 61000900 M8x21 40.4 M14L4000 KIT08019.016 (Gr.1)
VI
KIT08019.017 (Gr.05)
M M 4 P A (1) 2 4 100 28 210 155 310 2.20 230 Vac 50 Hz 54 F Si 25-32 61001000 M8x28 75 M15N4000
KIT08019.018 (Gr.1)
AC
(•)= Approximate dimensions

78 IE/FP-6AC/04-2017
Sect. VI - AC Motors

L2

Adapter: supplied with the transmission kit

H1

D1
D2
L1

Three-phase motors 2-4 Poles - 230/400 Vac 50Hz - Version B14

Cable gland
Power range Adapter

metric thred
D1 D2 H1 L1 Power Screw Single Transmission kit
Phases

UNI L2
Poles

(•) (•) (•) (•) Voltage IP IC S3 Code Motor (for pump)


Size

kW 5931

M T 2 R A (1) 3 2 63 11 125 95 189 0.18 230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31C2000 KIT08019.009 (Gr.05)
M T 2 R B (1) 3 2 63 11 125 95 189 0.25 230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31D2000 KIT08019.010 (Gr.1)

M T 2 L A (1) 3 2 71 14 148 115 208 0.37 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32E2000 KIT08019.011 (Gr.05)
M T 2 L B (1) 3 2 71 14 148 115 208 0.55 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32F2000 KIT08019.012 (Gr.1)

M T 2 M A (1) 3 2 80 19 170 126 234 0.75 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33G2000 KIT08019.013 (Gr.05)
M T 2 M B (1) 3 2 80 19 170 126 234 1.10 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33H2000 KIT08019.014 (Gr.1)

M T 2 N A (1) 3 2 90 24 185 142 247 1.50 230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34L2000 KIT08019.015 (Gr.05)
M T 2 N B (1) 3 2 90 24 185 142 272 2.20 230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34N2000 KIT08019.016 (Gr.1)

M T 2 P A (1) 3 2 100 28 210 155 310 3.00 230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75 M35P2000 KIT08019.017 (Gr.05)
M T 2 P B (1) 3 2 112 28 225 182 325 4.00 230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75 M36Q2000 KIT08019.018 (Gr.1)

M T 4 R A (1) 3 4 63 11 125 95 189 0.12 230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31B4000 KIT08019.009 (Gr.05)
M T 4 R B (1) 3 4 63 11 125 95 189 0.18 230/400 Vac 50 Hz 54 F 60% 16-20 61004300 M5x16 19.5 M31C4000 KIT08019.010 (Gr.1)

M T 4 L A (1) 3 4 71 14 148 115 208 0.25 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32D4000 KIT08019.011 (Gr.05)
M T 4 L B (1) 3 4 71 14 148 115 208 0.37 230/400 Vac 50 Hz 54 F 60% 20-25 61000700 M6x20 19.5 M32E4000 KIT08019.012 (Gr.1)

M T 4 M A (1) 3 4 80 19 170 126 234 0.55 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33F4000 KIT08019.013 (Gr.05)
VI
M T 4 M B (1) 3 4 80 19 170 126 234 0.75 230/400 Vac 50 Hz 54 F 60% 20-25 61000800 M6x20 30.4 M33G4000 KIT08019.014 (Gr.1) AC
M T 4 N A (1) 3 4 90 24 185 142 247 1.10 230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34H4000 KIT08019.015 (Gr.05)
M T 4 N B (1) 3 4 90 24 185 142 272 1.50 230/400 Vac 50 Hz 54 F 60% 20-25 61000900 M8x21 40.4 M34L4000 KIT08019.016 (Gr.1)

M T 4 P A (1) 3 4 100 28 210 155 310 2.20 230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75 M35N4000
KIT08019.017 (Gr.05)
M T 4 P B (1) 3 4 100 28 210 155 310 3.00 230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75 M35P4000
KIT08019.018 (Gr.1)
M T 4 P C (1) 3 4 112 28 225 182 325 4.00 230/400 Vac 50 Hz 54 F 60% 25-32 61001000 M8x28 75 M36Q4000
(•)= Approximate dimensions

IE/FP-6AC/04-2017 79
Sect. VI - AC Motors

8.25 max
5.32 max

(126)

Ø35
6.40
(Ø115)
118
10
Ø1

n°4 - Ø9
118 (175)

Single-phase motors 2-4 Poles - 230 Vac 50Hz - Special housing

Cable gland
Power range

metric thred
Single
Phases

Power Transmission kit Note


Poles

Voltage IP IC Service Motor


Size

kW

KIT08019.005 (for pumps Gr.1)


M M 2 S A (1) 2 2 71 0.75 230 Vac 50 Hz 54 F Light-duty 20 M12GY3FF.001 Without fan
KIT08019.006 (for pumps Gr.0.5)
KIT08019.005 (for pumps Gr.1)
M M 2 S B (1) 2 2 71 1.10 230 Vac 50 Hz 54 F Light-duty 20 M12HY3FF.000 Without fan
KIT08019.006 (for pumps Gr.0.5)

KIT08019.005 (for pumps Gr.1)


M M 4 S C (1) 2 4 71 0.85 230 Vac 50 Hz 54 F Light-duty 20 M12YY3FF.001 Without fan
KIT08019.006 (for pumps Gr.0.5)
IP protection level becomes effective after installationon on power pack.

8.25 max
3.15 max
(117)

Ø35
6.40
(Ø115)
118

0
Ø 11

VI
n°4 - Ø9

118 (175)

AC
Three-phase motors 2-4 Poles - 230/400 Vac 50Hz - Direct fixing
Cable gland

Power range
metric thred

Single
Phases

Power Transmission kit Note


Poles

Voltage IP IC Service Motor


Size

kW

KIT08019.005 (for pumps Gr.1)


M T 2 S A (1) 3 2 71 0.75 230/400 Vac 50 Hz 54 F Light-duty 20 M32GY3FL.003 Without fan
KIT08019.006 (for pumps Gr.0.5)
KIT08019.005 (for pumps Gr.1)
M T 2 S B (1) 3 2 71 1.10 230/400 Vac 50 Hz 54 F Light-duty 20 M32HY3FL.001 Without fan
KIT08019.006 (for pumps Gr.0.5)

KIT08019.005 (for pumps Gr.1)


M T 4 S A (1) 3 4 71 0.75 230/400 Vac 50 Hz 54 F Light-duty 20 M32GY3FL.002 Without fan
KIT08019.006 (for pumps Gr.0.5)
IP protection level becomes effective after installationon on power pack.

80 IE/FP-6AC/04-2017
Sect. VI - AC Motors
With fan Without fan

(126)
(126)

Ø20
Ø20
7.5 7.5

(Ø154)
(Ø154)

118
118
0 0
Ø 11 Ø 11

9.5

n°4 - Ø9
9.5
n°4 - Ø9

118 (238) max 118 (203) max

Three-phase motors 2-4 Poles - 230/400 Vac 50Hz - Direct fixing

Cable gland
Power range

metric thred
Single
Phases

Power Transmission kit Note


Poles

Voltage IP IC Service Motor


Size

kW

KIT08019.007 (for pumps Gr.0.5)


M T 2 T A (1) 3 2 80 2.7 230/400 Vac 50 Hz 44 F Light-duty 20-25 M33YD1FF.000 With fan
KIT08019.008 (for pumps Gr.1)
KIT08019.007 (for pumps Gr.0.5)
M T 2 T B (1) 3 2 80 2.7 230/400 Vac 50 Hz 44 F Light-duty 20-25 M33YD1FF.001 Without fan
KIT08019.008 (for pumps Gr.1)

KIT08019.007 (for pumps Gr.0.5)


M T 4 T A (1) 3 4 80 2.2 230/400 Vac 50 Hz 44 F S3 - 4% 20-25 M33NF1FF.001 Without fan
KIT08019.008 (for pumps Gr.1)
KIT08019.007 (for pumps Gr.0.5)
M T 4 T B (1) 3 4 80 2.2 230/400 Vac 50 Hz 55 F S3 - 4% 20-25 M33NF4FF.000 With fan
KIT08019.008 (for pumps Gr.1)
KIT08019.007 (for pumps Gr.0.5)
M T 4 T C (1) 3 4 80 2.2 230/400 Vac 50 Hz 44 F S3 - 4% 20-25 M33NF1FF.000 With fan
KIT08019.008 (for pumps Gr.1)
KIT08019.007 (for pumps Gr.0.5)
M T 4 T D (1) 3 4 80 3.0 230/400 Vac 50 Hz 54 F Light-duty 20-25 M33PF3FF.000 With fan
KIT08019.008 (for pumps Gr.1)
IP protection level becomes effective after installationon on power pack.
(150)

Ø25

7.5
(Ø175)

VI
Ø110
118

AC
n°4 - Ø9

9.5
118 (280) max

Single-phase motors 4 Poles - 230 Vac 50Hz - Direct fixing


Cable gland

Power range
metric thred

Single
Phases

Power Transmission kit Note


Poles

Voltage IP IC Service Motor


Size

kW

KIT08019.007 (for pumps Gr.0.5) With fan


M M 4 V A (1) 2 4 90 1.8 230 Vac 50 Hz 44 F Light-duty 20-25 M14MF1FF.001
KIT08019.008 (for pumps Gr.1) Start torque 13Nm
KIT08019.007 (for pumps Gr.0.5)
M M 4 V B (1) 2 4 90 3.0 230 Vac 50 Hz 55 F S3 - 7% 20-25 M14PF4FF.000 With fan
KIT08019.008 (for pumps Gr.1)
IP protection level becomes effective after installationon on power pack.

IE/FP-6AC/04-2017 81
Sect. VI - AC Motors
M * * * * (*) /* - Motor orientation

Connector box position on power pack.

Do not use “orientation 1”


/1 with blocks.
Std
/4 P /2

/3

VI
AC

82 IE/FP-6AC/04-2017
Sect. VII - Transmission kit DC motors
Transmission kit (only for motors on the catalog)
Type
End section VII
Specify the transmission kit whether you requested the joint and
accessories assembly (without motor).
FP ........ T ** -

Transmission kit
** For DC motors
Code Pump L Ø

Ø
KIT08019.000 Gr. 0.5 63.3 14 GA (350 W - Ø 80 - Page 72)
GC (700 W - Ø 80 - Page 72) L
01
GB (400 W - Ø 80 - Page 72)
KIT08019.001 Gr. 1 46.9 14 GD (800 W - Ø 80 - Page 72)

Transmission kit
** For DC motors
Code Pump L Ø
AA (1500 W - Ø 115 - Page 73)

Ø
KIT08019.002 Gr. 0.5 64.5 14 EN (1600 W - Ø 115 - Page 73)
AB (2000 W - Ø 115 - Page 73) L
02
ES (2200 W - Ø 115 - Page 73)
KIT08019.003 Gr. 1 48.2 14 GN (1600 W - Ø 115 - Page 74)
GP (2200 W - Ø 115 - Page 74)

32

Transmission kit
Ø

** For DC motors
Code Pump L Ø
GJ (3000 W - Ø 125 - Page 74) L
03 KIT08019.004 Gr. 1 45.4 20
FB (3000 W - Ø 125 - Page 74)
28.5
Note: in ventilated motors (accessory “D” page 74) the transmission is included
in the kit ventilation

VII

IE/FP-7/00-2017 83
Sect. VII - Transmission kit AC motors
Transmission kit (only for motors on the catalog)
Type
End section VII
Specify the transmission kit whether you requested the joint and
accessories assembly (without motor).
FP ........ T ** -

19.5
Transmission kit For AC motors
** Page
Code Pump L Ø L1 Z Ref. Size

Ø 11
Ø
KIT08019.009 Gr. 0.5 47.1 14 30 62.7
63 L
1R R 79 L1
(B14) Z
KIT08019.010 Gr. 1 30.6 20 30 42.8

19.5

Transmission kit For AC motors


** Page

Ø 14
Code Pump L Ø L1 Z Ref. Size

Ø
KIT08019.011 Gr. 0.5 47.1 14 26.5 42 78
71 L L1
1L L
(B14) Z
KIT08019.012 Gr. 1 30.7 20 26.5 42 79

30.4

Transmission kit For AC motors


** Page

Ø 19
Code Pump L Ø L1 Z Ref. Size Ø

KIT08019.013 Gr. 0.5 47.1 14 38 53 78


80 L
1M M L1
(B14) Z
KIT08019.014 Gr. 1 30.7 20 38 53 79

40.4

Transmission kit For AC motors


** Page Ø 24
Code Pump L Ø L1 Z Ref. Size
Ø

KIT08019.015 Gr. 0.5 47.1 14 45.4 63 78


90
1N N L L1
(B14) Z
KIT08019.016 Gr. 1 30.7 20 45.4 63 79

75
Transmission kit For AC motors
** Page
Ø 28

Code Pump L Ø L1 Z Ref. Size


Ø

KIT08019.017 Gr. 0.5 62.9 14/20 57 81.5


100-112
78
1P P L
(B14) L1
KIT08019.018 Gr. 1 46.6 20 57 81.5 79 Z

Transmission kit For AC motors


VII **
Code Pump L Ø L1 Z Ref. Size
Page
Ø

KIT08019.005 Gr. 0.5 64.5 14 71


1S S (direct 80 L

KIT08019.006 Gr. 1 48.2 14 fixing)

Transmission kit For AC motors


** Page
Code Pump L Ø L1 Z Ref. Size
Ø

KIT08019.007 Gr. 0.5 68 14 80-90 L


1T TV 81
KIT08019.008 Gr. 1 51.7 20 (direct fixing)

“Z” : dimension of the coupling side motor

84 IE/FP-7/00-2017
Sect. VIII - Blocks and CETOP valves
Standard blocks
Mounting position
Accessory
Separation line
In the order confirmation the code of the “Blocks and CETOP valves”
will be converted into a type Jxxxx (xxxx = sequential number).

The blocks mounting kit (interface 90°, heighten) is included on the


selection code (see “Mounting kits “table page 88).
FP ... J * (00) -

Blocks mounting on horizontal power pack


J 0 J A J B J C

4 (V60403005)

136.5
4
108.5

3
3 (V60403005)
2 (V60403004) 4 3 2 1 (V60403004)
95

2 4 3 2 1
1
1

Blocks orthogonal to the axis Blocks orthogonal to the axis with Blocks parallel to the axis with Blocks parallel to the axis with
Except AC motors ref. size M-N-P heighten interface 90° heighten and interface 90°
For AC motors ref. size M-N-P Except AC motors ref. size P For AC motors ref. size P

The blocks can not be mounted with motors oriented in position “1” (DC motors, see page 76. AC motors, see page 82).

Blocks mounting on vertical power pack


J 0 J A J B J C 136.5
95 108.5

4 4
3 3
2 2
1 1
1 2 3 4 1 2 3 4
4

(V60403004) (V60403005) (V60403005)

(V60403004)

VIII
Blocks orthogonal to the axis Blocks orthogonal to the axis with Blocks parallel to the axis with Blocks parallel to the axis with
Except AC motors ref. size M-N-P heighten interface 90° heighten and interface 90°
For AC motors ref. size M-N-P Except AC motors ref. size P For AC motors ref. size P

The blocks can not be mounted with motors oriented in position “1” - DC motors, see page 76. AC motors, see page 82.

IE/FP-9/04-2019 85
Sect. VIII - Blocks and CETOP valves
Block type
Accessory
Pressure relief valve setting on “A” line
Pressure relief valve setting on “B”line
CETOP valve
End section VIII

FP ..J*(00) ** (00) (..) (..) /***/ -


Repeat for each block (max.5)

** (00) (..) (..) /***/ - Block type

** (00) (..) (..) Description Code Drawing Scheme


T1
55 P1

A
A2 (00) (0) (0) Middle parallel - Lateral ports G3/8” V60403010

49
P1 T1
80 A B
B
T1
.5 A
39
B
P1 P T
A3 (00) (0) (0) Middle parallel - Rear ports G3/8” V60403001
80 49

T1
55 P1

A
B2 (00) (0) (0) Middle series - Lateral ports G3/8” V60403011
49

P1 T1
80 A B
B
T1
.5 A
39
B P T
P1
B3 (00) (0) (0) Middle series - Rear ports G3/8” V60403003
49

80

P1 T1
A B
With pilot check valve on ”A” port .
E1 (00) (0) (0) Rear ports G1/4”
V60413002

P T
T1 P1 T1
55 P1
A B
With pilot check valve on ”B” port. A
E2 (00) (0) (0) V60413003
49

Rear ports G1/4”

VIII 80
B P T
P1 T1
A B
With pilot check valve on ”A” and “B” ports.
E3 (00) (0) (0) Rear ports G1/4”
V60413001

P T

P1 - T1: thread, closing with plug G1/8” (Plug Q26622251 + Washer Q51435012)

86 IE/FP-9/04-2019
Sect. VIII - Blocks and CETOP valves
** (00) (..) (..) /***/ - Block type

** (00) (..) (..) Description Code Drawing Scheme


With pressure relief valve on “A” port
(D) (0) Setting 15 ÷ 50 bar - Lateral ports G1/4”
1318828
T1 P1 T1
.5
With pressure relief valve on “A” port 69 P1
(E) (0) Setting 50 ÷ 110 bar - Lateral ports G1/4”
1318829 A B
F1 (00) A

49
With pressure relief valve on “A” port
(F) (0) Setting 110 ÷ 220 bar - Lateral ports G1/4”
1318830
80
B P T
With pressure relief valve on “A” port
(G) (0) Setting 220 ÷ 290 bar - Lateral ports G1/4”
1318831

With pressure relief valve on “B” port


(0) (D) Setting 15 ÷ 50 bar - Lateral ports G1/4”
1318832
T1 P1 T1
.5
69 P1
With pressure relief valve on “B” port A B
(0) (E) Setting 50 ÷ 110 bar - Lateral ports G1/4”
1318833
F2 (00)

49
A
With pressure relief valve on “B” port
(0) (F) Setting 110 ÷ 220 bar - Lateral ports G1/4”
1318834 80
B P T
With pressure relief valve on “B” port
(0) (G) Setting 220 ÷ 290 bar - Lateral ports G1/4”
1318835

With pressure relief valve on “A” and “B”


(D) (D) Setting 15 ÷ 50 bar - Lateral ports G1/4”
1318836
T1
69
.5 P1 T1
With pressure relief valve on “A” and “B” P1
(E) (E) Setting 50 ÷ 110 bar - Lateral ports G1/4”
1318837 A B
F3 (00)

49
A
With pressure relief valve on “A” and “B”
(F) (F) Setting 110 ÷ 220 bar - Lateral ports G1/4”
1318838 80
B P T
With pressure relief valve on “A” and “B”
(G) (G) Setting 220 ÷ 290 bar - Lateral ports G1/4”
1318839

P1 - T1: thread, closing with plug G1/8” (Plug Q26622251 + Washer Q51435012)

VIII

IE/FP-9/04-2019 87
Sect. VIII - Blocks and CETOP valves

Mounting kits
Mounting kit: blocks For No. blocks Code
1 V60513007
2 V60513008
Mounting position 0-2-3
3 V60513009
4 V60513010
1 V60513011
Mounting position 1 2 V60513012
(with heighten) 3 V60513013
4 V60513014

Mounting kit: interface 90° Code


Mounting position 2 V60513051

Mounting kit: interface 90° with heighten Code


Mounting position 3 V60513049

The blocks mounting kit (interface 90°, heighten) is included on the


selection code (see mounting position, page 85).

connectors supplied
with the valve (1)

** (00) (..) (..) /***/ - CETOP 3 valves

Spool (2) Screw kit for valve


/***/ Voltage Code
Type Mounting Scheme mounting
/000/ Without valve

/001/ 24 VDC (M) ADC3E01CM001 A B

01 C a b
P T
/002/ 12 VDC (L) ADC3E01CL001

/003/ 24 VDC (M) ADC3E02CM001 A B

02 C
a b
/004/ 12 VDC (L) ADC3E02CL001 P T

V60513015
/005/ 24 VDC (M) ADC3E03CM001 A B

03 C
VIII /006/ 12 VDC (L) ADC3E03CL001
a
P T
b

/007/ 24 VDC (M) ADC3E04CM001 A B

04 C a b
P T
/008/ 12 VDC (L) ADC3E04CL001

1 = Valves supplied with connector. Without connector see accessories page 89


2 = More details, features and performances, see catalog Dana “Valves and Electronics” code DOC00078

88 IE/FP-9/04-2019
Sect. IX - Accessories
Accessories (optional)
First accessory
Second accessory

FP ........ R * *

* Description Drawing Code Note

124 All motors are compatible


124

45,5
except orientation / 3

Tanks compatible
Kit
Standard foot, (galvanized sheet steel) (except for orientation / 3)
A (foot and screws):
thickness 2.5 mm (unassembled) S**A
n°4 Ø 9,5 17010075
S**B
S**C
S**G
S**L

Non-removable red plastic plug for pressure Plug:


B relief valve (unassembled) 60309200

For motors:
Kit M2EN
Protection device for DC motors (protectin, nut, M4ES
C (supplied assembled) tierods, washers):
17010048 With blocks, please add the
block code 91006000.000

All motors are compatible


125 120 except orientation / 3
48

Tanks compatible
(except for orientation / 3)
Kit
High foot, (galvanized sheet steel) thickness S**A
D (foot and screws):
2 mm (unassembled) S**B
n°4 Ø 9 17010053
S**C
S**D
S**F
S**G
S**L

101.6

Collar:
Ø 25000300
11
4
101.6

Ø 121

Collar in welded sheet steel, thickness 2 mm


E (unassembled) Tank fixing kit
(screws and O-Ring):
17010080

4 FORI M6 26

IX
F Without valves connectors

IE/FP-9/03-2017 89
Examples
Examples with FPA endhead
A B 5
A B 5TG FPA 0 F1 2DAAA+B 5TG -03 - ..
Cavity Code Description Page
Thread ports P-T G1/4”
- 0 13
(blocks interface)
2DAAA +B Pressure relief valve with check
2 valve (75 ÷ 220 bar) with screw
1 F1 14
and detachable closing, standard
1 setting 150 bar
B Piloted solenoid valve normally closed,
2DAAA
2 without emergency. Voltage 12 16
+B
VDC + Flow control valve 1.4 l/min
7 6 5 5TG Plug 18
7 6 6-7
Not specified, return lines 6 and 7

open
Combinations plugs on ports
A-B -03 20
(A= open; B= with plug)
- - End section —

FPA 0 E1(90) 2DAAA 5TG+B 7C -00 - ..


A B 5
Cavity Code Description Page
A B 5TG
Thread ports P-T G1/4”
- 0 13
(blocks interface)
Pressure relief valve with check
1 E1(90) valve with screw and detachable 14
2DAAA
closing, special setting 90 bar
2 Piloted solenoid valve normally closed,
+* 2 2DAAA 16
without emergency. Voltage 12 VDC
1 5TG
5 Plug + Flow control valve 1.4 l/min 18
B(170) +B
6 Not specified, return line 6 open —
Flow control valve on return 7, flow
6
7 7C 19
7C 2.1 l/min
7 6 Combinations plugs on ports
A-B -00 20
(A,B= open)
- - End section —

FPA 0 F1 2DAAA 5TG 6C -03 - ..


A B 5
A B 5TG Cavity Code Description Page
Thread ports P-T G1/4”
- 0 13
(blocks interface)
Pressure relief valve with check
valve (75 ÷ 220 bar) with screw
2DAAA 1 F1 14
2 and detachable closing, standard
setting 150 bar
Piloted solenoid valve normally closed,
1 2 2DAAA
without emergency. Voltage 12 VDC
16
B 5 5TG Plug 18
6 6C Not specified, return line 6 open 19
7 Not specified, return line 7 open —
7 6C
Combinations plugs on ports
7 6 A-B -03 20
(A= open; B= with plug)
- - End section —

90
Examples
Examples with FPC endhead

FPC 0 F1 2DAAA 3TE 4TK 5TG+B 7C 9C -01 - ..


Cavity Code
Description Page
A B 5 C Thread ports P-T G1/4”
A B 5TG C - 0 13
(blocks interface)
Pressure relief valve with check
valve (75 ÷ 220 bar) with screw
1 F1 21
and detachable closing, standard
2DAAA 3TE setting 150 bar
2 3 Piloted solenoid valve normally closed,
+B 2 2DAAA without emergency. 23
Voltage 12 VDC
4TK B 3 3TE Plug 27
4 1 4 4TK Plug (union G1/4) 30
G 1/4 7 6 5TG
5 Plug + Flow control valve 1.4 l/min 31
8 7C 6 9C +B
6 Not specified, return line 6 open —
7 7C Flow control valve 2.1 l/min 32
8 9 8 Not specified, return line 8 open —
9 9C Flow control valve 2.1 l/min 32
Combinations plugs on ports
A-B-C -01 33
(A-B-C= open)
- - End section —

FPC 0 E1(90) 2DAAA 3TC+B 4HA 5TH 8C -05 - ..


A B 5 C Cavity Code Description Page
A 5TH Thread ports P-T G1/4”
- 0 13
(blocks interface)
Pressure relief valve with check
1 E1(90) valve with screw and detachable 21
2DAAA +E 3TC closing, special setting 90 bar
Piloted solenoid valve normally closed,
2 3 2 2DAAA without emergency. 23
Voltage 12 VDC
3TG
4HA B(170) 3 Plug + Flow control valve 1.4 l/min 27
+B
4 1 4 4HA Push-button control 30
7 6 5 5TH Plug 31
8C 7 6 9
6-7 Not specified, return lines 6 and 7 open —
8 8C Flow control valve 2.1 l/min —
8 9 9 Not specified, return 9 open 32
Combinations plugs on ports
A-B-C -05 33
(A = open; B-C= with plug)
- - End section —

91
Examples

FPC 0 F1 2TD 3TE 4DAAAA 5TH 7C 8C 9C -01 - ..


Cavity Code
Description Page
Thread ports P-T G1/4”
A B 5 C - 0
(blocks interface)
13
A B 5TH C
Pressure relief valve with check
valve (75 ÷ 220 bar) with screw
1 F1 21
and detachable closing, standard
setting 150 bar
2TD 3TE 2 2TD Plug (union G1/4) 24
2 3 3 3TE Plug 27
G 1/4 Piloted solenoid valve normally closed,
4 4DAAAA without emergency. 29
4DAAA B Voltage 12 VDC
4 1 5 5TH Plug 31
7 6 6 Not specified, return line 6 open —
8C 7C 6 9
9C 7 7C Flow control valve 2.1 l/min 32
8 8C Flow control valve 2.1 l/min 32
9 9C Flow control valve 2.1 l/min 32
8 9 Combinations plugs on ports
A-B-C -01 33
(A-B-C= open)
- - End section —

FPC 0 F1 2TC 3DDAA 4ZA 5TH 9C -05 - ..


A B 5 C Cavity Code
Description Page
A 5TH C
Thread ports P-T G1/4”
- 0 13
(blocks interface)
Pressure relief valve with check
valve (75 ÷ 220 bar) with screw
1 F1 21
2TC 3DDAA and detachable closing, standard
2 3 setting 150 bar
2 2TC Plug 24
Piloted solenoid valve normally
4ZA B 3 3DDAA closed, with emergency. 26
4 1 Voltage 12 VDC
7 6 4 4ZA Hand pump displacement 1cc 30
8 7 6 9C
9 5 5TH Plug 31
6-7-8 Not specified, return lines 6-7-8 open —
9 9C Flow control valve 2.1 l/min 32
8 9 Combinations plugs on ports
A-B-C -05 33
(A = open; B-C= with plug)
- - End section —

92
Examples
Examples with FPL endhead

FPL 0 F1 2DDAA 3DDAA 4DAAA 8C -04 - ..


Cavity Code
Description Page
Thread ports P-T G1/4”
A B D C - 0
(blocks interface)
13
A B D C
Pressure relief valve with check
valve (75 ÷ 220 bar) with screw
1 F1 34
and detachable closing, standard
setting 150 bar
2DDAA 3DDAA Direct operated solenoid valve
2 3 2 2DDAA normally closed, with emergency 36
Voltage 12 VDC
Direct operated solenoid valve
4DAAA B 3 3DDAA normally closed, with emergency 39
4 1 Voltage 12 VDC
Piloted solenoid valve normall closed,
8C 7 4 4DAAA without emergency. 42
Voltage 12 VDC
7 Not specified, return line 7 open —
8 7 8 8C Flow control valve 2.1 l/min 44
Combinations plugs on ports
A-B-C-D -04 45
(A-B-C= open; D= with plug)
- - End section —

FPL 0 F1(100) 2DDAA 3DDAA 4TE -04 - ..


A B D C Cavity Code Description Page
A B D C
Thread ports P-T G1/4”
- 0 13
(blocks interface)
Pressure relief valve with check
1 F1(100) valve with screw and detachable 34
2DDAA 3DDAA closing, special setting 100 bar
2 3 Direct operated solenoid valve
2 2DDAA normally closed, with emergency 36
Voltage 12 VDC
4TE B Direct operated solenoid valve
4 1 3 3DDAA normally closed, with emergency 39
Voltage 12 VDC
8 7 Piloted solenoid valve normall closed,
4 4TE without emergency. 43
Voltage 12 VDC
8 7 7-8 Not specified, return lines 7-8 open —
Combinations plugs on ports
A-B-C-D -04 45
(A-C= open; B-D= with plug)
- - End section —

93
Examples
Examples with FPE endhead

FPE 0 F1 2D(1A)AA 3TC+B -04 - ..


Cavity Code Description Page
Thread ports P-T G1/4”
A B D C - 0
(blocks interface)
13
A B
Pressure relief valve with check
valve (75 ÷ 220 bar) with screw
1 F1 46
and detachable closing, standard
setting 150 bar
+B 3TC Directional control valve 4 way 3
2D(1A)
22D(1A)AA 2 4
3 2
AA
positions with emergency. Voltage 48
S2
2 S1 12 Vdc (closed centre “C” spool)
3 1 3TC
3 Plug + Flow control valve 1.4 l/min 50
1B +B
1 9 Not specified, return 9 open —
Combinations plugs on ports
A-B-C-D -04 52
9 (A-B= with protection; C-D= with plug)
- - End section —

FPE 0 F1 2D(2A)AA 3TC 9C -04 - ..


Cavity Code Description Page
A B D C Thread ports P-T G1/4”
- 0 13
A B (blocks interface)
Pressure relief valve with check
valve (75 ÷ 220 bar) with screw
1 F1 46
and detachable closing, standard
3TC setting 150 bar
2D(2A)AA 2 4
3 Directional control valve 4 way 3
2D(2A)
2 positions with emergency. Voltage 48
2 AA
3 1
12 Vdc (closed centre “C” spool)
1B
3 3TC Plug 50
9 9C Flow control valve 2.1 l/min 51
1 Combinations plugs on ports
A-B-C-D -04 52
(A-B= with protection; C-D= with plug)
9C
- - End section —

94
Note

95
Note

96
®

Code DOC00038 - Rev. 08

Dana Motion Systems Italia S.r.l.


Fluid Power Division

Sede operativa: Via Giulio Natta 1, 42124 Reggio Emilia - Italy


Tel: +39.0522.270711 - Fax: +39.0522.505856

Sede legale: Via Luciano Brevini 1/A, 42124 Reggio Emilia - Italy
Tel: +39.0522.9281 - Fax: +39.0522.928300

www.dana.com/brevini - dana.re@dana.com

You might also like